UT-LS15-US - Mètre Uni-T - Free user manual and instructions
Find the device manual for free UT-LS15-US Uni-T in PDF.
| Product Type | AC Line Splitter |
| Brand | Uni-T |
| Model | UT-LS15-US |
| Input/Output Rating | 125V~, 60Hz, 15A |
| Dimensions | 124mm x 58mm x 40mm |
| Weight | 120g |
| Operating Temperature | 0°C to 50°C (32°F to 122°F) |
| Storage Temperature | -20°C to 60°C (-4°F to 140°F) |
| Humidity | Max 80% up to 31°C, decreasing linearly to 50% at 40°C |
| Maximum Altitude | 7000 feet (2100 meters) |
| Safety Compliance | CAT III 300V, Pollution degree 2 |
| Certifications | ETL Listed, Conforms to UL STD. 61010-1, 61010-2-030; CSA STD. C22.2 No. 61010-1, 61010-2-030 |
| Current Multiplication Factor | 10x (divide meter reading by 10) |
| Primary Function | Separate live and neutral wires for safe clamp meter current measurement |
| Compatible Outlets | Standard US/Canadian 125V AC outlets |
| Indoor Use | Yes |
| Maintenance | Keep dry, clean with damp cloth, avoid strong impact, store at normal temperatures |
| Safety Symbols | Refer to manual for safety information; hazardous voltage; alternating current |
Frequently Asked Questions - UT-LS15-US Uni-T
User questions about UT-LS15-US Uni-T
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Mètre in PDF format for free! Find your manual UT-LS15-US - Uni-T and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. UT-LS15-US by Uni-T.
USER MANUAL UT-LS15-US Uni-T
AC Line Splitter Operating Instructions
Introduction
UT-LS15-US AC line splitter provides a safe and simple solution for measuring AC operating current of electrical devices.
A power cord includes a live wire and a neutral wire insulated from each other. When measuring current flowing through a conductor with a clamp meter, a reading of zero will always be measured if the jaw clamp around the entire power cord. This because the current flowing though live wire and neutral wire is in reverse, the current magnetic fields neutralized each other. In order to accurately measure current flowing through AC lines, the two wires need to be separated, clamp any one of them after removing the insulated jacket of the power cord to perform measurement. The AC line splitter can separate live wire and neutral wire without damaging any insulation.
To obtain more accurate reading when measuring small currents, the splitter increases readings by 10 times, which can then be measured by a clamp meter. Therefore, the measurement should be divided by 10 to get the actual result.
With proper use, the AC line splitter can provide users with many years of reliable service.
Warning
- Please read, understand and follow the safety rules and instructions in the manual.
- The protection is ineffective when the safety rules and instructions are not followed.
- For use on standard US, Canadian, and other same type of 125V AC outlets only.
- Do not test current of more than AC 15A.
Certification and Safety Rating Descriptions

Conforms to UL STD. 61010-1, 61010-2-030; Certified to CSA STD. C22.2 No. 61010-1, 61010-2-030.
Intertek 4007682
- Using this product for any purposes other than those described above may damage the product and result in a short circuit, fire or electric shock. The product must not be modified or reassembled!
- MEASUREMENT CATEGORY III is applicable to test and measuring circuits connected to the distribution part of the building's low-voltage MAINS installation.
- Indoor use only.
Safety Symbols
| Potential danger. Indicates the user must refer to the manual for important safety information. | |
| Indicates hazardous voltages may be present. | |
| ~ | Alternating current |
| ETL Listed |
| Potential danger. Indicates the user must refer to the manual for important safety information. | |
| Indicates hazardous voltages may be present. | |
| ~ | Alternating current |
| ETL Listed |
Maintenance
Please maintain the AC line splitter according to the followings,
1. Keep the device dry. Please use clean cloth to wipe when the case or socket is wet. No wet splitter should be used.
2. Use and store the device in normal temperatures. Using or storing it in other temperatures may shorten its service life or melt its cover.
3. Use the device gently. Strong impact or drop from height can damage the electrical parts or the case.
4. Keep the device clean. Wipe dirt off with clean damp cloth. Do not use chemicals, cleaning solvents, or detergents.
Operating Instructions
- Plug the appliance being tested into the AC line splitter
-
Plug the line splitter into an AC outlet
-
Power on the appliance
- Follow the AC current measurement instructions of clamp meter
- Make sure the jaws are fully closed before taking a reading.
- Divide the clamp meter reading by 10 to get the actual operating current of the appliance. For example, if the clamp meter displays AC 10A, the actual operating current is AC 1A.

General Specifications
| Input/Output | 125V~, 60Hz, 15A |
| Operating Temperature | 0°C to 50°C (32°F to 122°F) |
| Storage Temperature | -20°C to 60°C (-4°F to 140°F) |
| Humidity | Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F (40°C) |
| Altitude | 7000 feet (2100 meters) maximum |
| Safety Compliance | CAT III 300V |
| Pollution grade | 2 |
| Product size | 124mmX58mmX40mm |
| Weight | 120g |