IFM E43924 - Grinding tool accessory

E43924 - Grinding tool accessory IFM - Free user manual and instructions

Find the device manual for free E43924 IFM in PDF.

📄 8 pages English EN Download 💬 AI Question
Notice IFM E43924 - page 1
View the manual : Français FR Deutsch DE English EN
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about E43924 IFM

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Grinding tool accessory in PDF format for free! Find your manual E43924 - IFM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. E43924 by IFM.

USER MANUAL E43924 IFM

Operating instructions

Grinding protection set for G1/2 hygienic welding

adapter

E43924

Contents

1 Preliminary note 3

1.1 Symbols used 3
1.2 Warnings.... 3

2 Safety instructions.... 4

3 Intended use.... 5
4 Installation.... 6

4.1 Installation of E43924 on the special welding adapter E43919 6
4.2 Processing of the weld seam for special welding adapters 6

5 Disposal 8

1 Preliminary note

You will find instructions, technical data, approvals and further information using the QR code on the unit / packaging or at documentation.ifm.com.

1.1 Symbols used

√ Requirement
Instructions
Reaction, result

[...] Designation of keys, buttons or indications

→ Cross-reference

IFM E43924 - Symbols used - 1

Important note

Non-compliance may result in malfunction or interference.

IFM E43924 - Symbols used - 2

Information

Supplementary note

1.2 Warnings

Warnings indicate the possibility of personal injury and damage to property. This enables safe product handling. Warnings are graded as follows:

IFM E43924 - Warnings - 1

WARNING

Warning of serious personal injury

▷ If the warning is not observed, fatal and serious injuries are possible.

IFM E43924 - Warnings - 2

CAUTION

Warning of minor to moderate personal injury

▷ If the warning is not observed, minor to moderate injuries are possible.

ATTENTION

Warning of damage to property

▷ If the warning is not observed, damage to property is possible.

2 Safety instructions

  • Read this document before setting up the product and keep it during the entire service life.
  • The product must be suitable for the corresponding applications and environmental conditions without any restrictions.
  • Only use the product for its intended purpose (→ Intended use).
  • If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property may occur.
  • The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator.
  • Installation, set-up, operation and maintenance of the product must be carried out by qualified personnel authorised by the machine operator.

3 Intended use

The grinding protection set provides protection for the transition area for the special adapter E43919 when reworking the weld seam.

IFM E43924 - Intended use - 1

1: M12 nut
2: High hemisphere D = 70
3: Protective cable entry
4: Flat half shell D = 70
5: M12 screw

IFM E43924 - Intended use - 2

One set of the E43924 is for one-time use.

4 Installation

ATTENTION

Dangers for the plant and environment during rework.

▶ Consider possible dangers and adhere to applicable regulations and guidelines.

IFM E43924 - Installation - 1

WARNING

Dangers for persons during rework.

▶ Consider possible dangers and adhere to applicable regulations and guidelines.

The grinding protection must be centred on both sides before final tightening.

Do not scratch the surfaces with the grinding protection caps.

One grinding protection set is for one-time use.

4.1 Installation of E43924 on the special welding adapter E43919

▶ Install the grinding protection E43924 on the welded adapter E43919.

IFM E43924 - Installation of E43924 on the special welding adapter E43919 - 1

1: High hemisphere D = 70
2: M12 nut
3: M12 screw
4: Protective cable entry
5: Welding adapter E43919
6: Flat half shell D = 70

4.2 Processing of the weld seam for special welding adapters

Observe and use protective devices and equipment according to the product specifications, installation conditions and ambient conditions.
Observe and use the operating instructions and safety instructions for the tools used.

Do not remove any material from the special welding adapter in the transition area.

▶ Guide the grinding tool parallel to the surface to be processed.

IFM E43924 - Processing of the weld seam for special welding adapters - 1

Fig. 1: Schematic illustration, components may vary.

5 Disposal

▶ After use dispose of the product or components in an environmentally friendly way in accordance with the applicable national regulations.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : IFM

Model : E43924

Category : Grinding tool accessory