IFM E30131 - Industrial adapter

E30131 - Industrial adapter IFM - Free user manual and instructions

Find the device manual for free E30131 IFM in PDF.

📄 9 pages English EN Download 💬 AI Question
Notice IFM E30131 - page 1
View the manual : Français FR Deutsch DE English EN
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about E30131 IFM

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Industrial adapter in PDF format for free! Find your manual E30131 - IFM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. E30131 by IFM.

USER MANUAL E30131 IFM

Installation instructions

Screw-in adapter for process sensors

Aseptoflex Vario

Contents

1 Preliminary note 3

1.1 Symbols used 3
1.2 Warnings.... 3

2 Safety instructions.... 4
3 Transport, handling and storage 5
4 Intended use.... 6
5 Installation.... 7
6 Set-up 8
7 Disposal 9

1 Preliminary note

You will find instructions, technical data, approvals and further information using the QR code on the unit / packaging or at documentation.ifm.com.

1.1 Symbols used

√ Requirement
Instructions
Reaction, result

[...] Designation of keys, buttons or indications

→ Cross-reference

IFM E30131 - Symbols used - 1

Important note

Non-compliance may result in malfunction or interference.

IFM E30131 - Symbols used - 2

Information

Supplementary note

1.2 Warnings

Warnings indicate the possibility of personal injury and damage to property. This enables safe product handling. Warnings are graded as follows:

IFM E30131 - Warnings - 1

WARNING

Warning of serious personal injury

▷ If the warning is not observed, fatal and serious injuries are possible.

IFM E30131 - Warnings - 2

CAUTION

Warning of minor to moderate personal injury

▷ If the warning is not observed, minor to moderate injuries are possible.

ATTENTION

Warning of damage to property

▷ If the warning is not observed, damage to property is possible.

2 Safety instructions

- The unit described is a subcomponent for integration into a system.

  • The system architect is responsible for the safety of the system.
  • The system architect undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system. This documentation must contain all necessary information and safety instructions for the operator, the user and, if applicable, for any service personnel authorised by the architect of the system.

  • Read this document before setting up the product and keep it during the entire service life.

  • The product must be suitable for the corresponding applications and environmental conditions without any restrictions.
  • Only use the product for its intended purpose (→ Intended use).
  • Only use the product for permissible media (→ Technical data).
  • If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property may occur.
  • The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator.
  • Installation, set-up, operation and maintenance of the product must be carried out by qualified personnel authorised by the machine operator.
  • Protect the product against damage.

3 Transport, handling and storage

▶ Store the product in its original packaging.
▶ Observe the permissible ambient conditions for the product during storage ( → Technical data).
▶ In case of return shipment, ensure that the product or components are cleaned especially from dangerous and toxic substances.

4 Intended use

The screw-in adapter allows the installation of sensors in tanks or piping systems.

5 Installation

Before installing and removing the device: make sure that no pressure is applied to the system.

IFM E30131 - Installation - 1

IFM E30131 - Installation - 2

IFM E30131 - Installation - 3

Figure 1

▶ Slightly grease the thread and sealing area of the sensor and the adapter with a lubricating paste (A).
The lubricating paste must be suitable and approved for the given application and compatible with the elastomers used.
▶ Place the sealing ring (B) in the groove (C) of the sensor.
The adapter is supplied with an EPDM O-ring. More sealing rings are available as accessories: FKM O-ring, order no. E30123.

Figure 2:

▶ Screw the sensor into the adapter until it is hand-tight.
▶ Neither damage the seals nor the sealing areas.

Figure 3:

▶ Clamp the adapter with the screwed-in sensor into a clamping device (D). Do not deform or damage the adapter.
▶ Tighten the sensor using a spanner until you can feel the end stop (this corresponds to a maximum tightening torque of 35 Nm).

Further tightening may impair the sealing effect.

▷ If the sealing surfaces are damaged, replace the device or the adapter.

▶ Remove the adapter with the sensor from the clamping device.
▶ Install the adapter with the sensor in the plant.

6 Set-up

▶ Before setting up the system: Check all components for ingress resistance.
▶ Setting up the sensor: → Operating instructions of the sensor.

7 Disposal

▶ After use dispose of the product or components in an environmentally friendly way in accordance with the applicable national regulations.