AN-PAC07C2 - Air conditioner Aconatic - Free user manual and instructions
Find the device manual for free AN-PAC07C2 Aconatic in PDF.
| Product Type | Portable Air Conditioner |
| Brand | Aconatic |
| Model | AN-PAC07C2 |
| Refrigerant Type | R290 (Flammable) |
| Cooling Modes | Cool, Fan, Dry |
| Temperature Range (Cool) | 18°C - 32°C (64°F - 90°F) |
| Fan Speeds | High (F2) and Low (F1) |
| Timer | 0.5 - 24 hours (delay start/stop) |
| Remote Control | Included (AAA batteries) |
| Sleep Mode | Yes (gradual temperature adjustment) |
| Anti-Mold Function | Yes (20 seconds after shutdown) |
| Self-Diagnosis | Displays error codes (e.g., FL for full tank) |
| Water Drainage | Manual or continuous (hose required) |
| Exhaust Hose Length | Approx. 1.5 m (extendable) |
| Window Slider Kit | Included (adjustable for vertical/horizontal windows) |
| Castors | Yes (4 wheels for mobility) |
| Air Filter | Washable (clean monthly) |
| Power Supply | 220-240 V ~ 50 Hz (single circuit outlet) |
| Safety Features | R290 flammability warnings, child supervision, auto shut-off if full tank |
| Dimensions (Approx.) | 45 x 45 x 75 cm (height with castors) |
| Weight (Approx.) | 25 kg |
Frequently Asked Questions - AN-PAC07C2 Aconatic
User questions about AN-PAC07C2 Aconatic
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Air conditioner in PDF format for free! Find your manual AN-PAC07C2 - Aconatic and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AN-PAC07C2 by Aconatic.
USER MANUAL AN-PAC07C2 Aconatic
natural_image
Line drawing of a rectangular industrial machine with ventilation grilles and wheels (no text or symbols)natural_image
Line drawing of a rectangular industrial machine with ventilation grilles and wheels (no text or symbols)Thank you for selecting our quality appliance. Please be sure to read this user manual carefully before using. Any question, please contact the professional service for help
- The appliance must be stored in such a way as to prevent mechanical failure.
- Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued by an accredited organization that ensures competence in handling refrigerants according to a specific evaluation recognized by associations in the industry
•Repairs must be performed based on the recommendation from the manufacturing company. Maintenance and repairs that require the assistance of other qualified personnel must be performed under the supervision of an individual specified in the use of flammable refrigerants
- Ducts connected to an appliance shall not contain a potential ignition source.
- Pipes connected to appliances must not have sources of ignition.
- Duct work must be protected from physical damage and in case of flammable refrigerant must not be installed in an unventilated area. If the area is less than 8m^2
- Must comply with national regulations on gas.
- Pipe connections must be accessible for maintenance.
- This appliance is not intended for use by persons (including children) with reduced physical abilities.
sensory or mental, or lack of experience and knowledge, unless supervision or instruction on the use of electrical appliances is given by persons responsible for their safety, children should be supervised to ensure that he will not play with blue appliances
- If the power supply cable is damaged. It must be replaced by the manufacturer or service representative or similarly qualified person to avoid a hazard.
- Air conditioners must be installed in accordance with the electrical installation standards for Thailand of the Engineering Institute of Thailand. under the Royal Patronage (EIT)
- Disconnect the appliance from the power supply during servicing and replacement.
- This portable air conditioner is for household use. It must always be placed in a dry and stable place. Check the wires, when plug or The alternating current socket is damaged, please refrain from using
- The unit must not be placed in a high heat area and avoid direct sunlight in case of moving, or clean the machine must be turned off before every time Assembly or disassembly before cleaning, always unplug the power cord.
General Safety Instruction
-
Children should be supervised to ensure that they do not play with the appliance.
-
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
-
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
-
The appliance shall be installed in accordance with national wiring regulations.
-
Recycling

This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
-
Contact authorized service technician for repair or maintenance of this unit.
-
Do not pull, deform or modify the power supply cord, or immerse it in water. Pulling or misuse of the power supply cord can result in damage to the unit and cause electrical shock.
-
Compliance with national gas regulations shall be observed.
-
Keep ventilation openings clear of obstruction.
-
Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry
recognized assessment specification.
- Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
- Do not operate or stop the unit by inserting or pulling out Die power plug, it may cause electric shock or fire due to heat generation.
- Unplug the unit if strange sounds, smell, or smoke comes from it.
Symbol

Warning; Flammable material
Read operator's manual
Operator's manual; operating instructions

Service indicator; read technical manual
warning
- Do not use methods to speed up the defrostling or cleaning process. In addition to those recommended
-Room air conditioners are stored in a room free of continuous ignition sources (e.g. open flames, gas-operated equipment, etc.). or electrically operated equipment that is in operation) - Not to be pierced or burned
- Beware of refrigerants that may not have an odor.
INSTRUCTIONS FOR REPAIRING APPLIANCES CONTAINING R290
1.1 Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system,
สัญลักษณ์

the following precautions shall be complied with prior to conducting work on the system.
1.2 Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapour being present while the work is being performed.
1.3 General work area
All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
1.4 Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak tection equipment being used is suitable for use with flammable refrigerants, i.e. nonspeaking, adequately sealed or intrinsically safe.
1.5 Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO 2 fire extinguisher adjacent to the charging area.
1.6 No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. "No Smoking" signs shall be displayed.
1.7 Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
1.8 Checks to the refrigeration equipment
Where electrical components are being changed, they shall be lit for the purpose and to the correct specification. At all times the manufacturer's maintenance and service guidelines shall be followed. If in doubt consult the manufacturer's technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: the charge size is in accordance with the room size within which the refrigerant containing parts are installed; the ventilation machinery and outlets are operating adequately and are not obstructed; if an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected; refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.
1.9 Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include: that capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking; that there no live electrical components and wiring are exposed while charging, recovering or purging the system; that there is continuity of earth bonding.
2 REPAIRS TO SEALED COMPONENTS
2.1 During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
2.2 Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected.
This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc. Ensure that
1.9 Surremergional 2016
apparatus is mounted securely. Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer's specifications.
NOTE The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.
3 REPAIR TO INTRINSICALLY SAFE COMPONENTS
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use.
Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.
4 CABLING
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
5 DETECTION OF FLAMMABLE REFRIGERANTS
Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.
6 LEAK DETECTION METHODS
The following leak detection methods are deemed acceptable for systems containing
flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need recalibration. (Detection equipment shall be
calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a
percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and
the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by
means of shut off valves) in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.
7 REMOVAL AND EVACUATION
When breaking into the refrigerant circuit to make repairs – or for any other purpose – con-
ventional procedures shall be used. However, it is important that best practice is followed
since flammability is a consideration. The following procedure shall be adhered to: remove refrigerant; purge the circuit with inert gas; evacuate; purge again with inert gas; open the circuit by cutting or brazing. The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be "flushed" with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipework are to take place. Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is
ventilation available.
8 CHARGING PROCEDURES
In addition to conventional charging procedures, the following requirements shall be followed.
- Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them.
- Cylinders shall be kept upright.
- Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
- Label the system when charging is complete (if not already).
- ทางต่อสายดิลเบ็ด
- Extreme care shall be taken not to overfill the refrigeration system.
Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.
9 DECOMMISSIONING
Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.
a) Become familiar with the equipment and its operation.
b) Isolate system electrically.
c) Before attempting the procedure ensure that mechanical handling equipment is available, if required, for handling refrigerant cylinders; all personal protective equipment is available and being used correctly; the recovery process is supervised at all times by a competent person; recovery equipment and cylinders conform to the appropriate standards.
d) Pump down refrigerant system, if possible.
e) If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
f) Make sure that cylinder is situated on the scales before recovery takes place.
g) Start the recovery machine and operate in accordance with manufacturer's instructions.
h) Do not overfill cylinders. (No more than 80 % volume liquid charge).
i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
j) When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
| 10 LABELLING |
| Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant. |
| 11 RECOVERY |
| When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. |
| The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition,a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintainedand that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer II in doubt. |
| The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. |
| If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely. |
| 1. Control panel | 17. Air outlet grille |
| 12. Remote control receiver | 18. Intake grille |
| 13. Deflector | 19. Plug fixer |
| 14. Handle (both sides) | 20. Condenser drain |
| 15. Castors | 21. Power cable |
| 16. Intake grille |
ACCESSORIES
| PARTS | PARTS NAME | QUANTITY |
![]() | Hose inletExhaust hoseHose outlet | 1 set |
![]() | Window slider kit | 1 set |
![]() | Remote controlBattery | 1 set |
Note: All the illustrations in this manual are for explanatory purposes only. Your appliance may be slightly different.
Be sure all accessories are removed from the packing before use.
Installation Instructions
EXHAUSTING HOT AIR
When use the appliance in cool mode, the hot air exchange of the condenser must be exhausted out of the room completely.
First position unit on a flat floor and make sure there's a minimum of 18°(45cm) clearance around the unit, and is within the vicinity of a single circuit outlet power source.
- Extend either side of the hose (Fig.1), and screw the hose inlet (Fig.2).
- Extend the other side of the hose and screw it to the hose outlet (Fig.3).
- Install the hose inlet into the unit (Fig.4).
- Affix the hose outlet into the window slider kit and seal. (Fig.5 &6).




The window slider kit has been designed to fit most standard vertical and horizontal window applications, however, it may be necessary for you to modify some aspects of the installation procedures for certain types of windows. The window slider kit can be fastened with screws.
NOTE: If the window opening is less than the minimum length of the window slider kit, cut the end without the hold in it short enough to fit in the window opening. Never cut out the hole in window slider kit.

- Cut on opposite side of hole.
WINDOW SLIDER KIT INSTALLATION
1:Parts:
A) Panel
B) Panel with one hole
D) Screw to lock window kit in place

2: Assembly:
Slide Panel B into Panel A and size to widow width. Windows sizes vary. With the width that your window requires to ensure that there are no gaps or air pockets in the window kit assembly after installation.
3. Lock the screw into the holes that correspond
LOCATION
- The unit should be placed on a firm foundation to minimize noise and vibration. For safe and secure positioning place the unit on a smooth, level floor strong enough to support the unit.
- The unit has casters to aid placement, but it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpeted surfaces. Use caution and protect floors when rolling over wood floors. Do not attempt to roll the unit over objects.
- The unit must be placed within reach of a properly rated grounded socket.
- Never place any obstacles around the air inlet or outlet of the unit.
- Allow at least 18"(45cm) of around and above space away from the wall for efficient working.
- The hose can be extended, but it is the best to keep the length to minimum required. Also make sure that the hose does not have any sharp bends or sags.
อุปกรณ์เสริม
![]() | ![]() | ![]() |
TURNING THE APPLIANCE ON/OFF
- Plug into the mains socket, then the appliance is standby.
- Press the Button to make the appliance turn on. The last function active when it was turned off will appear.
- When press the "💡" button to shut down the appliance, the anti-mold function will running about 20 seconds and screen show the count down.



Never turn the air conditioner off by unplugging from the mains. Always press the button then wait for a few minutes before unplugging. This allows the appliance to perform a cycle of checks to verify operation.
COOL mode
Ideal for hot muggy weather when you need to cooling and dehumidify the room.
To set this mode correctly:
—Press the “☐” button a number of times until the “Cool” symbol light appears. —Select the target temperature18°C:32°C(64°F-90°F) by pressing the * √ */ * ∧ * button until the corresponding value is displayed.
Select the required fan speed by pressing the “♣” button. Different fan speed have different function.
F2 High To achieved the temperature as fast as possible.
F1 Low Run of the low noise.
The most suitable temperature for the room during the summer varies from 24°C to 27°C. You are recommended, however, not to set a temperature much below the outdoor temperature. This will cause unnecessary power consumption.
FAN made
When using the appliance in this mode, the air hose does not need to be attached.
To set this mode correctly:
Press the "☐" button a number of times until the "Fan" symbol appears.
—Select the required fan speed by pressing the “♣” button.
Two speeds are available: High(F2)/Low(F1)
Ideal to reduce room humidity (spring and autumn, damp rooms rainy periods, etc).
Before using the dry mode, the appliance should be prepared in the same way as for cool mode with the air exhaust hose attached to enable the moisture to be discharged outside.
To set this mode correctly:
Press the "button a number of times until the
"Dry" symbol light appears, the screen will appear"dh
— In this mode, fan speed is selected automatically by the appliance.
SETTING THE TIMER
This timer can be used to delay the appliance start up or shutdown, this avoids wasting electricity by optimizing operating periods.
* Programming start-up
- Turn on the appliance, choose the mode you want, for example Dehumidify mode, high fan speed. Turn off the appliance.
- Press the " ℓ" button, the screen starts to flash. press the ' √ "/ * ∧ * to adjust the set time from 0.5-24 hours.
- In 5 seconds without the operation, the timer start function, then the "Timer" symbol lights.
- Press the "button again to cancel the Timer, and the "Timer" symbol disappear.
^ Programming shut down
- When the appliance is running, press the "L" button, the screen starts to flash. Press the "√/”^ to adjust the set time from 0.5-24 hours.
- In 5 seconds without the operation, the timer start function, then the "Timer" symbol lights.
- Press the "Button again to cancel the Timer, and the "Timer" symbol disappear.


Switch the unit of temperature
When the appliance is running, hold on " √ " and " ∧ " button together 3 seconds by the same time, then you can change the unit of temperature.
For example:
Before change, in cool mode, the screen display like fig1.
After change, in cool mode, the screen display like fig2.

Fig.1

Fig.2
SELF-DIAGNOSIS
The appliance has a self diagnosis system to identify a number of malfunctions.
Error messages are displayed on the appliance display.
| IF IS DISPLAYED | WHAT SHOULD I DO? |
| If this is displayed, contact your local authorize service centre. | |
| PROBE FAILURE (sensor damaged) | |
| Empty the internal safety tank, following the instructions in the "End of season operations" paragraph. | |
| FULL TANK (safety tank full) |
การเปิด/ปิดเครื่อง
NOTE: This serial model have no auto swing function.
√ Point the remote control at the receiver on the appliance.
√ The remote control must be no more than 7 meters away from the appliance (without obstacles between the remote control and the receiver).
√ The remote control must be handled with extreme care. Do not drop it or expose it to direct sunlight or sources of heat. If the remote control do not work, please try to take out the batter and put it back again.

INSERTING OR REPLACING THE BATTERIES
- Remove the cover on the rear of the remote control;
- Insert two "AAA" 1.5V batteries in the correct position (see instructions inside the battery compartment;

NOTE:
√ If the remote control unit is replaced or disposed of, the batteries must be removed and discarded in accordance with current legislation as they are harmful to the environment.
Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc) or rechargeable (nickel-cadmium) batteries.
√ Do not dispose of batteries in fire. Batteries may explode or leak.
√ If the remote control is not be used for a certain length of time, remove the batteries
โหมดพัดลม (FAN)
TURNING THE APPLIANCE ON/OFF
- Plug into the mains socket, then the appliance is standby.
- Press the button to make the appliance turn on. The last function active when it was
turned off will appear.
- When press the "💡" button to shut down the appliance, the anti-mold function will running about 20 seconds and screen show the count down.
COOL mode
Ideal for hot muggy weather when you need to cooling and
ehumidify the room.
o set this mode correctly:

-Press the "☐" button a number of times until the "Cool" symbol light appears.
Select the target temperature18°C-32°C(64°F-90°F) by pressing the “Λ” or “v” button until the corresponding value is displayed.
Select the required fan speed by pressing the “×” button. Different fan speed have different function.
High To achieved the temperature as fast as possible.
Low Run of the low noise.
The most suitable temperature for the room during the summer varies from 24°C to 27°C (75°F to 81°F). You are recommended, however, not to set a temperature much below the outdoor temperature. The fan speed difference is more noticeable when the appliance is under FAN mode but may not be noticeable under COOL mode.
FAN mode
When using the appliance in this mode, the air hose does not need to be attached.
-Press the “☐” button a number of times until the “Fan” symbol light appears.
Select the required fan speed by pressing the “ ✗ ” button.
Two speeds are available: High/Low.
Ideal to reduce room humidity (spring and autumn, damp rooms rainy periods, etc).
In dry mode, the appliance should be prepared in the same way as for cool mode, with the air exhaust hose attached to enable the moisture to be discharged outside.
To set this mode correctly:
Press the “☐” button a number of times until the

"Dry" symbol light appears, the screen will appear "dh";
— In this mode, fan speed is selected automatically by the appliance and default low speed fan.
SWING function
Notes: This serial unit have no auto swing function
SLEEP function
This function is useful for the night as it gradually reduces operation of the appliance.
To set this function correctly:
—Select the cool mode as described above.
Press the “” button.
The appliance operates in the previously selected mode.
When you choose the sleep function, the screen will reduce the brightness and the fan speed is low.
The SLEEP function maintains the room at optimum temperature without excessive
fluctuations in either temperature or humidity with silent operation. Fan speed is always at Low, while room temperature and humidity vary gradually to ensure the most comfortable.
When in COOL mode, the selected temperature will increase by 1^(J^1) per hour in a 2 hour period. This new temperature will be maintained for the next 6 hours. Then the appliance turn it off.
The SLEEP function can be canceled at any time during operation by pressing the "Sleep", "Mode" or "fan speed" button.
In DRY mode, SLEEP function is still available.
วิทยาลัยนิตร
-This timer can be used to delay the appliance startup or shutdown, this avoids wasting electricity by optimising operating periods.
* Programming start-up
- Turn on the appliance, choose the mode you want, for example Dehumidity mode, high fan speed. Turn off the appliance.
- Press the " button, the screen starts to flash, press the "A" or "v" to adjust the set time from 0.5-24 hours.
- In 5 seconds without the operation, the timer start function, then the "Timer" symbol lights.
- Press the * button button again to cancel the Timer, and the "Timer" symbol disappear.
* Programming shut down
- When the appliance is running, press the * 📁 " button, the screen starts to flash,press the " ∧ "/" ∨ " to adjust the set time from 0.5-24 hours.
- In 5 seconds without the operation, the timer start function, then the "Timer" symbol lights.
- Press the "button again to cancel the Timer, and the "Timer" symbol disappear.
Switch the unit of temperature
When the appliance is running, press the "Cbo"ron, then you can change the unit of temperature.
For example:
Before change, in cool mode, the screen display like fig1.
After change, in cool mode, the screen display like fig2.

Fig.1

Fig.2
Low Total reward of the following business
quangjhiqianzamhuiqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunqunq
To get the best from your appliance, follow these recommendations:
- Close the windows and doors in the room to be air conditioned (fig. 21). When installing the appliance semi-permanently, you should leave a door slightly open (as little as 1 cm) to guarantee correct ventilation;
- Protect the room from direct exposure to the sun by partially closing curtains and/or blinds to make the appliance much more economical to run (fig. 22);
- Never rest objects of any kind on the appliance;
- Do not block the air inlet or outlet of the appliance. Reduced air flow will result in poor performance and could damage the unit (fig. 23).
• Make sure there are no heat sources in the room; - Never use the appliance in very damp rooms (laundries for example).
- Never use the appliance outdoors.
- Make sure the appliance is standing on a level surface. If necessary, place the castor locks under the front wheels.



WATER DRAINAGE METHOD
When there is excess water condensation inside the unit, the appliance stops running and shows "FL" (FULL TANK as mentioned in SELF-DIAGNOSE). This indicates that the water condensation needs to be drained using the following procedures:
Manual Draining (fig.24)
- Unplug the unit from power source.
- Place a pan(not supply) under the lower drain plug. See diagram.
- Remove the lower drain plug.
- Water will drain out and collect in the pan.
- After the water is drained, replace the lower drain plug firmly.
6.Turn on the unit.
Continuous Draining (fig.25)
-
Unplug the unit from the power source.
-
Remove the drain plug. While doing this operation some residual water may spill so please
have a pan (not supply) to collect the water.
-
Connect the drain hose (1/2" or 12.7mm, maybe not supplied). See diagram.
-
The water can be continuously drained through the hose into a floor drain or bucket.
-
Turn on the unit.


NOTE
Please be sure that the height of and section of the drain hose should not be higher than that of the drain outlet, or the water tank may not be drained. (fig.26 and fig.27)


CLEANING
Before cleaning or maintenance, turn the appliance off by pressing the ⏻ button on the control panel or remote control, wait for a few minutes then unplug from the mains socket.
CLEANING THE CABINET
You should clean the appliance with a slightly damp cloth then dry with a dry cloth, may not use water to wash appliance.
■ Never wash the appliance with water. It could be dangerous.
- Never use petrol, alcohol or solvents to clean the appliance.
- Never spray insecticide liquids or similar.
CLEANING THE AIR FILTERS
To keep your appliance working efficiently, you should clean the filter every month of operation.
The evaporator filter can take out like fig.

● To avoid possible cuts, avoid contacting the metal parts of the appliance when removing or re-installing the filter. It can result in the risk of personal injury.
Use a vacuum cleaner to remove dust accumulations from the filter. If it is very dirty, immerse in warm water and rinse a number of times. The water should never be hotter than 40°C(104°F). After washing, leave the filter to dry then attach the intake grille to the appliance.
START-END OF SEASON OPERATIONS
START OF SEASON CHECKS
Make sure the power cable and plug are undamaged and the earth system is efficient. Follow the installation instructions precisely.
END OF SEASON OPERATIONS
To empty the internal circuit completely of water, remove the cap(fig. below).
Run off all water left into a basin. When all the water has been drained, put the cap back in place.
Clean the filter and dry thoroughly before putting back.

| PROBLEM | CAUSE | SOLUTION |
| The appliance does not come on | There is no currentIt is not plugged into the mainsThe internal safety device has tripped | WaitPlug into the mainsWait 30 minutes, if the problem persists, contact your service center |
| The appliance works for a short time only | Here are bends in the air exhaust hoseSomething is preventing the air from being discharged | Position the air exhaust hose correctly, keeping it as short and free of curves as possible to avoid bottlenecksCheck and remove any obstacles obstructing air discharge |
| The appliance works, but does not cool the room | Windows, doors and/or curtains open | Close doors, windows and curtains, bearing in mind the "tips for correct use" given above |
| There are heat sources in the room (oven, hairdryer, etc) | Eliminate the heat sources | |
| The air exhaust hose is detached from the appliance | Fit the air exhaust hose in the housing at the back of the appliance | |
| The technical specification of the appliance is not adequate for the room in which it is located |
| During operation, there is an unpleasant smell in the room | • Air filter clogged | •Clean the filter as described above |
![]() | •Wait. This delay is part of normal operation | |
| minutes after restarting it | ||
![]() | ![]() | |
| PF : FE | Chapter | |
PF:FE
Chapter
หมายเหตุ