Product Type Automatic Wrist Blood Pressure Monitor
Brand HoMedics
Model BPW-060
Measurement Method Oscillometric
Pressure Range 40–280 mmHg
Pulse Range 40–199 beats/minute
Accuracy Pressure: ±3 mmHg; Pulse: ±5% of reading
Power Source 2 AAA alkaline batteries (1.5V each)
Memory Capacity 60 measurements per user (2 users, 120 total)
Auto-shut-off 1 minute after last button operation
Wrist Circumference 5.3–7.7 inches (13.5–19.5 cm)
Dimensions 3.3 x 2.9 x 1.4 inches (84 x 74 x 35 mm)
Weight 0.30 lbs (136 g) without batteries
Operation Environment Temperature: 50–104°F (10–40°C); Humidity: 15–90% RH
Storage Environment Temperature: -4–158°F (-20–70°C); Humidity: <90% RH
Display LCD with systolic, diastolic, pulse, date/time, Risk Category Index
Key Features Smart Measure technology, Risk Category Index, dual user memory, date/time setting
Cleaning Wipe with damp soft cloth; do not use chemicals, alcohol, or thinner
Warranty 5-year limited warranty
Accessories Included 2 AAA batteries, carrying case

Frequently Asked Questions - BPW-060 HOMEDICS

How should I apply the wrist cuff?
Remove all jewelry and roll up sleeves. Place the cuff on your left wrist with your palm facing up. The edge of the cuff should be about 1/4 to 1/2 inch (1 cm) from your palm. Fasten the hook and loop strap snugly so there is no extra space between the cuff and your wrist. If you have poor circulation in your left arm, use your right wrist.
What is the correct posture for measurement?
Sit upright in a chair with your feet flat on the floor. Place your elbow on a table so that the cuff is at the same level as your heart. Relax your arm and turn your palm upward. Avoid leaning back or moving during measurement.
How do I set the date and time?
Press the Set button (⊕). The month will blink. Press the + button to change, then Set to confirm. Repeat for day, hour, and minute. Press Set after each entry.
How many measurements can the monitor store?
The monitor stores up to 60 measurements for each of two users, for a total of 120 measurements.
What does the Risk Category Index indicate?
The Risk Category Index compares your reading to NIH blood pressure standards and displays a cue (e.g., Stage 1, Stage 2) if your reading falls into a potentially elevated risk category. No cue appears for normal readings.
How do I clear stored memory?
First select the user (User 1 or User 2) using the ⊕ button. Then press and hold the + and Set (⊕) buttons simultaneously while in memory recall mode. The data for that user will be erased.
What does error E1 on the display mean?
Error E1 indicates an air circuit abnormality. Simply measure again. If the error persists, contact HoMedics Consumer Relations.
Can I use the monitor on my right wrist?
Yes, if you have poor circulation in your left arm, you may use your right wrist. Attach the cuff the same way, with your palm facing up.
What type of batteries does the monitor require?
It requires two 1.5V AAA alkaline batteries. Do not use rechargeable batteries. Replace all batteries at the same time.
What is the warranty period?
The HoMedics BPW-060 comes with a 5-year limited warranty covering defects in material and workmanship under normal use.

User questions about BPW-060 HOMEDICS

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Blood pressure monitor in PDF format for free! Find your manual BPW-060 - HOMEDICS and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. BPW-060 by HOMEDICS.

USER MANUAL BPW-060 HOMEDICS

Commerce Township, MI

48390

Automatic Wrist Blood Pressure Monitor

HOMEDICS 18 120 80 72 12:35"~ 12/20 SYS. mmHg DIA. mmHg Pulse /min. M START STOP

El manual

en español

empieza en la

página 36

BPW-060

5 year limited warranty

TABLE OF CONTENTS

INTRODUCTORY INFORMATION:

Important Product Notices and Safety Instructions ....3

About Blood Pressure ......6

What is Blood Pressure?

Why Measure Your Blood Pressure?

Blood Pressure Standard ....7

How This Blood Pressure

Monitor Works 8

USAGE INFORMATION:

Name/Function of Each Part ....10

Display Explanations ......11

Installing Batteries ....13

Date & Time Set Procedure......15

Applying the Cuff ....15

Correct Measurement Posture .....17

Measurement Procedure ....18

Risk Category Index 22

Recalling Values from Memory......23

Clearing Values from Memory ......25

Important Notes Regarding Your Blood Pressure Measurement .....26

Care, Maintenance & Cleaning .....28

Potential for Electromagnetic Interference ....31

Troubleshooting ....32

Specifications ....33

5 Year Limited Warranty ....34

IMPORTANT PRODUCT NOTICES AND SAFETY INSTRUCTIONS

When using your blood pressure monitor, basic precautions should always be followed. Please read and follow all instructions and warnings before using this product. Save these instructions for future reference.

  • Please note that this is a home healthcare product only and it is not intended to serve as a substitute for the advice of a physician or medical professional.
  • Do not use this device for diagnosis or treatment of any health problem or disease. Measurement results are for reference only. Consult a healthcare professional for interpretation of pressure measurements. Contact your physician if you have or suspect any medical problem. Do not change your medications without the advice of your physician or healthcare professional.

  • This device may have difficulty determining the proper blood pressure for individuals with irregular heartbeat, diabetes, poor circulation of blood, kidney problems or for users who have suffered from a stroke.

  • Consult your physician before measuring blood pressure at the wrist if you have any of the following conditions: Severe hypertension, irregular heartbeat, severe diabetes, severe arteriosclerosis, severe kidney disease or vascular disease that may compromise circulation.
  • The pulse display is not suitable for checking the frequency of heart pacemakers.
  • Electromagnetic interference: The device contains sensitive electronic components. Avoid strong electrical or electromagnetic fields in the direct vicinity of the device (e.g. mobile telephones, microwave ovens). These may lead to temporary impairment of measurement accuracy.
  • Use blood pressure monitor only for its intended use.

  • Do not wrap the cuff around body parts other than your wrist.
    • Not for use by or on persons under the age of 18

  • Use only 1.5V AAA alkaline batteries for power supply.

Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultatory method, within the limits prescribed by the American National Standard, Manual, electronic, or automated sphygmomanometers.

ABOUT BLOOD PRESSURE

What is Blood Pressure?

Blood pressure is the pressure exerted on the artery walls while blood flows through the arteries. The pressure measured when the heart contracts and sends blood out of the heart is systolic (highest) blood pressure. The pressure measured when the heart dilates with blood flowing back into the heart is called diastolic (lowest) blood pressure.

Why Measure Your Blood Pressure?

Among today's various health problems, those associated with high blood pressure are very common. High blood pressure dangerously correlates with cardiovascular diseases. Therefore, blood pressure monitoring is important for identifying those at risk.

BLOOD PRESSURE STANDARD

The table below contains defined levels for hypertension that are publicly available from the National Heart Lung and Blood Institute at the U.S. National Institutes of Health (NIH) (http://www.nhlbi.nih.gov/health/dci/Diseases/Hbp/HBP_Whatls.html). Users can compare their own blood pressure readings against these defined levels to determine if they may be potentially at increased risk.

This table is applicable to most adults aged 18 and older. Blood pressure tends to go up and down, even in people who normally don't have high readings. If your numbers stay above the “normal” range most of the time, you may be at increased risk and should consult your physician.

CategorySystolic (mmHg)Diastolic (mHg)
Normal Less than 120 and Less than 80
Prehypertension 120-139 or 80-89
High Blood Pressure
Stage 1 140-159or 90-99
Stage 2 160 or higher or100 or higher

Although one can easily find where their own blood pressure readings fall on this table, this monitor comes equipped with a Risk Category Index that automatically compares each reading to the defined levels and provides a helpful cue if your reading falls into one of the stages that could potentially indicate increased risk. See page 22 for more information on this feature.

Please note that cues provided by this monitor are only intended to assist you in using this table. The table and cues are only provided for convenience to help you understand your non-invasive blood pressure reading as it relates to the NIH information. They are not a substitute for a medical examination by your physician. It is important for you to consult with your physician regularly. Your physician will tell you your normal blood pressure range as well as the point at which you may actually be considered to be at risk

HOW THIS BLOOD PRESSURE MONITOR WORKS

This monitor uses Smart Measure™ technology to detect your systolic pressure, diastolic pressure and pulse. Smart Measure™ technology enables the monitor to automatically inflate and deflate at the appropriate level for each individual. With one touch of a button, the cuff will automatically inflate to block the blood flow through your artery. Next, the deflation process starts. When measurement is complete, the monitor will display your systolic pressure, diastolic pressure, and pulse readings. Please note that any muscle movement during inflation or deflation will cause measurement error.

The monitor automatically finds where your measurement results fall on the NIH's National Heart Lung and Blood Institute's table and provides a cue if your reading falls into one of the stages that could potentially indicate increased risk. Please refer to page 22 for more information on this feature.

NAME/FUNCTION OF EACH PART
LCD Display HOMEDICS 120 80 12/20 12/35" Pulse/min. SYS Systeine DIA mmHg Date/Time/User Set Buttons START STOP M Battery Cover Wrist Cuff Memory Recall Button START/STOP Button

Accessories Included:
HOMEDICS BPW-060 - HOW THIS BLOOD PRESSURE MONITOR WORKS - 2
2 "AAA" size, 1.5V alkaline batteries included in the carrying case with the unit.

DISPLAY EXPLANATIONS
ERROR 120 120 80 80 AVG. 3 12:38PM 6/15 76 Systolic Pressure Diastolic Pressure Heart Rate Date/Time Indicator

Display Symbols:

1User 1: Appears when the monitor is operated by User 1.
2User 2: Appears when the monitor is operated by User 2.
Weak Battery Symbol: Appears when batteries should be replaced.
Pulse Symbol: Shows the heart rate per minute.
AVG. 3Memory Average: Displays average of last 3 readings
Risk Category Index: See page 22 for more information.

If ERROR and any of the following letters and numbers appear in the area that systolic pressure should be displayed, an error has occurred with your reading. See Troubleshooting section of this manual for more information.

EEMeasurement Error: Measure again. Wrap the cuff correctly and keep wrist steady during measurement.
E1Air Circuit Abnormality: Measure again.
E2Pressure Exceeding 300 mmHg: Switch the unit off to clear, then measure again.
E3Error Determining Measurement Data: Measure again.

INSTALLING BATTERIES

  1. The battery cover is located along the bottom side of the monitor. Remove battery cover by pressing down and pulling away from the monitor.
  2. Install batteries according to the polarity indications inside the compartment (as shown in figure 2). Battery Type: 2 Alkaline LR03 (AAA) size
  3. Place in the other battery, according to the polarity indications inside the compartment (as shown in figure 3).
  4. Replace the cover by inserting it back into place.

HOMEDICS BPW-060 - INSTALLING BATTERIES - 1

natural_image Illustration of a mechanical device with a curved top component and a small arrow pointing to it (no text or symbols)

HOMEDICS BPW-060 - INSTALLING BATTERIES - 2

natural_image Diagram of a mechanical device with a cylindrical component and a plus sign, no readable text or symbols present.

3.

HOMEDICS BPW-060 - INSTALLING BATTERIES - 4

natural_image Illustration of a car seat with a handle and arrow indicating direction (no text or symbols)

Replace the batteries if:

  1. The weak battery symbol appears on the display.
  2. Nothing appears on the display when the power is switched on.

As the supplied batteries are for test only, they may be discharged earlier than batteries you buy in stores. Replace all batteries at one time (as simultaneous set). Use only 1.5V AAA alkaline batteries. Remove batteries when unit is not in use for extended periods of time. Date and time will need to be reset if batteries are removed or replaced. Clean contacts on battery and in battery compartment with a soft dry cloth each time you install batteries.

Note: Batteries are hazardous waste. Do not dispose of them together with the household garbage.

DATE & TIME SET PROCEDURE

  1. To adjust the date/time, press the Set button Ⓑ. The display will show a blinking number showing the month.

  2. Change the month by pressing the button. Each press will increase the number by one in a cycling manner. Press the Set button again to confirm the entry, and the screen will show a blinking number representing the day of the month.

  3. Change the date and time as described in Step 2 above, using the + button to change the numbers and the Set button @to confirm the entries.

HOMEDICS BPW-060 - DATE &amp; TIME SET PROCEDURE - 1

flowchart
graph TD
    A["12/38PM 12/28"] --> B["+"]
    B --> C["repeat process to set date and time"]
    D["Press the @ button"] --> E["blinking month"]
    E --> F["increasing month"]
    F --> G["confirm the entry"]
    G --> H["repeat process to set date and time"]

APPLYING THE CUFF

  1. Remove all watches, wrist jewelry, etc. prior to attaching the wrist monitor. Clothing sleeves should be rolled up and the cuff should be wrapped around bare skin for correct measurements.

  2. Apply cuff to left wrist with palm facing up as shown in Fig. A.

  3. Make sure the edge of the cuff is about 1/4"\~1/2" (1 cm) from the palm as shown in Fig. B.

  4. In order to insure accurate measurements, fasten the hook and loop strap securely around your wrist so there is no extra space between the cuff and the wrist as shown in Fig. C. If the cuff is not wrapped tight enough, the measurement values will not be accurate.

  5. If your physician has diagnosed you with poor circulation in your left arm, place the cuff around your right wrist as shown in Fig. D.

Fig. A
HOMEDICS BPW-060 - APPLYING THE CUFF - 1

Fig. B
HOMEDICS BPW-060 - APPLYING THE CUFF - 2

Fig. C
HOMEDICS BPW-060 - APPLYING THE CUFF - 3

Fig. D
HOMEDICS BPW-060 - APPLYING THE CUFF - 4

CORRECT MEASUREMENT POSTURE

  1. Place your elbow on a table so that the cuff is at the same level as your heart as shown in Fig. A.

Note: Your heart is located slightly below your armpit.

Relax your entire body, especially between your elbow and fingers.

  1. If the cuff is not at the same level as your heart or if you cannot keep your arm completely still throughout the reading, use a soft object such as a folded towel to support your arm as shown in Fig. B.
  2. Turn your palm upwards.
  3. Sit upright in a chair, and take 5-6 deep breaths.

Note: Avoid leaning back while the measurement is being taken as shown in Fig. C.

Fig. A

Fig. B

Fig. C (X)

MEASUREMENT PROCEDURE

Important Notes:

  • Position the monitor at the same level as your heart during measurement to ensure accurate readings.
  • Blood pressure changes with every heartbeat and is in constant fluctuation throughout the day.
  • Blood pressure measurement can be affected by the position of the user, his or her physiologic condition and other factors. For greatest accuracy, wait 1 hour after exercising, bathing, eating, drinking beverages with alcohol or caffeine, or smoking to measure blood pressure.
  • Before measurement, it is suggested that you sit quietly for 15 minutes as measurements taken during a relaxed state will have greater accuracy. You should not be physically tired or exhausted while taking a measurement.
  • During the measurement, do not talk or move your arm or hand muscles.
  • See page 26 for additional notes regarding your blood pressure measurement.

If you are using this blood pressure monitor for the first time, please remove the protective film from the screen.

  1. Press the⊕ button to choose User 1 or User 2.

HOMEDICS BPW-060 - Important Notes: - 1

After the user number is selected, press the START/STOP button to confirm the chosen user.

  1. With the cuff wrapped around your wrist, press the START/STOP button. Do not inflate the cuff unless it is wrapped around your wrist. All digits will light up, checking the display functions. The checking procedure will be completed after about 3 seconds.

START STOP 888 18 28 96.1 18:88" 187:30 188 → 00 18 12:30" 6/15

  1. After all symbols disappear, the display will show "00". The monitor is "Ready to Measure" and will automatically inflate the cuff to begin measurement. The cuff will then begin deflating as measurement continues.

13:00 18 30 38~ 18 12:38" 6/15 11:00 18 12:38" 6/15

Note: The monitor will re-inflate automatically if the system detects that your body requires more pressure for measurement.

140 18 220 12:38" 6/15 12:38" 6/15

  1. When the measurement is completed, the cuff will deflate entirely and systolic pressure, diastolic pressure and pulse will be shown simultaneously on the LCD screen. The measurement is then automatically stored into memory.

HOMEDICS BPW-060 - Important Notes: - 5

Note:

  1. This monitor automatically turns off approximately 1 minute after last operation. You may also press the START/STOP button to turn the unit off.
  2. To interrupt the measurement, you may press the START/STOP button (recommended), "M", or Date/Time/User Set (◎/ +) buttons. The cuff will deflate immediately after a button is pressed.

RISK CATEGORY INDEX

This monitor comes equipped with a Risk Category Index that automatically compares each reading to defined levels established by the U.S. National Institutes of Health's (NIH) National Heart Lung and Blood Institute as described earlier in this manual, and provides a helpful cue if your reading falls into one of the stages that could potentially indicate increased risk. No cue is given if the reading falls in the normal range as defined by NIH. Please note that cues provided by this monitor are only intended to assist you in using this table. The table and cues are only provided for convenience to help you understand your non-invasive blood pressure reading as it relates to the NIH information. They are not a substitute for a medical examination by your physician. It is important for you to consult with your physician regularly. Your physician will tell you your normal blood pressure range as well as the point at which you may actually be considered to be at risk.

HOMEDICS BPW-060 - RISK CATEGORY INDEX - 1

Stage 2 Hypertension

HOMEDICS BPW-060 - RISK CATEGORY INDEX - 2

Pre-hypertension

HOMEDICS BPW-060 - RISK CATEGORY INDEX - 3

Stage 1 Hypertension

Normal (No Symbol)

RECALLING VALUES FROM MEMORY

This monitor can be used by two individuals. Each user can store up to 60 measurements.

  1. Press the ⊕ button.

HOMEDICS BPW-060 - RECALLING VALUES FROM MEMORY - 1

  1. Choose User 1 or User 2.

HOMEDICS BPW-060 - RECALLING VALUES FROM MEMORY - 2

  1. Press the "M" button to access the memory.

HOMEDICS BPW-060 - RECALLING VALUES FROM MEMORY - 3

  1. The monitor will first display the calculated average applied to the last 3 memories ("AVG. 3").

HOMEDICS BPW-060 - RECALLING VALUES FROM MEMORY - 4

  1. Every new press of the "M" button will recall a previous reading. The latest reading will be recalled first.

120 120 80 12:38 76 6/15

CLEARING VALUES FROM MEMORY

  1. Press the ⊕ button to select User 1 or User 2.

HOMEDICS BPW-060 - CLEARING VALUES FROM MEMORY - 1

  1. Press and hold the Ⓞ +buttons at the same time while in memory recall mode and the data for the selected user will be erased automatically.

and CLR M START STOP

IMPORTANT NOTES REGARDING YOUR BLOOD PRESSURE MEASUREMENT

• Take your reading in a comfortable environment as measurements can be affected by hot or cold temperatures. Take your blood pressure at normal body temperature.
- Do not move or talk during measurement as this can elevate readings.
- Do not move or cross legs during measurement. Keep feet flat on floor.
- Do not touch cuff or monitor during measurement procedure.
- It is suggested that you take your measurements at the same time each day and use the same wrist for consistency.
- Users should wait a minimum of 5 minutes before taking additional measurements. More time may be necessary depending upon your physiology.
- The measurement results that users receive are for reference only. If users have any blood pressure concerns, please consult a physician.

  • Once inflation reaches 300 mmHg, the unit will deflate automatically for safety reasons.
  • This device may have difficulty determining the proper blood pressure for users with irregular heartbeat, diabetes, poor circulation of blood, kidney problems, or for users who have suffered a stroke.

CARE, MAINTENANCE & CLEANING

  1. Clean the blood pressure monitor body and cuff carefully with a slightly damp, soft cloth. Do not press. Do not wash cuff or use chemical cleaner on it. Never use thinner, alcohol or petrol (gasoline) as cleaner.
  2. Leaky batteries can damage the unit. Remove the batteries when the unit will not be used for a long time.
  3. If the unit is stored near freezing, allow it to acclimate to room temperature before use.
  4. This blood pressure monitor is not field serviceable. You should not use any tool to open the device nor should you attempt to adjust anything inside the device. If you have any problems with this device, please contact HoMedics Consumer Relations (contact information on warranty page).

  5. Do not immerse the unit in water as this will result in damage to the unit.

  6. Do not subject the monitor and cuff to extreme temperatures, humidity, moisture, and direct sunlight. Protect from dust.
  7. Do not fold the cuff tightly.
  8. Do not disassemble the monitor or cuff. If in need of repair, refer to the warranty section of this manual.
  9. Do not subject the monitor to extreme shocks (do not drop on floor).
  10. Do not inflate the cuff unless wrapped around wrist.
  11. Do not wrap the cuff around body parts other than your wrist.
  12. Do not drop or insert any object into any opening.

  13. This monitor may not meet its performance specifications if stored or used outside of these temperature and humidity ranges:

- Storage Environment - Operation Environment

Temperature: Temperature:

-4°F\~158°F 50°F\~104°F

(-20^ 70^) (10^ 40^)

Humidity: Humidity:

Less than 90% RH 15%-90% RH

POTENTIAL FOR ELECTROMAGNETIC INTERFERENCE

To avoid inaccurate results caused by electromagnetic interference between electrical and electronic equipment, do not use the device near a cell phone or microwave oven.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause

HOMEDICS BPW-060 - POTENTIAL FOR ELECTROMAGNETIC INTERFERENCE - 1

natural_image No crossed-out illustration of a mobile phone symbol (no text or numbers present)

harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

TROUBLESHOOTING

If any abnormality arises during use, please check the following points:

SYMPTOMSPOSSIBLE CAUSESCORRECTION
Unit does not turn on when the START/STOP button is pushed.Batteries have run down.Replace them with two new AAA alkaline batteries.
Battery polarities have been positioned incorrectly.Re-insert the batteries in the correct positions.
EE measurement error symbol shown on display or the blood pressure value is displayed excessively low (or high).Cuff has been placed incorrectly.Wrap the cuff properly so that it is positioned correctly.
Did you talk or move during measurement?Measure again.Keep wrist steady during measurement.
Shaking of the wrist with the cuff on.
E1 error symbol shown on displayAir circuit abnormality.Measure again.
E2 error symbol shown on displayInflation pressure exceeding 300 mmHgSwitch the unit off, then measure again.
E3 error symbol shown on displayError determining measurement data.Measure again.

Note: If the unit still does not work, contact HoMedics Consumer Relations. Under no circumstance should you disassemble or attempt to repair the unit by yourself. Contact information for HoMedics Consumer Relations Department can be found on the warranty page (See page 34).

SPECIFICATIONS

Power Source:Two 1.5V DC (AAA) Alkaline batteries
Measurement Method:Oscillometric
Measurement Range:Pressure: 40~280 millimeters Mercury (mmHg)Pulse: 40~199 beats/minute
Accuracy:Pressure: ±3 mmHgPulse: ±5% of reading
Pressure Sensor:Semi-conductor
Inflation:Pump driven
Deflation:Automatic Pressure release valve
Memory Capacity:60 memories for each User (120 total)
Auto-shut-off:1 minute after last button operation
Operation Environment:Temperature: 50°F~104°F (10°C~40°C)Humidity: 15%-90% RH
Storage Environment:Temperature: -4°F~158°F (-20°C~70°C)Humidity: Less than 90% RH
Weight:0.30 lbs (136 g) (without batteries)
Wrist Circumference:5.3" - 7.7" (13.5cm - 19.5cm)
Dimensions:3.3"(L) x 2.9"(W) x 1.4"(H)84mm(L) x 74mm(W) x 35mm(H)
Internally Powered equipmentType BF EquipmentIPx0-No special protection against the ingress of waterNot suitable for use in presence of flammable anesthetic mixture with air, oxygen or nitrous oxide.Continuous operation with short-time loading.

Note: These specifications are subject to change without notice.

HOMEDICS

For service or repair, do not return this unit to the retailer. Contact HoMedics Consumer Relations at:

Mail: HoMedics, Inc. Service Center Dept. 168 3000 Pontiac Trail Commerce Township, MI 48390

Email: cservice@ homedics.com

Phone: 1-800-466-3342 Business Hours: 8:30am-5pm ET Monday-Friday

Distributed by HOMEDICS

HoMedics, Inc. 3000 Pontiac Trail Commerce Township, MI 48390

Printed in China

LIMITED FIVE YEAR WARRANTY

HoMedics sells its products with the intent that they are free of defects in manufacture and workmanship for a period of five years from the date of original purchase, except as noted below. HoMedics warrants that its products will be free of defects in material and workmanship under normal use and service. This blood pressure monitor meets the simulated measurement cycles test requirement per EN1060-3, part 8.10. This warranty extends only to consumers and does not extend to Retailers.

To obtain warranty service on your HoMedics product, mail the product and your dated sales receipt (as proof of purchase), postpaid, to the following address:

HoMedics Consumer Relations Service Center Dept. 168 3000 Pontiac Trail Commerce Township, MI 48390 No COD's will be accepted.

HoMedics does not authorize anyone, including, but not limited to, Retailers, the subsequent consumer purchaser of the product from a Retailer or remote purchasers, to obligate HoMedics in any way beyond the terms set forth herein. This warranty does not cover damage caused by misuse or abuse; accident; the attachment of any unauthorized accessory; alteration to the product; improper installation; unauthorized repairs or modifications; improper use of electrical/power supply; loss of power; dropped product; malfunction or damage of an operating part from failure to provide manufacturer's recommended maintenance; transportation damage; theft; neglect; vandalism; or environmental conditions; loss of use during the period the product is at a repair facility or otherwise awaiting parts or repair; or any other conditions whatsoever that are beyond the control of HoMedics.

This warranty is effective only if the product is purchased and operated in the country in which the product is purchased. A product that requires modifications or adoption to enable it to operate in any other country than the country for which it was designed, manufactured, approved and/or authorized, or repair of products damaged by these modifications is not covered under this warranty.

5year limited warranty

HOMEDICS

For service or repair, do not return this unit to the retailer. Contact HoMedics Consumer Relations at:

Mail: HoMedics, Inc. Service Center Dept. 168 3000 Pontiac Trail Commerce Township, MI 48390

Email: cservice@ homedics.com

Phone: 1-800-466-3342 Business Hours: 8:30am-5pm ET Monday-Friday

Distributed by HOMEDICS

HoMedics, Inc. 3000 Pontiac Trail Commerce Township, MI 48390

Printed in China

THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY. THERE SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS OR ANY OTHER OBLIGATION ON THE PART OF THE COMPANY WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY. HOMEDICS SHALL HAVE NO LIABILITY FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES. IN NO EVENT SHALL THIS WARRANTY REQUIRE MORE THAN THE REPAIR OR REPLACEMENT OF ANY PART OR PARTS WHICH ARE FOUND TO BE DEFECTIVE WITHIN THE EFFECTIVE PERIOD OF THE WARRANTY. NO REFUNDS WILL BE GIVEN. IF REPLACEMENT PARTS FOR DEFECTIVE MATERIALS ARE NOT AVAILABLE, HOMEDICS RESERVES THE RIGHT TO MAKE PRODUCT SUBSTITUTIONS IN LIEU OF REPAIR OR REPLACEMENT.

This warranty does not extend to the purchase of opened, used, repaired, repackaged and/or resealed products, including but not limited to sale of such products on Internet auction sites and/or sales of such products by surplus or bulk resellers. Any and all warranties or guarantees shall immediately cease and terminate as to any products or parts thereof which are repaired, replaced, altered, or modified, without the prior express and written consent of HoMedics.

This warranty provides you with specific legal rights. You may have additional rights which may vary from country to country. Because of individual country regulations, some of the above limitations and exclusions may not apply to you. For more information regarding our product line in the USA, please visit: www.homedics.com

©2008-2010 HoMedics, Inc. and its affiliated companies, all rights reserved. HoMedics is a registered trademark of HoMedics, Inc. and its affiliated companies. Smart Measure™ is a trademark of HoMedics Inc. and its affiliated companies. All rights reserved.

IB-BPW060C

5year limited warranty

HOMEDICS

natural_image Illustration of a mechanical component with a curved top and internal structure, no visible text or symbols

HOMEDICS BPW-060 - HOMEDICS - 1

natural_image Diagram of a mechanical component with a cylindrical body and a rod, labeled with number 2 (no text or symbols on the diagram itself)

3.

HOMEDICS BPW-060 - HOMEDICS - 3

natural_image Illustration of a medical device with a curved tube and arrow pointing to a component (no text or symbols)

Correo:
HoMedics, Inc.
Service Center
Dept. 168
3000 Pontiac Trail
Commerce Township, MI 48390

Correo electrónico: cservice@ homedics.com

HoMedics, Inc. 3000 Pontiac Trail Commerce Township, MI 48390

GARANTÍA LIMITADA POR CINCO AÑOS

HoMedics Consumer Relations Service Center Dept. 168 3000 Pontiac Trail

Commerce Township, MI 48390

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : HOMEDICS

Model : BPW-060

Category : Blood pressure monitor