UFESA IT-122 - Thermometer

IT-122 - Thermometer UFESA - Free user manual and instructions

Find the device manual for free IT-122 UFESA in PDF.

📄 38 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice UFESA IT-122 - page 10
View the manual : Български BG English EN Español ES Português PT
Pick your language and provide your email: we'll send you a specifically translated version.
Brand Ufesa
Model IT-122
Product Type Home Appliance
Power Supply 220-240 V ~ 50 Hz
Power Consumption 800 W
Dimensions (W x D x H) 20 x 15 x 10 cm
Weight 1.2 kg
Material Plastic and stainless steel
Control Type Manual knob
Speed Settings 2 speeds + pulse
Safety Feature Overheat protection
Non-slip Feet Yes
Cord Length 1.0 m
Dishwasher Safe Parts Yes (detachable jug)
BPA Free Yes
Warranty 2 years
Manual Languages EN, ES, PT, BG

Frequently Asked Questions - IT-122 UFESA

How do I clean the device?
Unplug the device and wipe the exterior with a damp cloth. The removable jug can be washed in warm soapy water or in the dishwasher. Do not immerse the base in water.
Can I use the IT-122 for hot liquids?
No, the device is designed for cold or room temperature liquids only. Using hot liquids may damage the appliance or cause injury.
What is the maximum capacity of the jug?
The maximum capacity is 1.5 liters. Do not exceed the max line indicated on the jug to avoid spillage.
How do I replace the blade assembly?
The blade assembly is not user-replaceable. If the blades become dull or damaged, contact Ufesa customer service for assistance.
Why does the appliance stop working suddenly?
The device may have an overheat protection feature. If it stops, unplug it and let it cool for at least 30 minutes before using again. Also check for blockages.
Is it safe to leave the appliance plugged in when not in use?
For safety, always unplug the appliance when not in use. Do not leave it unattended while plugged in.
Can I use the appliance continuously for long periods?
The device is designed for intermittent use. Do not operate it continuously for more than 2 minutes without a break. Let it cool down between uses.
What should I do if the appliance does not start?
Check that it is properly plugged into a working outlet. Ensure the jug is correctly locked into place. If it still does not start, contact customer support.
How should I store the appliance?
Store the appliance in a dry place away from direct sunlight. Keep the cord wrapped loosely around the base or stored separately to avoid damage.
Where can I find spare parts or accessories?
Spare parts and accessories can be purchased from authorized Ufesa dealers or through the official Ufesa website. Provide the model number IT-122 when ordering.

User questions about IT-122 UFESA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Thermometer in PDF format for free! Find your manual IT-122 - UFESA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. IT-122 by UFESA.

USER MANUAL IT-122 UFESA

infrared thermometer

IT-122

Body temp 888.8 °C LOG 888.8 1 2 3 4 5 7 6 MODE 9 8

AVISO IMPORTANTE

Read the instructions carefully before using the product. Keep them in a safe place for future reference.

Only specialized personnel should perform repairs to this electrical appliance. Any incorrectly performed repair can lead to considerable hazards for the user. Always contact the after-sales service authorized by B&B Trends for repair.

Failure to observe these instructions will lead to the total loss of the product warranty.

In no way should this device be used as a substitute for medical treatment.

The measurements obtained are informative. Provide this information to your doctor. Do not take a medical decision on your own (for example modify the medication)

Children must be supervised by an adult to prevent them using the appliance as a toy.

Only use the device for the purposes indicated in this instruction manual.

Never point towards the eyes. The infrared light can damage your optical system.

This device is designed for domestic use, not professional use.

Do not use the device near other equipment that might cause interference

Do not allow the product to come into contact with any type of liquid.

Do not expose the device to extreme electrical charges or temperatures ( >50ircC or <0ircC ).

This device should be used at an ambient temperature of between 10irc C and 40irc C.

The device must not be subjected to heavy falls or knocks. The shelf life of the product depends on how the device is handled (beating, cleaning, etc.)

Do not use the device if any internal or external damage is observed. Check, that the lens is undamaged before each use. In the event of any damage contact an authorized technical service.

Check that the low battery indicator does not flash when turning on the product to be used. If so, change the batteries.

UFESA IT-122 - Read the instructions carefully before using the product. Keep them in a safe place for future reference. - 1

In order to prevent any risk of danger, do not handle the product. Only qualified technical personnel from the brand's Official Technical support service may carry out repairs or procedures on the

device.

Any incorrect use or improper handling of the electric blanket shall render the warranty null and void. Only an authorized technical support service centre may carry out repairs on this product.

B&B TRENDS SL accepts no liability for any damage that may be caused to people, animals or objects owing to failure to observe this warning correctly.

GENERAL INFORMATION:

The IT-122 thermometer is designed to read the body temperature on the forehead as well as of objects.

First check that the appliance is complete and undamaged. Contact the store where you purchased the product in the event of any doubt.

With your purchase you have acquired:

• 1 IT-122 Infrared thermometer
• 1 Instruction manual.

Appliance description:

  1. Trigger to turn on and take reading
  2. Cover for the battery compartment.
  3. Reading mode. Surface (objects) or body.
  4. Results.
  5. Storage position.
  6. Up key
  7. Lighting key.
  8. Reading mode key.
  9. Down key
  10. Value stored in the memory.
  11. Level of charge in the batteries.
  12. Units (°C Celsius).
  13. Sound signals.

ENGLISH

INSTRUCTIONS FOR USE

Before using the product for the first time, make sure that there is no apparent damage to any of the parts. If the device is damaged, please contact our aftersales service or one of the authorized distributors.

Remove the product from its original packaging taking special care not to damage any of its parts. Do not use excessive force to remove the product from the box.

Before taking any measurements, the thermometer should be in place where the measurement is to be taken for at least 30 minutes. This prevents temperature changes in the components of the product from affecting the result.

This product performs temperature measurement in direct mode.

Regular body temperature values:

The IT-122-contactless thermometer allows the taking of temperature of different types of objects such as the body temperature of a person. Body temperature varies in each individual due to various factors such as sex, age, skin type, time of day, regular level of physical activity or diet.

Take a reading:

Follow the instructions that are presented below in order to take a reading:

  1. Place on the surface of whatever you wish to know the temperature and take a reading by pulling the trigger of the gun (1). If it is a body temperature it is recommended to take the temperature by directly applying it to the forehead from a distance of between 5 and 8cm. Make sure that there are no elements that can influence the incorrect reading of the temperature (sweat, hai r, make-up, piercings or other objects).

  2. Read the value of the reading given by the thermometer. Make sure that the reading mode indicated is correct (3). If the temperature of an body has been taken Body temp, should appear and if on the contrary an object temperature has been taken Body temp. should not appear. In the case that the correct mode is not indicated, it should be changed by pressing the Mode key (8) and the reading taken again.

Repeat the reading if you do not trust the validity of the reading values. In the event that you believe that the results are not correct, take the appliance to a Technical Support Service. This product cannot be calibrated by the user.

The product will automatically turn off after a few seconds without pressing the keys.

Replacing the batteries:

Open the cover of the compartment located on the handle of the thermometer and insert two AAA batteries. Close the cover once the battery has been introduced. Carry out this task when the battery has run out or when the low battery symbol appears on the LCD screen (11).

Error messages:

When you take a temperature reading using this thermometer one of two error messages shown below may appear:

“Hi” (High) indicates that the average value surpasses the maximum value of

UFESA IT-122 - Error messages: - 1

the range of readings. If the Body Temp mode is selected it indicates that the temperature is higher than 42.9irc C. Otherwise, if

Surface/object mode is selected the device is indicating that the temperature is higher than 100irc C.

UFESA IT-122 - Error messages: - 2

“Lu” (Low) indicates that the average value is lower than the maximum value of the range of readings. If the Body Temp mode is selected it indicates that the temperature is lower than 32irc C.

Otherwise, if Surface/object mode is selected the device is indicating that the temperature is higher than 0irc C.

Occasionally the surface temperature that is being measured is not really found outside the range of temperatures but the thermometer interprets it as such and one of the above error messages is shown. Below some of the reasons for this and how to solve them are shown:

CAUSE SOLUTION
Too much distance between the thermometer and the surface.Take the reading again respecting the reading distance (5-8cm).
There has been a sudden change in temperature on the thermometer.Leave the thermometer in the room where the reading is to be taken for around 30 minutes so it can acclimatise and take the temperature again.

ENGLISH

The temperature has been taken on a bright surface.The reading of polished or shiny surfaces cannot be taken with the infrared thermometer. Take the temperature using other means.
When taking the body temperature sweat, hairs, piercings or any other element that can distort the thermometer reading is detected.Remove any possible element from the area that can cause an incorrect reading of thermometer and take the reading again.
The lens has become dirtyCarefully clean the lens

In case of doubt in the use, maintenance, configuration or device malfunction, contact an authorized service centre or contact us via the web www.ufesa.es

Memory management:

This device relies on space to store a total of 32 temperature values. The values are automatically saved as the readings are taken and in the case that the memory is full the newest reading will replace the oldest. Each time a reading is taken this appears on the lower right part (10) of the LCD screen and its storage position appears on the lower left hand corner (5).

Press on the keys (6) and (9) when the thermometer is on to access the memory. You can move through all stored readings using both keys.

Settings:

You can access the settings menu of the device to change the temperature units, to configure an alarm, to calibrate the device or to activate/deactivate the sound. To access this menu you must press the MODE key (8) for a couple of seconds. "F1" will appear on the screen after a beep. It is the firstelement that can be adjusted. By pressing the Mode (8) key again you will be able to move through the settings menu and go through the rest of the configurable elements.

F1. Setting the alarm: once inside the settings menu, when “F1” appears on the screen the device will be ready for you to select the body temperature from which you wish the acoustic alarm sound when a reading is taken. By pressing the up (6) and down (9) keys you can modify the warning temperature by intervals of 0.1°C. The predetermined value is 38°C.

F2. Calibrate the device: Contact an authorized technical service in case the product shows abnormal temperatures.

F3. Activate/deactivate sound: Once inside the settings menu, when “F3” appears on the screen the device will be ready for you to activate or deactivate the sound from the device. By pressing the up key (6) or down key (9) the sound will be activated or deactivated.

F4. Changing modes: Once inside the settings menu, when “F4” appears on the screen the device will be ready for you to calibrate. By pressing the up key (6) or down key (9) the device will change between body temperature or surface/object (SurF).

DATOS TÉCNICOS

Range of readingBody mode: 32.0°C - 42.9°C (109.2°F)Surface mode: 0.0°C - 100.0°C (212.0°C)
PrecisionBody mode: ±0.2°CSurface mode: ±1°C
Screen resolution0,1°C
Memories32
Operating ConditionsFrom 10°C to 40°CHumidity less than 80%
Storage and transport conditionsFrom -25°C to 55°CHumidity less than 90%
Power2 AAA batteries (LR03)
Auto-power off30 s
Time of reading0,5 s

This product complies with the European Directive of medical product 93/42/EEC.

ENGLISH

STORAGE AND DISPOSAL OF THE PRODUCT

PRODUCT STORAGE

Store the product in a clean, cool, dry environment.

Remove the batteries if you do not plan to use the appliance for an extended period of time.

PRODUCT CLEANING

This product can only be cleaned by hand, using a soft damp cloth and mild soap. The use of abrasive cleaning products or brushes, solvents, benzine, thinner or alcohol is completely prohibited. Never immerse the appliance or any of its parts in water or excessively moisten it in order to clean it. Do not re-use the appliance until it is completely dry.

Make sure to dry the product well after cleaning it, ready for use or storage.

Keep the lens clean and free of dust.

PRODUCT DISPOSAL

Do not dispose of the product in the rubbish at the end of its shelf-life. Contact the organic collection centre nearest your home in accordance with the Waste Electrical and Electronic Equipment (WEEE) Directive 2012/19/EU to contribute to the protection of the environment.

Request detailed information regarding the current methods for disposing of packaging and used devices from your distributor.

We hope that you will be satisfied with this product.

PORTUGUÊS

AVISO IMPORTANTE

Carefully read the instructions for use.

The product may contain batteries. Remove them before disposing of the product and dispose in special containers approved for this purpose.

Protect from moisture.

The EC marking certifies that complies with directive 93/42/EEC.

2460

Authorized Representative in the EU.

Elimination of waste according to the European directive 2012/19/UE on waste electrical and electronic equipment.

Forehead measurement.

Storage temperature margins.

Margens de temperatura de armazenamento.

ADD: 4th Floor, 11block, Tongfuyu Industrial Park, Lezhujiao, Baoan, Shenzhen, China.

UFESA IT-122 - AVISO IMPORTANTE - 1

MedNet GmbH, Borkstrasse 10, 48163, Münster, Germany

CE 2460

BOLETÍN DE GARANTÍA

B&B TRENDS, SL. guarantees compliance of this product for the purpose for which it is intended for a period of two years for the entire Spanish territory. In the case of breakdown during the term of this warranty, you are entitled to repair or to the replacement of the product at no charge if the former is unavailable, unless one of these options prove impossible or disproportionate. In this case, you can then choose a reduction in price or cancellation of the sale, which must be dealt with directly with the sales vendor. This also covers replacement of spare parts provided that the product has been used according to the recommendations specified in this manual for both cases, and has not been tampered with by any third party that is unaccredited by B&B TRENDS, SL. This warranty does not affect your rights as a consumer in accordance with the provisions of Law 23/2003 dated 10 July 2003 on warranties on the sale of consumer goods in the Spanish territory.

USE OF WARRANTY

Consumers should contact a technical service centre authorised by B&B TRENDS, SL. for repair of the product as any tampering thereof by persons not authorised by B&B TRENDS, SL., as well as misuse or inappropriate use, will lead to the cancellation of this warranty. The warranty must be fully completed and delivered along with the receipt or delivery docket for the effective exercise of rights under this warranty.

Claims must take place within three years from delivery of the product according to the provisions of the warranty, and the consumer must inform the sales vendor of the lack of conformity, provided that such claim is made within the statutory period of warranty. This warranty should be retained by the user as well as the invoice, receipt or the delivery docket to facilitate the exercise of these rights. For technical service and after-sales care outside the Spanish territory, please submit your query to the point of sale where you purchased the item or by contacting B&B TRENDS, SL.

BOLETIM DE GARANTIA

Sales establishment stamp

Technical Assistance Service (TAS)

902 997 053

A CORUÑA

15009 LA CORUÑA

EUGENIO SUAREZ SERANTES

S.L.U.C/ REIS CATOLICS, 72

971 24 76 95

satbalear@ono.com

BARCELONA

08015 BARCELONASUBMIN.

ELECTRICS DA MAU, S.C.P -

SATVILADOMAT, 108 BAIXOS

934 539 276

sdalmau@ono.com08025 BARCELONA

ELECTRICA FUSTER

PROVENZA, 538-540

934 564 736 fuster_garcia@hotmail.

com

08950 ESPLUGUES DE LLOBREGAT

ELECTRICAS FELIU SANT ALBERT

MAGNE,12-14 TD.2-B

933 722 302

feliusat@9chip.com

08950 ESPLUGUES DE LLOBREGAT S

AT J. BAUTISTA, S.L.

P.I. DOMENYS I, NAVE 9

938 904 852

fred@fredvilafranca.com

08800 VILANOVA I LA GELTRU

BIRME

AIGUA, 4938

930 011

birme@birme.com

BURGOS

SUREDA | ASSOCIATS, S.C. - SAT

FRANCESC ARTAU, 2

972 236 588

resured@terra.com

17200 PALAFRUGELL

NEW MERESA

CI.DE LA SURERA BERTRAN, 23

972 304 454

info@newmeresa.com

17740 VILAFANT ELECTRONICA

VILAFANT - SATNAVATA, 13

972 506 515

electronicavilafant@hotmail.com

GRANADA

18007 GRANADA

ELECTRICIDAD MORENO

C/ Palencia n° 3

GUADALAJARA

19004 GUADALAJARA

FERRETERIA AL-YE - SAT

AVDA.DEL EJERCITO,11-D,POSTER.

949 218 662

GUIPUZCOA

20600 EIBAR

EIBARSAT, C.B.IFAR KALE, 8

943 206 717

fg@euskalnet.net

20014 SAN SEBASTIAN

SANTIAGO ESTALAYO Y OTROS, C.B.-SAT

P° UBARBURU, n° 30, PAB C, POL 27

943 475 013

santiagoestalayo@hotmail.com

20002 SAN SEBASTIAN

GROSTON, S.L.

USANDIZAGA, 29

943 272 736

groston@hotmail.es

20001 SAN SEBASTIAN S.A.T.

TEJEDOR GLORIA, 4 (GROS)

943 287 193

j.ramon-tejedor@gmail.com

JAEN

23008 JAEN

C/VALLE INCLAN, n° 32, Local

917 054 624

pimaruno@gmail.com

28017 MADRID

ALTOHA

JOSE ARCONES GIL, 13

913 774 645

ramon@altoha.es

MILAGA

29010 MALAGA

CAMBEL ELECTRONICA

MORALES VILLARRUBIA, 17

952 277 247

cambel.electronica@gmail.com

MURCIA

3030D CARTAGENA

FASEPA.S.L.

PROLONGACION ANGEL BRUNA, 6 BJ

(BARRIO PERAL)

868 095 680

luserrano@fasepa.es

30009 MURCIA

SEBA C.B.

MARDEL RIAS BAIXAS, S.L.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : UFESA

Model : IT-122

Category : Thermometer