USER MANUAL XK46 GREE
Wired Controller XK46 Owner's Manual Thank you for choosing Air Conditioners, please read this owner’s manual carefully before operation and retain it for future reference. If you have lost the Owner’s Manual, please contact the local agent or visit www.gree.com or send email to www.greeproducts.es for electronic version. GREE reserves the right to interpret this manual which will be subject to any change due to product improvement without further notice. GREE Electric Appliances, Inc. of Zhuhai reserves the final right to interpret this manual. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.User Notices ◆ The power supply for all indoor units must be unified. ◆ Prohibit installing the wired controller at wet or sunshine places. ◆ Do not knock, throw or frequently disassemble the wired controller. ◆ Do not operate the wired controller with wet hands. ◆ In one system network, you must set one indoor unit as the master indoor unit, Other indoor units are slave indoor units . ◆ The operation mode of the system is basing on that of master indoor unit. Master indoor unit can switch to any modes, while slave unit can’t switch to the mode that is conflicting with master indoor unit. ◆ When master indoor unit changes mode which cause operation mode of slave indoor unit conflicts with that of system, the operation mode of slave unit will switch to the operate mode of system automatically. ◆ When two wired controllers control one (or more) indoor unit(s), the address of wired controller should be different. ◆ Functions with “*” are optional for indoor units. If a function is not included in an indoor unit, wired controller can’t set the function, or setting of this function is invalid to the indoor unit. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.CONTENTS 1 DISPLAY .......................................................................................................... 1
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.4.5.3 Clock Timer ..................................................................................... 33
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
1 DISPLAY Fig. 1.1 Appearance of wired controller
1.1 LCD OF WIRED CONTROLLER
Fig. 1.2 LCD graphics of wired controller Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Table 1.1 LCD display instruction No. Symbols Instructions
It's valid under Save mode and displays during setting process. Temperature lower limit for Cooling: Limit the minimum temperature value under Cooling or Dry mode. Temperature upper limit for Heating: Limit the maximum temperature value under Heating, Space Heating or 3D Heating mode.
Auto mode (Under Auto mode, the indoor units will automatically select their operating mode as per the temperature change so as to make the ambient comfortable.)
It shows the setting temperature value(In case the wired controller is controlling a Fresh Air Indoor Unit, then the temperature zone will display FAP)
Heating mode Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Floor Heating mode (When Heating and Floor Heating simultaneously shows up, it indicates 3D Heating is activated.)
Outdoor unit operates under Save mode/upper limit of system capacitor less 100%/remote Save status
Current set fan speed (including auto, low speed, medium-low speed, medium speed, medium-high speed, high speed and turbo seven status)
Remind to clean the filter
Quiet status (including Quiet and Auto Quiet two status)
Allow auxiliary electric heating On icon
X-fan function Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
One wired controller controls multiple indoor units
It indicates the current wired controller is the slave wired controller (address of wired controller is 02)
Memory status (The indoor unit resumes the original setting state after power failure and then power recovery)
Current wired controller connects master indoor unit
Timer zone:Display system clock and timer status Note: When wired controller is connected with different indoor units, some functions will be different Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Fig. 2.1 Button graphics Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Table 2.1 Function instruction of buttons No. Buttons Instructions
FAN Switch among auto, low speed, low-medium speed, medium speed, medium-high speed, high speed and turbo status
MODE Switch Auto,Cooling, Dry, Fan, Heating, Floor Heating, 3D Heating and Space Heating modes for indoor unit. (Note: The Floor Heating, 3D Heating and Space Heating function icon will show up when the unit has those functions.)
FUNCTION Switch among Air, Quiet, Light, Health, Absence, Save, Clean, E-heater and X-fan functions.
SWING Set up and down swing status
ON/OFF Indoor unit On/Off 2+5
Simultaneously press “ ” and “ ” for 5s to enter or cancel the Child Lock function.
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Fig. 3.1 Parts of wired controller Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Name Panel of wired controller Self-tapping Screw ST3.9X25
Soleplate of wired controller Q'ty
Fig. 3.2 Length of communication line Wire material type Total length of communication line between indoor unit and wired controller L (m/feet) Wire size (mm
Material standard Remarks Light/Ordinary Polyvinyl chloride sheathed cord. (60227 IEC 52 /60227 IEC 53)
250m (L≤820-1/5feet) 2×0.75
(1)Total length of communication line can't exceed 250m (820-1/5feet). (2)The cord shall be Circular cord (the cores shall be twisted together). (3)If unit is installed in places with intense magnetic field or strong interference, it is necessary to use shielded wire. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Note: ① If the air conditioner is installed at the strong electromagnetic interference place, communication line of the wired controller must use shielding twisted pair. ② Materials of communication line for wired controller must be selected according to this instruction manual strictly
3.1.2 Installation requirements
(1) Prohibit installing the wired controller at wet places. (2) Prohibit installing the wired controller at direct sunshine places. (3) Prohibit installing the wired controller at the place near high temperature objects or water-splashing places. (4) Prohibit installing the wired controller at the place where faces forward to the window. Prevent abnormal work due to the interference from the other wired controller around.
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
There are four network wiring methods between wired controller and indoor unit: Fig. 3.3 One wired controller controls Fig. 3.4 Two wired controllers control one indoor unit one indoor unit Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Fig. 3.5 One wired controller controls multiple indoor units simultaneously Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Fig. 3.6 Two wired controllers control multiple indoor units simultaneously Wiring instructions: (1) When one wired controller controls multiple indoor units simultaneously, the wired controller can connect to any one indoor unit, but the connected indoor unit must be the same series indoor unit. The total quantity of indoor unit controlled by wired controller can't exceed 16 sets, and the connected indoor unit must be within the same indoor unit's network. Wire controller must set quantity of group control indoor units. Please refer to 3.2.3 Parameters Setting. (2) When two wired controllers control one indoor unit, the addresses of those two wired controllers should be different. Please refer to 3.2.3 parameter setting. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
(3) When two wired controllers control multiple indoor units, wired controller can connected to any one indoor unit, while the connected indoor unit should be the same series indoor unit. The addresses of those two wired controllers should be different. Please refer to 3.2.3 parameter setting. The total quantity of indoor unit controlled by wired controller can't be more than 16 sets and all connected indoor units must be within the same indoor unit network. Wire controller must set quantity of group control indoor units. Please refer to 3.2.3 Parameters Setting. (4) When one (or two) wired controller(s) control(s) multiple indoor units at the same time, the controlled indoor unit's setting should be the same. (5) Wiring of wired controller and indoor unit network must be according to one of the four wiring method as shown in fig 3.3-3.6. As for the connection method shown in fig 3.4 and 3.6, there should be only one master wired controller (address is 01) and one slave wired controller (address 02). The quantity of wired controller can't exceed two. Note: Series of indoor units include:①Common Multi VRF Units;②Fresh Air Units;③ Double-heat Sources Units;④Combined Units; Except for fresh air units, double-heat sources units and combined units, the rest of indoor units belong to common multi VRF units.
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Fig. 3.7 Installation diagram for wired controller Fig. 3.7 is the simple installation process of wired controller; please pay attention to the following items: (1) Before installation, please cut off the power for indoor unit. (2) Pull out the two-core twisted pair from the installation hole on wall, and then pull this wire through the " ” shape hole at the rear side of Soleplate of wired Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
controller. (3)Stick the bottom plate of wired controller on the wall and then use Self-tapping Screw ST3.9X25 MA to fix Soleplate and installation hole on wall together. (4) Connect two-core twisted pair to H1 and H2 wiring column and then fix the screws. (5) Set two-core into the groove at left side of wiring column, and then bundle panel and Soleplate of wired controller together. Note: If the wire size of the selected communication line is too large, you can peel some sheath layer of communication wire to satisfy installation requirements.
Fig. 3.8 Disassembly diagram of wired controller
3.2.1 Set Master Indoor Unit
Under Off status, long press MODE button for 5s to set the corresponding indoor unit of wired controller as master indoor unit. “MASTER” icon will be light Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
after finishing setting. Note: ① There is a master indoor unit in a system, other slave indoor units can be set as master unit, in which case, the original master unit will become a slave unit. ② In one system, only one set of master indoor unit is allowed. If system detects that there are several master units, it will designate the unit with the smallest project number as a master unit.
In “C00” status, Timer zone shows the current indoor unit project number. When one wired controller is controlling multiple indoor units, then only the smallest project number will be displayed. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
unit network, “MASTER” icon will be bright under “C01” interface. After entering the interface of viewing project number, “MASTER” icon will be bright only when the project number of master indoor unit is selected.
2) System will not exit “C01” viewing
automatically. User has to exit this interface manually. C03 View the indoor unit quantity of the system network 1-80 Timer zone: display indoor unit quantity of the system Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Operation method: Enter viewing: press MODE button in “C07” status to enter the interface of viewing indoor ambient temperature. Press “ ” or “ ” button to select indoor unit. Display method: Temperature zone: displays current indoor unit project number; Timer zone: displays indoor ambient temperature. C08 View Filter Clean Reminder time 4-416: days Timer zone: displays Filter Clean Reminder time C09 View address of wired controller 01, 02 Timer zone: displays the address of wired controller Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
code Parameter name Parameter range Viewing method C11 View the indoor unit quantity in the case that one wired controller controls several indoor units at the same time 1-16 Timer zone: displays the indoor unit quantity controlled by the wired controller C12 View outdoor ambient temperature
Timer zone: displays outdoor ambient temperature C17 View indoor relative humidity 20~90 relative humidity20% ~90% Operation method: Enter into review process and press “MODE” button to enter into the review interface of indoor relative humidity under C17 status. Press “ ” or “ ” button to switch the number of indoor unit. Display method: Temp area: display current indoor unit’s project number Timer zone: display indoor relative humidity Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
1) After turning on the one-button viewing
function, each wired controller of the entire system will display the project number of its controlling indoor unit on its timer zone. (The timer zone will display different project numbers in turn with an interval of 3 seconds if one wired controller is controlling multiple indoor units.)
2) Slave wired controller cannot view “C18”.
1) If user exits the “C18” interface manually, the
one-button viewing function will be immediately turned off.
2) If system exits the “C18” interface due to no
action in 20 seconds, user has to press the “ON/OFF” button under on/off status to cancel this function.
3) After the one-button viewing function is
turned on, pressing the “ON/OFF” button of any wired controller of the same system network under on/off status will cancel this function. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Note P10 Set master indoor unit 00: do not change current master/slave state of indoor unit 01: set current indoor unit as master indoor unit
When set the corresponding indoor unit of wired controller as master indoor unit,“MASTER” icon will be bright after finishing setting. P11 Set infrared receiver of wired controller 00: forbidden 01: activated
It can be set only through master wired controller. When infrared receiver of wired controller is forbidden, the wired controller can’t receive the signal from remote controller and it is operated through buttons. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Note P13 Set address of wired controller 01: master wired controller 02: slave wired controller
When two wired controllers control one indoor unit (or several indoor units), the addresses of the two wired controllers should be different. Assistant wired controller (02) is without unit parameter setting function except setting its address. P14 Set quantity of group control indoor units 00: forbid this function 01-16: indoor unit quantity
Set the corresponding value according to the connected indoor unit quantity. P16 Set unit of temperature 00:Celsius 01:Fahrenheit
There are two kinds of static pressure level: 5 levels: 03, 04, 05, 06, 07 9 levels: 01, 02, 03, 04, 05, 06, 07, 08, 09 Wired controller can be adapted to the different types of indoor units that it possesses 1-9 level selection for setting static pressure. When the indoor unit with 5 static pressure levels received the level setting sent by wired controller is less than 3, it will be settled as the 3rd level; if it is over 7, it will be settled as the 7th level. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Note P31 High ceiling installation* 00: installation height of standard ceiling 01: installation height of high ceiling
Only applicable to cassette units P33 Set Timer 00: general timer 01: clock timer
Available only when timer is set to clock timer. P37 Cooling setting temperature under auto mode 17°C~30°C(63°F ~86°F) 25°C (77°
P43 Set priority operation 00: normal operation 01: priority operation
When power supply is insufficient, the indoor units which are set to priority operation can operate, while other indoor units are forced to be turned off. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Only applicable to units with air-return plate P50 Air outlet temperature setting for Fresh Air Indoor Unit in cooling* 16°C~30°C(61°F
Only applicable to Fresh Air Indoor Unit P51 Air outlet temperature setting for Fresh Air Indoor Unit in heating* 16°C~30°C(61°F
Only applicable to Fresh Air Indoor Unit P54 Union setting of Fresh Air Indoor Unit* 00: without union control 01: with union control
After union function is set, Fresh Air Indoor Unit will be turned on/off following the on/off status of common indoor unit. Besides, Fresh Air Indoor Unit can also be turned on/off manually. Note: only applicable to Fresh Air Indoor Unit. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Note: ① Under parameter setting status, FAN, TIMER, SLEEP and SWING button are invalid. Press ON/OFF button to go back to home page, but not turning on/off the unit. ② Under parameter setting status, the signal from remote controller is invalid. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Press ON/OFF button to turn on the unit. Press ON/OFF button again to turn off the unit. The interfaces of On/Off status are shown in fig. 4.1 and 4.2. Fig. 4.1 Interface of On status Fig. 4.2 Interface of Off status
Under On status, pressing MODE button can set mode circularly as: Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Note: ① the available modes are different for different models, the wired controller will automatically select mode setting range according to the model of indoor unit. ② The Auto mode can be only set at the master indoor unit. ③ Under Auto mode, if the indoor unit is running under Cooling, the icons“ ” and “ ” will light up; if the indoor unit is running under Heating, the icons“ ” and “ ” will light up.
3.3 TEMPERATURE SETTING
Pressing “ ” or “ ” button in On status increases or decreases set temperature by 1°C; holding “ ” or “ ” button increases or decreases set temperature by 1°C every 0.3s. In Cooling, Fan, Heating, Floor Heating, 3D Heating or Space Heating mode, temperature setting range is 16°C~30°C. In Dry mode, the temperature setting range is 12°C, 16°C~30°C. In Dry mode, when temperature is 16°C, continuously press “ ” button twice to decrease temperature to 12°C (when save function is activated, the temperature in Dry mode can’t be adjusted to 12°C and the setting range is “lowest temperature in Save mode” ~ 30°C). Note: ① Under Auto mode or Out function is activated, the setting temperature can not be adjusted by pressing “ ” or “ ”. ② When the wired controller is connected with a Fresh Air Indoor Unit, fresh air indoor unit code “FAP” will be displayed as shown below. Setting temperature won’t be displayed and can’t be adjusted via “ ” or “ ” button. The air outlet temperature in cooling or heating can only be set in the parameter setting status. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Under On status, pressing FAN button can set fan speed circularly as: Note: ① In Dry mode, fan speed is low and can’t be adjusted. ② When the wired controller is connected with a Fresh Air Indoor Unit, fan speed of indoor unit will be high fan speed only. Fan speed of indoor unit can’t be adjusted via “FAN” button. ③ If indoor unit’s fan speed is set auto, indoor unit will change fan speed automatically according to room temperature in order to make the room temperature more stable and comfortable.
The wired controller is equipped with two kinds of timer: general timer and clock timer. General timer is factory defaulted setting. Please refer to Section 3.2.3 for the timer setting way.
Unit On/Off after a desired hour can be set through general timer. Set Timer: when timer is not set, press TIMER button to enter timer setting and “HOUR” icon is blinking. Press “ ” or “ ” button to adjust timer time. Press TIMER button to save the setting and then exit setting. (2) Turbo function setting Start turbo function: In unit on status, press “FUNCTION” button to switch to Turbo function with Turbo function icon “ ”blinking, and then press “ENTER/CANCLE” button to start Turbo function. When Turbo function is activated, Turbo function icon “ ”will be bright. Cancel Turbo function: When Turbo function is activated, press “FUNCTION” button to switch to Turbo function with Turbo function icon“ ” blinking, and then press “ENTER/CANCEL” button to cancel Turbo function ; Press “FAN” button to cancel turbo function and start auto speed. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Clock setting: long press TIMER button for 5s to enter clock setting and
icon is blinking. Pressing “ ” or “ ” button increases or decreases clock time by 1min; holding “ ” or “ ” button for 5s increases or decreases clock time by 10min; Press ENTER/CANCEL button or TIMER button to save the setting and then exit setting.
Unit On/Off at a certain time can be set through clock timer. Set Timer: (1) Press TIMER button to enter timer on setting and the “ON” icon is blinking; (2) Press “ ” or “ ” button to adjust unit On time. Press ENTER/CANCEL button to finish setting; (3) Before pressing ENTER/CANCEL button, pressing TIMER button can save unit On time and then switch to unit Off time setting with “OFF” icon blinking; (4) Press “ ” or “ ” button to adjust unit Off time. Press ENTER/CANCEL button to finish setting; Cancel Timer: Press TIMER button to enter timer setting; press TIMER button again to switch to the setting of unit ON time or unit Off time; press ENTER/CANCEL button to cancel timer. Pressing “ ” or “ ” button increases or decreases timer time by 1min; holding “ ” or “ ” button for 5s increases or decreases timer time by 10min. Clock Timer setting is as shown in fig. 4.4: Unit is on and timer is not set Press TIMER button to set unit On time Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
down swing icon will blink during switching.
When simple swing mode is set in unit on status, press “SWING” button to start or stop up & down swing.
When fixed-angle swing mode is set in unit on status, press “SWING” button to adjust swing angle circularly as below: (2) Left & right swing function*: Start left & right swing: In unit on status, press “FUNCTION” button to switch to left & right swing function with left & right swing icon blinking, and then press “ENTER/CANCLE” button to start left & right swing. When left & right swing is activated, left & right swing icon will be bright. Cancel left & right swing: When left & right swing is activated, press “FUNCTION” button to switch to left & right swing with left & right swing icon blinking, and then press “ENTER/CANCLE” button to cancel left & right swing.
Quiet Function: decrease the noise of indoor unit and achieve the quiet effect. Quiet function has two modes: Quiet mode and Auto Quiet mode. It is available only in Auto, Cooling, Dry, Fan, Heating, 3D heating, Space heating mode. Turn on Quiet Function: press FUNCTION button to turn to Quiet function and then Quiet icon “ ” or auto quiet icon “ ” is blinking. At this moment, press “ ” or “ ” button to switch between quiet and auto quiet, and then press ENTER/CANCEL button
activate. Turn off Quiet Function: press FUNCTION button to turn to Quiet function and then press ENTER/CANCEL button to cancel Quiet function. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
The setting of Quiet function is as shown in fig. 4.5: Press FUNCTION button to turn Press “ ” or “ ” button to switch to Quiet function between Quiet and Auto QuietAT Press ENTER/CANCEL button to activate Quiet function Fig. 4.5 Setting of Quiet function Note: ① When Quiet function is enabled, indoor unit will operate at quiet fan speed. Fan speed is lowered so as to reduce the noise of indoor fan motor. ② When Auto Quiet function is enabled, indoor unit will change fan speed automatically according to room temperature. After room temperature reaches a set point, unit will operate at quiet fan speed.
Sleep Function: in this mode, the unit will operate according to the preset sleep Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Turn off the Light: When light of indoor unit is on, press FUNCTION button to select Light. Then press ENTER/CANCEL to turn off the light. Note: When there is no button operation on the wired controller or no remote control signal is received for 20s continuously: ① If Light function is activated, the back light of LCD will turn to half bright. ② If Light function is off, the back light of LCD will be off. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Save Function: Air conditioner can be operated in small temperature range by setting the minimum temperature under Cooling and Dry modes and setting maximum temperature under Heating, 3D Heating and Space Heating modes. Thus, energy saving can be realized. There’re two kinds of setting method for Save function. As for the Save Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
function for different kinds of wired controller, the setting method is one of those two methods. Setting method one: Start up Save function for Cooling: When the unit is off, simultaneously press “TIMER” and “ ” buttons for 5s, the buzzer will give out a sound and then unit will enter into Save setting mode. “ ” icon is blinking. “MIN” icon and Mode icon are on. Press “MODE” button to switch to Cooling or Dry mode. Press “ ” or “ ” button to adjust the temperature limit for Save function; press “ENTER/CANCEL” button to start up Save function. Fig.4.13 or 4.14 Shows how to set Save function for Cooling: Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Fig.4.13 Save Setting for Cooling in Celsius Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
setting, press “ENTER/CANCEL” button to cancel Save function of all modes. Setting method two: Save Setting for Cooling: When unit is on and under Cooling or Dry mode, press FUNCTION button to select Save function. “ ” icon will blink and MIN icon lit up. Press “ ” or “ ” button to adjust to the minimum temperature. Press ENTER/CANCEL button to activate this function. Fig.4.15 or 4.16 Shows how to set Save function for Cooling: Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Fig.4.15 Save Setting for Cooling in Celsius Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Fig.4.16 Save Setting for Cooling in Fahrenheit Save Setting for Heating: When unit is on and under Heating, 3D Heating and Space Heating modes, press FUNCTION button to select Save function. “ ” icon will blink and MAX icon lit up. Press “ ” or “ ” button to adjust the MAXIMUM temperature. Press ENTER/CANCEL button to turn on this function. Turn off Save Function: Press FUNCTION button and select Save function. “ ” icon blinks. Then press ENTER/CANCEL button to cancel this setting. Note: When the Save function is turned on and then set temperature exceeds the limit value for Save function, “ ” icon blinks three times and then buzzer will give out two sounds successively. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Filter Clean Reminder Function: Unit will remember its own operating time. When the setting time is up, this function will remind you to clean the filer. A dirty filter will result in bad heating and cooling performance, abnormal protection, bacteria gathering, etc. Turn on Filter Clean Reminder Function: When unit is on, press FUNCTION button and select Filter Clean Reminder. “ ” icon will blink. Press “ ” or “ ” button to adjust the cleaning level, of which the range is 00, 10-39. Press ENTER/CANCEL to turn on this function Turn off Filter Clean Reminder Function: When unit is on and this function has been turned on, press FUNCTION button and select Clean. Then “ ” icon will blink. Set the cleaning level as 00 and press ENTER/CANCEL function to cancel this setting. When Filter Clean Reminder time is up, “ ” icon will light up to remind you to clean the filer. Press FUNCTION button to turn to Filter Clean Reminder Function, then press SWING/ENTER to cancel reminding, and it will retime according to the original cleaning level. The clean reminding can be cancel only when you didn’t reset the Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
Slight Pollution The former digit shows 1 while the latter one shows 0, which indicates the accumulating operating time is 5500 hours. Each time the latter digit increases 1, the operating time increases 500 hours. When it reaches 9, it means the operating time is 10000 hours. Medium Pollution The former digit shows 2 while the latter one shows 0, which indicates the accumulating operating time is 1400 hours. Each time the latter digit increases 1, the operating time increases 400 hours. When it reaches 9, it means the operating time is 5000 hours. Heavy Pollution The former digit shows 3 while the latter one shows 0, which indicates the accumulating operating time is 100 hours. Each time the latter digit increases 1, the operating time increases 100 hours. When it reaches 9, it means the operating time is 1000 hours.
X-fan Function: If unit is turned off under Cooling or Dry mode, the evaporator of indoor unit will be dried off automatically to prevent bacteria and mould from gathering. Turn on X-fan: When unit is on or under Cooling or Dry mode, press FUNCTION button to select X-fan. “ ” icon will blink. Then press ENTER/CANCEL button to turn on this function. Turn off X-fan: When X-fan function is on, press FUNCTION button to select X-fan. “ ” icon will blink. Then press ENTER/CANCEL button to turn off this function.
Out Function: This is used to maintain indoor temperature so that unit can realize fast heating after it is turned on. This function can only be used under Heating mode. Turn on Out Function: Under Heating mode, press FUNCTION button to select Out. “ ” icon will blink. Then press ENTER/CANCEL button to turn on this function. Turn off Out Function: When this function is on, press FUNCTION button to select Out. “ ” icon will blink. Then press ENTER/CANCEL button to turn off this function.
3.15 REMOTE SHIELD FUNCTION
Remote Shield Function: Remote monitor or central controller can disable the relevant functions of wired controller so as to realize the function of remote control. Remote Shield Function includes all shield and partial shield. When All Shield function is on, all controls of the wired controller are disabled. When Partial Shield function is on, those controls that are shielded will be disabled. Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.Wired Controller XK46
When the remote monitor or central controller activates Remote Shield on the wired controller, “ ” icon will show. If user wants to control through the wired controller, “ ” icon will blink to remind that these controls are disabled.
3.16 CHILD LOCK FUNCTION
When unit is turned on normally or turned off, pressing “ ” and “ ” button together for 5 seconds will turn on Child Lock function. “ ” will show on the display. Pressing “ ” and “ ” together again for 5 seconds to turn off this function. All the other buttons will be disabled when Child Lock function is on.
3.17 GATE-CONTROL FUNCTION
When there is Gate-control System, user can insert a card to turn on the unit or pull off a card to turn off the unit. When the card is re-inserted, the unit will recover the operation as state in memory. When the card is pulled off (or improperly inserted), “ ” icon will show, neither remote control nor operation of wired controller will be effective and icon “ ” will be flickering. Note: This model cannot be connected with gate control system on its own because it cannot detect gate control signal directly. To realize gate control display and gate control function, it has to be used with wired controller that includes gate control signal detecting function (used as master and salve wired controller). Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.20 Controlador por cable XK46