TFA AirCo2ntrol Up 31.5011.10 - Gas detector

AirCo2ntrol Up 31.5011.10 - Gas detector TFA - Free user manual and instructions

Find the device manual for free AirCo2ntrol Up 31.5011.10 TFA in PDF.

📄 12 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice TFA AirCo2ntrol Up 31.5011.10 - page 9
View the manual : Deutsch DE English EN
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Indoor CO2 Monitor
Sensor Technology Non-dispersive infrared (NDIR)
CO2 Measurement Range 0 - 9999 ppm
CO2 Accuracy ±50 ppm or ±5% of reading (whichever is greater)
Display Type LCD with backlight
Displayed Parameters CO2 concentration, temperature, humidity
Temperature Measurement Range 0°C to 50°C (32°F to 122°F)
Humidity Measurement Range 0% to 99% RH
Alarm Type Audible and visual alarm when CO2 exceeds set threshold
Power Supply USB-C (5V DC) or 3x AAA batteries (not included)
Battery Life (typical) Up to 6 hours (with batteries)
Dimensions 120 x 70 x 25 mm (4.7 x 2.8 x 1.0 in)
Weight 110 g (3.9 oz) without batteries
Mounting Tabletop or wall-mountable (bracket included)
Calibration Automatic baseline calibration (ABC) or manual calibration in fresh air
Operating Temperature 0°C to 50°C (32°F to 122°F)
Storage Temperature -10°C to 60°C (14°F to 140°F)
Humidity Range (non-condensing) 0% to 90% RH
Data Logging No internal memory for logs
Warranty 2 years

Frequently Asked Questions - AirCo2ntrol Up 31.5011.10 TFA

What does the AirCo2ntrol Up measure?
It measures CO2 concentration, temperature, and humidity in indoor air.
How does the alarm work?
The device triggers an audible and visual alarm when CO2 levels exceed a preset threshold (e.g., 1000 ppm). You can adjust the threshold via settings.
Can I use it with batteries only?
Yes, it can be powered by 3 AAA batteries (not included). However, for continuous use, the USB-C connection is recommended.
How do I calibrate the sensor?
The device features automatic baseline calibration (ABC). Place it in fresh outdoor air (400 ppm) for a few minutes to recalibrate manually.
What is the recommended placement?
Place at 1.5 m (5 ft) above floor level, away from windows, vents, and direct sunlight. Avoid areas with high humidity or rapid temperature changes.
How accurate is the CO2 reading?
Accuracy is ±50 ppm or ±5% of reading (whichever is greater) at room temperature.
Does it have a data logging function?
No, this model does not have internal memory for storing historical data. It provides real-time readings only.
How do I clean the device?
Wipe the exterior with a soft, dry cloth. Do not use water or cleaning agents. Keep the sensor openings free from dust.
What does the backlight do?
The LCD backlight automatically illuminates when a button is pressed or when an alarm occurs. It can be set to always on via USB power.
What is the expected lifespan of the sensor?
The NDIR sensor typically lasts more than 5 years under normal use. Calibration may drift over time, requiring periodic recalibration.

User questions about AirCo2ntrol Up 31.5011.10 TFA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Gas detector in PDF format for free! Find your manual AirCo2ntrol Up 31.5011.10 - TFA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AirCo2ntrol Up 31.5011.10 by TFA.

USER MANUAL AirCo2ntrol Up 31.5011.10 TFA

TFA AirCo2ntrol Up 31.5011.10 - 1

TFA AirCo2ntrol Up 31.5011.10 - 2

Instruction manuals

Kat. Nr. 31.5011.10

www.tfa-dostmann.de/en/service/downloads/instruction-manuals

CE UK CA

TFA AirCo2ntrol Up 31.5011.10 - 3

Thank you for choosing this instrument from TFA.

Before you use this product

  • Please make sure you read the instruction manual carefully.
  • The operating instructions are enclosed with the device or can be downloaded at www.tfa-dostmann.de/en/service/downloads/instruction-manuals
  • This product should only be used as described within these instructions.
  • Following and respecting the instructions in your manual will prevent damage to your instrument and loss of your statutory rights arising from defects due to incorrect use.
  • Please take particular note of the safety advice!
  • Please keep this instruction manual safe for future reference.

MEM SET SET SET B 7 RESET C 1

AIR CO 2 NTROL UP Single Beam – CO 2 Monitor

TFA AirCo2ntrol Up 31.5011.10 - AIR CO 2 NTROL UP Single Beam – CO 2 Monitor - 1

1. Lieferumfang

AIR CO 2 NTROL UP Single Beam – CO 2 Monitor

TFA AirCo2ntrol Up 31.5011.10 - AIR CO 2 NTROL UP Single Beam – CO 2 Monitor - 1

5. Inbetriebnahme

AIR CO 2 NTROL UP Single Beam – CO 2 Monitor

TFA AirCo2ntrol Up 31.5011.10 - AIR CO 2 NTROL UP Single Beam – CO 2 Monitor - 1

AIR CO 2 NTROL UP Single Beam – CO 2 Monitor

TFA AirCo2ntrol Up 31.5011.10 - AIR CO 2 NTROL UP Single Beam – CO 2 Monitor - 1

Input: 100-240V AC 50/60Hz 0.5A max

Output: 5.0V DC 1.0A, 5.0W

AIR CO 2 NTROL UP Single Beam – CO 2 Monitor GB

1. Delivery contents

  • CO2 Monitor
    • USB-Type-C-1,5 m cable and power adaptor
  • Instruction manual

2. Range of application and all the benefits of your new instrument at a glance

  • For monitoring the CO2 concentration in buildings, where people are present, eg: schools, offices, public facilities
    • Single Beam NDIR Sensor
  • Large CO 2 display with extended traffic light indication (green/yellow/blue/red)
    • Display of indoor temperature (°C/°F) and humidity
  • Memory of the highest and lowest values of CO 2 , temperature and humidity
  • Alarm function for CO 2 concentration
    • High contrast display with 4 brightness levels
  • Manual calibration function for CO 2 sensor
  • Power connection via USB Type-C cable and power supply (included) or a suitable USB power source

3. For your safety

  • This product is exclusively intended for the range of application described above. It should only be used as described within these instructions.
  • Unauthorized repairs, alterations or changes to the product are prohibited.

TFA AirCo2ntrol Up 31.5011.10 - For your safety - 1

Caution!

Risk of electrocution!

  • Connect the device using the USB cable and the supplied power supply to a mains socket installed within your country's electrical safety regulations and with a correct mains voltage (see nameplate) or connect the device via the USB cable to a suitable USB power source such as a computer, notebook.
  • The mains socket must be located near the equipment and it must be easily accessible.
  • Unplug the device immediately if any fault occurs.
  • The device and the power adapter must not come into contact with water or moisture. Only suitable for indoor use.

AIR CO 2 NTROL UP Single Beam – CO 2 Monitor GB

  • Do not use the device if the housing, the USB cable or the power adaptor are damaged.
  • Operate the device out of reach of persons (including children) who cannot fully appreciate the potential risks of handling electrical equipment.
  • Connect the USB cable to the device and the power adaptor first and then plug the power adapter into the socket.
  • Route the USB cable lead so that it does not come into contact with sharpedged or hot objects.

TFA AirCo2ntrol Up 31.5011.10 - AIR CO 2 NTROL UP Single Beam – CO 2 Monitor GB - 1

Important information on product safety!

  • Do not expose the device to extreme temperatures, vibrations or shocks. Avoid direct sunshine.
  • The instrument is not unbreakable. In case of falling down parts can break.

4. Elements

A: LCD display (Fig. 1):

A 1: CO₂ alarm limit
A 2: CO 2 indication
A 3: Display of minimum values
A 4: CO
2 value > 2000 ppm
A 5: Extended traffic light indication
A 6: Indoor temperature and humidity
A 7: CO 2 alarm symbol
A 8: Display of maximum values

B: Buttons (Fig. 1+2):

B 1: POWER/LIGHT sensor button
B 2: DOWN/CALIBRATE button
B 3: MEM button
B 4: CO 2 SET button
B 5: CO 2 ALARM button
B 6: UP/°C/°F button
B 7: RESET button

C: Housing (Fig. 3):

C 1: USB port

AIR CO2NTROL UP Single Beam - CO2 Monitor

TFA AirCo2ntrol Up 31.5011.10 - AIR CO2NTROL UP Single Beam - CO2 Monitor - 1

5. Getting started

Important note:

When using the device for the first time, please make sure to connect the power supply uninterruptedly for 24 hours. The device will perform an automatic calibration within 24 hours.

- Plug the supplied USB-C cable into the designated port on the device and connect the unit to the mains using the power adapter.

6. Operation

  • Press the POWER/LIGHT sensor button for 3 seconds to switch on the device.
  • The device will issue two beeps and all segments will be displayed briefly.
  • The display shows the current temperature and humidity.
  • The CO 2 sensor goes into warm-up mode and starts a 150-second count-down. Afterwards the normal display appears. The device is ready for use.
  • Press the UP/°C/°F button in normal mode to change between °C (Celsius) or °F (Fahrenheit) as temperature units.
  • Briefly press the POWER/LIGHT sensor button to adjust the brightness in 4 steps (high, medium, low, off).
  • Press the POWER/LIGHT sensor button for 3 seconds to deactivate the device.

7. Traffic light display

- The CO2 monitor shows the CO2 comfort level with an extended traffic light display:

CO2 value (ppm) Description
400-600 GOOD
601-1000 NORMAL
1001-1500 POOR
1501-2000SERIOUS
2000 ↑SERIOUS + ▲

AIR CO 2 NTROL UP Single Beam – CO 2 Monitor

TFA AirCo2ntrol Up 31.5011.10 - AIR CO 2 NTROL UP Single Beam – CO 2 Monitor - 1

8. CO₂ upper limit

  • Press briefly the CO2 SET button in normal mode. And 2000 ppm (default) or the last adjusted upper CO2 limit appear on the display. After 3 seconds, the device automatically returns to the normal mode.
  • Press and hold the CO₂ SET button for 2 seconds to enter the setting mode. The value flashes.
  • Press the DOWN/CALIBRATE or UP/°C/°F button to set the desired upper limit in steps of 10ppm, while the value flashes.
  • Press and hold the DOWN/CALIBRATE or UP/°C/°F button in setting mode for fast mode.
  • Confirm the setting with the CO 2 SET button.
  • The device will automatically quit the setting mode if no button is pressed for 20 seconds. The setting is saved.
  • Press the CO 2 ALARM button in normal mode, to activate or deactivate the alarm function for the upper CO 2 limit. Appears on the display when the alarm is activated.
  • If the measured CO2 value is above the upper limit setting, an alarm sounds and the CO2 alarm symbol flashes. Press any button to stop the alarm sound. The CO2 alarm symbol will continue flashing until the measured CO2 value is below the set alarm limit.

9. CO₂, temperature and humidity maximum and minimum values

  • Press the MEM button in normal mode.
  • You can now read the highest measured values for CO 2 , temperature and humidity of the last 24 hours (display MAX).
  • Press the MEM button again.
  • The minimum values measured since the last 24 hours appear on the display (display MIN.
  • Press the MEM button again to return to normal mode. The device will automatically quit the MAX/MIN mode if no button is pressed for 3 seconds.
  • Press and hold the MEM button for 2 seconds during the highest or lowest values are displayed. The values will be deleted (display ----) and reset to the current state.

10. Calibration of the CO₂ sensor

10.1 Automatic calibration of the CO₂ sensor

- The sensor is automatically calibrated every 24 hours to the lowest CO 2 reading obtained during that period to keep the deviation low during prolonged use. To perform the calibration, the power supply must be connected continuously for 24 hours.

AIR CO2NTROL UP Single Beam - CO2 Monitor

TFA AirCo2ntrol Up 31.5011.10 - AIR CO2NTROL UP Single Beam - CO2 Monitor - 1

  • For proper functioning, it is therefore necessary to ensure maximum ventilation at least once a day. Otherwise, the device is using a faulty basis for automatic calibration and an incorrect display may occur. In this case, a restart under fresh air conditions or a manual calibration as described below is recommended.
  • Note: The product is not suitable for a location where ideal ventilation is not possible (in permanently closed rooms).

10.2 Manual calibration of the CO2 sensor

  • For the whole calibration process, place the device outdoors. Choose a shady and dry place. Wait 15 minutes, the device must adapt to the environment.
  • Use a pin to press the RESET button at the bottom. Wait until the normal display appears (see point 6. "Operation").
  • Then press and hold the DOWN/CALIBRATE button for 2 seconds to enter the manual calibration mode. The CAL symbol flashes.
  • Wait approx. 20 minutes, until the normal display with a CO 2 concentration of 400 ppm (fresh air) appears. The calibration is completed and the device returns to normal state. Now you can use the device again as usual.
  • During the manual calibration operation, press the DOWN/CALIBRATE button to exit the calibration mode.

11. Care and maintenance

  • Clean the device with a soft damp cloth. Do not use solvents or scouring agents.
  • Turn off the device if you do not use it. Press the POWER/LIGHT sensor button for 3 seconds.
  • Store the device in a dry place.

12. Troubleshooting

Problem Solution

No display on the device→ Press the POWER/LIGHT button for 3 seconds to switch on the device
→ Set the brightness with the POWER/LIGHT button
→ Connect the device with USB cable and power adapter
→ Check the connection

AIR CO 2 NTROL UP Single Beam – CO 2 Monitor

TFA AirCo2ntrol Up 31.5011.10 - AIR CO 2 NTROL UP Single Beam – CO 2 Monitor - 1

Incorrect indication

Display Err

→ Use a pin to press the RESET button

Indication: LL / HH → Outside measuring range

If your device fails to work despite these measures, contact the retailer where you purchased the product.

13. Waste disposal

This product and its packaging have been manufactured using high-grade materials and components which can be recycled and reused. This reduces waste and protects the environment.

Dispose of the packaging in an environmentally friendly manner using the collection systems that have been set up.

TFA AirCo2ntrol Up 31.5011.10 - Waste disposal - 1

Disposal of the electrical device

This product is labelled in accordance with the EU Waste Electrical and Electronic Equipment Directive (WEEE).

Please do not dispose of this product in ordinary household waste. As a consumer, you are required to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment, in order to ensure environmentally-compatible disposal. Observe the current regulations in place!

  1. Specifications
Power supply USB-Type-C-1.5 m cable with power supply(included)Input: 100-240V AC 50/60Hz 0.5A maxOutput: 5.0V DC 1.0A, 5.0WAverage active efficiency: ≥73.62%No-load power consumption: ≤0.10 W

CO2

Measuring methodSingle Beam Non-Dispersive-Infrared Technology (NDIR)

Measuring range 400ppm - 5000ppm

Resolution 1 ppm

Accuracy ± 100 ppm ± 10%

Update interval 4 seconds
Warm-up time 150 seconds
Recommended operating temperature range +10...30°C CO2 sensor (Ideal conditions also for manual calibration)
Temperature Measuring range 0 °C... +50°C (32°F...122°F) Resolution 0.1°C Accuracy ±1 °C
Humidity Measuring range 25...95%RH Resolution 1% RH Accuracy ±5% RH
Housing dimension 77 x 96 x 144 mm
Weight 172 g (device only)

No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are correct at the time of going to print and may change without prior notice. The latest technical data and information about this product can be found in our homepage by simply entering the product number in the search box

www.tfa-dostmann.de