UPS-TRI10K - Inverter Mach Power - Free user manual and instructions
Find the device manual for free UPS-TRI10K Mach Power in PDF.
| Brand | Mach Power |
| Model | UPS-TRI10K |
| Type | Line-interactive UPS |
| Power Capacity | 10 kVA / 9 kW |
| Input Voltage | 208-240 VAC |
| Output Voltage | 208-240 VAC |
| Frequency | 50/60 Hz (auto-sensing) |
| Waveform | Pure sine wave |
| Battery Type | Sealed lead-acid (VRLA) |
| Battery Capacity | External battery pack compatible |
| Typical Backup Time | 10-15 minutes at full load |
| Number of Outlets | 8 (C13 + C19) |
| Form Factor | Tower / Rack mount 2U |
| Dimensions (HxWxD) | 88 x 438 x 430 mm |
| Weight | 18 kg (without batteries) |
| Cooling | Forced air, variable speed fan |
| Communication Ports | USB, RS-232, SNMP slot |
| LED Indicators | Line, Battery, Fault, Overload |
| Audible Alarms | On battery, low battery, overload |
| Surge Protection | RJ45/11, coax, phone line |
| Operating Temperature | 0-40°C |
| Humidity | 0-95% non-condensing |
| Certifications | CE, UL, EMC |
Frequently Asked Questions - UPS-TRI10K Mach Power
User questions about UPS-TRI10K Mach Power
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Inverter in PDF format for free! Find your manual UPS-TRI10K - Mach Power and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. UPS-TRI10K by Mach Power.
USER MANUAL UPS-TRI10K Mach Power
natural_image
Black industrial power supply unit with ventilation slots and digital display (no visible text or symbols)DATASHEET
UPS ONLINE THREE PHASE
10KVA \~ 30KVA
MOELLO: UPS-TRI10K / UPS-TRI20K / UPS-TRI30K
FEATURES
• High frequency and true online double-conversion
• DSP digitali contrai technology
- Input power factor correction (PFC)
- Wide input voltage range (190V - 485V)
• Output power factor 0.9
- Excellent load-carrying capability, linear derating between 50% and 100% load at 190 - 277 Vac
- Optimized battery configuration: 192V / 240V
- Cold start
• Auto sensing frequency
• ECO mode operation for energy saving
- 50 / 60Hz frequency conversion mode
- Selectable output voltage via LCD
- Selectable battery shutdown voltage (EOD) via LCD
- Power-on self test
• Advanced battery management (ABM)
- Short circuit and overload protection
• Automatic charging in OFF mode
• Auto control fan speed when loads varies
- Dual input
- Advanced quick charge technology, charging speed is increased double
- Configurable transfer time from battery to mains power, reducing the impact on grid or generator
- Automatic startup/shutdown function (optional), automatic transfer to bypass at light load, automatic restart at acting load; energy-saving and environment-friendly
• Standard USB communication port
• Standard emergency power off (EPO)
- Standard maintenance bypass
- Optional extension battery bank
- Optional RS465 I SNMP I AS400 communication port
- Optional N+X redundancy parallel up to 6 units
- Optional battery temperature compensation

SPECIFICATION
| MODEL | UPS-TRI10K | UPS-TRI20K | UPS-TRI30K |
| Capacity | 10KVA / 9KW | 20KVA / 18KW | 30KVA / 27KW |
| INPUT | |||
| Rated voltage | 360 V /380V /400 V/ 415 Vac | ||
| Voltage range | 277 - 485 Vac (no derating) | ||
| 190 - 277Vac (linear derating between 50% and 100% load) | |||
| Rated frequency | 50 / 60 Hz (auto-sense) | ||
| Frequency range | 40 ~ 70 Hz | ||
| Power factor | ≥ 0.99 | ||
| Total harmonic distortion THDI | ≤5% | ||
| Bypass voltage range | -40% - + 15% (settable) | ||
| OUTPUT | |||
| Voltage | 360 V/ 360 V/ 400 V/ 415 Vac (settable) | ||
| Voltage regulation | ±1% | ||
| Frequency | Synchronized with utility in mains mode; 50 / 60 ± 0.1Hz in battery mode | ||
| Waveform | Sinusoidal | ||
| Crest factor | 3:1 | ||
| Total harmonic distortion THDV | ≤ 2% (linear load); ≤ 5% (non-linear load) | ||
| Transfer time | Mains mode to battery mode: 0ms; Inverter mode to bypass mode: 0ms | ||
| Inverter overload capability | 102% - 125%: transfer to bypass in 10 mins; | ||
| Bypass overload capability | 125% - 150%: transfer to bypass in 1 min; | ||
| > 150%: transfer to bypass in 0.5 s | |||
| BATTERIES | |||
| DC voltage | 240 Vdc; Long time model: 192 Vdc | ||
| Inbuilt battery space * | 40 x 9Ah | 40 x 7/9Ah | 60 x 7/9Ah |
| Typical recharge time | 4 Hours | ||
| SYSTEM | |||
| Efficiency | ≥ 93%, ECO mode 96% | ||
| Display | LCD+ LED | ||
| Alarm | Battery mode, low battery, fans fault etc. | ||
* battery not included
| MODEL | UPS-TRI10K | UPS-TRI20K | UPS-TRI30K |
| Max. parallel numbers | 6 | ||
| EMI | IEC I EN62040-2 | ||
| EMS | IEC61000-4-2 (ESD) | ||
| IEC61000-4-3 (RS) | |||
| IEC61000-4-4 (EFT) | |||
| IEC61000-4-5 (surge) | |||
| COMMUNICATIONS | |||
| RS485 / USB I dry contacts | Supports Windows 98 / 2000 / 2003 /XP /Vista/ 2008 / 7 / 8 / 10 | ||
| SNMP (optional) | Power management from SNMP manager and web browser | ||
| OTHERS | |||
| Humidity | 20 - 90% RH@ O ~ 40°C (non-condensing) | ||
| Noise level | ≤ 60 dB (1m) | ≤ 65 dB (1m) | ≤ 65 dB (1m) |
| Dimensions (WxDxH) | 350 x 785 x 868 mm | 350 x 785 x 1078 mm | 350 x 785 x 1078 mm |
| Packaged dimensions (WxDxH) | 472 x 910 x 1050 mm | 472 x 910 x 1260 mm | 472 x 910 x 1260mm |
| Net weight (kg) | 115 | 175 | 235 |
| Gross weight (kg) | 125 | 190 | 250 |
- Derate capacity to 90% when the output voltage is adjusted to 208Vac.
ACCESSORY
External Battery Cabinet for Long Backup (with battery cable and battery breaker)

natural_image
Technical line drawing of a vertical structural frame with horizontal slats and mounting feet (no text or symbols)| MODEL | UPS-BCTRI | UPS-BCTRI-38A |
| Dimension (WxDxH) | 350 x 785 x 1078mm | 950 x 450 x 610mm |
| Battery Capacity | 7groups of 20pcs 7/9Ah | 16/20pcs 38Ah |