Freedom Par H9 IP X4 - Lamp Chauvet - Free user manual and instructions
Find the device manual for free Freedom Par H9 IP X4 Chauvet in PDF.
User questions about Freedom Par H9 IP X4 Chauvet
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Lamp in PDF format for free! Find your manual Freedom Par H9 IP X4 - Chauvet and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Freedom Par H9 IP X4 by Chauvet.
USER MANUAL Freedom Par H9 IP X4 Chauvet
text_image
QR code image containing encoded data, no visible human-readable textScan the QR code to access the product page, warranty terms, and the complete User Manual

natural_image
Line drawing of a multi-chamber air conditioner unit with control panel and fan (no text or symbols)Intentionally Left Blank Page
Safety Notes
These Safety Notes include important information about installation, use, and maintenance of Freedom Par H9 IP x4.
■ ALWAYS:

◆ Connect to a grounded circuit.
- Connect to operating voltages as specified on the product's spec sticker.
♦ Disconnect from power before replacing the fuse.
♦ Disconnect from its power source during periods of inactivity.
◆ Use a safety cable when suspending overhead.
- Heed all restrictions and warnings on the spec sticker.
◆ Mount in a location with at least 20 in (50 cm) of ventilation.
♦ Replace the fuse with the same type and rating.
Use a clamp with a captive bolt when a single hanging bracket is used.
■ In the event of a serious operating problem, stop using immediately.
■ DO NOT:
◆ Open this product or attempt any repairs. It contains no user-serviceable parts.
◆ Look at the light source when the product is on.
◆ Use if the power cord is crimped or damaged.
♦ Disconnect by pulling on the power cord.
◆ Allow flammable materials close to the product when it is operating.
♦ Touch the housing when it is on.
◆ Block any ventilation holes/slots in the housing.
◆ Connect to a dimmer or rheostat.
♦ Carry the product by its power cord.
◆ Operate in temperatures higher than 104°F (40°C).
♦ Expose to environments that exceed the Ingress Protection (IP) rating.
♦ Expose to rain or moisture.
Use outdoors.
Submerge.
Leave outdoors for extended periods of time.
♦ Set this product on a flammable surface.
♦ Expose to corrosive environmental conditions such as temperature, humidity, salinity, pressure, radiation, or shock.
FCC Compliance
This device complies with Part 15 Part B of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
What is Included
◆ 4 Freedom Par H9 IP products
◆ 4 magnetic diffusers
Carry bag
♦ RFC
♦ Multi-charger
Power cable
◆ Quick Reference Guide
Battery Charge Notes
Rechargeable lithium-ion batteries are potentially hazardous and can present a serious FIRE HAZARD, SERIOUS INJURY and/or PROPERTY DAMAGE if damaged, defective, or improperly used.
■ ALWAYS:
◆ Charge using a manufacturer-provided charger while the product is powered off.
◆ Charge the battery in temperatures between 32°-95°F (0°-35°C).
Allow a depleted battery to charge for a few minutes before turning on the product. If the battery is completely discharged, the device cannot be turned on immediately when the charger is connected.
♦ Keep at least 3 ft (1 m) distance to any heat source and away from flammable materials.
- Keep the lid of any charging case open while charging.
♦ Keep batteries away from children.
◆ Store batteries between 40-60% charge.
◆ Follow local regulations when disposing of batteries.
◆ Replace with an authentic Chauvet battery.

■ DO NOT:
◆ Continue charging if the battery becomes hot, smokes, swells, or gives off an odor during charging.
Leave the product unattended while charging.
◆ Deplete the battery below 10%.
◆ Charge the battery in a closed container.
◆ Charge for more than 24 hours.
Control Panel Description
| Button Function | |
| Exits from the current menu or function | |
| Navigates upwards through the menu list and increases the numeric value when in a function | |
| Navigates downwards through the menu list and decreases the numeric value when in a function | |
| Enables the currently displayed menu or sets the currently selected value into the selected function | |
Notas de seguridad
Intentionally Left Blank Page
Contact Us
General Information Technical Support
Chauvet World Headquarters
Address: 3360 Davie Rd. Voice: (844) 393-7575
Davie, FL 33314 Fax: (954) 756-8015
Voice: (954) 577-4455 Email: chauvetcs@chauvetlighting.com
Fax: (954) 929-5560
Toll Free: (800) 762-1084 Website: www.chauvetdj.com
Chauvet U.K.
Address: Unit 1C Email: UKtech@chauvetlighting.eu
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK Website: www.chauvetdj.eu
NG16 6NT
Voice: +44 (0) 1773 511115
Fax: +44 (0) 1773 511110
Chauvet Benelux
Address: Stokstraat 18 Email: BNLtech@chauvetlighting.eu
9770 Kruishoutem
Belgium Website: www.chauvetdj.eu
Voice: +32 9 388 93 97
Chauvet France
Address: 3, Rue Ampère
91380 Chilly-Mazarin
France Website: www.chauvetdj.eu
Voice: +33 1 78 85 33 59
Chauvet Germany
(Entrance by Calle 2)
Zona Industrial Lerma
Visit the applicable website above to verify our contact information and instructions to request support. Outside the U.S., U.K., Ireland, Mexico, France, Germany, or Benelux, contact the dealer of record.
Freedom Par H9 IP x4 QRG ML6 Rev. 1
© Copyright 2022 Chauvet
All rights reserved



RoHS