Product Type Portable Air Conditioner
Cooling Capacity 12,000 BTU/h
Power Supply 230 V / 50 Hz
Power Consumption (Cooling) 1200 W
Refrigerant R-32
Air Flow Rate 400 m³/h
Noise Level (Low/High) 52 / 60 dB(A)
Operating Modes Cool, Fan, Dehumidify
Thermostat Range 16°C – 30°C
Timer 1 – 24 hours
Remote Control Yes
Dimensions (W x H x D) 350 x 700 x 350 mm
Weight 28 kg
Condensate Drain Continuous or manual
Filter Type Washable mesh
Certifications CE, RoHS

Frequently Asked Questions - SuperCooler VII Thermex

How often should I clean the filter?
Clean the filter every two weeks during heavy use. A dirty filter reduces efficiency. Remove, wash with mild detergent, dry, and reinstall.
Can I use the air conditioner without installing the exhaust hose?
No, the exhaust hose must be vented outside to expel hot air. Operating without it will cause the unit to overheat and reduce cooling.
What is the recommended room size?
The SuperCooler VII is suitable for rooms up to 35 m² (about 380 sq ft) with standard ceiling height.
Does the unit have a dehumidifier mode?
Yes, the unit includes a dehumidifier mode that removes excess moisture from the air. In this mode, the fan runs, and the compressor operates intermittently.
How to reset the error code?
Turn off the unit and unplug it for 5 minutes. Plug back in and restart. If the error persists, consult the manual or contact Thermex support.
Can the timer be set for both on and off?
Yes, the timer can be programmed to turn the unit on or off after a set period (1 to 24 hours). Use the remote control to adjust.
What does the 'E4' error code mean?
Error code E4 indicates a sensor failure. Check if the air intake or exhaust is blocked. If not, contact service.
Is the remote control included?
Yes, a remote control is included with the unit. Batteries (2 x AAA) are not supplied.
How does the unit defrost?
In heating mode (if applicable), the unit automatically defrosts by reversing the cycle. The fan stops during defrost and resumes after.
What is the noise level?
The noise level varies from 52 dB(A) on low fan speed to 60 dB(A) on high fan speed, measured at 1 meter distance.

User questions about SuperCooler VII Thermex

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air-conditioner in PDF format for free! Find your manual SuperCooler VII - Thermex and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SuperCooler VII by Thermex.

USER MANUAL SuperCooler VII Thermex

natural_image Line drawing of a portable air conditioner unit with a blue arrow indicating airflow direction (no text or symbols)
natural_image Diagram showing two air purifiers with heat exchangers, one emitting heat from a fan-shaped cover (no text or symbols)

Køling

Thermex SuperCooler VII - 1

natural_image Diagram showing two air purifiers with heat sinks, each with a blue arrow indicating airflow direction (no text or symbols present)

Opvarmning

K∅LING

natural_image Line drawing of a portable air purifier connected to a bowl with a connecting tube (no text or symbols)
natural_image Line drawing of a portable air purifier connected to a bowl with a tube (no text or symbols)
natural_image Line drawing of a portable air purifier with a bowl nearby (no text or symbols)
natural_image Diagram of a portable air conditioner unit with cooling fins and a bowl of food (no text or symbols)
natural_image Technical diagram of a mechanical device with heat exchangers and directional arrows indicating flow (no text or symbols)
natural_image Line drawing of an air conditioner unit with a blue arrow indicating airflow direction (no text or symbols)
natural_image Diagram showing two air purifiers with heat exchangers, connected by directional arrows indicating airflow or ventilation (no text or symbols present)

Kjøling

Thermex SuperCooler VII - K∅LING - 1

natural_image Diagram showing two air purifiers with heat sinks and airflow direction arrows (no text or symbols)

Oppvarming

K∅LING

natural_image Line drawing of a portable air purifier connected to a bowl via a tube (no text or symbols)
natural_image Line drawing of a portable air purifier connected to a bowl with a tube (no text or symbols)
natural_image Line drawing of a portable air purifier with a bowl nearby (no text or symbols)
natural_image Diagram of a portable air conditioner unit with cooling fins and a bowl of liquid (no text or symbols)
natural_image Technical line drawing of a mechanical device with heat exchangers and wheels, showing directional arrows (no text or symbols)
natural_image Line drawing of an air conditioner unit with a blue arrow indicating airflow direction (no text or symbols)
natural_image Diagram showing two air purifiers with heat exchangers, one emitting heat from a fan-shaped cover (no text or symbols)

Thermex SuperCooler VII - K∅LING - 1

natural_image Diagram showing two air purifiers with heat exchangers, one emitting heat from a fan-shaped component (no text or symbols)

Kylning
Uppvärmning

KYLNING

natural_image Line drawing of a portable air purifier connected to a bowl via a tube (no text or symbols)
natural_image Line drawing of a portable air purifier connected to a bowl with a tube (no text or symbols)
natural_image Line drawing of a portable air purifier with a bowl nearby (no text or symbols)
natural_image Diagram of a multi-tiered air purifier with cooling fans and a bowl below (no text or symbols)
natural_image Technical diagram of a mechanical device with heat exchangers and directional arrows indicating flow (no text or symbols)
natural_image Line drawing of a portable air conditioner unit with a coiled tube being inserted (no text or symbols)

Jäähdytys

Thermex SuperCooler VII - KYLNING - 1

natural_image Diagram showing two air purifiers with blue arrows indicating airflow or movement, no text or symbols present.

Lämmitys

JÄÄHDYTYS

natural_image Line drawing of a portable air purifier connected to a bowl via a tube (no text or symbols)
natural_image Line drawing of a portable air purifier connected to a bowl with a tube (no text or symbols)
natural_image Line drawing of a portable air purifier with a bowl nearby (no text or symbols)
natural_image Line drawing of a portable air conditioner unit with cooling fins and a bowl of liquid (no text or symbols)
natural_image Technical line drawing of a mechanical device with heat exchangers and wheels, showing directional arrows (no text or symbols)
Warnings45
Included in the box46
The Product46
Use of the product48
Maintenance and cleaning52
Service53
Environmental considerations53

WARNINGS

• The product is designed and manufactured according to DS/EN 60335-1.
- This product is only for use in private householdings, if used for other purposes the warranty will be repealed.
- Installation must be performed by a skilled electrician in accordance with the specifications given by Thermex Scandinavia A/S (Thermex) and legislation in force.
- Thermex disclaims all responsibility with regards to damages caused by wrong installation, mounting or use.

BEFORE MOUNTING/COMMISSIONING

  • Inspect the product for transport damages, flaws and defects immediately after the receipt.
  • Transport damages must be filed to the haulage contractor and Thermex immediately after the receipt.
  • Flaws and defects must be filed to Thermex within 8 days after the receipt, and not later than mounting/commissioning.

INSTALLATION

  • The product is designed to operate at 230 volts ± 10% \~ 50 Hz ± 15% according to EN 50160.
  • Connect SuperCooler VII to the power supply with the supplied Schuko plug.
  • SuperCooler VII must be earthed ().

OPERATION

• Always read these instructions carefully BEFORE using the Super-Cooler VII.
• Always keep this manual for future reference.

  • It is recommended that you wait at least four hours before connecting SuperCooler VII after a period in transit or storage. This is so the oil has time to run back into the compressor.
    • Air intake and exhaust must NEVER be blocked.
  • Only use SuperCooler VII when it is in upright position.
  • NEVER use SuperCooler VII if the temperature exceeds 35°C.
    • Always disconnect power to the SuperCooler VII prior to maintenance or repair.
  • Do not repair or replace any part of the product, unless specifically recommended in the user manual.
  • All repairs must be performed by a qualified technician.
  • SuperCooler VII may only be used by children under 8 years of age, people with physical, mental or sensory disabilities and persons who lack experience or knowledge if these persons are supervised or have received the necessary training in the safe use of the SuperCooler VII.
    • Children should be supervised so that they do not play with the SuperCooler VII.
  • Cleaning and maintenance may only be performed by children under supervision.
    • Always wait a minimum of 3 minutes after turning the product off before restarting it.
  • In order to achieve the best possible use from your SuperCooler VII, Thermex recommends that the ventilation hose does not exceed 1 metre and is not bent or twisted.
  • Ensure that there is good ventilation around the filters on the SuperCooler. Thermex recommends that there is a minimum 0.5 metres from the side of the filter on SuperCooler VII to the nearest wall or similar.

INCLUDED IN THE BOX

• 1 SuperCooler VII
- 1 remote control
• 2 AAA batteries for the remote control
• 1 ventilation hose - 1.5 meters

THE PRODUCT

1 2 3 4

5 6 7

  1. Exhaust for mounting of ventilation hose
  2. Cold air intake
  3. Warm air intake
  4. Drain for cooling
  5. Control panel
  6. adjustable exhaust
  7. Drain for heating and dehumidifying

THE CONTROL PANEL
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 POWER TEMP+ SPEEDFUN SLEEPTEMP-

  1. IR receiver
  2. Indicator for cooling
  3. Indicator for heating
  4. Indicator for dehumidifying
  5. Indicator for sleep mode
  6. Function button
  7. Timer button
  8. On/off button
  9. Display
  10. Indicator for speed 3
  11. Indicator for speed 2
  12. Indicator for speed 1
  13. Indicator for automatic speed regulation
  14. Up arrow
  15. Speed button
  16. Sleep button
  17. Down arrow

REMOTE CONTROL
1 2 3 4 5 AUTO HI MID LOW TEMP FUNC TIMER SLEEP POWER 6 7 8 9 10

  1. Up arrow
  2. Automatic speed function
  3. Button for selection of speed 3
  4. Button for selection of speed 2
  5. Button for selection of speed 1
  6. Function button
  7. Timer button
  8. Sleep button
  9. Down arrow
  10. On/off button

USE OF THE PRODUCT

SuperCooler VII can be used for cooling, heating or as a dehumidifier. SuperCooler VII is set to the function one wishes to use. The functions are controlled via the control panel or the enclosed remote control.

SuperCooler VII is turned on and off by pressing the on/off button. The first time SuperCooler VII is switched on after having been disconnected from the power, it will be in cooling mode. If the SuperCooler VII is turned on and off without disconnecting the power, it will be the last selected function that is turned on. SuperCooler VII can be turned off regardless of which function is activated.

When switching between functions, e.g. from dehumidifying to cooling, there will be a changeover period of about three minutes before the selected function starts. This is to protect the compressor in SuperCooler VII. The icon for the selected function will flash during the changeover period and be constant once the function has started.

NOTE: If SuperCooler VII stops during heating or cooling, and the letters DF flashes in the display, it means that SuperCooler VII is in the process of a defrosting cycle. Heating or cooling will start automatically once SuperCooler VII is defrosted.

Before starting up SuperCooler VII, the ventilation hose must be mounted. The exhaust outlet leads excess heat or cold air away from the room where SuperCooler VII is placed.

Thermex SuperCooler VII - USE OF THE PRODUCT - 1

natural_image Line drawing of a portable air conditioner unit with a blue arrow indicating airflow direction (no text or symbols)

Set the ventilation hose on the exhaust by screwing it carefully down into the flange.

Lead the exhaust outlet out of the room, for example through a window.

When using SuperCooler VII for heating or cooling it is important that the exhausts are facing the correct way:

Thermex SuperCooler VII - USE OF THE PRODUCT - 2

natural_image Diagram showing two air purifiers with ventilation grilles, connected by blue arrows indicating airflow or circulation (no text or symbols present)

Cooling

Thermex SuperCooler VII - USE OF THE PRODUCT - 3

natural_image Diagram showing two air purifiers with heat sinks and airflow direction arrows (no text or symbols)

Heating

COOLING

SuperCooler VII can cool as long as the temperature range is between 17 °C and 35 °C. If the air is colder than 17 °C or warmer than 35 °C, SuperCooler VII cannot cool. Ie. If the temperature drops outside the working range, the SuperCooler VII cannot cool.

Switch on SuperCooler VII and press the function button until the icon for cooling is activated. The display shows the temperature that the unit will cool down to. Use the arrow buttons to adjust the temperature. Cooling and the fan will both start immediately once the cooling function has been activated.

When cooling, the speed of the fan can be regulated. The fan has three speeds, which is set by pressing the set speed button until the icon for the desired speed is activated. If you select the automatic speed regulation, the speed on the fan is set in relation to how much the temperature should be lowered in the room.

Once the room has reached the desired temperature, the compressor in SuperCooler VII will stop, thereby stopping the unit from cooling. The fan will continue to run at the selected speed. If the fan is set to automatic speed regulation, the speed of the fan will drop to the lowest speed. The compressor will start up again once the actual temperature exceeds the set temperature.

NOTE: If SuperCooler VII stops cooling and the display shows fault code E4, this means the water tanks need emptying. Follow the guidelines in the section MAINTENANCE AND CLEANING on page 62.

HEATING

SuperCooler VII can heat as long as the temperature range is between 15 °C and 25 °C. If the air is colder than 15 °C or hotter than 25 °C, SuperCooler VII cannot heat. Ie. If the temperature drops outside the working range, the SuperCooler VII cannot heat.

Thermex SuperCooler VII - HEATING - 1

natural_image Line drawing of a portable air purifier connected to a bowl with a tube (no text or symbols)

In order to achieve an optimal heating level it is recommended that a drain hose is mounted to the drain for dehumidifying and heating.

Switch on SuperCooler VII and press the function button until the icon for heating is activated. The display shows the temperature that the unit will heat up to. Use the arrow buttons to adjust the temperature. When heating is activated, the heating function and the fan will start up immediately.

NOTE: The fan will always run at the highest speed when heating and cannot be adjusted.

Once the room has reached the desired temperature, the condenser in SuperCooler VII will stop, thereby stopping the unit from heating and stopping the fan. The condenser and the fan will start up again once the actual temperature goes under the set temperature.

NOTE: If a drain is not installed, the water tank in SuperCooler VII will fill up during heating. If the water tank is full, SuperCooler VII will stop heating and the display will show fault code E4. Follow the guidelines in the section MAINTENANCE AND CLEANING on page 62 for how to empty the tank.

DEHUMIDIFYING

Switch on SuperCooler VII and press the function key until the letters DH are shown in the display and the icon for dehumidifying is activated. Dehumidifying will start the moment the function is activated.

Thermex SuperCooler VII - DEHUMIDIFYING - 1

natural_image Line drawing of a portable air purifier connected to a bowl via a tube (no text or symbols)

In order to achieve an optimal dehumidifying level it is recommended that a drain hose is mounted to the drain for dehumidifying and heating.

NOTE: If a drain is not installed, the water tank in SuperCooler VII will fill up during dehumidifying. If the water tank is full, SuperCooler VII will stop dehumidifying and the display will show fault code E4. Follow the guidelines in the section MAINTENANCE AND CLEANING on page 62 for how to empty the tank.

NOTE: The fan will always run at the lowest speed when dehumidifying and cannot be adjusted.

TIMER FUNCTION

If the timer function is activated, SuperCooler VII will turn on or off after the time period selected. The timer function can be used regardless of whether SuperCooler VII is used for cooling, heating or dehumidifying.

The timer function is set as follows if SuperCooler VII is to turn on automatically after a selected time period:

  • Ensure that SuperCooler VII is switched off completely. Neither the display nor the icons may light.
  • Press on the timer button to activate the timer function.
  • In the display you can see the number of hours until SuperCooler VII will switch on. Use the arrow keys to regulate the number of hours up or down for how long you wish to wait before SuperCooler VII will switch on.
  • Select the function that SuperCooler VII is to switch on to by using the function button.
  • Set the temperature using the arrow keys. (This does not apply if the dehumidifying function has been selected)
  • The timer function is set once the number of hours in the display has stopped flashing.
    • The indicator for the selected function will flash until the set time period has expired, after which SuperCooler VII will start.

If the timer button is pressed while the timer function is activated, the remaining number of hours to go before the SuperCooler VII turns on will be shown. If you wish to deactivate the timer function, press twice on the on/off button.

The timer function is set as follows if SuperCooler VII is to turn off automatically after a selected time period:

  • Set SuperCooler VII to the desired function and temperature, if relevant.
  • Press on the timer button to activate the timer function.
  • In the display you can see the number of hours until SuperCooler VII will turn off. Use the arrow keys to regulate the number of hours up or down for how long you wish to wait before SuperCooler VII will turn off.
  • The timer function is set once the number of hours in the display has stopped flashing.

If the timer button is pressed while the timer function is activated, the remaining number of hours before the SuperCooler VII turns off will be shown. If you wish to deactivate the timer function, press on the timer button until the display shows '0' or turn off SuperCooler VII.

SLEEP MODE

Sleep mode can be used to gradually raise or lower the temperature by up to two degrees in a given time period.

If the cooling function is selected, the sleep mode can be activated as follows:

  • Press on the sleep button.
    • The indicator for sleep mode will light.
  • Press on the timer button. The number of hours sleep mode will be activated for will be shown in the display.
  • The sleep function is activated when the hours indicator stops flashing and the temperature for the selected function is shown in the display.
    • After one hour the selected temperature is raised by 1^ C. After two hours the selected temperature is raised by further 1^ C.

If the heating function is selected, the sleep mode can be activated as follows:

• The indicator for sleep mode will light.

- Press on the timer button. The number of hours sleep mode will be activated for will be shown in the display.

- The sleep function is activated when the hours indicator stops flashing and the temperature for the selected function is shown in the display.

• After one hour the selected temperature is lowered by 1^ C. After two hours the selected temperature is lowered by a further 1^ C.

- The indicator for sleep mode will light. - Press on the timer button. The number of hours sleep mode will be activated for will be shown in the display. - The sleep function is activated when the hours indicator stops flashing and the temperature for the selected function is shown in the display. - After one hour the selected temperature is lowered by 1^ . After two hours the selected temperature is lowered by a further 1^ .

If the sleep button is pressed when the function is already activated, sleep mode will be deactivated and the icon turned off.

MAINTENANCE AND CLEANING

When SuperCooler VII is used, condensed water etc. collects in the water tanks. The water tanks have a total capacity of 1.2 liters. In order to ensure optimal use of SuperCooler VII, the water tanks should be emptied often.

There are two tanks in SuperCooler VII, an upper and a lower tank. The upper tank has an overflow to the lower tank, which is why it is important that both tanks are emptied regardless of which function has been used.

Thermex SuperCooler VII - MAINTENANCE AND CLEANING - 1

natural_image Line drawing of a portable air purifier with a bowl nearby (no text or symbols)

Place a bowl under the drain for dehumidifying and heating. Remove the rubber plug to drain the water from the tank. Make sure you replace the plug carefully after draining.

Thermex SuperCooler VII - MAINTENANCE AND CLEANING - 2

natural_image Diagram of a multi-tiered air purifier with cooling fans and a bowl below (no text or symbols)

Place a bowl under the drain for cooling. Remove the rubber plug to drain the water from the tank. Make sure you replace the plug carefully after draining.

NOTE: If the tank has been full, the display will flash with the fault code E4. This can be reset by pressing on the on/off button once the tank is empty.

DAILY CLEANING

NOTE: Always disconnect the power before cleaning. SuperCooler VII should be cleaned regularly in order to ensure optimal operations. Wipe the surface off with as damp cloth and detergent. NEVER use abrasives.

CLEANING THE FILTERS

The filters in SuperCooler VII should be cleaned as required. Thermex recommends that the filters are cleaned at least once a month with daily use of SuperCooler VII.

The filters are cleaned as follows:

Thermex SuperCooler VII - CLEANING THE FILTERS - 1

natural_image Technical diagram of a mechanical device with heat exchangers and cooling fins, showing directional arrows (no text or labels)
  • Remove the filters, both the one next to the intake of cold air and the one next to intake of warm air.
  • Wipe off dust and grime from the filters with a damp cloth.
  • Leave the filters to dry.
    • Re-attach the filters.

NOTE: If the filters are damaged, they must be replaced in order to avoid damaging SuperCooler VII.

SERVICE

Before reporting service on your Thermex range hood, it is important that you read the installation and/or user instructions carefully. It ensures that Thermex can provide you the best possible assistance.

Service department at Thermex can be contacted in preparation to:

  • Technical support for installation and installation of your range hood.
  • Clarification of functionalities in your hood.
    • Service Request during the warranty on your hood.

Before a service request during the warranty always try to disconnect the power to the hood for about 5 min. Then plug the power back on to see if the problem is corrected.

If the problem is not corrected, disconnect the power supply to the hood for one hour. If the hood is still not functioning properly, and the troubleshooting charts are reviewed, contact the service department.

NOTE: For inquiries within the warranty, you will be asked for proof of your purchase in the form of a sales receipt. Therefore, always store your sales receipt

Before the request for service within the warranty, it is important to have all the necessary information ready:

  • Error Description
  • Model
    • The type and serial number of the hood (on the chassis plate)
    • Information of purchase

TROUBLE SHOOTER

PROBLEM POSSIBLE CAUSE SOLUTION
Fault code E1 is shown in the display Short circuiting of temperature sensor and circuit boardContact the service department
Fault code E2 is shown in the display Short circuiting of compressor Contact the service department
Fault code E4 is shown in the displayThe water tank is fullEmpty all water from the water tank. Follow the guidelines in the section MAINTENANCE and cleaning on page 62.
SuperCooler VII has stopped and the letters DF are flashing in the display.SuperCooler VII is in the middle of a defrost-ing cycle.SuperCooler VII will start up automatically when it is defrosted.

ENVIRONMENTAL CONSIDERATIONS

PACKAGING

The packaging must be disposed of in accordance with local regulations on waste management.

SCRAPPING OF THE HOOD

The symbol 📋 on the product or accompanying documentation indicates that this product may not be disposed of as household waste but must be delivered to the nearest collection center for the recycling of electrical and electronic equipment.

THERMEX SCANDINAVIA A/S SERVICEAFD.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Thermex

Model : SuperCooler VII

Category : Air-conditioner