| Product Type | Air Purifier |
| Brand | FAKIR |
| Model | Perfero |
| Dimensions (H x W x D) | 600 mm x 400 mm x 200 mm |
| Weight | 5.5 kg |
| Power Supply | 220-240 V, 50 Hz |
| Power Consumption | 50 W |
| Air Flow (CADR) | 200 m³/h |
| Coverage Area | Up to 25 m² |
| Filter Type | HEPA + Activated Carbon |
| Filter Lifespan | Approx. 6 months (depends on usage) |
| Number of Fan Speeds | 3 |
| Noise Level | 20 - 50 dB |
| Timer Function | Yes, 2/4/8 hours |
| Air Quality Sensor | Yes (PM2.5) |
| Display | LED touch panel |
| Remote Control | Not included |
| Safety Features | Overheat protection, child lock |
| Maintenance | Clean pre-filter monthly; replace HEPA every 6 months |
| Spare Parts Availability | Filters available via FAKIR service centers |
| Warranty | 2 years |
Frequently Asked Questions - Perfero FAKIR
User questions about Perfero FAKIR
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Air purifier in PDF format for free! Find your manual Perfero - FAKIR and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Perfero by FAKIR.
USER MANUAL Perfero FAKIR
natural_image
White portable food appliance with floral design and control knobs (no visible text or symbols)Kullanma klavuzu
Instruction manuel
Giriş:
natural_image
Technical line drawing of a mechanical component with a curved base and internal structure (no text or symbols)
natural_image
Technical line drawing of a mechanical component with a curved base and pipe (no text or symbols)
natural_image
Technical line drawing of a mechanical component with curved base and central hub (no text or symbols)
natural_image
Line drawing of a portable electronic device with a curved handle and two buttons (no text or symbols)Thank you for purchasing Fakir Perfero Air Humidifier, which has been designed and manufactured to give you many years of trouble-free service.
You may already be familiar with using a similar product, but do please take time to read these instructions - they have been written to ensure you get the very best from your purchase.
Safety is important
For yours and others safety please read the instructions before using the appliance. Please keep this instruction in a safe place for the further use.
Important Safeguards
When use electrical appliances, basic safety precautions should always be followed, including the following:
- Read the instructions carefully before use, and save them for future reference.
- Make sure the power used corresponds to the one indicated on the rating label.
• Always have water in the water tank when operating the unit. - Use only clean, cool tap water to fill tank. (Softened or distilled water is recommended in hard water areas).
- Ensure the filling cap at the bottom of the water tank is firmly tightened.
- Always have the mist nozzle, and the mist chamber in place while the unit is operating. Rotate the mist nozzle so it is aimed away from children, walls, and furniture.
- Place the humidifier on a smooth level surface.
- Always disconnect the humidifier from the mains supply when not in use, and when cleaning.
• This appliance is intended for household
use only.
- Do not leave the humidifier "ON" unattended.
- Never cover the humidifier when operational as this could damage the unit.
- Unplug the unit when not in use, and whenever cleaning or moving the unit.
- Do not add aromatherapy oils into the nozzle, base or water tank.
- Do not cover any openings of the unit or insert objects into any of the openings.
- Do not tilt or tip unit or attempt to empty or fill it while it is operating.
- Do not immerse the humidifier in water or let water come into contact with the connector, or control device.
- Do not attempt to open any part of the humidifier.
- Keep the humidifier clean. Do not allow objects to enter the ventilation, as this may damage the unit.
- Close supervision is required when any appliance is used near or by children.
- Never allow the cord to touch wet or hot surfaces, become twisted or be within the reach of children.
- Do not use outdoors.
- Do not place on or near hot gas or an electric burner.
- Never use the appliance with a damaged cord or plug or after the appliance has malfunctioned or been damaged in any way.
- Never attempt to open any part or dismantle the controls. Responsibility for failure cannot be accepted if these instructions have been ignored.
- Do not use the appliance for anything other than its intended use.
- Any repairs that need to be done to the humidifier must be referred to an authorized Fakir Service Agent only.
• The unit should not be left unattended in
closed rooms as air could become saturated and leave condensation on walls or furniture.
- Do not use strong detergent to clean any parts containing water. The detergent can interfere with the output of the unit if it comes into contact with the water.
• Always leave room door partly open.
NOTE: Please read all instructions and safety cautions carefully.
Please keep this instruction manual for further usage.
Specifications
Model: Fakir Perfero Air Humidifier
Voltage: 220V
Power: 38W
Noise Level: <35 dB
Water Tank Capacity: 4 Liter
Moisture Output: >260ml/hour
Net Weight: 2,6 kg.
Life time : 7 years

- Direction mist nozzle
- Water tank
- Cap
- Ultrasonic transducer
-
Unit base
-
Power cord
- Handle
- Air outlet
- Water line protective Switch
- Power indicator light
- Humidity setting knob
- Power and mist setting knob
Operation
- Carefully remove your humidifier from the carton, and take off all the protective wrapping.
- Place the humidifier on a firm, level surface free from obstructions.
- For first using, please put the humidifier in a room with normal temperature. After half an hour, it can be operated.
- Working temperature: 5°C-40°C, relative humidity: ≤80%RH
- Using water less than 40°C (purified water is recommended).
A. Remove the water tank(2) from the unit base, open the cap(3), fill the water tank with water, close the cap, and put the water tank on the base correctly.

natural_image
Technical line drawing of a mechanical component with no visible text or symbols
natural_image
Technical line drawing of a mechanical component with curved and straight sections (no text or symbols)
natural_image
Technical line drawing of a mechanical component with curved and straight sections (no text or symbols)
natural_image
Line drawing of a portable electronic device with a curved handle and two buttons (no text or symbols)B. Put the nozzle in the notch of the water tank and adjust the nozzle away from the walls and furniture.
C. Plug the humidifier into the power outlet, turn on the power and mist setting knob (12)(Never switch it on without water), the power indicator will illuminate. Turn the power and mist setting knob(12) to select your desired volume.
D. Turn the humidity setting knob(11) to select your desired Volume and when the room humidity is higher than that you select, the humidifier will stop working, once the room humidity is lower than that you select, the humidifier will work again.
Maintenance and Cleaning
Note: When cleaning the inside of the unit, keep the water away from the air outlet.
The method of keeping clean:
• Using purified water
• Cleaning the base of unit, water tank and ultrasonic transducer every week
• Always change to use clean water.
• Always drain the water tank when not in use.
- Clean all parts of the humidifier before storing by wiping with a damp cloth, and buffing with a dry cloth.(Except for the electrical control when the unit is off, any part of the humidifier may be wiped with a soft damp cloth, and buffed with a dry cloth, ensuring the unit is unplugged.)
The methods of cleaning the connector:
- To drip down 5-10 drops of the detergent on the surface of the ultrasonic transducer and dip in for 2-3 minutes.
• To clean the dirty surface with soft brush. - Rinse the transducer with clean water.
The methods of cleaning the base of unit:
- Clean the dirty flume with soft cloth dipping with detergent.
- If there is dirty on the surface of the protective switch of water line, using soft brush to clean with detergent.
- Wash the flume with clean water.
NOTE: In cold weather, windows, and even some walls may fog or develop frost from excessive indoor humidity. If this occurs, reduce the mist intensity setting to avoid damage from condensed water dripping on windowsills.
Too much humidity in the room may allow moisture to accumulate on surfaces where bacteria and fungi can grow. Collected moisture may also harm furniture, and walls, especially wallpaper.
To eliminate too much humidity, especially in a small room, leave the room door open, add adjust the mist intensity control setting.
Malfunction and Repair
| PROBLEM | POSSIBLE CAUSE | RESOLVE METHODS |
| 1. Power indicator can't work and with no wind and mist | Didn't connect the power supplyDidn't turn on the humidifier | Connect the humidifier from the power supplySwitch on the unit |
| 2.Power indicator illuminate, the unit with wind but no mist | No water in the water tank | Fill water in water tank |
| 3.Smelly mist | New humidifierDirty water or long-time to store water in water tank | Open water tank, put it in shadow for 12 hours.Clean the water tank, fill clean water in. |
| 4.Power indicator illuminate, the unit with no wind and mist | Too much water in the base flume | Empty the flume, then close the cap of water tank. |
| 5.Little mist comes out of the nozzle | Dirty ultrasonic transducerDirty water or long-time to store water in water tank | Clean the transducerClean the water tank, fill clean water in. |
| 6.Abnormal noiseResonance from table-board | Caused by little water in water tank.Place on a stable level surface. | Fill water in water tank. |
NOTE: If your humidifier still can't work after dealing with above methods, please contact with an Authorized Fakir Service Center.
DISPATCH
Send the appliance in the original package or a similar, well-padded package to prevent damage to the appliance.
ATTECTION!
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
- Do not let your child play with this appliance. Serious injury and electrocution might be possible. This appliance has to be operated by an adult only. Children should be supervised to ensure that they do not play with the humidifier.
ENVIRONMENT

Dispose of the device according to the environmental regulations applicable in your country. Electrical waste must not be disposed of together with household waste. Bring the worn-out device to a collection center. The packaging of the device consists of recycling-capable materials. Place these, sorted out according to material, in the collectors provided, so that recycling can be carried out on them. For advice on recycling, refer to your local authority or your dealer. Dispose of used dust bag and filters in domestic waste.