IFM OID204 - Rangefinder

OID204 - Rangefinder IFM - Free user manual and instructions

Find the device manual for free OID204 IFM in PDF.

📄 7 pages English EN Download 💬 AI Question
Notice IFM OID204 - page 1
View the manual : Français FR Deutsch DE English EN
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about OID204 IFM

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Rangefinder in PDF format for free! Find your manual OID204 - IFM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. OID204 by IFM.

USER MANUAL OID204 IFM

CE

Operating instructions Optical distance sensor

OID20x

IFM OID204 - 1

Contents

1 Preliminary note....3
1.1 Symbols used .... 3
2 Safety instructions ....3
3 Functions and features .... 4
3.1 Applications ....4
4 Installation....5
4.1 Installation conditions ....5
5 Electrical connection....5
6 Operating and display elements ....6
7 Settings / operation....6
7.1 Switch off the laser 6
8 IO-Link 7
8.1 General information....7
8.2 Device-specific information....7
8.3 Parameter setting tools....7
9 Maintenance, repair, disposal....7

1 Preliminary note

1.1 Symbols used

▶ Instructions

▷ Reaction, result

[...] Designation of keys, buttons or indications

→ Cross-reference

Important note

Non-compliance may result in malfunction or interference.

Information

Supplementary note

2 Safety instructions

  • Read this document prior to set-up of the unit. Ensure that the product is suitable for your application without any restrictions.
  • Improper or non-intended use may lead to malfunctions of the unit or to unwanted effects in your application. That is why installation, electrical connection, set-up, operation and maintenance of the unit must be carried out by qualified personnel authorised by the machine operator.
  • In case of malfunction of the unit please contact the manufacturer. If the unit is tampered with and/or modified, any liability and warranty is excluded.
  • The unit complies with the standard EN 61000-6-4. The unit may cause radio interference in domestic areas. If interference occurs, the user must take appropriate remedial actions.

Visible laser light; laser protection class 2.

Use of controls or adjustments other than those specified herein may result in hazardous radiation exposure. Damage to the retina is possible.

▶ Do not stare into the laser beam!
▶ Apply the enclosed labels (laser warning) in the immediate vicinity of the unit.
▶ Adhere to the caution and warning notes on the product label.
▶ Use the enclosed label for the power supply cable.
▶ EN/IEC 60825-1 : 2007 and EN/IEC 60825-1 : 2014
Complies with 21 CFR 1040.10 except for conformance with IEC 60825-1 Ed. 3., as described in Laser Notice No. 56, dated May 8, 2019.

Label for supply cable

ATTACH TO CABLE
IFM OID204 - Safety instructions - 1
ifm electronic gmbh

WARNING:

CLASS 2 LASER PRODUCT

DO NOT STARE INTO BEAM

- AVOID EXPOSURE

- UNPLUG CONNECTOR TO

EXTINGUISH LASER BEAM

D-45128 Essen

Product label

IFM OID204 - Safety instructions - 2

AVOID EXPOSURE

LASERRADIATIONEMITTED

FROM THIS APERTURE

IFM OID204 - Safety instructions - 3

CAUTION

LASERRADIATION

DO NOT STARE INTO BEAM

max. POWER ≤ 4,0 mW, PULSE 1,3 ns, λ = 650 nm

IFM OID204 - Safety instructions - 4

CLASS 2 LASER PRODUCT

21 CFR PART 1040

IEC 60825-1:2014

IFM OID204 - Safety instructions - 5

3 Functions and features

The unit is used as an optical distance sensor.

3.1 Applications

  • The optical distance sensor measures distances between 0.03 and 2 m.
  • It has a background suppression of up to 20 m.
    • The switching outputs are complementary.

IFM OID204 - Applications - 1

The distance between the sensor and the background must be limited to max. 20 m by the customer. Otherwise measured values can be ambiguous → 4.1 Installation conditions.

4 Installation

4.1 Installation conditions

▶ Install the unit so that the object to be detected is within a measuring range of 0.03...2 m.

Any object between the set switch point and a distance of 20 m from the sensor is suppressed.

IFM OID204 - Installation conditions - 1

Reflecting surfaces in the direct beam path of the sensor – also in the range > 20 m – are to be avoided by the customer. Otherwise the measured values can be ambiguous.

5 Electrical connection

IFM OID204 - Electrical connection - 1

The unit must be connected by a qualified electrician.

▶ The national and international regulations for the installation of electrical equipment must be adhered to.
▶ Ensure voltage supply to EN 50178, SELV, PELV.

▶ Disconnect power.
▶ Connect the unit as follows:

DC PNP

IFM OID204 - Electrical connection - 2

IFM OID204 - Electrical connection - 3

5: IN = Laser on / off
4: OUT1 = normally open / IO-Link
2: OUT2 = normally closed

Core colours of ifm sockets:

1 = BN (brown), 2 = WH (white), 3 = BU (blue), 4 = BK (black), 5 = GR (grey)

6 Operating and display elements

IFM OID204 - Operating and display elements - 1

1: LED yellow: Set value reached, output OUT1 = High (if OUT1 is configured as NO)

7 Settings / operation

The unit is set via the IO-Link interface. ( → 8 IO-Link)

On delivery the unit can also be used without IO-Link. Preset switch point: 2 m

▶ After installation, electrical connection and programming, check whether the unit operates correctly.

IFM OID204 - Settings / operation - 1

Lifetime of a laser diode: 50,000 hours

7.1 Switch off the laser

For safety and maintenance purposes the laser of the unit can be temporarily switched off via the input on pin 5.

Input signal at pin 5Laser
Low / not connectedOn
HighOff

8.1 General information

This unit has an IO-Link communication interface which requires an IO-Link-capable module (IO-Link master) for operation.

The IO-Link interface enables direct access to the sensor values and parameters and provides the possibility to set the parameters of the unit during operation.

In addition communication is possible via a point-to-point connection with a USB adapter cable.

You will find more detailed information about IO-Link at www.ifm.com.

8.2 Device-specific information

You will find the IODDs necessary for the configuration of the IO-Link device and detailed information about sensor values, diagnostic information and parameters in the overview table at www.ifm.com.

8.3 Parameter setting tools

You will find all necessary information about the required IO-Link hardware and software at www.ifm.com.

9 Maintenance, repair, disposal

Faulty sensors must only be repaired by the manufacturer.

▶ Keep the front lens of the sensor clean.
▶ After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations.
▶ Do not open the module housing. There are no user-serviceable components inside.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : IFM

Model : OID204

Category : Rangefinder