IAN 276173 - Lighting Livarno Lux - Free user manual and instructions
Find the device manual for free IAN 276173 Livarno Lux in PDF.
| Product Type | LED Desk Lamp |
| Model | IAN 276173 |
| Brand | Livarno Lux |
| Dimensions (L x W x H) | 40 x 15 x 50 cm |
| Weight | 1.2 kg |
| Power Source | AC 220-240 V, 50/60 Hz |
| Light Source | Integrated LED, 12 W |
| Luminous Flux | 800 lm |
| Color Temperature | 3000-6000 K, adjustable |
| Dimmable | Yes, touch control |
| Lifespan | 25,000 hours |
| Material | Aluminum, ABS |
| Color | White / Silver |
| Certifications | CE, RoHS |
| Protection Class | Class II |
| Adjustable Arm | Yes, flexible joint |
| Cleaning Instructions | Wipe with dry cloth, disconnect power |
| Spare Parts Available | LED module, adapter |
| Repairability | Modular design, parts replaceable |
| Package Contents | Lamp, power adapter, manual |
Frequently Asked Questions - IAN 276173 Livarno Lux
User questions about IAN 276173 Livarno Lux
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Lighting in PDF format for free! Find your manual IAN 276173 - Livarno Lux and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. IAN 276173 by Livarno Lux.
USER MANUAL IAN 276173 Livarno Lux
Assembly, operating and safety instructions
NL
LED-PLAFONDLAMP
Before reading, unfold the page containing the illustrations and familiarise yourself with all functions of the device.
DK
GB/IE/NI Assembly, operating and safety instructions Page 5
List of pictograms used....Page 6
Introduction......Page 6
Intended use....Page 6
Scope of delivery....Page 6
Description of parts....Page 7
Technical data....Page 7
Safety Page 7
Safety instructions......Page 7
Preparation......Page 8
Required tools and material Page 8
Prior to installation Page 8
Mounting Page 8
Mounting the luminaire....Page 8
Aligning the luminaire....Page 9
Start-up Page 9
Inserting / replacing batteries....Page 9
Switching the luminaire on/off....Page 9
Changing the bulb....Page 10
Maintenance and cleaning......Page 10
Disposal Page 10
Guarantee and service......Page 10
Guarantee declaration Page 10
Service address......Page 11
Declaration of conformity....Page 11
Manufacturer....Page 11
| List of pictograms used: | |||
![]() | Read the instructions! | ![]() | Caution!Risk of electric shock |
![]() | Volt (AC) Risk of injury from burns! | ![]() | |
![]() | Hertz (mains frequency) | ![]() | Risk of fire! Install the light so that it is at least 0.5 m from any illuminated materials. |
![]() | Watt (effective power) | ![]() | This light is not suitable for dimmer or electronic switches. |
![]() | Protection class I Safe working | ![]() | |
![]() | Observe the warning and safety instructions! | ![]() | Dispose of packaging and device in an environmentally-friendly way! |
LED ceiling light
- Introduction

We congratulate you on the purchase of your new device. You have chosen a high quality product. Carefully read these
operating instructions all the way through. Fold out the page with the illustrations. These instructions are part of the product and contain important information on placing the product in service and on how to handle the product. Always comply with all safety instructions. Prior to placing the device in service, check whether the correct voltage is present and that all parts have been properly mounted. Should you have any questions, or if you are uncertain how to operate the device, please get in touch with your dealer or service centre. Please keep these instructions in a safe place and hand them on to a third party if necessary.
Intended use
This luminaire is only suitable for indoor use, in dry and enclosed rooms. The luminaire can be fastened
to all normally inflammable services. This device is intended for use in private households only.
- Scope of delivery
Immediately after unpacking, check that the scope of delivery is complete and that the device is in faultless condition.
1 Ceiling luminaire, model 14104302L or 14112202L (5-light)
5 LED bulbs E14, 3 W
5 Lamp lenses
1 Remote control unit
1 Battery, 12 V—, A23
2 Dowels
2 Screws
2 Ceiling holder clips
2 Screws (ceiling holder clips)
2 Rawlplug (ceiling holder clips)
1 Tool
1 Set of operating instructions
• Description of parts
1 Mounting bracket with slotted holes
2 Screws
3 Mains connection cable (external)
4 Terminalblock
5 Receiver
6 Connectionhousing
7 Lamp arm
8 Spot
9 Remote control unit
10 Ceiling holder clip
11 Ceilingholder
12 Dowel (ceiling holder clip)
13 Dowel
14 Bulbsocket
15 Lamplens
16 Threadedring
17 Tool
18 Bulb
19 Protective tubes
- Technical data
Ceiling luminaire:
Operating voltage: 230-240V\~, 50Hz
LED bulbs: 220-240 V\~, 3 W, E14
Rated power, maximum: 5 x 3 W
Protection class: I/
Remote control receiver:
Rated voltage: 220-240V\~, 50Hz
Max. load capacity: 1000 W
Frequency: 433.92 MHz
Remote control transmitter:
Operating voltage: 12V —, A23
Frequency: 433.92 MHz
- Safety

Safety instructions
Damages due to failure to comply with these operating instructions will void the guarantee! We assume no liability for consequential damages! We assume no liability for material damage or personal injury due to improper handling or failure to comply with the safety instructions!

Avoid life-threatening danger due to electric shock
■ Ensure that a qualified electrician or a person trained to carry out electrical installations performs the electrical installation.
■ Always check the luminaire, the power supply, and the mains cable for damage before plugging it in. Never use the luminaire if it shows any signs of damage.
CAUTION! A damaged mains cable means life-threatening danger due to electric shock. In the event of damage, repairs or other problems with the luminaire, contact the service centre or a qualified electrician.
Before installation, remove the fuse or switch off the circuit breaker (0 setting) in the fuse box.
Before mounting, ensure that the available mains voltage corresponds to the operating voltage required for the luminaire (230–240 V\~).
■ Strictly avoid the luminaire from coming into contact with water or other liquids.
■ Never open a component of the electrical equipment or insert anything into a component of the electrical equipment. Such interventions pose life-threatening danger due to electric shock.
Do not install the luminaire on a wet or conductive substrate!

Avoid fire hazards and injury hazards
⚠️ DANGER OF INJURY! Check every bulb and lamp lens for damage immediately upon unpacking.
Do not mount the luminaire with defective bulbs and / or lamp lenses. In this case contact the service centre for replacement.
DANGER OF BURN INJURIES

Ensure that the luminaire has been switched off and has cooled before touching it, to avoid burn injuries. Bulbs develop a lot of heat in the area of the lamp holder.
- Allow the luminaire to cool completely.
- Replace faulty bulbs with new bulbs immediately. Before replacing the bulb, always remove the fuse or switch off the circuit breaker, first.
FIRE HAZARD! Mount the luminaire so that it is at least 0.5 m away from the materials to be illuminated.
Fire can result from excessive heat development.
Do not leave the luminaire or packaging material unattended. Plastic film or bags, plastic parts etc. can become dangerous playthings for children.
This light is not suitable for dimmer or electronic switches.
Do not look directly in to the light source (lamp, LED, etc.).

Safe working
■ Onlyuse 220-240V \~ LED lamps with E14 base and a maximum output of 3 Watt.
■ Mount the luminaire so that it is protected from moisture and dirt.
■ Make careful preparations for mounting and take sufficient time. Clearly lay out all components and any additional tools or materials that may be required so that they are readily to hand.
- Constant attentiveness is required! Always pay attention to what you are doing and act with common sense. Do not, under any circumstances, install the luminaire if you are having difficulty concentrating or do not feel well.
● Preparation
- Required tools and material
The tools and materials cited are not included in the scope of delivery. This information and these values are non-binding and are provided for purposes of orientation. The condition of the material is determined by the individual local conditions.
- Pencil/marking tool
- Voltage tester
- Screwdriver
- Electric drill
- Bit (ø approx. 0.6 cm)
- Side cutting pliers
- Ladder
- Prior to installation
Important: The electrical connection must be established by a qualified electrician or a person trained to perform electrical installations. This person must be familiar with the characteristics of the luminaire and connection regulations.
☐ Familiarise yourself with all instructions and diagrams in this manual, as well as with the luminaire before installation.
Before installation, ensure that the cable that the luminaire will be attached to is de-energised. To do this, remove the fuse or switch off the circuit breaker in the fuse box (0 position).
☐ Use the voltage tester to verify de-energised status.
- Mounting
Mounting the luminaire
☐ Remove the visible screws 2 on the side of the connection housing 6 and take off the mounting bracket 1 on the rear (see Fig.).
☐ Use the slotted holes intended for the mounting bracket 1 to mark the bores.
Drill the fastening bores (approx. 6 mm, depth approx. 40 mm). Ensure that you do not damage the supply line.
☐ Introduce the dowels 13 into the bores. Fasten the mounting bracket 1 with the provided screws (large screw head).
☐ Feed the power cord (external) through the protective tubes 19 (see fig.).
☐ Connect the mains cable (external) 3 via lustre terminal 4.
☐ Also ensure that the coloured lines are connected together
(conductive wire, black or brown = symbol L, neutral wire, blue = symbol N).
☐ Connect the protective conductor (green-yellow) to the earth terminal marked in the connection housing 6 (see Fig.).
☐ Use the screws 2 to fasten the luminaire to the mounting bracket 1.
☐ Bring the lamp arm 7 in the desired direction.
☐ Mark the fastening bores for the ceiling brackets 11. Ensure that the bores are always between two spots 8 (see Fig.). This ensures a more secure hold.
Drill the fastening bores (approx. 6 mm, depth approx. 40 mm) for the ceiling holders ^11 . Be careful not to damage the supply line.
☐ Introduce the dowels 12 into the bores. Use the provided screws to fasten the ceiling holders 11 (small screw head).
☐ Screw the ceiling bracket clips 10 into the ceiling brackets 11.
☐ Clamp the lamp arm 7 into the ceiling bracket clips 10.
□ Loosen the threaded ring 16.
Place the lamp lens 15 carefully over the bulb socket 14 and fasten it in place by tightening the threaded ring 16 using the supplied tool 17. Ensure it is correctly seated.
☐ Use a clean, lint-free cloth to insert a bulb 18.
☐ Carefully turn the bulb 18 clockwise into the bulb socket.
Ensure that it is properly seated.
☐ Replace the fuse or switch on the circuit breaker (Position I) inside the fuse box.
Your luminaire is now ready for operation.
• Aligning the luminaire
CAUTION! DANGER OF BURN INJURIES!
Allow the luminaire to cool completely.
☐ Only change the alignment of the luminaire when it is switched off.
□ Allow the luminaire to cool completely.
☐ Turn the individual spots 8 on the base in the desired direction. The spots 8 can be turned approx. 270^ , and they can also tilt.
- Start-up
- Inserting / replacing batteries
☐ Loosen the screw on the battery compartment of the remote control unit 9 (rear) by unscrewing it with a crosshead screwdriver in the direction.
☐ Remove the spent battery, if necessary.
☐ Insert a new battery into the battery compartment. Only use type A23, 12 V--- batteries.
Note: Ensure the correct polarity. This is shown in the battery compartment.
☐ Close the battery compartment of the remote control unit 9 (rear) by screwing in the screw with a Phillips screwdriver in the C direction.
- Switching the luminaire on / off
You have the possibility of operating the luminaire from an ordinary wall switch or switching it on and off using the supplied remote control unit.
Switching the luminaire on / off using the remote control unit:
- The wall switch is in basic position (OFF).
□ Activate the wall switch (ON).
☐ Press the ON button of the remote control unit 9 to switch on the luminaire.
☐ Press the OFF button of the remote control unit 9 to switch off the luminaire.
Switching the luminaire on / off using the wall switch:
- The wall switch is in basic position (OFF).
☐ Switch on the luminaire by activating the wall switch (2–3 switch cycles). The luminaire can subsequently be switched on and off via the wall switch or the remote control unit 9.
Fault correction: If the remote control unit 9 does not respond after switching on the luminaire, first activate the wall switch to switch off the luminaire. Then wait for 15–20 seconds and repeat the 2nd point under „Switching the luminaire on / off via the wall switch”. If the remote control 9 still doesn't respond after repeated switching on the light, please check the battery inside the remote control 9.
- Changing the bulb
CAUTION! DANGER OF ELECTRIC SHOCK!
To replace the bulb, first disconnect the luminaire from the mains circuit. To do this, remove the fuse or switch off the circuit breaker in the fuse box (0 position).
CAUTION! DANGER OF BURN INJURIES!
Allow the luminaire to cool completely.
☐ Replace the bulb 18 only after it has fully cooled.
☐ Turn the defective bulb 18 carefully anticlockwise out of the bulb socket 14.
☐ Use a clean, lint-free cloth to replace a bulb.
☐ Onlyuse 220-240V \~ LED lamps with E14 base and a maximum output of 3 Watt.
☐ Screw the new bulb 18 into the bulb socket clockwise. Check for proper seat.
☐ Replace the fuse or switch on the circuit breaker (Position I) inside the fuse box.
● Maintenance and cleaning
CAUTION! DANGER OF ELECTRIC SHOCK!
To clean the luminaire, first disconnect it from the mains circuit. To do this, remove the fuse or switch off the circuit breaker in the fuse box (0 position).
CAUTION! DANGER OF ELECTRIC SHOCK!
For electrical safety reasons, never clean the luminaire with water or other fluids nor immerse it in water.
CAUTION! DANGER OF BURN INJURIES!
Allow the luminaire to cool completely.
- Do not use solvents, benzene or similar substances. They could damage the luminaire.
☐ Only use a dry, lint-free cloth for cleaning.
☐ Replace the fuse or switch on the circuit breaker (Position I) inside the fuse box.
- Disposal
The package and packaging materials consist entirely of environmentally friendly materials. They can be disposed of at your local recycling facility.
The symbol of the dustbin with the line through it means that in the European Union the product must be disposed of
in a separate trash collection. This applies to the product and to all components bearing this symbol. Products marked in this manner must not be disposed of along with normal household waste, but rather must be taken to a recycling collection point for electrical and electronic appliances. Recycling helps to reduce the consumption of raw materials and protects the environment.
Batteries must not be disposed of in the household trash! Return batteries and / or the device to a a local recycling facility.
● Guarantee and service
●Guarantee declaration
This product has a 3-year guarantee from the date of purchase; the guarantee is only valid for the original purchaser and is not transferable. Keep your receipt as proof of purchase. The guarantee applies to material or manufacturing defects only. It does not cover wear parts or damage caused by
improper use. The guarantee is void in cases of unauthorised tampering. This guarantee does not limit your legal rights. Contact the service centre by telephone if there is a guarantee case. This is the only way to ensure that your device can be sent in free of charge.
Serviceaddress
When inquiring about your product, have your receipt and product number (e.g. IAN 12345) ready as your proof of purchase.
- Declaration of conformity CE
This product fulfils the requirements of the applicable European and national directives (Electromagnetic Compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU, Ecodesign Directive 2009/125/EC, RoHS Directive 2011/65/EU, Directive 2014/53/EU). Conformity has been demonstrated. The relevant declarations and documents are held by the manufacturer. Briloner Leuchten GmbH hereby declares the wireless system model 14104302L / 14112202L or 14104108L to comply with Directive 2014 / 53 / EU. The full text of the EU declaration of conformity is available at: www.briloner.com
Manufacturer
Montering....Side 16
Montering af lampen....Side 16
Justering af lampen....Side 17
Ibrugtagning....Side 17
- Inden installation
59929 Brilon (Germany)
Last Information Update · Tilstand af information · Stand van de