Seaward PH3-LLT MK2 - Measurement

PH3-LLT MK2 - Measurement Seaward - Free user manual and instructions

Find the device manual for free PH3-LLT MK2 Seaward in PDF.

📄 2 pages English EN Download 💬 AI Question
Notice Seaward PH3-LLT MK2 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about PH3-LLT MK2 Seaward

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measurement in PDF format for free! Find your manual PH3-LLT MK2 - Seaward and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PH3-LLT MK2 by Seaward.

USER MANUAL PH3-LLT MK2 Seaward

Output Voltage500V DC (depending on battery condition)
Output Current10mA DC into 2kΩ
IndicatorLED indication of voltage active
Dimensions41mm (h), 82 (w), 157mm (d)
Power Supply9V DC, PP3 Alkaline Battery
IP Rating40
ComplianceBS EN 61010

5 Maintenance

Clean only with a dry cloth; do not use solvents. Before use, ensure unit is clean and dry; visually inspect test terminals and case. Any damage must be rectified to preserve user safety.

Check the battery contacts and compartment is free of electrolytic contamination.

Any contamination of the battery contacts or compartment should be cleaned with a dry cloth.

Always confirm that the LED indicator on the proving unit illuminates when the test is activated. Should the item become faulty do not open, return it to the manufacturer or an authorised Seaward Service Agent.

6 Battery Replacement

  • Disconnect all test leads.
  • Remove the battery compartment cover
  • Remove the discharged battery.
  • Insert the replacement battery into the battery compartment ensuring that the battery polarity matches the battery connector.
  • Replace the battery compartment cover.

7 Service and Calibration

To maintain the specified performance, the instrument must be verified at regular intervals by either the manufacturer or an authorised Seaward Service Agent. We recommend a calibration period of one year.

For help or advice on Service and Calibration contact:

Service Department

Seaward Electronic

Bracken Hill

South West Industrial Estate

Peterlee

Co Durham SR8 2SW

England

Tel: 0191 5878739 / 0191 5878737

Email: service@seaward.com

Web: www.seaward.com

PH3-LLT MK2

Proving Unit

Operating Instructions

Seaward PH3-LLT MK2 - Operating Instructions - 1

SEAWARD

TESTED, TRUSTED... WORLDWIDE.

Bracken Hill

South West Industrial Estate

Peterlee

Co Durham

SR8 2SW

ENGLAND

Tel: +44(0)191 5863511

www.seaward.com

sales@seaward.com

service@seaward.com

Part Number 423A651 Revision 4

© 2022 Seaward Electronic Ltd

Limited Warranty & Limitation of Liability

SEAWARD Electronic Limited guarantees this product to be free from defects in material and workmanship under normal use and service for a period of 1 year. The period of warranty will be effective at the day of delivery.

(c) Copyright 2022

All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from SEAWARD Electronic Limited. This also applies to accompanying drawings and diagrams.

Due to a policy of continuous development SEAWARD Electronic Limited reserves the right to alter the equipment specification and description outlined in this publication without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract.

1 Important Information

In the interest of safety the PH3-LLT MK2 should only be used by competent suitably trained personnel after due consideration of any hazard involved.

The following symbols are used in these operating instructions and on the PH3-LLT MK2.

Seaward PH3-LLT MK2 - Important Information - 1

Warning of electrical danger! Indicates instructions must be followed to avoid danger to persons.

Seaward PH3-LLT MK2 - Important Information - 2

Important, follow the documentation! This symbol indicates that the operating instructions must be consulted and adhered to in order to avoid danger.

Before use, ensure that both the PH3-LLT MK2 and the LLT MK2 are clean and dry. Visually inspect all parts of the PH3-LLT MK2, if any parts are damaged do not use the PH3-LLT MK2.

Seaward PH3-LLT MK2 - Important Information - 3

Do not hold LLT (Live Line Tester) MK2 between the hand-guard and the contact electrode.

Seaward PH3-LLT MK2 - Important Information - 4

Electrical shock risk! Do not touch terminals!

Seaward PH3-LLT MK2 - Important Information - 5

Always prove the LLT MK2 before AND after use.

Seaward PH3-LLT MK2 - Important Information - 6

Always check that the LED indicator on the proving unit is illuminated whilst testing.

Seaward PH3-LLT MK2 - Important Information - 7

If the equipment is not used in a manner specified in the manual, the protection provided may be impaired.

Seaward PH3-LLT MK2 - Important Information - 8

Do not use without battery compartment cover fitted.

Do not energise the proving unit for longer than 5 seconds, to preserve the battery.

WEEE Directive

Seaward PH3-LLT MK2 - WEEE Directive - 1

This product has been designed and manufactured with high quality materials and components, which can be recycled and reused.

When this symbol is attached to a product it is covered by the WEEE Directive.

Please familiarise yourself with the appropriate local separate collection system for electrical and electronic products. Please dispose of this product according to local regulations. Do not dispose of this product along with normal waste. The correct disposal of this product will help prevent potential negative consequences for the environment and human health.

2 Environmental conditions

PH3-LLT MK2 was designed to perform tests:

• In a dry environment.
• At altitude of up to 2000M.
- At temperature of 5-40°C without moisture condensation.

3 Proving

The PH3-LLT MK2 is intended to check if a LLT MK2 functions correctly.

  1. Insert each probe of the LLT MK2 inside the PH3-LLT MK2 terminals.
  2. Press down on the right terminal (closest to the battery compartment) to switch on the PH3-LLT MK2.

  3. Confirm the LED on the PH3-LLT MK2 front panel is illuminating.

  4. If LED does NOT illuminate, replace the battery by following 6 Battery Replacement instruction.
  5. If LED still does NOT illuminate, this suggests PH3-LLT MK2 is faulty. DO NOT USE.
  6. Confirm the Dual LEDs on LLT-PH3 are illuminating. If Dual LEDs are NOT illuminating, this suggests LLT MK2 is faulty. DO NOT USE.
  7. Disconnect both probes from the terminals after test is complete.

LEAMARD ELECTRIC SWITCH AND NO. NO. 100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 NO. NO. 15432876988888888888888888888888888888888888888888888888888888888888888888888888888888

Image above shows PH3-LLT MK2 before switched on.

SEAWARD ELECTRIC ENCH & IN SPEED BOUNT REMOGRANATE NO PENSICING CABBERS OF NOT EQUISICUM NO. SPRING THAN 5 MECLOS CC 遵正

Image above shows PH3-LLT MK2 switched on when the right terminal is pushed down.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Seaward

Model : PH3-LLT MK2

Category : Measurement