UnicalAir

UND A 12H - Air-conditioner UnicalAir - Free user manual and instructions

Find the device manual for free UND A 12H UnicalAir in PDF.

📄 20 pages English EN Download 💬 AI Question
Notice UnicalAir UND A 12H - page 2
View the manual : English EN Italiano IT
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about UND A 12H UnicalAir

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air-conditioner in PDF format for free! Find your manual UND A 12H - UnicalAir and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. UND A 12H by UnicalAir.

USER MANUAL UND A 12H UnicalAir

natural_image Front view of a white Unical air conditioner unit with control panel and indicator lights (no visible text or symbols on the device itself)

wall type air conditioners

• FOR THE AIR CONDITIONER TO OPERATE SATISFACTORILY, INSTALL IT AS OUTLINED IN THIS MANUAL
- BE CAREFUL NOT TO SCRATCH THE AIR CONDITIONER UNITS WHEN HANDLING THEM.
- CONNECT THE INDOOR UNIT AND THE OUTDOOR UNIT WITH PROPER CORDS AND AIR CONDITIONER PIPING
- MOVING A SPLIT AIR CONDITIONER TO ANOTHER LOCATION REQUIRES SPECIAL TECHNIQUE. IF NECESSARY, CONSULT WITH THE SELLER.

INSTALLATION ACCESSORIES

UnicalAir UND A 12H - wall type air conditioners - 1Name and drawing Quantity Application
Wall hook bracket for the indoor unit 01 To mount the indoor unit
UnicalAir UND A 12H - wall type air conditioners - 2Power cable 01 For interconnecting the indoor and outdoor units
UnicalAir UND A 12H - wall type air conditioners - 3Pipette for condensed water drainage 01 For the outdoor unit drainage
UnicalAir UND A 12H - wall type air conditioners - 4Pipe insulation sleeve 01 To insulate the joints of the indoor unit
UnicalAir UND A 12H - wall type air conditioners - 5Remote control 01

1

SELECTING THE INSTALLATION PLACE

INDOOR UNIT

• Install the indoor unit level on a strong wall that is not subject to vibrations.
- The inlet and outlet ports should not be obstructed: the air should be able to blow all over the room.
- Do not install the unit near a source of heat, steam, or flammable gas..
• Install the unit near an electric socket or private circuit.
- Do not install the unit where it will be exposed to direct sunlight.
• Install the unit where connection between indoor and outdoor unit is as easy as possible.
• Install the unit where it is easy to drain the condensed water.
- Check the machine operation regularly and leave the necessary spaces as shown in the picture.
• Install the indoor unit where the filter can be easily accessible.

UnicalAir UND A 12H - INDOOR UNIT - 1

text_image insulating covering electrical connections sleeve condensed water drain pipe 40 50 70

minimum spaces to be left (mm)
UnicalAir UND A 12H - INDOOR UNIT - 2

text_image 200 100 600 600 100

OUTDOOR UNIT

  • Do not install the outdoor unit near sources of heat, steam or flammable gases.
  • Do not install the unit in too windy or dusty places.
  • Do not install the unit where people often pass.
  • Select a place where the air discharge and operating sound level will not disturb the neighbours.
  • Avoid installing the unit where it will be exposed to direct sunlight (otherwise use a protection, if necessary, that should not interfere with the air flow).
  • Leave the spaces as shown in the picture for the air to circulate freely.
    • Install the outdoor unit in a safe and solid place.
  • If the outdoor unit is subject to vibration, fix rubber gaskets onto it.

OUTDOOR UNIT CONDENSED WATER DRAINAGE (only for heat pump models)

The condensed water and the ice formed in the outdoor unit during heating operation can be drained away through the drain pipette.

Installation: fasten the drain pipette in the 25 mm hole placed in the lower part of the unit as shown in the picture.

Connect the condensed water hose and the pipette. Pay attention that water is drained in a suitable place.

UnicalAir UND A 12H - OUTDOOR UNIT CONDENSED WATER DRAINAGE (only for heat pump models) - 1

text_image OUTDOOR UNIT

2 INSTALLATION OF THE INDOOR UNIT

WALL HOOK BRACKET

UnicalAir UND A 12H - WALL HOOK BRACKET - 1

text_image 40 50 70

UnicalAir UND A 12H - WALL HOOK BRACKET - 2

text_image indoor outdoor 5 mm

Installation of the wall hook bracket

  1. By using a level, put the wall hook bracket in a perfect square position, both vertically and horizontally
  2. Fix the bracket first with 5 screws.
  3. Use several more tapping screws to secure the bracket onto the wall with even pressure on the screws.
  4. Cut a hole in the wall for the piping and electric connection.

N.B.

Drill a hole in the wall with the outdoor side 5-10 mm lower than the inner side, in order to have a good drain flow.

Note: The shape and dimensions of the wall hook bracket could be modified without prior notice.

NOTE : Maintain the drain pipe in the lower part of the wall hole, or leakage may occur.

Refrigerant piping connection

The piping can be run in the 5 directions indicated by numbers 1, 2, 3, 4, 5 in the figure. When the piping is run in direction 1, 2, 4 or 5, cut a notch along the groove on the side of the indoor unit with a cutter.

Run the piping in the direction of the wall hole and bind the copper pipes, the drain pipe and the power cables together with the tape with the drain pipe at the bottom, so that water can flow freely.

Indoor unit installation

  1. Run the bound pipe and cables through the wall hole and mount the indoor unit onto the upper part of the wall hook bracket securely
  2. Arrange the pipes and cables well.
  3. Push the lower part of the indoor unit tight against the wall hook bracket.

NOTE:

  • Do not bend or crush the indoor unit piping. Avoid sharp bends with radius of curvature of less than 10 cm.
  • Do not bend the same part of the pipe too often, after three times it could be throttled.
  • Do not remove the flare nut from the indoor unit piping until immediately before connecting the connection pipe.

UnicalAir UND A 12H - NOTE: - 1

text_image 1 2 3 4 5

The piping run towards the right
UnicalAir UND A 12H - NOTE: - 2

natural_image Diagram of a car air conditioner unit with cooling fins and attached tubing (no text or labels)

UnicalAir UND A 12H - NOTE: - 3

text_image wall hook bracket

UnicalAir UND A 12H - NOTE: - 4

text_image refrigerant pipe insulation sleeve power cable insulation pipes signal cable refrigerant pipe condensed water drain pipe

3 INDOOR UNIT CONDENSED WATER DRAINAGE

The indoor unit condensed water drainage is fundamental for the success of the installation.

  1. Install the drain hose at the bottom of the wall hole.
  2. The insulator of the copper pipes should be at least 6 mm thick.

UnicalAir UND A 12H - The indoor unit condensed water drainage is fundamental for the success of the installation. - 1

natural_image Diagram showing two pipe connection scenarios with a pipe and water droplets (no text or symbols)

UnicalAir UND A 12H - The indoor unit condensed water drainage is fundamental for the success of the installation. - 2

natural_image Diagram of a pipe or tube inserted into a brick wall, showing fluid flow direction (no text or labels)

YES NO NO

Check that:

  • The top and bottom hooks of the indoor unit are hooked firmly on the wall hook bracket.
  • The unit is positioned horizontally. If the unit is not installed properly, water will drip onto the floor.
  • The drain hose has the correct gradient (at least 3 cm for every meter in length).
  • The drain hose remains at the bottom of the wall hole.

4 OUTDOOR UNIT INSTALLATION

The outdoor unit should be installed on a solid wall and fastened securely

The following procedure must be observed before connecting the pipes and electric cables:

  • decide which is the best position on the wall and leave enough space to be able to carry out maintenance easily.
  • fasten the support to the wall using screw anchors which are particularly suited to the type of wall;
  • use a larger quantity of screw anchors than normally required for the weight they have to bear: during operation the machine vibrates and has to remain fastened in the same position for years without the screws becoming loose.

ATTENTION: ONLY ACR copper pipes for air conditioners are allowed

Connecting the pipes

  • Do not remove the cap from the pipe until connecting it, to avoid dampness or dirt from entering.
  • If the pipe is bent or pulled too often, it will become stiff. Do not bend the pipe more than three times at one place.
  • When extending the rolled pipe, straighten the pipe by unwinding it gently as shown in the figure below

CONNECTIONS TO THE INDOOR UNIT

  • Shape the connection pipe following the diagram.
  • Remove the indoor unit pipe cap (check that there is no debris inside).
  • Insert the flare nut and create a flange at the extreme end of the connection pipe.
  • Connect the pipes by using two wrenches.

CONNECTIONS TO THE OUTDOOR UNIT

Screw the flare nuts to the outdoor unit coupling with the same tightening procedures described for the indoor unit.

UnicalAir UND A 12H - CONNECTIONS TO THE OUTDOOR UNIT - 1

text_image YES NO connection pipes flare nuts liquid tap gas tap indoor unit gas valve service port nut tap protection caps liquid valve tap

To avoid leakage, pay particular attention to the following points:

  • Tighten the flare nuts using two wrenches. Pay attention not to damage the pipes.
  • If the tightening torque is not sufficient, there will probably be some leakage. With excessive tightening torque there will also be some leakage, as the flange could be damaged.
  • The surest system consists in tightening the connection by using a fix wrench and a torque wrench: in this case use the following table.

FLANGE CONNECTION TIGHTENING TORQUE

Pipe Tightening torque Corresponding stress[N x m] (using a 20 cm wrench)
6,35 mm ( ^1/_4 ")15 - 20 wrist strength
9,52 mm ( ^3/_8 ")31 - 35 arm strength
12,70 mm ( ^1/_2 ")50 - 55arm strength
15,88 mm ( ^3/_8 ")65 - 70arm strength

TIGHTENING TORQUE FOR PROTECTION CAPS

Tightening torque[N x m]
Service port nut 7 - 9
Protection caps 25 - 30

To empty the refrigerant pipe from air and humidity, the use of the vacuum pump is recommended.

UnicalAir UND A 12H - CONNECTIONS TO THE OUTDOOR UNIT - 2

text_image torque wrench

UnicalAir UND A 12H - CONNECTIONS TO THE OUTDOOR UNIT - 3

text_image Service port nut

IMPORTANT : REFRIGERANT LEAKAGE INSPECTION

After connecting the piping, check the joints for refrigerant leakage with leak detector carefully.

INFORMATION FOR THE INSTALLER

MODEL7000-9000 BTU/h12000 BTU/h
Liquid pipe diameter1/4"1/4"
Gas pipe diameter3/8"1/2"
Maximum lenght of pipe with standard charge5 m5 m
Maximum distance between indoor and outdoor unit15 m15 m
Additional gas charge25 g/m25 g/m
Maximum difference in level between indoor and outdoor unit (1)5 m5 m
Type of refrigerant**

* refer to the data sticker sticked the outdoor unit
(1) ATTENTION: In case the outdoor unit has been installed higher than the indoor unit, it is necessary to provide "S" oil traps (or liquid separator) to both refrigerant pipes, over 2 m of difference in level.

6 ELECTRICAL CONNECTIONS

INDOOR UNIT 7000 - 9000 - 12000 BTU/h

  1. Lift the front panel.
  2. Take off the cover as indicated in the figure.
  3. Connect the cable wires to the screw terminals by following the numbering.

Use wire size suitable to the electric power input (see name plate on the unit) and according to all current national safety code requirements.

UnicalAir UND A 12H - INDOOR UNIT 7000 - 9000 - 12000 BTU/h - 1

natural_image Technical line drawing of a device interior showing internal components and wiring (no text or symbols)

OUTDOOR UNIT 7000 - 9000 - 12000 BTU/h

  1. Take the cover away.
  2. Connect the cable wires to the terminal board using the same numbering as in the indoor unit.
  3. Fasten the cables with a cable-clamp.
  4. Replace the covers again.

UnicalAir UND A 12H - OUTDOOR UNIT 7000 - 9000 - 12000 BTU/h - 1

text_image screw Remove the cover

N.B.: The unit must be connected to the power supply system through an onnipolar switch (3 mm distance). In case the power supply cable is damaged, it must be replaced by the manufacturer or qualified staff.

INFORMATION FOR THE INSTALLER

MODELLO 18000 BTU/h 24000 BTU/hLiquid pipe diameter 1/4" 3/8"
Gas pipe diameter 1/2" 5/8"
Max. pipe length with standard charge 4 m 4 m
Max. distance between indoor and outdoor unit15 m15 m
Gas supplementary charge 50 g/m 50 g/m
Max. difference in level between indoor and outdoor unit5 m 5 m
Refrigerant type * *

* Always refer to the technical data label on the outdoor unit

6 ELECTRICAL CONNECTIONS

INDOOR UNIT 18000 - 24000 BTU/h

UnicalAir UND A 12H - INDOOR UNIT 18000 - 24000 BTU/h - 1

text_image Technical diagram showing two steps of installing or adjusting a device panel, with Chinese labels indicating components and assembly.
  1. Lift the front panel.

  2. Take off the cover as indicated in the figure.

  3. Connect the power cable wires to the screw terminals by following the numbering and insert the signal cable connector (for heat pump version only).

UnicalAir UND A 12H - INDOOR UNIT 18000 - 24000 BTU/h - 2

natural_image Technical line drawing of a mechanical component with internal components (no text or symbols)

OUTDOOR UNIT 18000 - 24000 BTU/h

  1. Take the cover away.
  2. Connect the signal cable connector (only for heat pump version).
  3. Connect the power cable wires to the terminal board using the same numbering as in the indoor unit.
  4. Fasten the cables with a cable-clamp.
  5. Replace the covers again.

UnicalAir UND A 12H - OUTDOOR UNIT 18000 - 24000 BTU/h - 1

natural_image Diagram showing airflow or ventilation between two air conditioning units, with arrows indicating direction of movement (no text or labels present)

unscrew and take off the front panel

CONNECTION WIRING DIAGRAM FOR MODELS

R410a 7000 - 9000 - 12000 BTU/h

UnicalAir UND A 12H - R410a 7000 - 9000 - 12000 BTU/h - 1

text_image INDOOR UNIT to PCB GND POWER SUPPLY ALIMENTAZIONE 230V-50Hz OUTDOOR UNIT N 2 4 5

CONNECTION WIRING DIAGRAM FOR MODELSDUAL SPLIT

UnicalAir UND A 12H - CONNECTION WIRING DIAGRAM FOR MODELSDUAL SPLIT - 1

text_image UNITÀ INTERNA "A" INDOOR UNIT "A" UNITÀ "A" UNIT "A" UNITÀ "B" UNIT "B" UNITÀ INTERNA "B" INDOOR UNIT "B" UNITÀ ESTERNA OUTDOOR UNIT CODICE CLI_04_0042 POWER SUPPLY ALIMENTAZIONE 230 V 50 Hz

Connect the power cable wires to the screw terminals by following the numbering; ensure that a properly sized and connected ground wire is in a place.

CONNECTION WIRING DIAGRAM FOR MODELS

18000 BTU/h (heat pump)
UnicalAir UND A 12H - CONNECTION WIRING DIAGRAM FOR MODELS - 1

text_image INDOOR UNIT to PCB GND POWER SUPPLY ALIMENTAZIONE 230V-50Hz OUTDOOR UNIT N 2 4 5

24000 BTU/h (heat pump)
UnicalAir UND A 12H - CONNECTION WIRING DIAGRAM FOR MODELS - 2

text_image INDOOR UNIT GND POWER SUPPLY ALIMENTAZIONE 230V-50Hz OUTDOOR UNIT N 2 3 4 5 GND GND

Connect the power cable wires to the screw terminals by following the numbering.

7

FINAL STAGES

  1. Wind insulating covering around the joints of the indoor unit and fix it with insulating tape.
  2. Fix the exceeding part of the signal cable to the piping or to the outdoor unit.
  3. Fix the piping to the wall (after having coated it with insulating tape) using clamps or insert them into plastic slots.
  4. Seal the hole in the wall through which he piping is passed so that no air or water can filter.

INDOOR UNIT TEST

☐ Do the ON/OFF and FAN keys operate normally?
□ Does the MODE key operate normally?
☐ Do the set point and TIMER keys function properly?
□ Does each lamp light normally?
☐ Do the louvers for air flow direction operate normally?
☐ Is the condensed water drained regular?

OUTDOOR UNIT TEST

☐ Is there any abnormal noise or vibration during operation?
□ Could the noise, the air flow or the condensed water drainage disturb the neighbours?
□ Is there any coolant leakage?

UnicalAir UND A 12H - OUTDOOR UNIT TEST - 1

text_image insulating covering piping insulating tape

UnicalAir UND A 12H - OUTDOOR UNIT TEST - 2

text_image clamps piping

UnicalAir UND A 12H - OUTDOOR UNIT TEST - 3

text_image gasket (outdoor)(indoor) wall DOC

NOTE: The electronic controller allows the compressor to start only three minutes after voltage has reached the system.

UnicalAir UND A 12H - OUTDOOR UNIT TEST - 4

After installation, explain the correct operation to the Customer using the Instruction Handbook. Let the Customer keep this installation handbook because it may be referred to when the air conditioner is serviced or moved.

natural_image Technical line drawing of a mechanical component with no visible text or symbols

UnicalAir UND A 12H - OUTDOOR UNIT TEST - 5

text_image dima

UnicalAir UND A 12H - OUTDOOR UNIT TEST - 6

natural_image Technical line drawing of a mechanical component with no visible text or symbols

UnicalAir UND A 12H - OUTDOOR UNIT TEST - 7

natural_image Technical line drawing of a mechanical component with wires and a central connector (no text or symbols)

UNITÀ ESTERNA 7000 - 9000 - 12000 BTU/h

text_image Hand-drawn diagram showing a hand using a tool to adjust or install a component, with numbered parts and Chinese labels.
natural_image Hand inserting a component into a device (no text or symbols visible)

UnicalAir UND A 12H - UNITÀ ESTERNA 7000 - 9000 - 12000 BTU/h - 1

natural_image Technical line drawing of a mechanical component with internal components and an arrow indicating direction (no text or symbols)

UNITA' ESTERNA 18000 - 24000 BTU/h

text_image coperchio

SCHEMA ELETTRICO DI COLLEGAMENTO PER MODELLI R410a 7000 - 9000 - 12000 BTU/h

UnicalAir UND A 12H - SCHEMA ELETTRICO DI COLLEGAMENTO PER MODELLI R410a 7000 - 9000 - 12000 BTU/h - 1

text_image INDOOR UNIT to PCB GND POWER SUPPLY ALIMENTAZIONE 230V-50Hz OUTDOOR UNIT N 2 4 5

SCHEMA ELETTRICO DI COLLEGAMENTO PER MODELLI DUAL SPLIT R410A
UnicalAir UND A 12H - SCHEMA ELETTRICO DI COLLEGAMENTO PER MODELLI R410a 7000 - 9000 - 12000 BTU/h - 2

text_image UNITÀ INTERNA "A" INDOOR UNIT "A" UNITÀ "A" UNIT "A" UNITÀ "B" UNIT "B" UNITÀ INTERNA "B" INDOOR UNIT "B" UNITÀ ESTERNA OUTDOOR UNIT CODICE CLI_04_0042 POWER SUPPLY ALIMENTAZIONE 230 V 50 Hz
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : UnicalAir

Model : UND A 12H

Category : Air-conditioner