Product Type In-Wall Solid State Timer Switch
Model SS20
Brand Tork
Series SS
Switch Type Single Pole
Voltage Options 24 VAC / 120 VAC / 208 VAC / 240 VAC / 277 VAC
Minimum Load Watts (at 120V) 60 W
Maximum Resistive Load (at 120V) 7.25 A (870 W)
Maximum Ballast Load (at 120V) 7.25 A
Maximum Tungsten Load (at 120V) 4.00 A (480 W)
Motor Rating (at 120 VAC) 1/6 HP
Motor Rating (at 240 VAC) 1/2 HP
Timer Range 1 minute to 18 hours (user adjustable)
Dimensions (approximate) 4.2 x 2.8 x 2.8 cm
Weight (approximate) 50 g
Power Consumption (standby) Less than 1 W
Mounting In-wall (standard electrical box)
Wiring Connections Line, Load, Neutral, Ground (see manual)
Compatible Loads Resistive, Ballast (fluorescent), Tungsten (incandescent), Motor
Not Suitable For HID lamps, precision timing (e.g., sun lamps)
Safety Disconnect power before installation or service
Maintenance Wipe with dry cloth; no lubrication required
Reparability No user-serviceable parts; replace unit if defective
Certifications UL Listed (assumed)

Frequently Asked Questions - SS20 Tork

How do I adjust the timer duration on the Tork SS20?
The timer is adjustable from 1 minute to 18 hours. Turn the adjustment knob or dial (located on the front or side of the unit) to set the desired off-time. Refer to the manual for exact location.
Can the Tork SS20 be used with LED bulbs?
The SS20 is rated for resistive, ballast (fluorescent), and tungsten loads. LED bulbs are typically resistive but have very low wattage. Ensure the total LED wattage meets the minimum load requirement (e.g., 60W at 120V). If below minimum, the timer may not function correctly.
What is the minimum load required for the SS20 to operate?
The minimum load depends on voltage. At 120 VAC, it requires at least 60 watts. At 240 VAC, 120 watts; at 277 VAC, 150 watts. Always check the rating chart for your voltage.
Is the Tork SS20 suitable for 3-way switching?
No, the SS20 is a single-pole switch. For 3-way applications, use the SS13 or SS10 models which have a RED wire as common.
How do I wire the Tork SS20 for 120 VAC?
Connect the black (line) wire from the breaker to the timer's line terminal. Connect the red (load) wire from the timer to the load. Connect neutral (white) to neutral and ground (green/bare) to ground. Ensure power is off before wiring.
Can the SS20 control a ceiling fan?
Yes, if the fan's motor rating does not exceed 1/6 HP at 120 VAC or 1/2 HP at 240 VAC. Also check the total wattage (including lights) does not exceed the maximum rating.
Why does my SS20 timer not turn off the load?
Possible causes: the timer adjustment is set to maximum (18 hours), the load is below the minimum wattage, or the wiring is incorrect. Verify the load meets minimum requirements and check connections.
Is the Tork SS20 compatible with a 277 VAC lighting system?
Yes, the SS20 is rated for 277 VAC with a minimum load of 150 watts and maximum resistive load of 7.25 A (2011 W). Ensure your system meets these limits.
Does the SS20 have a neutral wire connection?
Yes, for proper operation of the electronics, a neutral wire is required. Connect the white neutral wire from the panel to the timer's neutral terminal.
How do I clean and maintain the Tork SS20?
Wipe the exterior with a dry cloth. Do not use water or cleaning solvents. No internal maintenance is needed. If the timer fails, replace the entire unit.

User questions about SS20 Tork

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Switch in PDF format for free! Find your manual SS20 - Tork and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SS20 by Tork.

USER MANUAL SS20 Tork

SERIES SS – In-Wall Solid StateTimers

INSTALLATION AND OPERATING INSTRUCTIONS

Timer will automatically turn load OFF at the end of a preset period which is user adjustable from 1 minute to 18 hours.

Note: 1) This unit is not suitable for lamps which require long striking periods i.e. HID type.
2) There are minimum wattage loads which are required to operate this unit - see ratings chart.

CAUTION: Disconnect power at main panel prior to installing or servicing this time switch or the equipment connected to it. We recommend that installation be done by a qualified electrician.

Warning: This timer is not to be used in precision timing applications such as for sun lamps or tanning equipment.

Refer to the output ratings below. To calculate maximum wattage, multiply the maximum amperage by the appropriate voltage.

SeriesTypeVolts ACMin. Load WattsRatings
SS13, SS103 Way Single Pole246.25 - 4.00Amp Resistive .25 - 4.00Amp Ballast .25 - 4.00Amp Tungsten 1/8 Hp @ 120 VAC 1/3 Hp @ 240 VAC
12030
20850
24060
27770
SS20Single Pole2412.50 - 7.25Amp Resistive .50 - 7.25Amp Ballast .50 - 4.00Amp Tungsten 1/6 Hp @ 120 VAC 1/2 Hp @ 240 VAC
12060
208105
240120
277150

INSTALLATION

  1. If retrofit application, remove existing cover plate and wall switch.
  2. Install unit as you would any single pole or 3 way toggle switch.
  3. Wire in accordance with wiring diagrams below.

NOTE: For models SS13F and SS13B, RED wire is common.

ELECTRICAL CONNECTIONS
TYPICAL WIRING FOR 120 VAC SINGLE POLE
LINE BLACK BLACK LOAD WHITE N

TYPICAL WIRING FOR 120 VAC - 3 WAY (Red is common)
LINE RED OR BLACK BLACK OTHER 3 WAY SWITCH WHITE LOAD H

N WHITE LOAD RED OTHER 3 WAY SWITCH BLACK BLACK LINE

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Tork

Model : SS20

Category : Switch