PCE Instruments PH 17 - Meter

PH 17 - Meter PCE Instruments - Free user manual and instructions

Find the device manual for free PH 17 PCE Instruments in PDF.

📄 1 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice PCE Instruments PH 17 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypepH Meter
ModelPH 17
BrandPCE Instruments
Measurement Range (pH)0.00 to 14.00 pH
Resolution0.01 pH
Accuracy±0.05 pH (typical)
Temperature CompensationAutomatic (ATC)
Temperature Measurement Range0 to 60°C (32 to 140°F)
DisplayLCD with backlight
Calibration1 to 3 point automatic
Power Supply2 x 1.5V AAA batteries
Battery LifeApprox. 300 hours continuous use
Housing ProtectionIP67 (waterproof)
Dimensions185 x 72 x 36 mm
Weight200 g (including batteries)
Electrode ConnectorBNC
Electrode IncludedReplaceable pH electrode
Auto-OffAfter 10 minutes inactivity
Operating Temperature0 to 50°C
Included AccessoriesBuffer powders, calibration solutions, manual

Frequently Asked Questions - PH 17 PCE Instruments

How do I calibrate the PCE Instruments PH 17 pH meter?
Perform a 2-point calibration using pH 4.00 and pH 7.00 buffer solutions. Rinse the electrode with distilled water, immerse in pH 7.00, wait for stable reading, press CAL, then repeat with pH 4.00. For best accuracy, use a third point at pH 10.00.
How often should I recalibrate the pH meter?
Recalibrate before each series of measurements or at least once daily. Also recalibrate if the electrode has been dry or after measuring strong acids or bases.
What kind of batteries does the PH 17 use?
It uses two 1.5V AAA batteries. Battery life is approximately 300 hours of continuous use.
How do I replace the electrode?
Unscrew the old electrode clockwise (looking from front), pull it out, and screw in a new pH electrode with BNC connector. Ensure the O-ring is properly seated to maintain waterproofing.
Why is the reading unstable?
Unstable readings may be due to a dirty electrode, low battery, or air bubbles on the electrode. Clean the electrode with distilled water, replace batteries if needed, and recalibrate.
How do I store the meter when not in use?
Store the electrode in a storage solution (KCl 3M) or pH 4.00 buffer. Do not let it dry out. Remove batteries if storing for long periods.
Is the meter waterproof?
Yes, the PH 17 is IP67 rated, meaning it is dust-tight and can withstand immersion in up to 1 meter of water for 30 minutes.
What is the measurement range for temperature?
The temperature measurement range is 0 to 60°C (32 to 140°F) with automatic temperature compensation (ATC).
Can I measure in aggressive chemicals?
The standard electrode is for general aqueous solutions. For aggressive chemicals (e.g., strong acids, organic solvents), use a specialized electrode designed for such environments.
What does the auto-off feature do?
The meter automatically turns off after 10 minutes of inactivity to save battery life. Press any button to wake it up.

User questions about PH 17 PCE Instruments

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Meter in PDF format for free! Find your manual PH 17 - PCE Instruments and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PH 17 by PCE Instruments.

USER MANUAL PH 17 PCE Instruments

Accuracy: 0.1PH(at 20 ), 0.2PH

Resolution:0.01PH Operating Temperature: 0 50

Calibration: Manual, at one point through trimmer

Power Supply: 3 1.5V(AG-13 battery)

Dimensions:175mm 51mm 25mm. Weight: 57g

Operation

  1. Remove the protective cap.
  2. First rinse the electrode with distilled water, and suck it with filter-paper.
  3. Turn the meter on by pressing the ON key.
  4. Immerse the ph meter electrode in the solution to be tested.
  5. Stir gently and wait for the reading to stabilize.
  6. Press the "HOLD" key, the reading is be kept. When repeat measuring, please press the "HOLD" key again, it automatically relieves the hold condition.
  7. After use, rinse the electrode with water to minimize contamination. Turn the meter off by pressing the OFF key.
  8. Always replace the protective cap after use.

PH Calibration

  1. Immerse the electrode in pH 6.86(pH7.00) buffer solution of phosphate, and gently shake it.
  2. Allow the reading to stabilize and with a small screwdriver turn the calibration trimmer until the display shows "6.86"("7.00"). Rinse the electrode with distilled water, and suck it with filter-paper.
  3. Immerse the electrode in pH4.01 or pH9.18(pH10.0) the buffer solution of borax.
  4. After about one minute, until the display shows "4.01" or "9.18" ("10.0").

Important:

The instrument's pH range must be re-calibrated whenever:

The electrode has been used(laid) for long time from the last calibration.

The electrode has been used in particularly taxing conditions.

The utmost accuracy is required.

Battery Install

If the meter can not be switched on or the display fades, To change batteries, takes down the meter back battery case and replaces batteries. Pay attention to the polarity of battery.

Warranty

These instruments are warranted from all defects in material and manufacturing for a period of one year from the date of purchase.

If during this period, the repair or the replacement of parts is required where the damage is not due to negligence or erroneous operation by user, please return the parts to either dealer or our offices, and the repair will be effected free of charge.

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PCE Instruments

Model : PH 17

Category : Meter