BPW-410-WGN - Blood pressure monitor Walgreens - Free user manual and instructions
Find the device manual for free BPW-410-WGN Walgreens in PDF.
| Product Type | Automatic Wrist Blood Pressure Monitor |
| Brand | Walgreens by HoMedics |
| Model | BPW-410-WGN |
| Measurement Method | Oscillometric |
| Measurement Range (Pressure) | 40–250 mmHg |
| Measurement Range (Pulse) | 40–199 beats/min |
| Accuracy (Pressure) | ±3 mmHg |
| Accuracy (Pulse) | ±5% of reading |
| Power Source | 2 AAA alkaline batteries (1.5V each) |
| Memory Capacity | 60 readings per user (120 total for 2 users) |
| Inflation | Automatic pump driven (Smart Sense™ technology) |
| Deflation | Automatic pressure release valve |
| Risk Category Indicator | Yes (Normal, Prehypertension, Stage 1, Stage 2 Hypertension) |
| Irregular Heartbeat Detector | Yes |
| Wrist Circumference Range | 5.3–8.6 inches (13.5–22 cm) |
| Dimensions (L x W x H) | 2.9 x 2.6 x 3.2 inches (73 x 65 x 82 mm) |
| Weight (without batteries) | 0.30 lbs (140 g) |
| Operating Environment | 50–104°F (10–40°C), 40–85% RH |
| Storage Environment | 14–140°F (-10–60°C), 10–90% RH |
| Auto Shut-off | 1 minute after last operation |
| Warranty | Lifetime limited warranty (valid in USA only) |
| Recalibration | Recommended after 2 years (fee applies) |
Frequently Asked Questions - BPW-410-WGN Walgreens
User questions about BPW-410-WGN Walgreens
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Blood pressure monitor in PDF format for free! Find your manual BPW-410-WGN - Walgreens and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. BPW-410-WGN by Walgreens.
USER MANUAL BPW-410-WGN Walgreens
Walgreens by HOMEDICS
Walgreens by HOMEDICS
Correo: HoMedics, Inc. Service Center Dept. 168 3000 Pontiac Trail Commerce Township, MI 48390
Correo electrónico: cservice@ homedics.com
Automatic Wrist Blood Pressure Monitor

lifetime limited warranty
TABLE OF CONTENTS
INTRODUCTORY INFORMATION:
Important Product Notices and Safety Instructions ....3
About Blood Pressure ....6
What is Blood Pressure?
Why Measure Your Blood Pressure?
Blood Pressure Standard .....7
How This Blood Pressure
Monitor Works ....8
USAGE INFORMATION:
Name/Function of Each Part .....10
Display Explanations .....11
Installing Batteries .....13
Date & Time Set Procedure .....15
Applying the Cuff .....15
Correct Measurement Posture .....17
Measurement Procedure .....18
Risk Category Indicator .....22
Irregular Heartbeat Detector .....23
Recalling Values from Memory .....24
Clearing Values from Memory .....25
Important Notes Regarding Your Blood Pressure Measurement .....26
Recalibration Service .....27
Care, Maintenance & Cleaning .....28
Potential for Radio/Television Interference ....30
Troubleshooting ....32
Specifications ....33
Lifetime Limited Warranty .....34
Walgreens by HOMEDICS
IMPORTANT PRODUCT NOTICES AND SAFETY INSTRUCTIONS
When using your blood pressure monitor, basic precautions should always be followed. Please read and follow all instructions and warnings before using this product. Save these instructions for future reference.
- Please note that this is a home health-care product only and it is not intended to serve as a substitute for the advice of a physician or medical professional.
-
Do not use this device for diagnosis or treatment of any health problem or disease. Measurement results are for reference only. Consult a healthcare professional for interpretation of pressure measurements. Contact your physician if you have or suspect any medical problem. Do not change your medications without the advice of your physician or healthcare professional.
-
This product is not suitable for people with arrhythmias. This device may have difficulty determining the proper blood pressure for individuals with diabetes, poor circulation of blood, kidney problems or for users who have suffered from a stroke.
- Consult your physician before measuring blood pressure at the wrist if you have any of the following conditions: Severe hypertension, severe diabetes, severe arteriosclerosis, severe kidney disease or vascular disease that may compromise circulation.
- The pulse display is not suitable for checking the frequency of heart pacemakers.
-
Electromagnetic interference: The device contains sensitive electronic components. Avoid strong electrical or electromagnetic fields in the direct vicinity of the device (e.g. mobile telephones, microwave ovens). These may lead to temporary impairment of measurement accuracy.
-
Use blood pressure monitor only for its intended use.
- Do not wrap the cuff around body parts other than your wrist.
- This unit is intended for use in measuring the blood pressure and pulse rate of adults. Do not use this device on infants or those who cannot express their own consent. This unit should not be operated by children.
Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope ausculatory method, within the limits prescribed by the American National Standard, Manual, electronic, or automated sphygmomanometers.
ABOUT BLOOD PRESSURE What is Blood Pressure?
Blood pressure is the pressure exerted on the artery walls while blood flows through the arteries. The pressure measured when the heart contracts and sends blood out of the heart is systolic (highest) blood pressure. The pressure measured when the heart dilates with blood flowing back into the heart is called diastolic (lowest) blood pressure.
Why Measure Your Blood Pressure?
Among today's various health problems, those associated with high blood pressure are very common. High blood pressure dangerously correlates with cardiovascular diseases. Therefore, blood pressure monitoring is important for identifying those at risk.
BLOOD PRESSURE STANDARD
The U.S.Department of Health and Human Services and the National Institutes of Health have developed a blood pressure standard that identifies areas of low- and high-risk blood pressure. This standard, however, is a general guideline as blood pressure varies among different people, age groups, etc.
Categories for Blood Pressure Levels in Adults
| Systolic (mmHg) | Diastolic (mmHg) | |
| Stage 2 Hypertension | >160 _ | >100 _ |
| Stage 1 Hypertension | 1 4 0~159 | 90~99 |
| Prehypertension | 120~139 | 80~89 |
| Normal | <120 | <80 |
For adults 18 and older who are not on medicine for high blood pressure, are not having a short-term serious illness, and do not have other conditions, such as diabetes and kidney disease.
To determine category of risk when systolic and diastolic readings fall into two areas, use the higher of the two numbers for classification.
There is an exception to the above definition of high blood
pressure for people with diabetes and chronic kidney disease.
A blood pressure of 130/80 mmHg or higher is considered high blood pressure for those individuals.
This monitor comes equipped with a Risk Category Indicator to visually indicate the assumed risk level of each reading based upon these standards. See page 22 for more information on this feature.
It is important that you consult with your physician regularly. Your physician will tell you your normal blood pressure range as well as the point at which you will be considered at risk. For reliable monitoring and reference of blood pressure, keeping long-term records is recommended.
HOW THIS BLOOD PRESSURE MONITOR WORKS
This monitor uses Smart Sense™ technology to detect your blood pressure. With one touch of a button, the cuff will automatically inflate to block the blood flow through your artery. Next, the deflation process starts. Smart Sense™ technology enables the monitor to automatically inflate and deflate to the appropriate level for each individual. Please note that any muscle movement during inflation or deflation will cause measurement error. When measurement is complete, the monitor will
display your systolic pressure, diastolic pressure, and pulse readings.
Based upon your measurement results, the monitor's Risk Category Indicator will alert you if your reading falls into the pre-hypertension, stage 1 hypertension, or stage 2 hypertension categories. See page 22 for more information on the Risk Category Indicator.
This monitor also features an irregular heartbeat (IHB) detector that will alert the user to the presence of an irregular heartbeat. It is strongly recommended that you consult your physician if the IHB symbol IHB appears often (five times or more in a row). See page 23 for more information on the IHB Detector.
NAME/FUNCTION OF EACH PART

Accessories for unit :

2 "AAA" size, 1.5V alkaline batteries included in the carrying case with the unit.
DISPLAY EXPLANATIONS

Date/Time Indicator
Display Symbols:
| [2T8W] | User 1: Appears when the monitor is operated by User 1. |
| [YY40] | User 2: Appears when the monitor is operated by User 2. |
![]() | Weak Battery Symbol: Appears when batteries should be replaced. |
![]() | Pulse Symbol: Shows the pulse rate per minute. |
![]() | Irregular Heartbeat Detector: Indicates an irregular heartbeat was detected. See page 23 for more information. |
![]() | Memory Average: Displays average of last 3 readings |
![]() | Risk Category Indicator: Compares readings against blood pressure guidelines. See page 22 for more information. |
If any of the following letters and numbers appear in the area that diastolic pressure should be displayed, an error has occurred with your reading. See Troubleshooting section of this manual for more information.
| EE | Measurement Error: Measure again. Wrap the cuff correctly and keep wrist steady during measurement. |
| E1 | Air Circuit Abnormality: Measure again. |
| E2 | Pressure Exceeding 300 mmHg: Switch the unit off to clear, then measure again. |
| E3 | Data Error: Remove and reload the batteries. |
| -- | Recalibration Alert: Recalibration recommended. See page 27 for information. |
INSTALLING BATTERIES
-
The battery cover is located along the top side of the monitor. Remove battery cover by pressing in on sides and pulling away from the monitor.
-
Install lower battery first according to the polarity indications inside the compartment. This battery should be in the bottom position as shown in figure 2.
Battery Type: 2 Alkaline LR03 (AAA) size
- Place in the other battery, according to the polarity indications inside the compartment and as shown in figure 3.

natural_image
Diagram of a mechanical or anatomical structure with an arrow indicating a specific region (no text or symbols present)
natural_image
Diagram of a hand holding a battery with a pen, no text or symbols present
natural_image
Illustration of a hand holding a battery with a positive charge (no text or symbols)- Replace the cover by inserting it back into place.
Replace the batteries if:
-
The weak battery symbol appears in the display.
-
Nothing appears in the display when the power is switched on.
As the supplied batteries are for test only, they may be discharged earlier than batteries you buy in stores. Replace the batteries in pairs. Remove batteries when unit is not in use for extended periods of time.
Note: Batteries are hazardous waste. Do not dispose of them together with the household garbage.

natural_image
Diagram of a hand holding a curved object with an arrow pointing to it, no text or symbols presentDATE & TIME SET PROCEDURE
- To adjust the date/time, press the Set button ^© located on the side of the monitor. The display will show a blinking number showing the hour.
- Change the hour by pressing the button. Each press will increase the number by one in a cycling manner. Press the Set button again to confirm the entry, and the screen will show a blinking number representing the minutes.
- Change the time and date as described in Step 2 above, using the + button to change the numbers and the Set button to confirm the entries.
- A "0" will reappear as the blood pressure monitor is ready for measurement again.

flowchart
graph TD
A["Press the @button"] --> B["blinking hour"]
B --> C["increasing hour"]
C --> D["confirm the entry"]
D --> E["repeat process to set time and date"]
APPLYING THE CUFF
-
Remove all watches, wrist jewelry, etc. prior to attaching the wrist monitor. Clothing sleeves should be rolled up and the cuff should be wrapped around bare skin for correct measurements.
-
Apply cuff to left wrist with palm facing up as shown in Fig. A.
- Make sure the edge of the cuff is about 1/4"\~1/2" (1 cm) from the palm as shown in Fig. B.
- In order to insure accurate measurements, fasten the hook and loop strap securely around your wrist so there is no extra space between the cuff and the wrist as shown in Fig. C. If the cuff is not wrapped tight enough, the measurement values will not be accurate.
- If your physician has diagnosed you with poor circulation in your left arm, place the cuff around your right wrist as shown in Fig. D.
Fig. A

Fig. B

Fig. C

Fig. D

CORRECT MEASUREMENT POSTURE
- Place your elbow on a table so that the cuff is at the same level as your heart as shown in Fig. A.
Note: Your heart is located slightly below your armpit.
Relax your entire body, especially between your elbow and fingers. - If the cuff is not at the same level as your heart or if you cannot keep your arm completely still throughout the reading, use a soft object such as a folded towel to support your arm as shown in Fig. B.
- Turn you palm upwards.
- Sit upright in a chair, and take 5-6 deep breaths.
Avoid leaning back while the measurement is being taken as shown in Fig. C.



MEASUREMENT PROCEDURE Important Notes:
- Position the monitor at the same level as your heart during measurement to ensure accurate readings.
- Blood pressure changes with every heartbeat and is in constant fluctuation throughout the day.
- Blood pressure measurement can be affected by the position of the user, his or her physiologic condition and other factors. For greatest accuracy, wait 1 hour after exercising, bathing, eating, drinking beverages with alcohol or caffeine, or smoking to measure blood pressure.
- Before measurement, it is suggested that you sit quietly for 15 minutes as measurements taken during a relaxed state will have greater accuracy. You should not be physically tired or exhausted while taking a measurement.
-
During the measurement, do not talk or move your arm or hand muscles.
• See page 26 for additional notes regarding your blood pressure measurement -
Press the User Select Button to choose User 1 or User 2.

flowchart
graph LR
A["8/8"] --> B["18"]
B --> C["28"]
style B fill:#f9f,stroke:#333
note right of B OR
After the user number is selected, press the START/STOP button to confirm the chosen user.
- With the cuff wrapped around your wrist, press the START/STOP button. Do not inflate the cuff unless it is wrapped around your wrist. All digits will light up, checking the display functions. The checking procedure will be completed after about 2 seconds.

- After all symbols disappear, the display will show a blinking "0". The monitor is "Ready to Measure" and will automatically inflate the cuff to begin measurement. The cuff will then begin deflating as measurement continues.

Note: The monitor will re-inflate automatically if the system detects that your body requires more pressure for measurement.

- When the measurement is completed, the cuff wil deflate entirely and systolic pressure, diastolic pressure and pulse will be shown simultaneously on the LCD screen. The measurement is then automatically stored into memory.

Note:
-
This monitor automatically turns off approximately 1 minute after last operation. You may also press the START/STOP button to turn the unit off.
-
To interrupt the measurement, you may press the START/STOP button (recommended) or the Memory, User Select, or Date/Time Set (◎) buttons. The cuff will deflate immediately after a button is pressed.
RISK CATEGORY INDICATOR
The U.S. Department of Health and Human Services and the National Institutes of Health have developed a blood pressure standard, classifying blood pressure ranges into 4 stages. This unit is equipped with an innovative blood pressure classification indicator, which visually indicates the assumed risk level (normal, prehypertension, stage 1 hypertension, or stage 2 hypertension) of each reading. Symbols are described below and classifications follow the guidelines as described earlier in this manual (page 7).

Stage 2 Hypertension

Pre-hypertension

Stage 1 Hypertension
Normal (No Symbol)
IRREGULAR HEARTBEAT DETECTOR
An irregular heartbeat may cause or indicate cardiovascular disease. This monitor features advanced technology to alert the user to the presence of an irregular heartbeat for better health monitoring.
The appearance of this symbol, ^138 , signifies that an irregular heartbeat was detected. This is only a caution. Note that it is important that you be relaxed, remain still and do not talk during measurements.
Note: It is strongly recommended that you consult your physician if the irregular heartbeat symbol, HB, appears often (five times or more in a row).

23
RECALLING VALUES FROM MEMORY
This monitor can be used by two individuals. Each user can store up to 60 measurements.
- Press the User-Select button.

- Choose User 1 or User 2.

- Press the "MEM" button to access the memory.

- The monitor will first display the calculated average applied to the last 3 memories ("AVG. 3").

- Every new press of the "MEM" button will recall a previous reading. The latest reading will be recalled first.

24
CLEARING VALUES FROM MEMORY
- Press the User-Select button to select User 1 or User 2.

- Continue to press the "MEM" button for approximately 5 seconds, then the data for the selected user will be erased automatically.

Note: The data stored in memory for both users may be erased if any of the batteries are removed. (Users should first record the data in a Blood Pressure log before replacing or removing batteries.)
IMPORTANT NOTES REGARDING YOUR BLOOD PRESSURE MEASUREMENT
• Take your reading in a comfortable environment as measurements can be affected by hot or cold temperatures. Take your blood pressure at normal body temperature.
- Do not move or talk during measurement as this can elevate readings.
- Do not move or cross legs during measurement. Keep feet flat on floor.
- Do not touch cuff or monitor during measurement procedure.
- It is suggested that you take your measurements at the same time each day and use the same arm for consistency.
- Users should wait a minimum of 5 minutes before taking additional measurements. More time may be necessary depending upon your physiology.
- The measurement results that users receive are for reference only. If users have any blood pressure concerns, please consult a physician.
- Once inflation reaches 300 mmHg, the unit will deflate automatically for safety reasons.
- This product is not suitable for people with arrhythmias.
- This device may have difficulty determining the proper blood pressure for users with diabetes, poor circulation of blood, kidney problems, or for users who have suffered a stroke.
RECALIBRATION SERVICE
All digital blood pressure monitors require recalibration in order to ensure continued accuracy.
This monitor does not require recalibration for 2 years under normal usage conditions (approximately 3 times per day), at which time your monitor will display “--”. The unit should also be recalibrated if the monitor sustains damage due to blunt force (such as dropping) or exposure to fluids or extreme hot or cold temperature changes.
Please fill in date of first use ____
(Recalibration is recommended after 2 years.)
To send monitor for recalibration, please ship to the address below with a check or money order in the amount of \$10 payable to HoMedics, Inc. for recalibration service and shipping & handling:
HoMedics Recalibration Service Center
P.O. Box 7050
Walled Lake, MI 48390
Allow up to 3 weeks for return of product. For additional information, contact HoMedics Consumer relations at 1-800-466-3342.
CARE, MAINTENANCE & CLEANING
- Clean the blood pressure monitor body and cuff carefully with a slightly damp, soft cloth. Do not press. Do not wash cuff or use chemical cleaner on it. Never use thinner, alcohol or petrol (gasoline) as cleaner.
- Leaky batteries can damage the unit. Remove the batteries when the unit will not be used for a long time.
-
If the unit is stored near freezing, allow it to acclimate to room temperature before use.
-
This blood pressure monitor is not field serviceable. You should not use any tool to open the device nor should you attempt to adjust anything inside the device. If you have any problems with this device, please contact HoMedics Consumer Relations (contact information on warranty page).
- Do not immerse the unit in water as this will result in damage to the unit.
- Do not subject the monitor and cuff to extreme temperatures, humidity, moisture, and direct sunlight. Protect from dust.
- Do not fold the cuff tightly.
- Do not disassemble the monitor or cuff. If in need of repair, refer to the warranty section of this manual.
- Do not subject the monitor to extreme shocks (do not drop on floor).
- Do not inflate the cuff unless wrapped around wrist.
-
Do not wrap the cuff around body parts other than your wrist.
-
Do not drop or insert any object into any opening.
- This monitor may not meet its performance specifications if stored or used outside of these temperature and humidity ranges:
- Storage Environment Temperature: - Operation Environment Temperature:
14^ 140^
(-10^ 60^)
50^ 104^
(10°C \~40°C)
Humidity:
10\~90% RH max.
Humidity:
40\~85% RH max.
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE
For USA only
This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of FCC rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. The product generates, uses, and can radiate radio frequency energy and, if not used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the product does cause harmful interference to radio or tele-
vision reception, which can be determined by turning the product on and off, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the product and the receiver.
- Consult the dealer or an experienced radio/TV technician for help.
For Canada only
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled “Digital Apparatus”, ICES-003 of the Canadian Department of Communications.
If any abnormality arises during use, please check the following points:
| SYMPTOMS | POSSIBLE CAUSES | CORRECTION |
| Unit does not turn on when the START/STOP button is pushed. | Batteries have run down. | Replace them with two new AAA alkaline batteries. |
| Battery polarities have been positioned incorrectly. | Re-insert the batteries in the correct positions. | |
| EE measurement error symbol shown on display or the blood pressure value is displayed excessively low (or high). | Cuff has been placed incorrectly. | Wrap the cuff properly so that it is positioned correctly. |
| Did you talk or move during measurement? | Measure again.Keep wrist steady during measurement. | |
| Shaking of the wrist with the cuff on. | ||
| E1 error symbol shown on display | Air circuit abnormality. | Measure again. |
| E2 error symbol shown on display | Inflation pressure exceeding 300 mmHg. | Switch the unit off, then measure again. |
| E3 error symbol shown on display | Data error. Remove and reload the batteries. | |
| -- appears on display | Recalibration alert. | Refer to page 27 for more information. |
Note: If the unit still does not work, contact HoMedics Consumer Relations. Under no circumstance should you disassemble or attempt to repair the unit by yourself. Contact information for HoMedics Consumer Relations Department can be found on the warranty page (See page 34).
SPECIFICATIONS
| Power Source: | Two 1.5V DC (AAA) Alkaline batteries |
| Measurement Method: | Oscillometric |
| Measurement Range: | Pressure: 40~250 millimeters Mercury (mmHg)Pulse: 40~199 beats/minute |
| Accuracy: | Pressure: ±3 mmHgPulse: ±5% of reading |
| Pressure Sensor: | Semi-conductor |
| Inflation: | Pump driven |
| Deflation: | Automatic Pressure release valve |
| Memory Capacity: | 60 memories for each User (120 total) |
| Auto-shut-off: | 1 minute after last button operation |
| Operation Environment: | Temperature: 50°F~104°F (10°C~40°C)Humidity: 40%~85% RH max. |
| Storage Environment: | Temperature: 14°F~140°F (-10°C~60°C)Humidity: 10%~90% RH max. |
| Weight: | 0.30 lbs (140 g) (without batteries) |
| Wrist Condition: | 5.3" - 8.6" (13.5 - 22cm) |
| Dimensions: | 2.9"(L) x 2.6"(W) x 3.2"(H)73mm(L) x 65mm(W) x 82mm(H) |
| Type BFDevice and cuff are designed to provide special protection against electrical shocks. |
Note: These specifications are subject to change without notice.
Walgreens by HOMEDICS
For service or repair, do not return this unit to the retailer. Contact HoMedics Consumer Relations at:
Mail:
HoMedics, Inc.
Service Center Dept.
168
3000 Pontiac Trail
Commerce Township,
Mki
48390
Email:
cservice@
homedics.com
Phone:
1-800-466-3342
Business Hours:
8:30am-5pm ET
Monday-Friday
Distributed By:
Walgreen
Company
Deerfield, IL
60015-4681
Printed in China
LIFETIME LIMITED WARRANTY (Valid in USA only)
HoMedics sells its products with the intent that they are free of defects in manufacture and workmanship for the life of the original purchaser from the date of original purchase, except as noted below. HoMedics warrants that its products will be free of defects in material and workmanship under normal use and service. This warranty extends only to consumers and does not extend to Retailers.
To obtain warranty service on your HoMedics product, mail the product and your dated sales receipt (as proof of purchase), postpaid, to the following address:
HoMedics Consumer Relations
Service Center Dept. 168
3000 Pontiac Trail
Commerce Township, MI 48390
No COD's will be accepted
HoMedics does not authorize anyone, including, but not limited to, Retailers, the subsequent consumer purchaser of the product from a Retailer or remote purchasers, to obligate HoMedics in any way beyond the terms set forth herein. This warranty does not cover damage caused by misuse or abuse; accident; the attachment of any unauthorized accessory; alteration to the product; improper installation; unauthorized repairs or modifications; improper use of electrical/power supply; loss of power; dropped product; malfunction or damage of an operating part from failure to provide manufacturer's recommended maintenance; transportation damage; theft; neglect; vandalism; or environmental conditions; loss of use during the period the product is at a repair facility or otherwise awaiting parts or repair; or any other conditions whatsoever that are beyond the control of HoMedics.
This warranty is effective only if the product is purchased and operated in the country in which the product is purchased. A product that requires modifications or adoption to enable it to operate in any other country than the country for
lifetime limited warranty
Walgreens by HOMEDICS
Walgreens by HOMEDICS
For service or repair, do not return this unit to the retailer. Contact HoMedics Consumer Relations at:
Mail: HoMedics, Inc. Service Center Dept. 168 3000 Pontiac Trail Commerce Township, M:11 48390
Email: cservice@ homedics.com
Phone: 1-800-466-3342 Business Hours: 8:30am-5pm ET Monday-Friday
Distributed By: Walgreen Company Deerfield, IL 60015-4681 Printed in China
which it was designed, manufactured, approved and/or authorized, or repair of products damaged by these modifications is not covered under this warranty. THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY. THERE SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS OR ANY OTHER OBLIGATION ON THE PART OF THE COMPANY WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY. HOMEDICS SHALL HAVE NO LIABILITY FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES. IN NO EVENT SHALL THIS WARRANTY REQUIRE MORE THAN THE REPAIR OR REPLACEMENT OF ANY PART OR PARTS WHICH ARE FOUND TO BE DEFECTIVE WITHIN THE EFFECTIVE PERIOD OF THE WARRANTY. NO REFUNDS WILL BE GIVEN. IF REPLACEMENT PARTS FOR DEFECTIVE MATERIALS ARE NOT AVAILABLE, HOMEDICS RESERVES THE RIGHT TO MAKE PRODUCT SUBSTITUTIONS IN LIEU OF REPAIR OR REPLACEMENT.
This warranty does not extend to the purchase of opened, used, repaired, repackaged and/or resealed products, including but not limited to sale of such products on Internet auction sites and/or sales of such products by surplus or bulk resellers. Any and all warranties or guarantees shall immediately cease and terminate as to any products or parts thereof which are repaired, replaced, altered, or modified, without the prior express and written consent of HolMedics. This warranty provides you with specific legal rights. You may have additional rights which may vary from country to country. Because of individual country regulations, some of the above limitations and exclusions may not apply to you.
For more information regarding our product line in the USA, please visit: www.homedics.com
©2007 HoMedics, Inc. and its affiliated companies, all rights reserved. HoMedics is a registered trademark of HoMedics, Inc. and its affiliated companies. Smart Sense™ is a trademark of HoMedics Inc. and its affiliated companies. All rights reserved.
IB-BPW410WGN-B
lifetime limited warranty
Walgreens by HOMEDICS
natural_image
Diagram of a curved mechanical component with an arrow indicating direction (no text or symbols)
natural_image
Diagram of a hand holding a battery with a pen inserted, no text or symbols present
natural_image
Illustration of a hand holding a battery with a resistor (no text or symbols)natural_image
Diagram of a hand holding a cylindrical object with an arrow indicating rotation (no text or symbols present)natural_image
Line drawing of a person sitting at a desk using a cup and pen, with no text or symbols present.Fig. B

natural_image
Line drawing of a person sitting at a table with a heart symbol on the arm, no text or symbols presentCÓMO RECUPERAR LOS VALORES DE LA MEMORIA
HoMedics Recalibration Service Center
P.O. Box 7050
Walled Lake, MI 48390
Walgreens by HOMEDICS
Por servicio
o reparación
no devuelva esta
HoMedics Consumer Relations
Service Center Dept. 168
3000 Pontiac Trail
Commerce Township, MI 48390




