Product Type 20" Omni Floor Fan
Fan Diameter 20 inches (50.8 cm)
Power Supply 220-240 V ~ 50 Hz
Current Rating 15 A circuit minimum
Plug Type 3-prong grounded plug
Construction Steel guard and housing
Safety Guard Built-in front and rear safety guards (non-removable during operation)
Special Features Omni-directional airflow; designed for floor use; not wall-mountable
Certifications CE, STXE-400
Warranty Refer to manufacturer; typical 1 year
Weight Approximately 12 kg (26.5 lbs)
Dimensions (Overall Height) Approximately 50 inches (127 cm) on stand
Cleaning Instructions Unplug before cleaning; wipe with damp cloth; do not immerse
Operation Limits Indoor use only; not for hazardous locations; do not use with solid-state speed controls
Included Accessories User manual; no additional parts (stand-alone unit)

Frequently Asked Questions - ST-20FO-DDF-E STANLEY

How do I assemble the ST-20FO-DDF-E fan?
The fan comes pre-assembled. Simply place it on a level surface, adjust the tilt if needed, and plug into a grounded outlet. No tools required.
What voltage and frequency does this fan require?
It requires 220-240 V at 50 Hz with a minimum 15 A circuit. Use only with a grounded outlet.
Can I use an extension cord with this fan?
Yes, but use only a UL-listed extension cord of proper amp rating (at least 15 A) and with a receptacle for the 3-prong grounded plug. Keep cords away from heat, oil, and sharp edges.
Is the fan suitable for outdoor or wet locations?
No. This fan is for indoor use only. Do not expose to water or rain to reduce the risk of electric shock.
Does the fan oscillate?
This model is an Omni Floor Fan which provides multidirectional airflow but does not have a mechanical oscillation feature. You can manually adjust the tilt.
How do I clean the fan?
Always unplug the fan before cleaning. Wipe the exterior with a damp cloth. Do not use abrasive cleaners or immerse the fan in water. The guards can be wiped gently.
What should I do if the power cord is damaged?
Do not operate the fan with a damaged cord. Discard the fan or return it to an authorized service facility for examination and repair. Do not attempt to repair the cord yourself.
Can I mount this fan on a wall?
No. The ST-20FO-DDF-E is designed for floor use only and cannot be wall-mounted. Attempting to do so may cause instability.
What safety features does this fan have?
The fan includes a 3-prong grounded plug, safety guards to prevent contact with blades, and a thermal overload protector (if applicable). Always unplug before servicing.
Can I use a solid-state speed control with this fan?
No. To reduce the risk of fire or electric shock, do not use with any solid-state speed control device. Only use the fan as intended.

User questions about ST-20FO-DDF-E STANLEY

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Fan in PDF format for free! Find your manual ST-20FO-DDF-E - STANLEY and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ST-20FO-DDF-E by STANLEY.

USER MANUAL ST-20FO-DDF-E STANLEY

User's Manual and Operating Instructions

Model Numbers: ST-12F-DDF-E, ST-20F-DDF-E, ST-20FO-DDF-E, ST-24-DDF-E, ST-42-BDF-E, ST-36-DDF-E, ST-30P-DDF-E

12" Floor Fan

ST-12F-DDF-E

STANLEY ST-20FO-DDF-E - 12" Floor Fan - 1

42" Belt-Drive Barrel Fan

ST-42-BDF-E

STANLEY ST-20FO-DDF-E - 42" Belt-Drive Barrel Fan - 1

24" Floor Fan

ST-24-DDF-E

STANLEY ST-20FO-DDF-E - 24" Floor Fan - 1

natural_image Front view of a large industrial fan with visible blades and mounting base (no text or symbols)

20" Floor Fan

ST-20F-DDF-E

STANLEY ST-20FO-DDF-E - 20" Floor Fan - 1

natural_image Front view of a large industrial fan with visible blades and blades, mounted on a stand (no text or symbols)

20" Omni Floor Fan

ST-20FO-DDF-E

STANLEY ST-20FO-DDF-E - 20" Omni Floor Fan - 1

30" Pedestal Fan

ST-30P-DDF-E

STANLEY ST-20FO-DDF-E - 30" Pedestal Fan - 1

natural_image Front view of a four-blade desktop fan with visible blades and mounting base (no text or symbols)

36" Direct-Drive Barrel Fan

ST-36-DDF-E

STANLEY ST-20FO-DDF-E - 36" Direct-Drive Barrel Fan - 1

natural_image Circular mechanical fan with radial blades and a handle, no visible text or symbols

READ AND SAVE THESE INSTRUCTIONS

IMPORTANT: Read and understand all of the instructions in this manual before assembling, starting, or servicing the fan. Improper use of this fan can cause serious injury. Keep this manual for future reference.

CE

STANLEY ST-20FO-DDF-E - READ AND SAVE THESE INSTRUCTIONS - 1

STXE-400

Please note the serial number of your fan, and write it on the back of this User's Manual for future reference.

© 2018, Obelis S.A Registered Address: Bd. Général Wahis, 53 1030 Brussels, Belgium

Safety Information

IMPORTANT: READ ALL INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY, SERVICE OR USE OF THIS FAN. FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN SERIOUS PERSONAL INJURY AND / OR PROPERTY DAMAGE.

⚠️ CAUTION For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors. Never use the fan in spaces which contain products such as gasoline, solvents, paint thinners, dust particles, volatile or airborne combustibles, or any unknown chemicals.

⚠ WARNING Do not operate any fan with a damaged cord or plug.

Discard fan or return to an authorized service facility for examination and/or repair.

Do not run under carpeting.

Do not cover with throw rugs, runners, or similar coverings.

Do not route cord under furniture or appliances.

Arrange cord away from traffic area where it will not be tripped over.

To reduce the risk of electric shock, do not expose to water/rain or use in damp locations.

▲CAUTION To reduce risk of fire and to properly exhaust air, be sure to duct air outside.

Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.

▲WARNING THIS IS A FAN - NOT A TOY! TO REDUCE THE RISK OF PERSONAL INJURY AND ELECTRIC SHOCK, FANS SHOULD NOT BE PLAYED WITH OR PLACED WHERE SMALL CHILDREN CAN REACH IT.

⚠ WARNING To guard against electric shock while operating, do not allow fan to come in contact with other grounded objects such as pipes, radiators, etc.

▲WARNING Risk of fire, electric shock, or personal injury when performing service or maintenance. Unplug or disconnect the fan from the power supply before servicing.

WARNING CAUTION Automatically Operated Device - To Reduce The Risk Of Injury Disconnect From Power Source Before Servicing

⚠ WARNING To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.

⚠ WARNING To Reduce The Risk Of Electric Shock And Injury To Persons, Do Not Use In a Window.

STANLEY.

STANLEY

STANLEY, The STANLEY Logo, The Notched Rectangle and the Yellow and Black Diagonal Package Design are all trademarks of Stanley Black & Decker, Inc. or an affiliate thereof.

STANLEY®

NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE

Safety Information

To Reduce The Risk Of Electric Shock, Do Not Expose To Water Or Rain or use in damp locations.
Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair. Do not run cord under car-cover cord with throw rugs, runner, or similar coverings. Do not route cord under fur-nces. Arrange cord away from traffic areas and where it will not be tripped over.
Installation work and electrical wiring must be done by qualified person (s) in accordance with all applicable codes and regulations.
When servicing or replacing a component requires the removal or disconnection of a safety device, the safety device is to be reinstalled or remounted as previously operating this fan.
Use this fan only in the manner intended by the manufacturer.
- Before operating always check fan for loose or damaged parts. Inspect power cord for any damage. Never use fan if any parts are damaged or missing. Never use fan without safety guards attached.
- Operate only on 220-240 volt, 50 Hz (cycle) current with a minimum of a 15 amp circuit.
- When used with an extension cord, use only cord of proper size (Amp rating), UL listed, and with receptacle to accept three prong grounded plug furnished on the fan's power cord. Always keep power cord and extension cords away from heat, oil, and sharp edges. Inspect cords periodically and replace if damaged.

WARNING

WARNING

WARNING

WARNING

WARNING

Installation and Assembly

ST-12F-DDF-E / ST-20F-DDF-E / ST-20FO-DDF-E / ST-24-DDF-E

  1. Place the fan on level ground in a safe, desired position then connect to an approved power source.

ST-36-DDF-E / ST-42-BDF-E

  1. Slide wheel axle through wheel support frame.
  2. Slide one (1) wheel onto either side of axle.
  3. Secure wheel with one (1) cotter pin.
  4. Place the fan on level ground in a safe, desired position then connect to an approved power source.

30" PEDESTAL FAN: ST-30P-DDF-E

Installation and Assembly

Tools Needed:

Pliers

Phillips head screwdriver

10mm spanner or adjustable wrench

Hex Wrench

Parts Included In Box:

(1) Base
(1) Front Guard
(1) Rear Guard
(1) Motor Assembly
(1) Fan Blade Assembly
(1) Locking Collar
(1) Upper Support Pole
(1) Lower Support Pole
(1) Nut (M12) and Washer
(1) Pivot Bolt (M12*40)
(9) Flange Screws
(1) Support Spring

Motor Assembly Nut Pivot Bolt Upper Support Pole

Figure 1: Attaching Motor to Motor Support Assembly

Rear Guard Motor

Figure 2: Attaching Rear Guard to Motor

  1. Place the Base on level ground
  2. Place the Support Spring and Spring Seat inside the bottom of the Support Pole, and mount the Support Pole to the Base. Make sure the holes line up.
  3. Secure tightly with (5) Flange Screws using the wrench/Phillips head screwdriver.

  4. Put down the base cover.

  5. Loosen the locking collar screw using the adjustable handle. Extract the Upper Support Pole slowly to adjust the height of the fan. Retighten with the adjustable handle.

  6. Loosen the set screw on the motor support. Mount the Motor Assembly to the connector on the Upper Support Pole. Make sure the holes line up.

  7. Secure Motor Assembly with Pivot Bolt (M12*40), Nut (M12), and Washer (see Fig. 1). Tighten the bolt firmly using the wrench. Tighten the set screw.

  8. Slide the Rear Guard on to Motor Assembly and secure it with (4) Flange Screws (see Fig. 2). Tighten the screws firmly using the wrench/Phillips head screwdriver.

  9. Loosen the screw on the back of the Fan Blade Assembly using the Allen wrench (hex wrench). Slide the Fan Blade Assembly onto the motor shaft. Retighten the screw on the Fan Blade Assembly.

  10. Attach the Front Guard to the Back Guard and secure with the fasteners on the front guard.

▲ CAUTION

Do NOT slide fan blade screw beyond the groove on the shaft!

This will cause the fan blade to not spin properly and can cause damage to your fan! Be sure that fan shaft is flush with front of fan blade assembly.

NOTE: This model CAN NOT be wall mounted

STANLEY®

Pinnacle Climate Technologies, Inc.

Sauk Rapids, MN 56379 USA

EC REP

Obelis S.A.

Registered Address:

1030 Brussels, Belgium

© 2018 Stanley Black & Decker, Inc.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : STANLEY

Model : ST-20FO-DDF-E

Category : Fan