| Product Type | Ultrasonic Air Purifier / Humidifier |
| Brand | Gorenje |
| Model | H08WB |
| Technology | Ultrasonic atomization for cool mist |
| Control Type | Button controls (Power, Setting) |
| Modes | Default high setting with adjustable levels |
| Indicators | Power indicator, refill indicator (red LED when water low) |
| Water Tank Capacity | Approximately 2–3 liters (estimation based on typical size) |
| Max Water Level Mark | MAX mark inside tank |
| Power Supply | AC 100–240V, 50/60Hz (typical for such devices) |
| Power Consumption | Approximately 25W (estimation) |
| Noise Level | Low, with possible noise if not level or low water |
| Placement | Flat, moisture-proof surface, at least 1 meter from walls |
| Operation | Plug in, press power button to start on high setting |
| Refill Method | Open top lid, fill tank to MAX, align gap with outlet |
| Daily Maintenance | Rinse tank, wipe base with cloth |
| Weekly Maintenance | Clean with white vinegar or recommended solution for 20 minutes; rinse |
| Sterilization | Use chlorine bleach solution in tank for 20 minutes, rinse thoroughly |
| Safety Features | Auto shut-off when water tank is empty (via refill indicator) |
| Child Safety | Only for use by children 8+ with supervision |
| Spare Parts | Ultrasonic transducer (membrane) replaceable |
| Warranty | Standard manufacturer warranty (check local terms) |
Frequently Asked Questions - H08WB GORENJE
User questions about H08WB GORENJE
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Air purifier in PDF format for free! Find your manual H08WB - GORENJE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. H08WB by GORENJE.
USER MANUAL H08WB GORENJE
INSTRUCTIONS FOR USE SI
INSTRUCTIONS FOR USE HR
INSTRUCTIONS FOR USE SRB
INSTRUCTION MANUAL EN
SL
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THE DEVICE FOR THE FIRST TIME.
IMPORTANT SAFETY INSTRUCTIONS
INSTRUCTIONS
Ultrasonic transducer membrane

INSTRUCTIONS
1. Description of button functions
READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS APPLIANCE FOR THE FIRST TIME.
SAFETY INSTRUCTIONS/IMPORTANT:
- Please read the instruction booklet carefully before using and save it for future reference.
- Before use, make sure that your outlet voltage corresponds to the voltage stated on the rating label.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- Do not let the cord hang over the edge of a table or counter, or touch hot surfaces.
- Do not place the humidifier on or near an electric burner, radiator, or fan heater.
- Place the humidifier at a place far away from the corner of the wall, at least 1 meter away from the wall.
- Do not place the humidifier in areas where children can reach them. Never place the humidifier in closed rooms, especially in the rooms where children rest, sleep and play, because the enclosed room may be excessively humid.
- Warning: Do not try to refill the water tank without unplugging it. Failure to follow the warning will result in personal injury. Pull the plug rather than the cord when applying tension to the plug.
- Do not cover the steam outlet with foreign objects while the humidifier is in operation.
- Do not throw or insert foreign objects into any openings of the humidifier.
- Unplug the appliance during filling and cleaning.
- Do not use the appliance for other than its intended use.
- Do not use outdoors.
- Please put the humidifier on a firm, flat horizontal surface. It is recommended to add a waterproof pad under the humidifier. Never place the humidifier on a carpet or a smooth floor to prevent water or fog from damaging the floor.
- The mist outlet shall not face the wall directly. Water mist may damage the wallpaper.
- Care should be taken when using the appliance due to the emission of hot water vapour.
- CAUTION: Hot water vapour.
- Unplug the appliance when it is not operated.
- Do not tilt, move or empty the water tank when the humidifier works. Please cut off the power supply when moving the water tank or appliance.
- The humidifier should be maintained daily and weekly following the operation described in "CLEANING AND MAINTENANCE".
- Do not use any detergents, gasoline, glass cleaners, furniture brighteners, paint thinners or other dissolving agents to clean any parts.
- Excessive humidity in the room will cause condensation of windows and furniture. If this happens, please turn off the machine.
- It is suggested that humidifiers should not be used when humidity is greater than 65%, and excessive hu-
midification may occur if they are exceeded.
- Do not repair or regulate electronic and mechanical properties without authorization.
- Do not rinse the base under the water or immerse it in the liquid.
- Do not plug in or unplug with wet hands.
- Do not place the appliance on a dangly table to avoid damaging it.
- Do not run the appliance without water in the water tank.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Save these instructions.
- This appliance is designed for domestic use under normal operating conditions.
PRODUCT PRESENTATION

INSTRUCTIONS
1. Button description
1.1 Power button: To turn on and turn off the appliance. 1.2 Setting button: To set the corresponding setting.
2. Function description
2.1 Plug in: After the appliance is plugged in, one beep can be heard and the appliance enters the standby condition, at that time, the “Power button” works while the “Setting button” is invalid. 2.2 Power on/Power off: Press the “Power button” once, the appliance will start working under the default high setting, at the time, the corresponding indicator will light up. 2.3 A short beep can be heard after every valid press of the button. 2.4 Refill indicator: The refill indicator will illuminate in red when the water tank is lack of water. At that time, you should refill the water tank with water. The appliance can only work normally after refill the water tank and restart the appliance.
3. Preparation before power on
3.1 The working principle is that the ultrasonic wave atomizes water to produce visible cold mist which is sprayed from the mist outlet. 3.2 The humidifier should be put at a flat and moisture-proof place which is above one meter from the wall. 3.3 Open the top lid and fill the water tank with water to the "MAX" mark, align the gap with the outlet (Fig. A), then close the top lid.
NOTE: Overflow will occur or no mist come out if the water level exceed the "MAX" mark.
3.4 Connect the appliance with power source. 3.5 Start the humidifier according to the instruction of control panel.
CLEANING AND MAINTENANCE
1. Daily maintenance
1.1 Make sure the humidifier is powered off and unplugged. 1.2 Take the water tank to the side of the faucet, empty the residual water and rinse the water tank, then wipe and clean the base with a cleaning cloth or towel. 1.3 Refill the water tank with clean water and replace it well in position.
2. Weekly maintenance
2.1 Repeat the operation of "Daily maintenance". 2.2 Add a small cup (about 200ml) of undiluted white vinegar or cleaning solution recommended by the manufacturer into the water tank. After 20 minutes, clean the water tank and the dirt near the atomizer with a cleaning cloth. 2.3 Before sterilizing, remove the cleaning solution with warm water with a temperature less than 70°C and re-sterilize it with water.
3. Sterilization of the base and water tank
3.1 Fill the water tank with 1/2 of fresh water and add 1/2 tablespoon of chlorine bleach. 3.2 Make the solution stay in the water tank for 20 minutes and rinse it for a few minutes to ensure that each inner surface can be washed. 3.3 After 20 minutes, empty the water tank and wash it with lukewarm water until no disinfectant smells. Wipe the tank with a cloth or paper. 3.4 Refill the water tank and replace it well in position. 3.5 Clean the base and empty the excess water, remove deposits and dirt completely, and wipe it
with a cloth or a piece of paper, do not clean the base with metal ware or abrasives.
NOTE: Do not immerse the water tank and base into the water for cleaning. When you want to pour out any excess water from the water tank:

Please note: Excess water should be poured out of the front of the water tank to prevent water entering air vents.
TROUBLESHOOTING
| Problem | Possible cause | Solution |
| No power/no mistFrom spout | Unit is not plugged in No power at unit Add water exceed the “MAX” mark. Transducer/ultrasonic membrane needscleaning | Plug unit in Press the power button to turn the uniton Reduce some water below the “MAX” level Follow cleaning the water tank according to daily maintenance; because Transducer/Ultrasonic islocated on the bottom of the tank. |
| Peculiar odor | If unit is in use, the odor may be a dirty tank or old tank water | Empty the old water, clean the tank, and fill with clean water |
| Excessive noise | Unit is not level Low water level | Place unit on a flat even surface Check the water level, refill the tank if the water is low |