Fysic FC-18 - Ultrasonic cleaner

FC-18 - Ultrasonic cleaner Fysic - Free user manual and instructions

Find the device manual for free FC-18 Fysic in PDF.

📄 34 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Fysic FC-18 - page 11
Pick your language and provide your email: we'll send you a specifically translated version.
Brand Fysic
Model FC-18
Product type Ultrasonic cleaner
Tank capacity 350 ml (max)
Ultrasonic frequency 50 kHz
Timer Approximately 5 minutes (auto shut-off)
Supply voltage 230 V
Color White (transparent lid)
Tank material Stainless steel (estimated)
Usage Glasses, jewelry, waterproof watches, gemstones, dentures, etc.
Cleaning liquid Tap water or special cleaning solution
Operation Ultrasonic cavitation
Power indicator Yes (LED)
Maintenance Clean the outside with a damp cloth
Safety Do not use without water; do not touch the liquid during operation

Frequently Asked Questions - FC-18 Fysic

Can you clean glasses with the Fysic FC-18?
Yes, suitable for glasses and frames, but avoid damaged coatings. Do not place in direct contact with the bottom of the tank to avoid scratches.
How much water should be put in the tank?
Fill up to the MAX mark (about 3/4 of the tank, max capacity 350 ml). Never run it empty.
How long does a cleaning cycle last?
The cycle lasts about 5 minutes with automatic shut-off. You can stop it earlier by pressing the on/off button.
Can I use a liquid other than water?
Yes, you can use a special ultrasonic cleaning solution, but do not put flammable or corrosive products directly in the tank. Use a separate glass container.
Is it safe to clean silver jewelry or pearls?
Yes, suitable for gold, silver, gemstones, emeralds, and pearls. Avoid overly fragile items.
Does the device heat up during use?
It is normal for the upper edges of the tank to become hot during prolonged use. Take a 3-minute break between cycles if using the device several times in a row.
How to maintain the ultrasonic cleaner?
Clean the outside with a damp cloth. Do not use chemicals. Empty the tank if you do not use it for a long time.
What to do if the water is very hard?
Use degassed water (boiled, decalcified, or distilled) for best results. Run 3 empty cycles before the first cleaning.
Can I clean watches with the FC-18?
Yes, waterproof watches can be cleaned. Watch out for unscrewed parts or damage.
Is the device guaranteed?
The manual does not mention a warranty, but please contact Fysic or your dealer for more information.

User questions about FC-18 Fysic

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Ultrasonic cleaner in PDF format for free! Find your manual FC-18 - Fysic and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. FC-18 by Fysic.

USER MANUAL FC-18 Fysic

natural_image Line drawing of a rectangular electronic device with a power outlet cable (no text or symbols)

NL

INLEIDING

text_image Diagram of a device with numbered parts and labeled connections, including a power outlet terminal.
natural_image Line drawing of a stainless steel appliance with open lid and internal compartments (no text or symbols)

Specifications: Ultrasonic Cleaner FC-18

Power Supply: 220-240V\~50/60Hz

Power: 30W

Frequency: 50KHz

Tank Capacity: 350ml tot max.

Timer: ± 5 mins

Dimensions: 85×188×97mm

Net Weight: 478g

FR

INTRODUCTION

text_image Diagram of a device with numbered parts and labeled connectors, including a plug terminal.
text_image Diagram showing a hand using a showerhead to stop a shower, crossed out by red prohibition symbols.

EXEMPLES D'OBJETS QUI PEUVENT ÊTRE NETTOYÉS

natural_image Line drawing of a stainless steel appliance with open lid and internal compartments (no text or symbols)

Specifications: Ultrasonic Cleaner FC-18

Power Supply: 220-240V\~50/60Hz

Power: 30W

Frequency: 50KHz

Dimensions: 85×188×97mm

Net Weight: 478g

DE

EINFÜHRUNG

text_image Diagram of a device with numbered parts and labeled connections, including a plug and cable.
text_image Prohibition sign showing a hand using a washing machine with red prohibition symbol
natural_image Line drawing of a portable appliance with open lid and internal compartments (no text or symbols)

Specifications: Ultrasonic Cleaner FC-18

Power Supply: 220-240V\~50/60Hz

Power: 30W

Frequency: 50KHz

Dimensions: 85×188×97mm

Net Weight: 478g

EN

INTRODUCTION

The Fysic FC-18 is an ultrasonic cleaner for the cleaning of e.g. glasses and spectacle frames, jewellery, gemstones, pearls, emeralds, silver wear, waterproof watches, etc. Dirt particles are soaked off by the ultrasonic waves (50KHz) in the water-based (cleaning) liquid or water. Special cleaning fluids are available from regular vendors.

The ultrasonic cleaning principle is based on the implosion of tens of thousands of water vapor bubbles (cavitation) through high-frequency sound waves. You'll also find this type of cleaning adopted by jewellers, opticians, hospitals but also in the industrial sector.

The cleaning is based on regular tap water en ensures cleansing at the deepest level, however it doesn't provide shining or disinfecting.

ULTRASONIC CLEANER OVERVIEW
Fysic FC-18 - INTRODUCTION - 1

text_image Diagram of a device with numbered parts and labeled connectors, including a plug terminal.
  1. Transparentlid
  2. Waterreservoir
  3. Power button to start or stop cleaning
  4. Powerindicator
  5. Mains cable (230V)

SAFETY INSTRUCTIONS

  • The ultrasonic cleaner may only be used with a mains voltage of 230V.
  • Never directly fill the reservoir with flammable or aggressive chemicals (acids, etc.), but use a separate glass container (not included).

- Never reach into the cleaning liquid during the ultrasonic cleaning process.

- Never use the device for cleaning living beings or body parts (fingernails).

- If you've noticed any transportation damage, do not connect the device to the mains.

- Insert heavily polluted objects with the dirty side downwards and don't stack them. You may need to repeat the cleaning process.

- The ultrasonic cleaner may only be used when filled with an adequate amount of water (level 2/3, reservoir approx. 3/4 full, up to the MAX indication).

It's normal for the upper edges of the reservoir to become warm during prolonged use.

Fysic FC-18 - SAFETY INSTRUCTIONS - 1

text_image Diagram showing a hand using a showerhead to clean water, crossed out by red prohibition symbols.

EXAMPLES OF SUITABLE OBJECTS FOR CLEANING

  • Glasses and spectacle frames (avoid direct contact between the spectacle glasses and the bottom of the reservoir to prevent scratching. Put the lenses up). Pay attention to any loose pieces or any damage to the coating of the frame or to the glass. In this case, the coating may be further damaged during the cleaning process.
  • Contact lenses (hard and soft) in combination with multi-purpose no-rub liquid.
    • Gold or silver jewellery, gemstones, emeralds and pearls.
  • Felt-tip pens, ink cartridges and accessories.
  • Dentures, brackets, instruments, etc.
  • Shaving heads of electric razors.
  • Delicate mechanical parts of e.g. clocks or for model building.

OPERATION

  1. Open the lid.
  2. Fill the reservoir with cold water. Minimum 3/4 full up to the "MAX" indicator in the reservoir. Having the FC-18 operate without water or liquid will damage the device.

  3. Place the object you want to clean in the reservoir. You may also use a glass jar or other container. This container must be provided with water or cleaning liquid. In this way, the water in the reservoir stays clean.

  4. Close the lid.

  5. Make sure your hands are dry and insert the plug into the FC-18 and into a wall socket. The power indicator will briefly illuminate to indicate that the device is switched on.

Fysic FC-18 - OPERATION - 1

natural_image Line drawing of a stainless steel appliance with open lid and internal compartments (no text or symbols)
  1. Press the to start or stop button to start cleaning. The ultrasonic cleaner will now start the cleaning process. The indicator remains lit during this process. The device will stop cleaning after approx. 5 minutes. You may press the to start or stop, button to stop the process beforehand. The cleaning process will stop.
  2. Make sure your hands are dry and remove the plug from the wall socket.
  3. Open the lid.
  4. Remove the cleaned object from the water reservoir.
  5. Empty the water reservoir when not in use for a prolonged period of time or when the water is heavily polluted.

INSTRUCTIONS

When filling with fresh tap water, based on the lime content, please keep in mind the degassing time (optimal cleaning results are obtained using degassed water, e.g. boiled, decalcified or distilled). In other cases we recommend you, for degassing the water, to fill the device with water and have it operate for 3 cycles before inserting any objects. When the water hasn't been used for some time, it's recommended to degas the water again.

PROLONGED USE

Keep in mind that when used for a longer period of time (starting the cleaning process multiple times in a row) the water and the reservoir may become warm. In this case, please take a break to allow the water and the reservoir to cool down (we recommend a 3 minutes pause in between cleaning processes). Using the device with the tank being too warm may affect its life span and may loosen the vibration element.

MAINTENANCE

The FC-18 is maintenance free and thus requires no maintenance.

If necessary you may cleaning the exterior with a moist cloth; never use chemical cleaning agents.

Don't place the cleaner on surfaces treated with cellulose; the rubber feet may leave tracks.

ATTENTION

Pay attention while cleaning glasses. An already loosened coating or colour layer on the glass or frame may be further loosened when using the FC-18. When in doubt, don't use the FC-18 for glasses with coating.

Specifications: Ultrasonic Cleaner FC-18

Power Supply: 220-240V\~50/60Hz

Power: 30W

Frequency: 50KHz

Tank Capacity: 350ml till max.

Timer: ± 5 mins

Dimensions: 85×188×97mm

Net Weight: 478g

NO

INTRODUKSJON

text_image Diagram of a device with numbered parts and labeled connections, including a terminal plug.
natural_image Line drawing of a stainless steel appliance with open lid and internal compartments (no text or symbols)
text_image Diagram of a device with numbered parts and labeled connections, including a plug and cable.
text_image Diagram showing a hand using a device to stop a washing machine, with red prohibition symbols indicating no usage.
natural_image Line drawing of a stainless steel appliance with open lid and internal compartments (no text or symbols)

INSTRUKTIONER

text_image Diagram of a device with numbered parts and labeled connections, including a power outlet terminal.
text_image Diagram showing a hand washing a cup with red prohibition symbols
natural_image Line drawing of a stainless steel washing machine with open lid and internal compartments (no text or symbols)
text_image Diagram of a device with numbered parts and labeled connections, including a plug terminal.
text_image Diagram showing a hand using a device to clean or stop, with red prohibition symbols indicating no protection.

ESIMERKKEJÄ SOVELTUVISTA PUHDISTETTAVISTA ESINEISTÄ

natural_image Line drawing of a stainless steel appliance with open lid and internal compartments (no text or symbols)
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Fysic

Model : FC-18

Category : Ultrasonic cleaner