Product type Portable monoblock air conditioner
Brand SereneLife
Model SLPAC12
Cooling capacity 12,000 BTU (ASHRAE)
Coverage area Up to 37 m² (400 sq ft)
Rated power 1370 W
Power supply 220-240 V ~ 50 Hz
Dimensions (L × D × H) 44.1 × 34 × 81.5 cm
Air flow rate 360 m³/h
Noise level 65 dB(A)
Number of modes 3 (Cooling, Fan, Dehumidification)
Fan speeds 3 (Low, Medium, High)
Dehumidification capacity 1.2 L/h
Refrigerant gas R290, 245 g
Timer Programmable up to 24 h
Air filter Removable and washable
Temperature setting 16 °C to 30 °C (display in °C/°F)
Remote control Yes (with included AAA batteries)
Power cable length 1.31 m
Window installation kit Included (sealing plate and exhaust hose)
Casters Yes, for easy transport

Frequently Asked Questions - SLPAC12 SereneLife

How to install the SLPAC12 air conditioner?
Place the unit at least 50 cm from walls and objects. Screw the exhaust hose into the rear air outlet (counterclockwise). Insert the hose into the adjustable window sealing plate. Plug the unit into a 220-240 V earthed outlet. Wait 2 hours upright before first start.
What to do if the screen shows 'FL'?
The 'FL' code indicates the internal tank is full. Turn off and unplug the unit, then unscrew the drain cap at the back to drain the water. Plug back in and restart; the unit returns to normal.
How to clean the air filter?
Unplug the unit. Remove the air intake grille and take out the filter. Vacuum or wash with warm water (40 °C max) and mild detergent. Dry in the shade before reinstalling. Clean every two weeks.
Can I use an extension cord?
No, using an extension cord is prohibited. Plug the air conditioner directly into a suitable wall outlet (220-240 V, 50 Hz, with earth). If necessary, have a qualified electrician install an outlet.
What are the operating modes?
The SLPAC12 offers three modes: Cooling (adjustable from 16 to 30 °C), Fan (3 speeds, no temperature setting), and Dehumidification (humidity extraction, compressor active if ≥ 17 °C). An Auto mode is also available on some models.
How to set the timer?
In standby, press 'Timer' to set the start time (1 to 24 h). In operation, press 'Timer' to set the stop time. Use the up/down arrows to adjust. The 'Timer' indicator lights up.
The air conditioner does not turn on, what to do?
Check the power supply: reset the circuit breaker if necessary. Ensure the unit has been off for at least 3 minutes before restarting (compressor protection). If the screen remains off, contact a professional.
What type of refrigerant gas is used?
The air conditioner uses R290 (propane) refrigerant, an eco-friendly refrigerant with a low GWP of 3. The charge is 245 g. Ensure a room area of at least 12 m² and avoid sources of ignition.
How to drain water in dehumidification mode?
Remove the cap from the dehumidification nozzle (at the back) and attach a drain hose (not included) to a container or drain. Water will flow by gravity. Ensure the hose is not kinked.
What to do in case of abnormal noise?
Check that the unit is on a flat and stable floor. Ensure no objects obstruct the air intakes/outlets and that the filter is clean. If the noise persists, turn off the unit and contact a professional.

User questions about SLPAC12 SereneLife

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air-conditioner in PDF format for free! Find your manual SLPAC12 - SereneLife and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SLPAC12 by SereneLife.

USER MANUAL SLPAC12 SereneLife

natural_image White and black portable air conditioner unit with ventilation slots (no visible text or symbols)

SLPAC12.5EU-SLPAC12.5UK

Portable Air Conditioner

Compact Home AC Cooling Unit with Built-in Dehumidifier & Fan Modes, Includes Window Mount Kit (12,000 BTU)

USER GUIDE

QR code image containing encoded data, no visible human-readable text

For user guides in multiple languages,

SCAN THE QR CODE

and enter your model number

serenelife™

CONTENT

Important Safety Tips

Precautions....3

Product Introduction

Main Parts and Components....7

Control Panel and Remote Controller....9

Product Operation

Placement and Installation....10

Operation Method....11

Clean and Maintenance

Drainage Method....12

Maintenance....13

Common Failures and Diagnosis

Intelligent Error Detection....14

Fuse Parameters....14

Troubleshooting....14

Features and Technical Specifications ....15

Important Safety Tips

Precautions

Please read the Manual carefully before operating the machine:

• This machine is for household use only.
• This machine is for indoor use only. Please place it in dry environment.
- Check power cord frequently. If power cord, plug or A/C is damaged, please don't operate. Cable should not scatter at places where power cord may be pulled out or people may be stumbled.

• The A/C should be away from heat source and avoid direct sunlight.

- Turn off the A/C before unplugging.

- Turn off and unplug the A/C before removing or cleaning it, or replacing its parts or when it is not used.

- Clean the A/C according to the Manual.

- Voltage of the A/C should meet requirements. Any damage incurred by incorrect power isn't included in the warranty.

• Children are not allowed to play with the A/C.

This appliance is not intended for use by children, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

- Don’t insert your fingers or any hard object to wind guide bar of the air outlet.

- Don't place the A/C at any place with water or other liquid. Prevent water or liquid from entering the A/C.

- Don’t repair the A/C by yourself. Any possible hazard incurred by maintenance of laypeople will violate the warranty. If the supply cord is damaged, it must be replaced by professional maintenance personnel.

- Please use the accessories provided by the A/C manufacturer; otherwise, the A/C may be damaged.

- Cleaning and user maintenance shall not be made by children without supervision.

SAFETY INSTRUCTIONS

IMPORTANT!

AIR CONDITIONERS MUST ALWAYS BE STORED AND TRANSPORTED UPRIGHT, OTHERWISE IRREPARABLE DAMAGE MAY BE CAUSED TO THE COMPRESSOR; IF IN DOUBT WE SUGGEST WAITING AT LEAST 24 HOURS FOLLOWING INSTALLATION BEFORE STARTING THE UN

SereneLife SLPAC12 - IMPORTANT! - 1

natural_image Simple line drawing of an open book with no text or symbols visible
  • Carefully read the instructions before installing and/or operating the unit.
    • This appliance is for indoor use only.
  • This unit must be only connected to a 220-240 V / 50 Hz earthed outlet.
  • Installation must be in accordance with regulations of the country where the unit is used.
  • If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician.
  • This air conditioner has been tested and is safe to use. However, as with any electrical appliance - use it with care.
  • Disconnect the power from the appliance before dismantling, assembling or cleaning.
  • Avoid touching any moving parts of the appliance.
  • Never insert fingers, pencils or any other objects though the guard.
  • This appliance is not intended for use by persons (including children) with reduce physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • Do not leave children unsupervised with this appliance.
  • Do not clean the unit by spraying it or immersing it in water.
  • Never connect the unit to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a qualified electrician.
  • Do not operate the unit unless it has been fully installed following the guidance provided within this manual.

  • Never operate this appliance if the cord or plug is damaged. Ensure the power cord is not stretched or exposed to sharp objects/edges.

  • A damaged supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard.
  • Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to comply could result in a voided warranty.
  • Do not use the appliance for any purpose other than its intended use.
  • Avoid restarting the air conditioner unless 3 minutes have passed since being turned off. This prevents damage to the compressor.
  • Never use the main plug as a switch to start and turn off the air conditioner. Use the provided ON/OFF button located on the control panel.
    • The appliance should not be installed in laundry or wet rooms.
  • The appliance must be installed in a room without sources of ignition (for example: open flames, an operating gas appliance or an operating electric heater).
  • The unit must be installed on a solid vertical wall by a competent person. The electricity supply must only be connected after installation is complete.
    • R290 refrigerant gas complies with European environmental directives.
    • R290 has a low GWP (Global Warming Potential) of 3.
    • The air conditioner contains about 245g of R290 refrigerant gas.
  • Do not install or store in an unventilated space with an area smaller than 12 ~m^2 per unit. The room must be such as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of fire or explosion hazard should the refrigerant come into contact with electric heaters, stoves or other sources of ignition.
  • If the appliance is installed, used or stored in an unventilated room, the room must be such as to prevent stagnation of possible leaks or refrigerant gas as there could be a danger of fire or explosion should the refrigerant come into contact with electric heaters, stoves or other sources of ignition.
    • Refrigerant gas may be odourless.
  • Do not use the product and contact the retailer for advice, if damage has occurred to the unit which may have compromised the refrigerant system.

  • Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer. Before opening and servicing the unit the authorized engineer must be in possession of a copy of the manufacturer's service manual and must follow the safety information contained within it to ensure all hazards are minimized.

  • The refrigerant system should not be perforated or punctured.

NOTE: Some pictures and information may vary from the final product. This is due to continual product improvement.

Special Warning:

  • Place the A/C on even ground and install it vertically, so as to ensure normal operation of the compressor.
  • The A/C should be at least 50cm away from surrounding objects. Keep air inlet and outlet smooth.
  • Don't use the A/C beside gasoline or any other inflammable liquid.
  • Don’t use spraying agent and other solvent or flammable substances near the A/C; otherwise, its plastic may deform and electric parts may be damaged.

Power

  • The plug should be in good condition and can't be damaged. Don't replace the plug with power plug.
  • In order to run the A/C, plug the power cord first, and then press the power key.
  • Place unit in upright position for 2 hours before turning on for first time.

Product Introduction

MAIN PARTS AND COMPONENTS

  1. Handle
  2. Air inlet (L)
  3. Control panel
  4. Wind guide vent
  5. Caster
  6. Remote controller
  7. Air inlet (R)
  8. Air outlet
  9. Air inlet grille
  10. Window sealing plate

  11. Dehumidification drainage nozzle

  12. Exhaust duct assembly

SereneLife SLPAC12 - MAIN PARTS AND COMPONENTS - 1

Control Panel and Remote Controller

8 7 TIMER MODE Cool Tan Dry Inst °C 4 SPEED HIGH Mid Low SWING POWER 6 5 3 2 1

Cooling and Heating Model

1. Power key

Press the key to turn ON/OFF the A/C.

2. Swing key

Press the key at any time after turning on the A/C to swing the wind guide bar automatically.

3. Speed key

Press the key to choose high/middle /low gear wind speed.

4. Temperature/ Time Adjusting key

Press the key at cooling mode to increase /reduce the setting temperature; press it at timing mode to adjust timing ON/OFF time; press Up and Down keys simultaneously to switch Fahrenheit and Centigrade degree temperature.

5. Mode key

Press the key to choose cooling, fan, dehumidification.

6. Timer key

Press the key at standby mode to set ON time. Press this key at ON mode to set OFF time.

7. Temperature/ Time Display Window

This window displays the adjusted temperature and time.

8. Remote controller receiving window

This window is used to receive signal of the remote controller.

°C/°F switching key: Press the key to switch °C and °F.9.

4 High Up Cool Mid Down Dry Low Heat Fan Swing °C /°F Timer Power 1 2 3 5 9 6 SereneLife

Product Operation

Placement and Installation

Placement

- Place it at even and dry place, and keep it at least 50cm. away from its surrounding object.

50cm

Installation

- Screw the exhaust duct assembly in the air outlet behind the panel (counterclockwise).

SereneLife SLPAC12 - Installation - 1

natural_image Technical line drawing of a mechanical device with coiled tubing and ventilation grilles (no text or symbols)

- Insert the air exhaust hose into the window sealing plate, adjust opening width of window so that the window can match with the sealing plate properly; length of the sealing plate is adjustable.

SereneLife SLPAC12 - Installation - 2

natural_image Line drawing of two household air purifiers connected by tubing, one with a window and the other with a door (no text or symbols)

Incorrect Installation

  • It's important to keep the exhaust duct smooth. Incorrect installation will affect work of the A/C.
    • Prevent the exhaust duct from sharp bending.
  • Ensure air can flow smoothly in the duct.

Warning:

The exhaust duct is designed especially for this model. Don't replace or lengthen it; otherwise, it will result in failure.

Notice:

Max. developed length of the exhaust duct is 1,500mm. It's better to shorten it while in use and keep it horizontal while installation.

SereneLife SLPAC12 - Notice: - 1

natural_image Technical line drawing of a mechanical device with a grid base and X-shaped component (no text or symbols)

OPERATION METHOD

Plug in the unit and in standby mode, the ambient temperature will shows on the display screen, you can choose the working mode (Cool or Heat) and the desired temperature according to the ambient temperature. Also, the ambient temperature will shows on the display under Fan Mode and the Dehumidification Mode, and temperature setting is not available in those two modes.

Cooling Mode

  • When the A/C enters cooling mode automatically or cooling mode is selected after power ON, the cooling indicator lamp lights up.
  • Press Up/Down key to adjust setting temperature (16°C\~30°C)(60°F\~86°F).
  • Press Speed key to choose High/Mid/Low speed.

Fan Mode

  • When pressing mode key or choosing Fan mode by pressing the remote controller, the wind indicator lamp lights up.
  • Press Speed key to choose High/Mid/Low speed.
    • Temperature can't be set.

Dehumidification Mode

  • When pressing mode key or choosing dehumidification mode by pressing the remote controller, the dehumidification indicator lamp lights up.
  • Remove the dehumidification water wedge, insert water manifold, place the other end of the water manifold into the water vessel or drainage passage, as shown in the right figure.
    • After entering the dehumidification mode, if room temperature≥17°C (62°F), the compressor is ON. Then control as follows: when room temperature ≤15°C (59°F), the compressor is OFF; when temperature increases to room temperature≥17°C (62°F), the compressor will start again (in order to protect the compressor, it will be restarted 3min. later).
  • In dehumidification mode, the fan is defaulted to run at low speed, and wind speed can't be adjusted.
    • Temperature can't be set.

Auto mode (for cooling model only)

  • When pressing mode key or choosing auto mode by pressing the remote controller, the auto indicator lamp lights up.
    • After choosing Auto mode, operation state is determined by environmental temperature: when environmental temperature is higher than 25^ C ( 77^ F), the operation state is the same as that of cooling mode; when environmental temperature is lower than 25^ C ( 77^ F), the operation state is the same as that of fan mode.

Timer Mode

  • In standby state, press the Timer key to set ON time. Press Up and Down keys to set ON time (1\~24H), and the timer indicator lamp lights up.
  • In ON state, pressure the timer key to set OFF time. Press Up and Down keys to set OFF time (1\~24H), and the timer indicator lamp lights up.

Clean and Maintenance

DRAINAGE METHOD

This product is equipped with automatic water vaporization system. The condenser is cooled with the circulating of condensing water, so as to improve cooling efficiency and save energy.

SereneLife SLPAC12 - DRAINAGE METHOD - 1

natural_image Line drawing of a portable air conditioner unit with a cup beside it (no text or symbols)

- If the internal vessel is full of water, the display screen will display "FL", and the compressor stops working automatically. After power off, unscrew the water cover, pull out the water plug to drain off water, and it will become normal after being restarted.

MAINTENANCE

Notice: In order to avoid electric shock, please turn off the A/C and unplug before maintenance or repair.

CLEANING

• Unplug before cleaning.
- Wipe with soft semi-dry cloth. Don't use chemical reagent, such as benzene, alcohol and gasoline etc; otherwise surface of the A/C and even the whole A/C will be damaged.
• Prevent water from spattering in the A/C.

FILTER SCREEN

• Vacuum the filter screen once every two weeks. If it is blocked by dust, efficiency of the A/C will be reduced.
• Take out the air inlet grille and pull out the filter screen at both sides according to the direction shown in the following figures. Use vacuum to remove lint from filters.
- Put the filter screen into the warm water (about 40°C or 104°F) added with neutral detergent, dry it at a shady place after cleaning.

SereneLife SLPAC12 - FILTER SCREEN - 1

natural_image Line drawing of a portable air conditioner unit with fan and cooling fins (no text or symbols)

SereneLife SLPAC12 - FILTER SCREEN - 2

natural_image Line drawing of a portable air conditioner unit with cooling fins and a handle (no text or symbols)

SereneLife SLPAC12 - FILTER SCREEN - 3

If filter is dirty, clean in 40^ C ( 104^ F) warm water or in water with neutral detergent.

SereneLife SLPAC12 - FILTER SCREEN - 4

natural_image Illustration of a hand holding a tool over a grid-patterned surface (no text or symbols)

SereneLife SLPAC12 - FILTER SCREEN - 5

natural_image Illustration of a hand spraying water onto a textured surface (no text or symbols)

SereneLife SLPAC12 - FILTER SCREEN - 6

natural_image Illustration of a hand spraying a small container onto a grid-patterned surface (no text or symbols)

If filter is not that dirty, clean the dust with a vacuum cleaner.

SEASONAL CLEANING

If the A/C will not be used for a long time:

• Pull out the water plug to drain.
- Run the A/C in fan mode for 2H till the inside is dry.
• Turn off the A/C and unplug.
- Wash the filter screen and reassemble it.
• Dismantle the exhaust duct and keep it properly.
- Cover the A/C with a plastic bag and place it at a dry place.

Common Failures and Diagnosis

Intelligent Error Detection

Error-detecting codeMulti-functional defection
E1 Error of thecoil's temperature sensor
E2 Error of indoordoor temperature sensor
E4Anti-freezing protection: temperature of the coil is too low and the whole A/C is off. When temperature exceeds 8°C or 46.4°F, the protection is released and previous working state is recovered.

FUSE PARAMETERS

• Voltage: 250VAC • Current: 3.15A

Troubleshooting

In case of any of the following trouble, please contact professional maintenance personnel in time.

TROUBLE CAUSE SOLUTION
The A/Cdoesn’t workNo displayReset circuit breaker on AC cord
The display panel displays “FL”Restart the A/C after power off and draining, then it will become normal
Time OFF function is startedThe A/C can be restarted 3 minutes after being turning off.
The A/C starts frequentlyDirect sunlightDraw the curtain
Doors and windows keep open; there are lots of people or heat source in roomClose doors and windows, remove heat source
Filter screen is very dirtyClean or replace it
Air inlet or air outlet is blockedRemove the stem
Big noise of the A/CThe A/C is placed unevenlyPlace it at even and firm ground, avoid shaking
The compressor doesn’t workIts delay protection is startedWait for 3min., turn on after temperature decreases

Notice: When there is any abnormal to the A/C, turn it off and unplug, and then contact professional maintenance personnel.

The above technical parameters are subject to change without notice.

SereneLife SLPAC12 - Troubleshooting - 1

natural_image Symbol of a trash bin crossed out by two diagonal lines, no text or numbers present

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.

Contact your local government for information regarding the collection systems available.

If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge.

SLACHT12.5EU

Portable Air Conditioner

Compact Home AC Cooling Unit with Built-in Dehumidifier & Fan Modes, Includes Window Mount Kit (12,000 BTU)

Features:

• Lightweight & Portable AC Unit
• Compact Freestanding Room Air Conditioner
• (3) Operation Modes: AC Cooling / Dehumidifier / Fan
• Hassle-Free, Quick Setup Cooling
• Simple Electric Plug-in Operation
• Temp Control Air Circulator Function
• Automatic Swing Mode: Moving Wind Vents for Air Circulation
- Convenient Wide-Area Climate Control Room AC Coverage
• Digital Touch Button Control Panel with LED Display
• Time, Temperature & Fan Speed Adjustment Settings
• Includes Universal Window Mount AC Exhaust Kit
• Removable & Washable Air Filter Screen
• Modern Style, Sleek Body Housing
• Energy Efficient: Low Power Consumption
- Low Noise Level Motor
- Rolling Wheels for Easy Portability
• Used for Home, Office, School & Business Rooms

What's in the Box:

  • AC Unit
  • Exhaust Hose
    • Window Installation Plate
    • Digital Remote Control

Technical Specs:

• Cooling Capacity (ASHRAE): 12,000 BTU
• Rated Power: 1370 Watt
• Coverage Area: Cools Rooms Up to 400'+ Square Feet
• Air Flow: 360 Cubic Meters / Hour
- Operating Modes: AC Cool / Fan / Dry (Dehumidifier)
- Dehumidifier Performance / Moisture Removal: 1.2 Liters / Hour
- Operating Noise Level: 65 dB(A)
• Fan Speed Settings: Low/Medium/High
• Temperature Unit Selectable: °F / °C (Fahrenheit / Celsius)
- Adjustable Timer Settings: Up to 24 Hours
• Construction Material: Engineered ABS Housing
- Battery Operated Remote Control, Requires (2) x 'AAA' Batteries, Included
• Power Cable Length: 4.3' ft. - (131cm)
• Power Supply: 220V
- Dimensions (L x W x H):
17.4" x 13.4" x 32.1" -inches - (44.1 x 34 x 81.53 -cm)

SereneLife SLPAC12 - Technical Specs: - 1
WARNING:

This product can expose you to a chemical or group of chemicals, which may include "Acrylonitrile" which is known in the state of California to cause cancer, birth defects, or other reproductive harm. For more info, go to

https://www.p65warnings.ca.gov/.

serenelife™

QR code image containing encoded data, no visible human-readable text

Questions or Comments

We are here to help!

Phone: 1.718.535.1800

serenelifehome.com/contact us

serenelife™

SereneLife SLPAC12 - serenelife™ - 1

SereneLife SLPAC12 - serenelife™ - 2

natural_image White and black portable air conditioner unit with ventilation slots (no visible text or symbols)

SLPAC12.5EU-SLPAC12.5UK

natural_image Simple line drawing of an open book with no text or symbols visible
natural_image Technical line drawing of a mechanical device with coiled tubing and housing (no text or symbols)
natural_image Line drawing of two household air purifiers connected by tubing, one with a window and the other with a door (no text or symbols)
natural_image Technical line drawing of a mechanical device with a grid base and X-shaped component (no text or symbols)
natural_image Line drawing of a portable air conditioner with a cup beside it (no text or symbols)
natural_image Line drawing of a portable electric heater with fan and cooling fins (no text or symbols)

SereneLife SLPAC12 - SLPAC12.5EU-SLPAC12.5UK - 1

natural_image Line drawing of an electric shock absorber with cooling fins and a hand operating it (no text or symbols)

SereneLife SLPAC12 - SLPAC12.5EU-SLPAC12.5UK - 2

natural_image Illustration of a hand holding a tool over a grid-patterned object (no text or symbols)

SereneLife SLPAC12 - SLPAC12.5EU-SLPAC12.5UK - 3

natural_image Illustration of a hand spraying water onto a textured surface (no text or symbols)

SereneLife SLPAC12 - SLPAC12.5EU-SLPAC12.5UK - 4

natural_image Illustration of a hand spraying water onto a grid-patterned surface (no text or symbols)
natural_image Symbol of a trash bin crossed with no text or numbers, representing waste sorting or disposal (no text present)

We are here to help!

serenelifehome.com/contact us

serenelife™

SereneLife SLPAC12 - serenelife™ - 1

SereneLife SLPAC12 - serenelife™ - 2

natural_image White and black industrial air conditioner unit with ventilation slots (no visible text or symbols)

SLPAC12.5EU-SLPAC12.5UK

Climatisation portable

natural_image Simple line drawing of an open book with no text or symbols visible
natural_image Technical line drawing of a mechanical device with coiled tubing and heat exchanger (no text or symbols)
natural_image Line drawing of two household air purifiers connected by tubing, one with a door frame and the other with a front panel (no text or symbols)

Installation incorrecte

natural_image Technical line drawing of a refrigerant device with a grid-patterned cover and X-shaped cross symbol (no text or labels)

Fonctionnement

natural_image Line drawing of a portable air purifier with a cup and fan, no text or symbols present
natural_image Line drawing of a portable air conditioner unit with fan and cooling fins (no text or symbols)

SereneLife SLPAC12 - Fonctionnement - 1

natural_image Line drawing of a portable air conditioner unit with cooling fins and a hand inserting a plug (no text or symbols)

SereneLife SLPAC12 - Fonctionnement - 2

natural_image Illustration of a hand holding a tool over a grid-patterned object (no text or symbols)

SereneLife SLPAC12 - Fonctionnement - 3

natural_image Illustration of a hand spraying water onto a textured surface (no text or symbols)

SereneLife SLPAC12 - Fonctionnement - 4

natural_image Illustration of a hand spraying particles onto a grid-patterned surface (no text or symbols)
natural_image Symbol of a trash bin crossed with no text or numbers, representing waste sorting or restriction (no text present)

This product can expose you to a chemical or group of chemicals, which may include "Acrylonitrile" which is known in the state of California to cause cancer, birth defects, or other reproductive harm. For more info, go to

https://www.p65warnings.ca.gov/.

serenelife™

QR code image containing encoded data, no visible human-readable text

serenelifehome.com/contact us

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : SereneLife

Model : SLPAC12

Category : Air-conditioner