Perel VTBAL601 - Scale

VTBAL601 - Scale Perel - Free user manual and instructions

Find the device manual for free VTBAL601 Perel in PDF.

📄 34 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Perel VTBAL601 - page 3
Pick your language and provide your email: we'll send you a specifically translated version.
Brand Perel
Model VTBAL601
Product type Hanging scale
Maximum capacity 300 kg (661 lb)
Material ABS and steel
Display LCD, 56 x 26 mm
Net weight 785 g
Power supply 3 AA 1.5V batteries (included)
Main functions On/Off, tare, unit conversion, HOLD function (auto hold, peak hold, no hold)
Measurement units kg, lb (and others via UNIT button)
Calibration Possible via key combination (UNIT + ON-OFF)
Warranty 2 years (consumer)
Safety Do not immerse, do not disassemble, use on stable surface
Maintenance and cleaning Clean with a damp cloth; do not use solvents
Spare parts and repairability No user-serviceable parts; return to retailer for repair
General information Follow safety instructions, household use only
Included accessories 3 AA batteries, user manual

Frequently Asked Questions - VTBAL601 Perel

How to turn the scale on and off?
Press the ON-OFF button to turn the scale on or off. The display shows zero when ready.
How to use the tare function?
Place a container or object on the scale, then press the TARE button to reset the display to zero. Then add the item to be weighed.
How to change the weight unit?
Press the UNIT button repeatedly until the desired unit (kg, lb, etc.) appears on the screen.
How does the HOLD function work?
Press the HOLD button to select the mode: A (auto hold) locks the stable weight; P (peak hold) locks the maximum weight; N (no hold) does not lock the weight.
How to calibrate the scale?
Turn off the scale. Press and hold the UNIT and ON-OFF buttons until a value appears. Press and hold ON-OFF to reset to 100.0 kg, then hang a calibration weight and press ON-OFF. The display shows 'PASS' if successful.
What to do if the display shows 'LO'?
The 'LO' message indicates low batteries. Replace the three AA batteries with new ones, observing polarity.
What to do if the display shows 'OL'?
The 'OL' message means the scale is overloaded. Immediately remove excess weight to avoid damage.
How to replace the batteries?
Open the battery compartment on the bottom of the scale, remove old batteries and insert three new AA 1.5V batteries, observing polarity (+ and -). Close the compartment.
Can I use the scale to weigh liquids?
Yes, provided you place the liquid in a suitable container and use the TARE function to subtract the container weight. Never pour liquid directly onto the scale.
Is the scale waterproof?
No, the scale is not waterproof. Do not immerse it in any liquid and protect it from moisture. Clean it only with a slightly damp cloth.

User questions about VTBAL601 Perel

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Scale in PDF format for free! Find your manual VTBAL601 - Perel and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. VTBAL601 by Perel.

USER MANUAL VTBAL601 Perel

natural_image Yellow digital scale measuring instrument with metal hooks and a spring scale (no visible text or symbols)

USER MANUAL 3

HANDLEIDING 7

MODE D'EMPLOI 11

MANUAL DEL USUARIO 15

text_image CRANE SCALE 0.0 N N K 1 2 3

USER MANUAL

1. Introduction

Perel VTBAL601 - Introduction - 1

To all residents of the European Union Important environmental information about this product

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules. If in doubt, contact your local waste disposal authorities.

Thank you for choosing Perel! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, do not install or use it and contact your dealer.

2. Safety Instructions

Perel VTBAL601 - Safety Instructions - 1

Read and understand this manual and all safety signs before using this appliance.

  • This device can be used by children aged from 8 years and above, and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the device in a safe way and understand the hazards involved. Children shall not play with the device. Cleaning and user maintenance shall not be made by children without supervision.
  • Protect this device from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
  • Do not remove the cover under any conditions. There are no user-serviceable parts inside. Never operate this device when its cover is removed.
  • Familiarise yourself with the functions of the device before actually using it.

3. General Guidelines

  • Refer to the Velleman ® Service and Quality Warranty on the last pages of this manual.
  • All modifications of the device are forbidden for safety reasons. Damage caused by user modifications to the device is not covered by the warranty.
  • Only use the device for its intended purpose. Using the device in an unauthorised way will void the warranty.
  • Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems.
  • Nor Velleman nv nor its dealers can be held responsible for any damage (extraordinary, incidental or indirect) – of any nature (financial, physical...) arising from the possession, use or failure of this product.
  • Keep this manual for future reference.

4. Batteries

Perel VTBAL601 - Batteries - 1

WARNING

Do not puncture batteries or throw them in fire as they may explode. Do not attempt to recharge non-rechargeable batteries (alkaline). Dispose of batteries in accordance with local regulations. Keep batteries away from children.

  • Open the battery compartment and insert the batteries according to the correct polarity.
  • Replace the batteries as soon as the display turns dark.
  • Remove the batteries after use.

5. Overview

Refer to the illustrations on page 2 of this manual.

1on-off/tare
2unit
3hold

6. Operation

6.1 General Operation

  1. Hold the scale in your hand or hang it on a solid truss.
  2. Switch on the scale. The scale is ready-to-use when the display shows 0.
  3. Hang the item to be weighed on the hook and wait for the display to stabilize
  4. To tare an item, tap the tare button. Place the item to be weighed on the scale.
  5. The weight is displayed.

6.2 Unit Conversion

Press the unit button until the desired weighing unit is displayed.

6.3 Hold Function

Press the hold button repeatedly to select the desired hold function:

Aauto holdThe weight is locked when stabilized.
Ppeak holdThe highest weight is locked. Good for measuring forces.
Nno holdThe weight does not lock.

6.4 Calibration

  1. With the scale off, press and hold the unit and on-off buttons simultaneously until a number appears in the display.
  2. Hold the on-off button pressed to reset the value to 100.0 kg.
  3. Hang the required calibration weight on the hook. Wait for the value to stabilize and press the on-off button. Calibration is complete when PASS appears on the display.

6.5 Error Indications

Perel VTBAL601 - Error Indications - 1

Battery power running low.

Perel VTBAL601 - Error Indications - 2

Overloaded. Remove excess weight.

Perel VTBAL601 - Error Indications - 3

Calibration needed.

7. Cleaning and Maintenance

  • Occasionally wipe with a damp cloth to keep it looking new. Do not use harsh chemicals, cleaning solvents or strong detergents.
  • Do not immerse the device in any liquid.

8. Technical Specifications

power supply.... 3 x 1.5 V AA batteries (incl.)

material...... ABS + steel

capacity.... 300 kg/661 lb.

graduation 300 g/10.6 oz.

units ...... kg/lb./N

dimensions 140 x 82 x 48 mm

display 56 x 26 mm

weight....785 g

Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulting from (incorrect) use of this device. For more info concerning this product and the latest version of this manual, please visit our website www.perel.eu. The information in this manual is subject to change without prior notice.

The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the prior written consent of the copyright holder.

HANDLEIDING

1. Inleiding

Perel VTBAL601 - Inleiding - 1

graduation 300 g/10.6 oz

unités.... kg/lb/N

dimensions 140 x 82 x 48 mm

Velleman® Service and Quality Warranty

Since its foundation in 1972, Velleman® acquired extensive experience in the electronics world and currently distributes its products in over 85 countries.

All our products fulfil strict quality requirements and legal stipulations in the EU. In order to ensure the quality, our products regularly go through an extra quality check, both by an internal quality department and by specialized external organisations. If, all precautionary measures notwithstanding, problems should occur, please make appeal to our warranty (see guarantee conditions).

General Warranty Conditions Concerning Consumer Products (for EU):

  • All consumer products are subject to a 24-month warranty on production flaws and defective material as from the original date of purchase.
  • Velleman® can decide to replace an article with an equivalent article, or to refund the retail value totally or partially when the complaint is valid and a free repair or replacement of the article is impossible, or if the expenses are out of proportion.
    You will be delivered a replacing article or a refund at the value of 100% of the purchase price in case of a flaw occurred in the first year after the date of purchase and delivery, or a replacing article at 50% of the purchase price or a refund at the value of 50% of the retail value in case of a flaw occurred in the second year after the date of purchase and delivery.

- Not covered by warranty:

  • all direct or indirect damage caused after delivery to the article (e.g. by oxidation, shocks, falls, dust, dirt, humidity...), and by the article, as well as its contents (e.g. data loss), compensation for loss of profits;
  • consumable goods, parts or accessories that are subject to an aging process during normal use, such as batteries (rechargeable, non-rechargeable, built-in or replaceable), lamps, rubber parts, drive belts... (unlimited list);
  • flaws resulting from fire, water damage, lightning, accident, natural disaster, etc....;
  • flaws caused deliberately, negligently or resulting from improper handling, negligent maintenance, abusive use or use contrary to the manufacturer's instructions;
  • damage caused by a commercial, professional or collective use of the article (the warranty validity will be reduced to six (6) months when the article is used professionally);
  • damage resulting from an inappropriate packing and shipping of the article;
  • all damage caused by modification, repair or alteration performed by a third party without written permission by Velleman®.
  • Articles to be repaired must be delivered to your Velleman® dealer, solidly packed (preferably in the original packaging), and be completed with the original receipt of purchase and a clear flaw description.
  • Hint: In order to save on cost and time, please reread the manual and check if the flaw is caused by obvious causes prior to presenting the article for repair. Note that returning a non-defective article can also involve handling costs.
  • Repairs occurring after warranty expiration are subject to shipping costs.
  • The above conditions are without prejudice to all commercial warranties.

The above enumeration is subject to modification according to the article (see article's manual).