Product Type Single Duct Portable Air Conditioner and Heater
Brand SereneLife
Model SLACHT12W
Dimensions (L x W x H) 17.3" x 13.2" x 28" inches
Weight 67.2 lbs
Power Supply 115V/60Hz
Power Consumption 1260W
Cooling Capacity (ASHRAE) 12000 BTU/h
Cooling Capacity (DOE) 8000 BTU/h
Coverage Area Up to 380 sq ft
Airflow 400 m³/h
Dehumidification Rate 1.2 L/h
Noise Level 54 dBA
Fan Speeds Low, High
Operating Modes Auto, Cool, Fan, Dry (Dehumidifier)
Timer Up to 24 hours
Refrigerant R32 (290g charge)
Control Type Touch panel, remote control, and Smart Life app
WiFi Compatibility 2.4GHz networks, works with Alexa and Google Assistant
Filter Removable, washable air filter
Mobility Built-in casters for easy movement
Window Kit Included Yes, adjustable window installation kit
Maintenance Clean air filter every 100 hours; drain condensate when full
Safety Features Auto shut-off on full water tank, 3-minute compressor delay, tip-over? (not specified)

Frequently Asked Questions - SLACHT12W SereneLife

How do I set up the WiFi on my SereneLife SLACHT12W?
Download the Smart Life app from your app store. Plug in the unit (do not turn on). Press and hold the FAN button for 5-10 seconds until the WiFi LED blinks rapidly. In the app, select 'Add Device' > 'Home Appliances I' > 'Air Conditioner'. Enter your 2.4GHz WiFi password and confirm. Wait for connection, then name your device.
What does error code E4 mean?
Error code E4 indicates the water tank is full. Turn off and unplug the unit, move it to a drain location, and remove the drain plug at the bottom to empty the water. After draining, replace the plug securely. The unit should resume normal operation.
Can I use this air conditioner in a room without a window?
No, the SLACHT12W is a portable air conditioner that requires an exhaust hose to vent hot air outside. A window, door, or wall opening is necessary for the included window kit to expel heat. Without venting, the unit will not cool effectively.
How often should I clean the air filter?
Clean the air filter every 100 hours of use, or more frequently in dusty environments. To clean, remove the filter, wash with lukewarm water and mild detergent, dry completely in shade, then reinstall. A clean filter ensures efficient cooling and airflow.
What is the difference between Cool and Dry modes?
In Cool mode, the compressor runs to lower the room temperature. In Dry mode, the unit operates as a dehumidifier at low fan speed; the compressor cycles on and off to remove moisture without significantly cooling. Temperature adjustment is ineffective in Dry mode.
Why does my unit not start after turning off?
The unit has a 3-minute compressor delay to prevent damage. If you turn it off and back on quickly, wait 3 minutes before it restarts. If the issue persists, check the power cord, fuse, or remote control batteries.
Can I control this AC with Amazon Alexa?
Yes, after binding the unit to the Smart Life app, you can link it to Alexa. Open the Smart Life app, go to 'Me' > 'More Services' > 'Alexa', and sign in with your Amazon account. Then use voice commands like 'Alexa, turn on [device name]' or 'Alexa, set [device name] to 72 degrees'.
What are the dimensions and weight of the SLACHT12W?
The unit measures 17.3 inches in length, 13.2 inches in width, and 28 inches in height. It weighs approximately 67.2 lbs. Ensure the floor can support the weight and that there is sufficient space around the unit for airflow.
How do I install the exhaust hose and window kit?
Attach the exhaust hose to the unit's rear outlet, then connect the other end to the window kit. The kit consists of two adjustable panels that fit into a window opening. Slide the panels to match window height, tighten the wing nut, and close the window onto the kit. Ensure a tight seal.
What should I do if the unit leaks water?
Water leakage usually occurs when the condensate tank is full or if the unit is tilted. First, drain the tank via the drain plug. Ensure the unit is on a level surface. If leaking persists, check that the drain plug is securely fastened. If the problem continues, contact customer support.

User questions about SLACHT12W SereneLife

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air conditioner in PDF format for free! Find your manual SLACHT12W - SereneLife and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SLACHT12W by SereneLife.

USER MANUAL SLACHT12W SereneLife

natural_image White Serenelife air purifier with digital display and control buttons (no text or symbols on body)

SLACHT12W

Single Duct Portable Air Conditioner and Heater

USER GUIDE

About SereneLife

SereneLife products are designed to create a more comfortable living space, indoors and out. Our team presents innovative lifestyle solutions throughout the year that promote simplicity and serenity.

We're committed to delivering the most dependable products so you can live a better, more serene life.

SereneLife SLACHT12W - About SereneLife - 1

CONTENTS

INTRODUCTION 4

FEATURES AND TECHNICAL SPECS 5

FCC STATEMENT 6

ELECTRICAL SPECIFICATIONS 6

IMPORTANT SAFETY INSTRUCTIONS 7

SAFETY INSTRUCTIONS DURING SERVICING 8

IDENTIFICATION OF PARTS 9

CONNECTING YOUR AIR CONDITIONING UNIT TO THE SMART LIFE APP 19

LINK TO AMAZON "ALEXA" 23

MAINTENANCE 25

TROUBLESHOOTING 26

USING INFORMATION 28

REGISTER PRODUCT 29

IMPORTANT:

READ ALL INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT. RETAIN THIS OWNER'S MANUAL FOR FUTURE REFERENCE.

California Prop 65 Warning

! WARNING:

This product can expose you to chemicals, which is known to the state of California to cause cancer birth defects and other reproductive harm. Do not ingest.

For more info go to: www.P65warnings.ca.gov

INTRODUCTION

Thank you for choosing this mobile air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage, or office. The appliance can be moved from room to room within your home and set up in just minutes.

It is a multi-functional room air exchanging and air-processing appliance, designed to offer you the functions of cooling, dehumidifying, and independent fan. The external static pressure at which the appliance was tested is 0 MPa.

This manual will provide you with valuable information necessary for the proper care and maintenance of your new appliance. Please take a few moments to read the instructions thoroughly. If properly maintained, your appliance will give you many years of trouble-free operation.

Features:

• Metal Control Box to Prevent Fire and Exploding
- Rotary Compressor
• Efficient & Powerful Cooling
• Universal Castors for Moving Freely
• Lightweight & Portable A/C Unit
- Compact Freestanding Room Air Conditioner & Heater
• (4) Operation Modes: Auto AC Cooling / Heat / Dehumidifier / Fan
- Smart Wifi Control
• Hassle-Free, Quick Setup Cooling and Heating
- Simple Electric Plug-in Operation
• Built-in Sensitive Touch Control Panel
• Automatic Upward Swing Delivers Cool Air Widely
- Convenient Wide-Area Climate Control Room AC Coverage
• Time, Temperature & Fan Speed Adjustment Settings
- Includes Universal Window Mount AC Exhaust Kit
- Removable & Washable Air Filter Screen
• Modern Style, Matt Body Housing
• Energy Efficient: Low Power Consumption
- Low Noise Level Motor
- Rolling Wheels for Easy Portability
- Ideal for Home, Office, School & Business Rooms

What's in the Box:

  • AC Unit
  • Exhaust Hose
    • Window Installation Plate
  • Remote Control
  • Hose Connector
  • Drain Pipe

Technical Specs:

  • Construction Material: High-Quality ABS
    • Power Supply: 115V/60Hz
    • Power Output: 1260W
    • Refrigerant Type: R32
    • Cooling capacity (ASHRAE): 12000 Btu/h
    • Cooling capacity (DOE): 8000 Btu/h
    • Coverage Area: Cools Rooms up to 380 Square Feet
    • Air Flow: 400 Cubic Meters / Hour
  • Operating Modes: Auto / Cool / Fan / Dry (Dehumidifier)
  • Moisture Removal / Dehumidifier: 1.2 Liters / Hour
  • Operating Noise Level: 54 dBA
    • Fan Speed Settings: Two Level, Low/High
    • Temperature Range: °C / °F (Celsius / Fahrenheit
  • Adjustable Timer Settings: Up to 24 Hours
  • Item Weight: 67.2 lbs.
  • Battery Operated Remote Control, Requires (2) x 'AAA' Batteries, (Included)
  • Battery Construction Material: Zinc-Manganese
  • Battery Weight: 13g
    • Milliamp Hours (mAh): 500mAh
    • Power Cable Length: 5.9 ft.
  • Product Dimension (L x W x H): 17.3" x 13.2" x 28" -inches

FCC Statement

This device cornplies with part 15 of the FCC Rules. Operation is subject to following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept interference received, including interference that may cause operation.

NOTE:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is advised to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced technician for help.

Caution: Any changes or modifications expressly approved by the party for compliance could void the user's authority to operate the equipment.

FCC RF Radiation Exposure Statement Caution:

To maintain compliance with the FCC's RF exposure guidelines, place the product at least 20cm away from nearby persons.

ELECTRICAL SPECIFICATIONS

  1. All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.
  2. Check available power supply and resolve any wiring problems before installation and operation of this unit.
  3. For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall outlet. If you are not sure whether the wall outlets in your home are properly grounded, please consult an electrician. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.

IMPORTANT SAFETY INSTRUCTIONS

WARNING

To reduce the risk of fire, electrical shock, or injury when using your air conditioner, follow these basic precautions:

  1. Plug into a grounded 3-prong outlet.

  2. Do not remove the ground prong.

  3. Do not use an adapter.

  4. Do not use an extension cord.

  5. Unplug the air conditioner before servicing.

  6. Use two or more people to move and install the air conditioner.

  7. This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.

  8. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

  9. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.

  10. The appliance shall be installed in accordance with national wiring regulations.

  11. This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.

Young children should be supervised to ensure that they do not play with the appliance.

  1. Do not use means to accelerate the defrosting process or to clean, other than those means recommended by the manufacturer. The appliance shall be stored in a room without continuously operating ignition sources, for example, open flames, an operating gas appliance, or an operating electric heater. Be aware that refrigerants may not contain an odor.

Do not pierce or burn.

  1. When the machine malfunctions, do not repair it yourself. Please contact a professional organization or a professionally trained maintenance personnel or a service organization recommended by the supplier for repair!

(The maximum refrigerant charge amount: R32/290g (10.23oz)

  1. Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.

  2. The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance, or an operating electric heater).

  3. Do not pierce or burn.

  4. Be aware that refrigerants may not contain an odor.

SereneLife SLACHT12W - WARNING - 1
CAUTION RISK OF FIRE

SereneLife SLACHT12W - WARNING - 2
A2L

SAFETY INSTRUCTIONS DURING SERVICING

  1. Ensure that only qualified personnel handle maintenance and repair tasks affecting safety.
  2. Conduct safety checks before servicing systems containing flammable refrigerants to minimize ignition risks.
  3. Perform work under controlled procedures to minimize flammable gas or vapor presence.
  4. Instruct maintenance staff on the nature of work, avoiding work in confined spaces.
  5. Use appropriate refrigerant detectors to check for toxic or flammable atmospheres before and during work.
  6. Have fire extinguishing equipment available for hot work on refrigerating equipment.
  7. Avoid sources of ignition during work on refrigerating systems and display "No Smoking" signs.
  8. Work in well-ventilated areas and continue ventilation during servicing to disperse released refrigerants.
  9. Conduct initial safety checks on electrical components and report faults to the equipment owner.
  10. Disconnect electrical supplies before working on sealed components and use leak detection if power supply is necessary.
  11. Ensure electrical components are not altered during repair and use replacement parts according to manufacturer specifications.
  12. Avoid applying permanent loads to circuits exceeding equipment specifications.
  13. Only work on intrinsically safe components in flammable atmospheres and use test apparatus with correct ratings.
  14. Replace components only with manufacturer-specified parts to prevent ignition risks.
  15. Check cabling for wear, corrosion, and other environmental effects.
  16. Never use potential ignition sources to detect refrigerant leaks.

IDENTIFICATION OF PARTS
Control Panel Cold Air Outlet Signal Receptor Transport Handle Remote Controller Evaporator Air Intake Air Outlet Hose Primary Drain Port

CONTROL PANEL

MODE 68 °F °C 58 68 58 < | | <| | ><|>

Power Button Speed Button >Timer/Temperature up Button
Timer Button MODE Mode Button < Timer/Temperature down Button
Swing Button Sleep Button Low/Middle/High Fan Speed
Full Water Alarm Wifi Cool/Dehmidify/Fan/Heat/Auto

Control Panel Operation

Auto, Cool, Dehumidify, Fan, Mode Operation.

1. Turn on the unit:

a. Plug in the unit; it beeps once.
b. Press the "☐" button; the unit is turned on.

The LED displays the room temperature and operate in Automatic mode.

2. Select Operating Mode:

Press the "MODE" button to select the desired mode.

SereneLife SLACHT12W - Select Operating Mode: - 1

flowchart
graph LR
    A["Sun"] --> B["Moore"]
    B --> C["Beige"]
    C --> D["Solar"]
    D --> E["Moon"]

3. Adjust Temperature:

The temperature can be set within a range of 59-88°F.

Press the “>” and “<” button to increase or decrease the temperature.

The unit LED shows the target temperature for 5 seconds and then displays the room temperature.

Press ">" and "<" button at the same time to turn on " 🔊" mode.

Press and hold “>” and “<” button after three seconds and then turn off “💡” mode.

4. Adjust Fan Speed:

Press the " ✧" button to select your desired fan speed as indicated below:

SereneLife SLACHT12W - Adjust Fan Speed: - 1

flowchart
graph LR
    A["Start"] --> B{Decision}
    B --> C["Node"]
    C --> D["Node"]
    D --> E["End"]

5. Power:

Press the "☐" button again, and the unit will emit a "beep," indicating that it has stopped working.

  1. Swing: Press this "◀" to set swing mode.

  2. TIMER BUTTON: Used to set a delay start or shut down time.

NOTICE: Understanding Each Operation Mode

SereneLife SLACHT12W - NOTICE: Understanding Each Operation Mode - 1

Mode

  1. Once the MODE operation is selected, the indoor temperature sensor operates automatically to choose the desired mode with ✝ or ≈.

  2. If the room temperature is ≥ 75^ F, the unit will automatically select mode.

  3. If the room temperature is ≤ 75^ , the unit will automatically select mode.

SereneLife SLACHT12W - Mode - 1

Mode

  1. When the room temperature is higher than the set temperature, the compressor starts.

  2. When the room temperature is lower than the set temperature, the compressor stops and operates at the original set speed.

SereneLife SLACHT12W - Mode - 1

Mode

  1. The up centrifugal fan runs at a low speed, and the speed cannot be adjusted.

  2. The compressor and the down centrifugal fan stop after running for 8 minutes, then restart after 6 minutes.

  3. The unit operates in constant temperature dehumidifying mode, and the temperature adjustment is not effective.

SereneLife SLACHT12W - Mode - 1

Mode

  1. The up centrifugal fan runs at the set speed, and the compressor does not operate.

  2. Temperature adjustment is not effective.

SereneLife SLACHT12W - Mode - 1

Mode

  1. When the room temperature is higher than the set temperature, the unit will stop the heating function.

  2. When the room temperature is lower than the set temperature, the unit will start the heating function.

SereneLife SLACHT12W - Mode - 1

Sleep Mode: Press the sleep button to activate sleep mode.

SereneLife SLACHT12W - Mode - 2

Operation

  1. Press the "Timer" button to set the Automatic Off time while the unit is running.
  2. Press the "Timer" button to set the Automatic On time while the unit is ready.
  3. The time can be adjusted within a range of 1 hour to 24 hours.

Press the temperature up (+) or temperature down (-) button to increase or decrease the time by one hour with each press.

SereneLife SLACHT12W - Operation - 1

Operation

  1. The operation is effective when the unit is in mode.
  2. Press the ⚙ button in ✝ mode, then the unit will operate under sleep mode, and the up centrifugal fan will automatically switch to low speed.
    The set temperature will increase by 2^ F ( 1^ C) after one hour and by 4^ F ( 2^ C) after two hours. After six hours, the unit will stop running.

SereneLife SLACHT12W - Operation - 1

Operation

When the swing button is activated, the swing blade will automatically move up and down. If you want to stop, press the button again.

Notice:

The main control board has a memory function. When the unit is ready to run but in stop status, the main control board can memorize the initialization of the working mode. When you turn on the unit, it will work with the same settings as the last time, with no need to reset the working mode again. (This condition is not available when the unit is under "MODE" mode).

REMOTE CONTROLLER

The Remote Controller transmits signals to the system.

  1. ON/OFF Button: The appliance will start when energized or stop when in operation by pressing this button.

  2. MODE Button: Press this button to select the operation mode.

  3. Speed Button: Used to select fan speed in sequence mode.

4,5. ▲ and ▼ Setting Buttons: Used to adjust the room temperature and set the timer.

system. 1 ON/OFF MODE △ ▼ SPEED SLEEP SWING TIMER 2 3 4 5 6 7

  1. Sleep Button: Used to set or cancel Sleep mode operation.

  2. Timer Button: Used to set or cancel OFF and automatic ON time.

  3. Swing Button: Used to activate or deactivate automatic Swing mode.

How to Install Batteries

  1. Open the back cover and remove the isolating film from the batteries.
  2. Insert the batteries into the slot, ensuring the anode and cathode are in the correct directions.
  3. Replace the back cover and slide to close, ensuring the direction is correct.

SereneLife SLACHT12W - How to Install Batteries - 1

natural_image Technical line drawing of a remote control device with labeled parts (1 and 2), no text or symbols present.

Slide the cover to open, ensuring the direction is correct.

Notice

  1. The anode and cathode of the batteries must correspond to the signs of "+" and "-" on the remote control.
  2. Avoid using new batteries with run-down cells.
  3. If not in use for an extended period, remove the batteries.
  4. Dispose of used batteries safely to prevent environmental pollution.

How to Use

To operate the air conditioner, aim the remote controller at the signal receptor.

The remote controller can operate the air conditioner from a distance of up to 5m (16.4 feet) when pointing it at the signal receptor of the air conditioner.

Signal Receptor

PROTECTION

Operating Conditions:

The protective device may trip and stop the appliance in the following cases:

Cooling:

  • Indoor air temperature is over 109^ .
    • Room temperature is below 59^ F.

Dehumidifying:

• Room temperature is below 59^ F.

If the air conditioner runs in COOLING or DRY mode with a door or window opened for a long time when the relative humidity is above 80%, dew may drip down from the outlet.

Features of the Protector

  1. The protective device will work in the following cases.

Restarting the unit immediately after operation stops or changing mode during operation, you need to wait for 3 minutes.

  1. If the plug is taken out, when you restart the appliance, it will return to the original mode. TIMER ON and TIMER OFF must be set again.

Drain Water

Special reminder: There is condensing water recycling hidden within this unit. The condensing water is partly kept recycling between the condenser and the water plate. When the water level rises to the upper level, the float switch and water full indicator (E4) light on to remind draining water. Please cut off the power supply, move the appliance to a suitable place, remove the drain plug, drain water completely. After the drain, reinstall the plug, or the appliance may leak and make your room wet.

If the appliance is placed in a position admitting drain water, you can also connect the drain hose to the drain port for water drainage.

INSTALLATION

Installation Accessories:

SereneLife SLACHT12W - Installation Accessories: - 1

natural_image Simple line drawing of a cylindrical object with evenly spaced ridges (no text or symbols)

A

SereneLife SLACHT12W - Installation Accessories: - 2
B

SereneLife SLACHT12W - Installation Accessories: - 3
C

SereneLife SLACHT12W - Installation Accessories: - 4
DFEG

SereneLife SLACHT12W - Installation Accessories: - 5

natural_image Simple line drawing of a rectangular object with a curved cutout on top (no text or symbols)

SereneLife SLACHT12W - Installation Accessories: - 6

SereneLife SLACHT12W - Installation Accessories: - 7

A. Air Exhaust Duct
B. Connector of Air Exhaust Duct
C. Window Exhaust
D. Remote Controller
E. Baffle Plate
F. Drain Hose
G. Wing Nut Set

Select the Best Location

  • Beside a window, a door, or a French window.
  • Keep a required distance from the return air outlet to the wall or other obstacles, at least 60 cm (23.6"). Fix one end of the air hose (A) on the air outlet underside the appliance.
  • Extend the air hose to ensure that the other end of the air hose has clearance between the window, door, or French window, or wall hole.
  • Ensure the air outlet or intake is not blocked by a protective grid or any obstacle.

Install Exhaust Hose and Adapter

How to connect the connectors to the Air exhaust duct.

  1. Extend the air exhaust duct (A) by drawing out the two ends of the duct.
  2. Screw the air exhaust duct (A) into the connector of air exhaust duct (B) anticlockwise.

Air intake Air outlet Air intake

SereneLife SLACHT12W - How to connect the connectors to the Air exhaust duct. - 2

natural_image Technical diagram showing two mechanical or fluidic components with directional arrows indicating flow or movement (no text or symbols present)
  1. Screw the connector of the window (C) into the air exhaust duct (A) anticlockwise.

SereneLife SLACHT12W - How to connect the connectors to the Air exhaust duct. - 3

natural_image Technical line drawing of a cylindrical mechanical component with internal grooves and a central hub (no text or symbols)
  1. Connect the connector of the air exhaust duct (B) to the unit from top to bottom until it clicks into position. If you need to remove the hose, please press the locking system and slide the connector from bottom to up.

SereneLife SLACHT12W - How to connect the connectors to the Air exhaust duct. - 4

natural_image Technical line drawing of a mechanical device with a cylindrical component and internal components, showing no text or symbols.

Locking system

Install Window Kit

B A

  1. Separate both boards A board, and B board

SereneLife SLACHT12W - Install Window Kit - 2

natural_image Pure technical diagram of a mechanical component with labeled point B and directional arrows (no text or symbols beyond label)
  1. Screw the wing nut through the B board. Leave 2/3 of free space.

A B A B g.1 A

  1. Insert A board into B board according to arrowhead direction.

  2. Once assembled, adjust A board up or down according to the height of the window. Screw it until it is tight.

SereneLife SLACHT12W - Install Window Kit - 4

  1. Install the exhaust air duct and its accessories into the window kit following the arrowhead direction.

6. Ass fini

  1. Assembly finished.

SereneLife SLACHT12W - Install Window Kit - 6

natural_image Simple line drawing of a vertical pipe with a square end, no text or symbols present
natural_image Pure architectural line drawing of a window with vertical panes and horizontal dividers (no text or symbols)
natural_image Pure technical line drawing of a pipe connection with no text or symbols
  1. Open the window where you need to install the exhaust air duct, window kit, and their accessories.

  2. Install the exhaust air duct, window kit, and their accessories onto the window. Close the window according to the arrowhead direction in Fig7, pressing the window kit tightly.

SereneLife SLACHT12W - Install Window Kit - 7

natural_image Pure architectural line drawing of a window with a pipe and door, no text or symbols present
  1. Install the exhaust air duct, window kit, and their accessories onto the window following the illustration in Fig8.

SereneLife SLACHT12W - Install Window Kit - 8

natural_image Technical line drawing of a mechanical device with a side-view inset showing internal structure (no text or symbols)

Fig. 9 Fig. 10

SereneLife SLACHT12W - Install Window Kit - 9

natural_image Line drawing of a mechanical device with a cylindrical component inserted into a housing (no text or symbols)
  1. Connect the other end of the exhaust air duct and its accessories to the portable air conditioner.

  2. The assembly of the exhaust air duct and its accessories is complete, as illustrated in Fig10.

SereneLife SLACHT12W - Install Window Kit - 10

natural_image Line drawing of a door handle opening a window, labeled Fig. 11 (no text or symbols on the diagram itself)
  1. The entire unit is now well-assembled, as shown in Fig11.

Connecting Your Air Conditioning Unit to The Smart Life App

Step 1: Download the Smart Life App

Scan the QR code (on the right) or search for "Smart Life" on the App Store/Play Store.

Step 2: Registering an Account

Once the app has downloaded, open it and click login. If you do not already have an account, click register. You will be met with the page shown on the left. You can also register using your phone number.

QR code with a blue house icon in the center, likely linking to a digital service or app.

When you have registered, you will receive a verification code either through email or text, depending on how you registered (see below).

Enter verification code

10:56 ← Email Phone Register by email United Kingdom +44 Email Details verification code I agree with Service Agreement and Privacy Policy

Step 3: Creating Your "Smart Family"

After registering and verifying using the code, you will be ready to set up your new smart device. Simply click "Create Family" (shown on the right).

You will be taken to the page shown on the right. This is where you can set up which room the air conditioning unit is in.

Turn on your smart life Create family

The family name is a group name under which all your smart devices will be grouped; this does not have to be correct; it is simply a group under which all your smart devices will be located.

The location is NOT mandatory; if you do not wish to enter this information, you do not have to.

Welcome home Set your home location, get more information > All Devices No devices Add Device

< Add family Done Family Name Enter the name Family Location Set location > Smart devices in rooms: Living Room Bedroom Second Bedroom Dining Room Kitchen Study Room Add Room You can change the room settings anytime

Once all this information is entered, click "Done" in the top right, and you will be taken to the main Home Page. From here, you can control all of your smart devices.

Step 4: Binding the unit to the App

From the home page, click "Add Device," and you will be taken to this page on the left.

Select "Home Appliances 1" from the list and then select "Air Conditioner" (Blue box around the correct item).

Add Manually Search Device Electrical Smart Lighting Air Conditioner Refrigerator Washing Machine Home Ap- pliances I Water Heater Home Ap- pliances II Kitchen Security & Sensor Sport & Health Others

To put the unit into Wi-Fi mode, plug the unit into the wall, but do not push the power button.

Simply press and hold the "FAN" button until the unit beeps, and the Wi-Fi LED flashes. This will usually take between 5-10 seconds.

1 device(s) added successfully SERENELIFE PORTAB... Added successfully Done

Below is the control panel of the SLACHT12W and SLACHT14W models with the "FAN" button highlighted.

MODE 68 °F °C

Once the LED is flashing rapidly, proceed to click "Confirm indicator rapidly blink" on your screen.

You will then be brought to this page (on the right), where it should automatically input your Wi-Fi network name connected to your phone. Enter the password, then click "Confirm." Please note the unit will be searching for the App to connect to; input these details as soon as possible after confirming the LED flashing.

Add Device Enter Wi-Fi Password Only support 2.4GHz Wi-Fi network DrayTek-LAN-A Change Network ...... Confirm

Once entered and pressed "Confirm," the App will be trying to connect to the unit.

Wait while the unit connects (shown on the right). If the unit fails to connect, please retry from Step 4 before contacting us about a problem.

15:31 Add Device 1 device(s) being added SERENELIFE PORTA... Being added

Step 5: Setting Up New Device on the App

Once the unit has connected, you will be given the option to change the name of the air conditioner. The name you enter will be what you refer to it as using Alexa or Google (the name can be changed at any time).

Add Device 1 device(s) added successfully SERENELIFE PORTAB... Added successfully Done

Add Device 1 deviceial added successfully PORTABLE AIR CON... Added successfully Done

SERENELIFE PORTABLE AC Current Temp Off 86°F Device will off after 07:42 MODE ON SWING OTHER temp ON

Please note if you have more than 1 air conditioning unit, you will need to name them differently, so you can control each unit separately using Alexa or Google.

Now that you have successfully bound the system to the WiFi App, you can test this out by turning the unit on and setting the temperature.

Once this is working, you can now bind the Smart Life app to Alexa or Google.

Preparation before use:

  1. Ensure a stable Wi-Fi network that can access the Amazon server. (For mainland China users)
  2. An Echo device, including Echo, Echo Tap, or Echo Dot.
  3. An Amazon account. (If you don't have one, sign up first).
  4. Make sure there's at least one device under your "Smartlife" account, and the device's name can be easily recognized by Echo.

Connection method 1:

  1. Open "Alexa" and search for the "Smartlife" application. Click "ENABLE TO USE".
  2. Click "Agree and link".
  3. Click "CLOSE" to complete the skill binding.

Connection method 2:

You can connect your mobile air conditioner to Amazon Alexa using the "Smartlife" app:

  1. In the "Me" section in the lower right corner of "Smartlife", select "More Services" and then "Alexa".
  2. Sign in with Amazon.
  3. Confirm the link to complete the skill binding.
  4. Click "Back".

Tap to Set Nickname Third-Party Voice Services Alexa Home Management > Message Center • > FAQ & Feedback >

amazon alexa Binding your app account to your Amazon account allows you to control Alexa-enabled devices through Amazon Echo speakers (ex. "Alexa, turn on light.") Sign In With Amazon View more ways to link

Control devices by voice commands:

Now you can control your smart devices through Alexa.

You can use the following commands to control your devices:

  • Querying the ambient temperature: "Alexa, what is the temperature of ?"
  • Power switch: "Alexa, turn on " / "Alexa, turn off "
  • Adjust the temperature: "Alexa, set to N"

NOTE: Every time you change the device's name on the "Smartlife" app, Alexa must rediscover it before it can be controlled.

Maintenance

Appliance Maintenance

  1. Cut off the power supply: Turn off the appliance before disconnecting it from the power supply.
  2. Wipe with a soft, dry cloth: Use lukewarm water (below 104^ F/ 40^ C) to clean if the appliance is very dirty.
  3. Never use volatile substances such as gasoline or polishing powder to clean the appliance.
  4. Never sprinkle water onto the main unit.

Air Filter Maintenance

It is necessary to clean the air filter after using it for about 100 hours.

Clean it as follows:

  1. Stop the appliance and remove the air filter.

SereneLife SLACHT12W - Clean it as follows: - 1

natural_image Technical line drawing of an air conditioning unit with cooling fans and ventilation slots (no text or labels)
  1. Clean and reinstall the air filter. If the dirt is conspicuous, wash it with a solution of detergent in lukewarm water. After cleaning, dry it in a shaded and cool place, then reinstall it.
  2. Clean the air filter every two weeks if the air conditioner operates in an extremely dusty environment.

Maintenance After Using

  1. If the appliance will not be used for a long time, be sure to pull out the primary and the secondary rubber plug of the drain port to drain the water.
  2. Keep the appliance running with the fan only for a half day during a sunny day to dry the appliance inside and prevent it from going moldy.
  3. Stop the appliance and pull out the power supply plug, then take out the batteries of the remote controller and store the appliance properly.
  4. Clean the air filter and reinstall it.
  5. Remove the air hoses and store them properly, covering the hole tightly.

Troubleshooting

Does not run:

  • If the protector trip or fuse is blown.
  • Wait for 3 minutes and start again; the protector device may be preventing the unit from working.
  • Check if batteries in the remote controller are exhausted.
  • Ensure the plug is properly plugged in.

Runs for a short while only:

  • Adjust the set temperature if it is close to room temperature.
  • Remove any obstacles blocking the air outlet.

Runs but not cooling:

  • Check if the door or window is open.
  • Ensure there are no other heat-producing appliances in operation.
  • Clean the air filter.
  • Ensure the air outlet or intake is not blocked.
  • Adjust the set temperature if it is too high.

Water leak during moving:

  • Drain the condensate before moving.
  • Place the unit on flat ground to avoid water leakage.
  • Does not run and water full indicator:

Does not run and water full indicator "E4":

  • Pull out the rubber plug to drain water.
  • If the issue persists, contact a qualified service technician.

Machine Failures, Causes, and Solutions:

Failures CausesSolutions
Machine fails to start up.Power supply failure:1. Not plugged;2. Plug or socket damaged;3. Fuse broken.Plug in;Replace the power cord or socket;Replace the fuse by a service provider(Specification: 6.3A/250VAC).
Machine automatically stops.TIMER shut down or set temperature reached.Restart or wait for auto-switch.
No cold air under COOLING mode.Room temperature lower than set temperature;Machine enters into anti-frost protection.Normal phenomenon; the machine will auto-switch while the room temperature is higher than the set temperature;The machine will auto-switch after anti-frost protection is over.
LED displays failure code “E2”Room temperature sensor fails or damaged.Replace the room temperature sensor.
LED displays failure code “E3”The evaporator coil pipe sensor fails or damaged.Replace the evaporator coil pipe sensor.
LED displays failure code “E4”Drain out the water.Water-fu

Using Information

Cautions:

  • Keep the unit at least 3.3 feet away from TVs or radios to avoid electromagnetic interference.
  • Avoid exposing the unit to direct sunlight to prevent surface color fading.
  • Do not tilt the unit for more than 35^ or upside-down during transportation.
  • Place the unit on a flat surface with less than a 5^ inclination.
  • The unit operates more efficiently in certain room locations (see Technical Specifications).
  • Empty the condensed drainage pan before storing the unit at the end of the season.
  • Do not use chemical solvents to clean the unit surface to avoid scratching or damaging the surface.
  • Cut off the power before disassembling or installing the air-inlet fence.
  • Empty the water from the water tank before moving the machine.
  • Remove the battery before scrapping and dispose of it safely.

SereneLife SLACHT12W - Cautions: - 1

Register Product

Thank you for choosing SereneLife. By registering your product, you ensure that you receive the full benefits of our exclusive warranty and personalized customer support.

Complete the form to access expert support and to keep your SereneLife purchase in perfect condition.

QR code image containing encoded data, no visible human-readable text

Serenelifehome.com/ register

serenelife™

QR code image containing encoded data, no visible human-readable text

Questions or Comments?

We are here to help!

Phone: 1.718.535.1800

Serenelifehome.com/ContactUs

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : SereneLife

Model : SLACHT12W

Category : Air conditioner