7090 - Weather Station Weinberger - Free user manual and instructions
Find the device manual for free 7090 Weinberger in PDF.
User questions about 7090 Weinberger
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Weather Station in PDF format for free! Find your manual 7090 - Weinberger and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 7090 by Weinberger.
USER MANUAL 7090 Weinberger
natural_image
Four black-and-white icons representing industrial and transportation-related symbols (no text or labels)Entsorgungshinweise
natural_image
Symbol of a recycling bin with no text or numbers presentnatural_image
Technical line drawing of a mechanical component with mounting holes and internal cavity (no text or symbols)text_image
Mebus® WIRELESS SENSOR C1 C2 C3 C4C1 - LED Indikator
C2 - RESET
C3 - Kanalwahl
C4 - Batteriefach
Inbetriebnahme
natural_image
Simple line drawing of a cloud with raindrops below (no text or symbols)Sonne
Sonne mit Wolken
Wolken ohne Sonne
text_image
Thomas FinkThomas Fink
Geschäftsführer
Features
Weather forecast with sunny, clear, cloudy, rainy.

Seven key functions: SET, ALARM, CHANNEL, MAX/MIN, +, ,SNZ
Radio Controlled(DCF)
Weekday display in 7
languages: : English, French, Italian, Spanish, German, Dutch, Danish.
6 digit display: hour, minutes, seconds
Calendar(2000-2099)
12/24 hours selectable
C/F selectable
3½ digit Indoor Temperature Display, Detection Accuracy 0.1°C, Detection Range 0°C--50°C, Detection time 15 Seconds
2 digit indoor humidity display, detection accuracy 1%, detection range of 20%-95%, detection time of 15 seconds
3 12 digit RF outdoor temperature and 2 digit humidity display, the maximum receiving 3 different channel signal
2 digit outdoor humidity display, detection accuracy1%, detection range of 20%-95%
Indoor/our door temperature trend.
Max/min memory record
Outdoor low power indicator
Comfort index
3 outdoor temperature / humidity display channel
Key tone "BI"
Alarm and snooze Function
Indoor Low power indicator
time zone settings, -12/+12 hours bias
DST function
Eight kinds moon phase display
Display / Keys Details:
Press "SET" and handle for three seconds to enter the time setting mode
Press "ALARM" key turn on /turn off Alarm
Press "ALARM" button and handle for 2 seconds to enter the Alarm setup mode Press "+" button to choose 12/24 hours

Press " " button to switch C/F

Press " [REDACTED] " and handle for 2 seconds to enter the RCC receive mode
Press "MAX/MIN" button to view the temperature and humidity of the maximum/minimum value
Press "MAX/MIN" button and handle for 2 seconds, remove all historical records of temperature/ humidity
Press "KANAL" key, choose RF channel, the display order is CH1 - CH2 -CH3 - CH1 Press "KANAL" button more than 2 seconds to register channel

In RCC receiving mold, press: " " and handle for 2 seconds to exit the RCC receive mode
When alarm sounds, press the SNOOZE button to trigger snooze for 5 minutes. The alarm icon flashes when the snooze feature is active.
To set Clock / Date:
Press "SET" button and handle for 2 seconds, enter the time setting mode
The project will flicker at a frequency of 1HZ
Set the following order: year, month, day, hour, minutes, OFFSET, after the set finish, exit set up mode
Set finish, click "SET" to exit
Press "+" button, set the value of next step, press and handle for 2 seconds, set the value will 8 times than normal speed.

Press by the "☐" button, set the value of a step back, press and handle for 2 seconds, set the value will 8 times than normal speed.
Moon Phase indication and week indication follow with month and day change
When 8 seconds without any operate, exit the setting mode automatically, the setting values will be stored
TIME ALARM:
Press "ALARM" button and handle for 2 seconds to enter the alarm mode
The project will flicker at a frequency of 1HZ
Set turns following order: hours, minute.
Press "+" button, set the value of next step, press and handle for 2 seconds, set the value to 8 times than normal speed.

Press " " button, set the value of the step back, press and handle for 2 seconds, set the value will 8 times than normal speed
Set finish, click "ALARM" to exist.
When 8 seconds without any operate, exit the setting mode automatically, the setting values will be stored
Declaration of Conformity
Regarding 1999/5/EC, 2004/108/EC, 2006/95/EC and 2011/65/EU
We, the WEINBERGER GmbH & Co.KG, Bergische Str. 11, 42781 Haan declares hereby, that the following product fulfills the above mentioned regulations.
| Product description: | Wireless Weather Station |
| Art. no.: | 40345 |
| Model number: | 7090 |
| Ref. No. : | 2714 |
The above mentioned product fulfills the following European Standards:
Standard(s)
EN 301 489-1 V1.9.2 (2011-09)
EN 301 489-3 V1.4.1 (2002-08)
EN 300 220-1 V2.4.1 (2012-05)
EN 300 220-2 V2.4.1 (2012-05)
EN 300 330-1 V1.7.1 (2010-02)
EN 300 330-2 V1.5.1 (2010-02)
EN 60950-1:2006+A11:2009+A1:2010+A12:2011
EN 62321:2009