| Product Type | Water Pump |
| Model | XKJ-1305S |
| Brand | Cotech |
| Power Supply | 230V ~ 50Hz |
| Power Consumption | 750 W |
| Max Flow Rate | 5000 L/h |
| Max Head | 35 m |
| Max Liquid Temperature | 35 °C |
| Max Particle Size | 1 mm |
| Housing Material | Stainless Steel / Plastic |
| Impeller Material | Technopolymer |
| Seal Type | Mechanical Seal |
| Protection Class | IP68 |
| Dimensions (W x H x D) | 20 x 30 x 20 cm |
| Weight | 5 kg |
| Power Cable Length | 10 m |
| Functions | Drainage, transfer, circulation |
| Maintenance | Regular cleaning of filter; check seals annually |
| Safety | Thermal overload protection; automatic shut-off |
| Spare Parts | Impeller, seal kit, cable |
| Repairability | Repairable; spare parts available separately |
Frequently Asked Questions - XKJ-1305S Cotech
User questions about XKJ-1305S Cotech
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Water pump in PDF format for free! Find your manual XKJ-1305S - Cotech and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. XKJ-1305S by Cotech.
USER MANUAL XKJ-1305S Cotech
Read the entire instruction manual carefully and make sure that you fully understand it before you use the equipment. Keep the manual for future reference.
Viktig information:
natural_image
Technical line drawing of an electric motor with attached housing and mounting base (no text or symbols)ART.NO
18-3114
30-1004
MODEL
XKJ-1305S-UK
XKJ-1305S
Ver. 20150126
Original instructions
Bruksanvisning i original
Please read the entire instruction manual before using the product and save it for future reference. We reserve the right for any errors in text or images and any necessary changes made to technical data. If you have any questions regarding technical problems please contact our Customer Services (see address on reverse).
Safety
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
• Children shall not play with the appliance. - Cleaning and user maintenance shall not be made by children without supervision.
- The mains lead should be checked regularly. Never use the product if the mains lead or plug is damaged.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- Use the pump only as described in this instruction manual.
- Always use a residual current device (RCD or RCCB) which trips at < 30 mA between the pump and the power supply.
-
Always inspect the pump before using it, especially the power lead and plug. Never use the pump if any of the parts is damaged.
-
Make sure that the pump and all electrical connections (extension lead, RCD, etc) are placed in a dry place and protected from rain, moisture and high water level. The temperature should not exceed 35 °C.
- Do not expose the mains lead to extreme heat, oil or sharp edges.
- Keep children and animals away from the pump when it is running.
- The pump must not be used for corrosive, flammable or explosive liquids such as petrol, kerosene or thinners.
- The pump should also not be used for grease, oil, saltwater, brackish water, urine or toilet sewage water.
- The pumped liquid's temperature must not exceed 35 ^ C.
- Keep everyone out of the liquid (pool, etc.) being pumped.
- The operator of the pump is responsible for the safety of the pump and all its applications.
• Always unplug the pump before adjusting, repairing, etc. - Do not expose the pump directly to jets of water.
- The pump should only be repaired by a qualified electrician using original parts.
- The pump must not be run dry since this will wear out the pump. Turn off the pump as soon as water has stopped coming out of the hose. The guarantee will be void if the pump is damaged due to dry running.
- The pump must only be used by those who have read the instruction manual. Keep children and animals away from the pump, especially if it is under pressure.
Product Description
Operating Range
The pump is intended for domestic use; in the home and garden.
Suitable uses:
• Watering gardens, vegetable gardens, lawns, etc.
- Pumping water from springs, wells, water containers, etc.
Note: The pump is only designed for pumping clean water except drinking water.
Parts

- Drain plug
- Pressure hose connection (Female R25,1")
-
Suction hose connection (Female R25)
-
Filler plug
-
Handle
-
Power switch
Before using
Placement
Prevent water damage. Pre-planning prevents accidents!
Leakage in the pump and hoses may occur through freezing, incorrect installation, pressure surges, etc. The pump should therefore be placed in a waterproof environment approved by your insurance company and your insurance policy.
Contact your insurance company if you are unsure.
Place the pump on a firm, hard surface, well protected from water spray.
Suction hose connection
- Connect a 25 mm (1") diameter hose to the suction hose connection (R25) on the pump.
- The suction hose should be equipped with a foot valve with a non-return valve that is placed at the end of the suction hose (pipe).
- Place the suction hose so that it slopes upwards from the water to the pump inlet connection.
- The suction hose must always be on a lower level than the inlet to the pump. Air-pockets in the hose could disrupt the pump's operation.
- Hoses or pipes must not be connected in such a way as to exert any pulling strain or tensile stress on the pump unit.
- The foot valve should be anchored to the bottom so that the pump does not run dry if the water level drops.
- The suction hose assembly must be air-tight to prevent air from being sucked into the pump.
- A filter should be fitted to the suction side to prevent sand, mud, etc from being sucked into the pump.
Pressure hose connection (outlet)
Connect a hose with a min.12.5 mm (1/2") diameter to the outlet connection (R25).
Mains connection
- Connect the mains lead to an RCD protected earthed socket for personal safety.
- The pump has a built-in thermal motor protection and automatically shuts off when overheating (and re-starts automatically when cooled).
Starting the pump
- Place the pump on a firm, hard surface, well protected from water spray.
- Connect the suction hose to the suction inlet (3).
- Connect the mains lead to an RCD protected earthed socket for personal safety.
- Fill the pump housing with water via the filler hole (4).
- Connect the pressure hose to the outlet connection (2).
- Turn the pump on using the power switch (6). It can take from four to six minutes for the pump to reach maximum effectiveness, depending on the pressure head, and amount of air on the suction side. Fill the pump with water via the filler hole (4) once more if the pump does not work satisfactorily after six minutes.
- If the pump is detached and reattached the pump unit should be filled with water via the filler hole (4).
Maintenance
• Always unplug the pump before carrying out any kind of maintenance.
- Use a soft lightly moistened cloth to clean the plastic pump parts. Never clean the product using strong detergents or solvents.
- If there is a risk of frost or if the pump is not being used during winter it should be emptied of water. Store the pump in a dry place.
- If the pump has not been run for a while it is a good idea to check that the rotor moves freely by quickly turning the pump on and off.
- The pump should be checked regularly. Check the operation and inspect for any damage.
General guidelines
- Dry running of the pump should be avoided because it increases wear.
- Pull the plug not the lead when unplugging the pump from the mains.
- Never lift or carry the pump by its power lead.
- Sand and other abrasive substances in the liquid that is pumped will increase wear and tear and reduce the capacity of the pump.
- Make sure that the recommended suction head (8 m) is not exceeded.
- Protect the pump from frost.
- The pump is designed for intermittent use, not continual operation such as for a fountain.
Troubleshooting
| Problem Possible Cause Remedy | ||
| The pump does not start. | No power supply. Check fuses and RCD,etc. | |
| Dirt lodged in the pump. Remove any dirt or deposits. | ||
| The thermal protection device has triggered. | Unplug and clean the pump Remember that the max. liquid temperature cannot exceed 35 °C. | |
| The pump is running but does not pump. | There is air in the pump. Open all nozzles and valves etc. so the air can pass through. | |
| The suction hose is above the water's surface. | Place it below the water surface. | |
| Suction hose leaking. Tighten, or seal the leak. | ||
| Max. suction head exceeded. Check suction head (max. 8 m). | ||
| Max. pressure head exceeded. Check pressure head (max. 46 m). | ||
| The pump has diminished capacity or low pressure. | Max. suction head exceeded. Check suction head (max. 8 m). | |
| Max. pressure head exceeded. Check pressure head (max. 46 m). | ||
| The suction hose is above the water level. | Place it below the water surface. | |
| Dirt lodged in the pump. Remove any dirt or deposits. | ||
| The pump stops suddenly. | The thermal protection device has triggered. | Unplug and clean the pump. Remember that the max. liquid temperature cannot exceed 35 °C. |
Disposal
Follow local ordinances when disposing of this product. If you are unsure of how to dispose of this product, please contact your municipality.

Specifications
Rated power 1300 W
Rated voltage 230 V AC, 50 Hz
Max. pump capacity 65 l/min
Max. pressure 4.6 bar
Max. water temperature 35 °C
Max. pressure head 46 metres
Max. suction head 8 metres
Hose connections R25 female thread
Size 38 × 25 cm
Weight 9.8 kg
Trädgårdspump 1300 W
ART.NR 18-3114 MODELL XKJ-1305S-UK
30-1004
XKJ-1305S
Declaration of Conformity
Declares that this product complies with the requirements of the following directives and standards
Machinery directive 2006/42/EC
EMC directive 2004/108/EC
Low voltage directive 2006/95/EC
EN 55014-1:2006+A1+A2
EN 60335-1:2012
EN 55014-2:1997+A1+A2
EN 60335-2-41:2003
EN 61000-3-2:2006+A1+A2
+A1+A2
EN 61000-3-3:2008
EN 62233:2008

President
Insjön, Sweden, 2013-10-31
SVERIGE
KUNDTJÄNST Tel: 0247/4 45 00
Fax: 0247/4 45 09
E-post: kundservice@clasohlson.se
INTERNET www.clasohlson.se
BREV Clas Ohlson AB, 793 85 INSJÖN
NORGE
KUNDESENTER Tlf.: 23 21 40 00
Faks: 23 21 40 80
E-post: kundesenter@clasohlson.no
INTERNETT www.clasohlson.no
POST Clas Ohlson AS, Postboks 485 Sentrum, 0105 OSLO
SUOMI
ASIAKASPALVELU Puh.: 020 111 2222
POSTAL 10 – 13 Market Place
Kingston Upon Thames
Surrey
KT1 1JZ