CATA THALASSA 900 GWH - Doorbells

THALASSA 900 GWH - Doorbells CATA - Free user manual and instructions

Find the device manual for free THALASSA 900 GWH CATA in PDF.

📄 29 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice CATA THALASSA 900 GWH - page 9
View the manual : Français FR Deutsch DE English EN Español ES Português PT
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypeRange hood
BrandCATA
ModelTHALASSA 900 GWH
CategoryDoorbell (reclassified from manual: kitchen hood)
Power supplyElectric, mains 220-240 V
Motor powerNot specified in manual (estimated: 200-300 W)
Dimensions (W x D x H)Not specified in manual (standard estimate: 900 x 500 x 600 mm)
WeightNot specified in manual (estimate: 15-20 kg)
Speeds5 speeds + Boost function (temporary full power)
LightingLED, adjustable intensity from L1 to L5, choice of cold or warm light
TimerGradual automatic shutdown up to 15 minutes max (5 min at Boost then 2 min per descending speed)
Special functionsRenova Air (runs 10 min/hour), Renova Turbo (automatic cleaning cycle), connectivity with hob
Extraction modeExtraction or recirculation (with charcoal filter)
FiltersWashable metal filters, charcoal filters (reusable or disposable)
Filter maintenanceRegular cleaning of metal filters; replacement or cleaning of charcoal filters depending on type
DisplayLED, indicates speed, mode and alerts (clogged filter)
Remote controlCompatible with already paired remote control
SafetyAutomatic shutdown after 5 min in Boost; motor stop by long press on speed decrease
WarrantyNot specified in manual (standard 2 years)
Customer serviceContact technical service or the distributor in case of persistent failure

Frequently Asked Questions - THALASSA 900 GWH CATA

How to turn on the hood and adjust the speed?
Press the speed decrease icon () to start at speed 1. Use the increase icon () to switch to Boost mode (full power). To reduce speed, press ; a long press (>2s) stops the motor but leaves the lighting on.
How to activate the Boost function?
Press the speed increase icon () for more than two seconds, regardless of the current speed. The display flashes and the hood operates at full power for a maximum of 5 minutes, then returns to speed 5.
How to set the timer?
With the motor on, press the timer icon (). The icon flashes red and the current speed is maintained for 5 minutes, then decreases by one step every 2 minutes until stop. Press again to cancel the cycle.
How to change the brightness or color temperature of the lighting?
Press and hold the lighting icon () to scroll through levels L1 to L5. Release when the desired brightness is reached. To change the temperature (cold/warm), enter settings mode by turning off the hood, then press and simultaneously. Then press the lighting icon () to choose between cold light (_) or warm light (≡).
How to switch from extraction mode to recirculation mode?
Turn off the hood, then press and simultaneously to enter settings mode. Press the timer icon () which turns red. Use or to select the mode: extraction (—) or recirculation ( ). Press to confirm.
What to do if the timer icon flashes red and displays ( — )?
It is the filter cleaning alert. Clean or replace the filters (metal and/or charcoal). Once done, touch the timer icon () to turn off the indicator.
How to use the Renova Air function?
With the hood off, press the timer icon (). A flashing 'H' appears: the hood will automatically run for 10 minutes every hour. To exit, press again.
How to activate the Renova Turbo function?
With the hood off, press and hold the timer icon () and the increase icon () simultaneously for 3 seconds. The screen displays '≡' and the hood follows a cycle: 5 min at speed MAX, 3 min at speed 5, 3 min at speed 4, etc., until stop. To exit before the end, press the lighting icon ().
What to do if the hood vibrates excessively?
Check that the appliance is correctly installed and fixed to the supports. If the fan blade is damaged or the motor is not properly fixed, contact technical service.
How to connect the hood to a compatible hob?
Enter settings mode (hood off, press and simultaneously). Then press the timer () and lighting () icons at the same time. The screen flashes 'A' while waiting for the signal from the hob. Once the signal is received, the screen displays a steady 'A': connection successful. The hood will then automatically follow the hob's commands.

User questions about THALASSA 900 GWH CATA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Doorbells in PDF format for free! Find your manual THALASSA 900 GWH - CATA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. THALASSA 900 GWH by CATA.

USER MANUAL THALASSA 900 GWH CATA

natural_image Two-panel image showing a black panel with textured edges and a white panel with a light edge, both without any visible text or symbols.

EN IMPORTANT - Please read carefully the separate safety guide before use.

WARNING: Read the instructions before using the appliance

FUNCTIONS & SETTINGS

CONTROL PANEL

To obtain the best results from your cooker hood it is recommended that you leave it switched on for a short time after you have finished cooking.

CATA THALASSA 900 GWH - CONTROL PANEL - 1Timer
CATA THALASSA 900 GWH - CONTROL PANEL - 2ON, Fan Boost Function and Fan speed increase
[HDWR]LED display
[XOZR]OFF and Fan speed decrease
CATA THALASSA 900 GWH - CONTROL PANEL - 3Light ON /OFF

SETTINGS

Once the appliance is switched off press both, increase (↑) and decrease fan speed (↓) icons. All icons will start blinking in White. The hood is now in setting mode.

CATA THALASSA 900 GWH - SETTINGS - 1

IMPORTANT: Once in settings mode, you can adjust the recirculation and lighting ions in any order. However, all actions must be completed within two minutes.

SETTING THE DUCTED OR RECIRCULATION MODE

Once in setting mode, press the Timer (💡) icon and it will blink in red. The LED display will show the current Ducted or Recirculation mode.

Ducted mode: (−) Default setting to extract air to the outside.

Recirculation mode: (≡) Setting to recirculate the air with carbon filters installed.

To change this option press either (↓) or (↑) to select the correct mode and then press Timer(💡) icon to accept the change.

SETTING THE LIGHTING MODE

Once in setting mode, press the Light (💡) icon and it will blink in red. The LED display will show the current lighting mode.

EN

Cool light: (_) Default setting for all lights.

Warm light: (≡) Optional setting for all lights.

To change these settings press (↓) or (↑) and press the Light (○) icon to accept the change.

SETTING CONNECTIVITY MODE

Once in setting mode, press both, the Timer ( ) and the Light ( ) icons. The led display will show (A) blinking waiting hob's signal. Once it receive it, the led display will show (A) fixed.

Note: If the hood controls are manually overridden when the hob and hood are linked, the hood will operate for 5 minutes on this manual setting before returning to control by de hob.

Note: The remote control supplied will already be paired to your ceiling hood.

GENERAL USE

ON/OFF AND INCREASE/DECREASE THE FAN SPEED

Press the decrease fan speed (↓) icon and the fan will turn on at speed 1.

Press the increase fan speed icon (↑) and the fan will turn on at maximum speed (Booster)

If the fan motor is set at speeds 2,3,4, 5 or P, pressing the Fan Decrease (↓) Icon will reduce the speed by one level at a time. If you press the Fan Decrease (↓) Icon for more than three seconds, the fan will turn down. However, the downlight will remain on 8 if enabled).

If the fan motor is set at speed 1, pressing the Fan Decrease ( ↓) Icon the motor will switch off. However, the downlight will remain on (if enabled) and the display will show the current brightness level.

Boost Function

If the fan motor is set at speeds 1,2,3,4 or 5, pressing the Fan Increase (↑) Icon will increase the speed by one at a time. If you press the Fan Increase (↑) Icon for more than two seconds, the speed will increase to full power from any level and the display will flash “P”

NOTA: Full power or Boost (P) only operates for five minutes maximum to conserve energy and the fan speed will automatically drop to speed level 5 after this time.

Light On/Off ( )

Touch the Light ( ) Icon to turn on the downlight.

To change the brightness of the downlight, touch and hold the Light (💡) Icon until the display show the brightness sequence. Remove your finger from the Light (💡) Icon when the desired brightness is achieved. The sequence runs from L1 to L5 and back to L1 in steps. The selected brightness will flash for a few seconds and revert to the fan speed display. This lighting setting will be kept for future uses.

Setting the timer ( ⏰ )

  • When the fan motor is on and the Timer ( √ ), icon is pressed the icon will turn in red and the display will show the current fan speed.
  • The chosen speed level will remain in use for five minutes before dropping down to the next lowest speed. This speed will remain in operation for two minutes before dropping down again. This will be repeated every two minutes unless the speed is already at level 1 and then the fan will turn off. If the light is already on, this will also be turned off.
  • Pressing the Fan Decrease ( ) Icon or Fan Increase ( ↑ ) Icon during a current timer program will restart the countdown process again with the first five minutes cycle.
  • If the Timer ( √ ) icon is pressed again during a current timer program, the cycle will be cancelled. The Timer ( √ ) Icon will revert to white and the current fan speed will remain on indefinitely.
  • The maximum timer program cycle is 15 minutes: 5 minutes: 5 minutes on 0 and then 2 minutes each on speed 5 down to speed 1.

RENOVA AIR FUNCTION (This function is not available on all models)

Press the timer button (💡) with the hood switched off. A flashingH will appear. You will have activated Renova Air mode. The hood will operate automatically for 10 minutes every hour. In idle mode, a flashingIcon will appear for 1 hour. With this mode activated, the hood can be used as normal. To exit this mode, press the timer button (💡) within the function.

RENOVA TURBO FUNCTION

With the hood switched off. Press and hold the timer and increase speed buttons (💡) at the same time for 3 seconds.

A permanent icon will appear on the display. You have activated the Renova Turbo function.

EN

The icon will start to flash from bottom to top while this function is activated.

At this time, the hood will continue with the following sequence automatically:

  • 5 minutes at MAX speed
  • 3 minutes at 5th speed
  • 3 minutes at 4th speed

This sequence will continue down to the first speed. Once the time has come to an end, the hood will stop.

To exit this mode before it ends, press the timer icon (💡).

During Renova mode, the hood can be used as normal by pressing the (↑) or (↓) icons.

The speed of the Renova function can be increased (↑) or (↓) decreased by pressing the or icons. The Renova

function will automatically continue with the sequence described above from the selected speed.

Filter cleaning warning

Once the cooker hood is off, if the Timer icon (☑) blinks in red and LED display shows “(−)”, you should clean the filters. Once they are cleaned or replaced, press the Timer (☑) icon again and the icon will turn off.

(Only in Recirculation mode). Once the cooker hood is off, if Timer (💡) icon blinks in red and the LED display shows “(≡)” , you should clean the carbon filters (in case you are using washable carbon filters) or replace them ( in case you are using disposable carbon filters). Once they are cleaned or replaced, press the Timer (💡) icon again and the icon will turn off.

Problem Possible cause Solution
Excessive vibration. The appliancece is not installed properly on the brackets.Take down the appliance and check it is properly fixed.
The fan blade is damaged. Switchch off the appliance. Repair to be carried out by qualified service personnel only.
The fan motor is not fixed tightly.
The light is on, but the fan does not work.The fan blade is jammed.
The motor is damaged.
Both the light and motor do not work.Light bulb blown. Contact Customer Services on.
Power connection loose. Check power supply.
Suction performance reduced.Speed may be too low. Select a higher speed.
Optional vent kit might be twisted.Ensure that the vent kit is fitted according to the manufacturer's instructions.
Top vent might be obstructed.Clear any obstruction.
The installation may not comply with the manufacturers instructions.The vent hose should be correct diameter throughout with no reductions or restriction. (See installation section).
Works normally but cooking smells linger.Carbon filter is not fitted in recirculation mode or is full of grease.Fit carbon filter or replace the carbon filter (See Care and maintenance section).
The hood does not work Checkthat the hood is connected to power. Check that the fuses or automatic have not jumped.
The hood still does not workIf, after having checked the points mentioned above, your problem has not yet been solved, contact the technical service or your distributor.

CATA THALASSA 900 GWH - Filter cleaning warning - 1

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : CATA

Model : THALASSA 900 GWH

Category : Doorbells