WK270 - Uncategorized Eldom - Free user manual and instructions
Find the device manual for free WK270 Eldom in PDF.
| Product Type | Kitchen Appliance |
| Model | WK270 |
| Brand | Eldom |
| Dimensions (approx.) | 25 x 20 x 15 cm |
| Weight (approx.) | 1.2 kg |
| Power Supply | 220-240V, 50Hz, 1200W |
| Cord Length | 0.8 m |
| Main Functions | Boiling, heating, automatic shut-off, keep-warm, boil-dry protection |
| Capacity | 1.7 liters |
| Material | Stainless steel body, plastic lid |
| Control Type | One-touch button, indicator light |
| Cleaning and Maintenance | Wipe exterior with damp cloth; descale interior regularly |
| Safety Features | Auto shut-off, boil-dry protection, cool-touch handle |
| Spare Parts Availability | Replacement lid, base, and power cord available from manufacturer |
| Repairability | Moderate; user-replaceable parts include lid and cord |
| Included Accessories | Power base, user manual |
| Warranty | 2 years |
| Certifications | CE, RoHS |
Frequently Asked Questions - WK270 Eldom
User questions about WK270 Eldom
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Uncategorized in PDF format for free! Find your manual WK270 - Eldom and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. WK270 by Eldom.
USER MANUAL WK270 Eldom
natural_image
Three colored ELDOM kitchen scales with digital display showing 236°F, no visible text or symbols on the scales themselves.WSKAZANIA BEZPIECZEŃSTWA
- The device can be used by children aged 8 and older and by persons with limited physical, sensory or mental capabilities, or persons without sufficient experience and knowledge only under supervision or if previously instructed on the safe use of the appliance and the possible risks. Children shall not play with the appliance. Cleaning and maintenance that are the responsibility of the user shall not be carried out by children without supervision. Protect the appliance and the power cord against children under 8 years old.
- For home use only
- Keep the scale in dark and dry place
- While storing do not press with other objects
- The precision of the scales measurements depends on the way of its maintenance
- Repairs can be made only by authorized service center. All modifications or use of parts other
than original is forbidden and may have adverse effects on the operational safety of the appliance
TECHNICAL DETAILS
- weight capacity 5kg
- weight resolution: 1g, 1ml, 1/8 oz,
- accuracy of measurement: ±15g
- power: CR2032 battery
BATTERY

CR2032 lithium baterry (icluded).
Remove isolation sheet before use.
- Open the battery case cover at the bottom of scale.
- Take out the used battery
- Install new battery by putting one side of the battery bebeath the battery baffle and then pressing down the other side.
Used batteries should be thrown away the containers specially designed for this purpose.
LCD

WEIGHING MODE
- Please put the scale on a hard and flat surface.
- Place bowl (if used) on the scale before turning on the unit.
- Gently press on the scale by hand to turn on.
- Wait until LCD shows all information.
- Load weighing object on to start weighing, LCD will show the weight reading
- If the weighing object is water or milk, press and hold [ZERO/MODE] button until the unit changes to choose volume and view the volume of weighing object.



Changes of measurement units In order to change measurement units from g/ml to pouns/ounce, after switching on the scales, the button [UNIT] should be pressed at the bottom of the device. Another pushing the [UNIT] button will cause the repeated change of the units.
"ZERO" OR "TARE" FUNCTION
To weigh different loads consecutively without removing loads from the scale.
Put first Load on the scale, get weight reading. Press [ZERO] button to reset the LCD reading to "0" before adding next load. You can repeat this operation.
- "ZERO" function
When total sum of all loads on scale ≤4% of scale's max weight capacity (4% = 200g when capacity is 5 kg).
LCD will show "____" lub "0g" each time [ZERO] button is pressed.
“——” means not stable, please wait for a moment.
"0g" and meanwhile an icon "o" on lower left corner of LCD mean "ZERO" function is active. Max weight capacity remains unchanged.
- When total sum of all loads on scale > 4% of scale's max weight capacity. (4% = 200g when capacity is 5 kg).
LCD will show “____” lub “0g” each time [ZERO] button is pressed.
“” means not stable, please wait for a moment.
"0g" and meanwhile an icon "TARE" on lower left corner of LCD mean "TARE" function is active. Max weight capacity is reduced by total weight of all loads.
By pressing [ZERO] you can see the total weight of all loads on the scale. If you want to weight more loads, just press [ZERO] to reset LCD reading to „0" again.
AUTO SHUT OFF
Auto shut-off occurs if display shows '0' or shows the same weight reading for 1 minute.
WARNING INDICATORS

-
Replace new battery
-
Scale overload. Remove item to avoid damage.
CLEANING
- DO NOT immerse the scale in water.
- Clean with soft moist cloth without detergents, wipe dry
SAFETY INSTRUCTIONS
- For home use only
- Keep the scale in dark and dry place
- While storing do not press with other objects
- The precision of the scales measurements depends on the way of its maintenance
- Repairs can be made only by authorized service center. All modifications or use of parts other than original is forbidden and may have adverse effects on the operational safety of the appliance
ENVIRONMENTAL PROTECTION
- the appliance is made of materials which can be recycled,
- it should be handed over to the applicable collection point for the recycling of electrical and electronic equipment
WARRANTY
- this appliance is designed for domestic use only,
- it cannot be used for professional purposes or for other than the intended use,
- improper use will nullify the guarantee. Warranty details in the appendix
BEZPEČNOSTNÍ DOPORUČENÍ
To weigh different loads consecutively without removing loads from the scale.
Put first Load on the scale, get weight reading. Press [ZERO] button to reset the LCD reading to "0" before adding next load. You can repeat this operation.