ADE Suki BE 1909 - Scale

Suki BE 1909 - Scale ADE - Free user manual and instructions

Find the device manual for free Suki BE 1909 ADE in PDF.

📄 60 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice ADE Suki BE 1909 - page 14
Pick your language and provide your email: we'll send you a specifically translated version.
Product type Digital scale
Brand ADE
Model Suki BE 1909
Dimensions (L x W x H) Approx. 300 x 300 x 20.5 mm
Maximum capacity 180 kg
Accuracy ± 1 % + 100 g
Display increments 50 g (up to 100 kg) / 100 g (above)
Power supply 3 LR03 (AAA) 1.5 V batteries
Units of measurement kg (lb optional)
Surface material Glass or plastic (not specified)
Functions Simple weighing, auto-off, manual calibration
Maintenance Wipe with a slightly damp soft cloth; disinfect occasionally
Safety Do not step on one-sidedly; do not use with wet feet; do not overload
Repairability Repairs only by a specialist workshop
Spare parts Batteries and anti-slip feet (not supplied separately)
Package contents Scale, 3 LR03 batteries, instruction manual
Warranty 2 years (material/manufacturing defects)
Distribution Waagen-Schmitt GmbH, Hamburg

Frequently Asked Questions - Suki BE 1909 ADE

How to change the batteries of the ADE Suki BE 1909 scale?
Open the battery compartment located under the scale by sliding the cover. Insert 3 LR03 (AAA) 1.5 V batteries respecting polarity (+/-). Close the cover until it clicks. Replace all batteries at the same time when the display shows "Lo".
How to change the unit of measurement (kg/lb)?
Turn on the scale by pressing lightly in the center. Press the UNIT button located under the scale to switch from kg to lb (pound). The displayed unit changes on the screen.
What does the display "Lo" on the scale mean?
"Lo" indicates that the batteries are low or empty. Replace all 3 batteries with new LR03 (AAA) batteries.
What to do if the display shows "Err"?
"Err" means that the maximum capacity of 180 kg has been exceeded. Step off immediately to avoid damaging the scale.
How to calibrate the scale after changing batteries?
Place the scale on a hard, flat surface. Step on briefly then step off. Wait until the display shows "0.0". This calibration is necessary after each battery change.
Can I use the scale on a carpet?
No. Always place the scale on a hard, flat, dry surface. Use on carpet or rug may cause inaccurate measurements.
What is the maximum weight the scale can support?
The maximum allowed weight is 180 kg. Never exceed this limit to avoid damage.
How to clean my ADE Suki scale?
Use a slightly damp soft cloth. Do not use abrasive or harsh detergents. Never immerse the scale in water. You can disinfect the surface with an appropriate disinfectant.
Why does my scale show incorrect results?
Check that the scale is on a flat, hard surface, away from electromagnetic devices (phone, radio). If the problem persists, remove the batteries, wait, then reinsert them respecting polarity.
Can children use this scale?
Yes, under adult supervision and from 8 years. Children must not play with the device. Batteries are dangerous if swallowed: keep them out of reach of young children.

User questions about Suki BE 1909 ADE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Scale in PDF format for free! Find your manual Suki BE 1909 - ADE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Suki BE 1909 by ADE.

USER MANUAL Suki BE 1909 ADE

22089 Hamburg, Germany

You have chosen to purchase a high-quality ADE brand product, which combines intelligent functions with an exceptional design. This bathroom scale makes it possible for you to determine and monitor your body weight. The wealth of experience of the ADE brand ensures a high technical standard and proven quality.

We hope you enjoy weighing yourself and wish you success in reaching your goal weight!

Your ADE Team

General information

About this operating manual

ADE Suki BE 1909 - About this operating manual - 1

This operating manual describes how to operate and maintain your product safely. Keep this operating manual in a safe place for future reference. If you pass this product on to someone else, pass on this operating manual as well.

Failure to observe this operating manual may result in injuries or damage to your product.

Explanation of symbols

ADE Suki BE 1909 - Explanation of symbols - 1

This symbol combined with the word DANGER warns of serious injuries.

ADE Suki BE 1909 - Explanation of symbols - 2

This symbol combined with the word WARNING warns of moderate and mild injuries.

ADE Suki BE 1909 - Explanation of symbols - 3

This symbol combined with the word NOTE warns of material damage.

ADE Suki BE 1909 - Explanation of symbols - 4

This symbol indicates additional information and general notes.

Table of contents

General information 12
Intended use 14
Safety 14
Overview 16
Scope of delivery 16
Start-up 17
Weighing 18
Resetting the scale. 18
Cleaning 18
Fault/Remedy 19
Technical data 19
Declaration of conformity 20
Warranty 20
Disposal 20

The bathroom scale is designed for the weighing of people in the home. It is not suitable for use in clinics, medical practices, etc.

The maximum carrying capacity of 180kg must not be exceeded.

Safety

  • This product may be used by children aged 8 and above, as well as by persons with reduced physical, sensory, or mental capacities or lacking experience and knowledge if they are supervised or have been instructed in the safe use of the product and understand the risks that may arise.
    Children must not play with the product.
  • Cleaning and user maintenance must not be carried out by children, unless they are 8 years of age or older and are being supervised.
  • Batteries, when swallowed, can be life-threatening. You should therefore keep the batteries and scale out of reach of small children. If a battery has been swallowed, medical assistance must be sought immediately.

DANGER for children

  • Keep packaging material away from children. There is a risk of choking if swallowed. Also pay attention that children do not pull the packaging material over their heads.

RISK of fire/burning and/or explosion

  • There is a risk of explosion if the batteries are replaced improperly. Replace the batteries only with the same or equivalent battery type. Pay attention to the "Technical data".
  • Batteries must not be recharged, reactivated by other means, dismantled, thrown into fire, or short-circuited. Otherwise, there is an increased risk of explosion and leakage; furthermore, gases may escape!
  • Avoid contact of the battery fluid with skin, eyes, and mucosa. In case of contact, immediately rinse the affected areas with plenty of clean water and consult a doctor.

WARNING of risk of injury

  • Do not step onto the outer edge of any one side of the scale. Risk of tipping!
  • Do not step onto the scale with wet feet or when its surface is damp. Risk of slipping!
  • If the scale falls down and shatters, there is a risk of injury from glass splinters.

BEWARE of material damage

  • Place the scale on a stable, even surface.
  • Do not overload the scale. Pay attention to the "Technical data". Place yourself on the scale exclusively for weighing purposes.
  • Protect the scale from strong shocks and vibrations.

  • Remove the batteries from the scale when they are depleted or when you are no longer using the scale. You will thus avoid damage that may result from leakage of battery acid.

  • When inserting and changing batteries, pay attention to the correct polarity (+/-) .
  • Do not subject the batteries to any extreme conditions, by – for example – storing them on radiators or under direct sunlight. Increased risk of leakage!
  • Clean the battery and device contacts, as needed, before inserting the battery.
  • Do not make any modifications to the product. Only allow repairs to be carried out by a specialist workshop. Repairs carried out improperly can considerably endanger the user.
  • Do not place the scale in the vicinity of devices that may emit electromagnetic radiation, such as mobile phones, wireless devices, or the like. Doing so may lead to incorrect display indications or malfunctions.
  • There are feet on the underside of the scale. Since floor surfaces are made from various materials and are treated with diverse care products, it cannot be completely excluded that some of these substances contain ingredients that may adversely affect and soften the feet of the device. If necessary, place a non-slip pad under the scale.

ADE Suki BE 1909 - BEWARE of material damage - 1

1 UNIT button (underside): Changing the unit of measurement
2 Display
3 Weighing surface
4 Battery compartment (underside)

Scope of delivery

  • Bathroom scale
    Battery type LR03 (AAA), 1.5 x= (3x)
  • Operating manual

Inserting/changing batteries

For use you need 3 batteries of type LR03 (AAA), 1.5V (included). The battery compartment is located on the underside of the device.

  1. Slide the battery compartment cover in the direction of the arrow and remove it.
  2. Insert the batteries as indicated at the bottom of the battery compartment. Pay attention to the correct polarity (+/-) .
  3. Replace the battery compartment cover and push it against the direction of the arrow as far as it will go.

ADE Suki BE 1909 - Inserting/changing batteries - 1

Suggestions for changing the battery:

  • A battery change is necessary when "Lo" or nothing at all is shown on the display.
  • Only use the type of battery that is specified in the "Technical data".

Always change all batteries at the same time.
- Dispose of old batteries in an environmentally appropriate way (see "Disposal").
- Calibrate the scale, see "Setting up the scale".

Choosing the unit of measurement

The standard unit of measurement upon delivery is "kg" (kilogramme). However, the measurement can also be displayed in the English unit of measurement "lb" (pounds).

  1. To switch on the scale, step on the middle of the weighing surface.
  2. Use the UNIT button on the back of the scale to set the desired unit of measurement. Note the display.

Setting up the scale

  1. Place the scale on an even, firm and dry surface. Do not place the scale on a carpet.
  2. First, briefly step onto the middle of the weighing surface to calibrate the scale. As soon as the display shows "0.0", calibration is complete. This calibration must be performed after each battery change.

ADE Suki BE 1909 - Setting up the scale - 1

WARNING against injuries

  • Do not step onto the scale with wet feet or when its surface is damp. Risk of slipping!

  • Position yourself on the scale. Stand still and do not hold on to anything.

The measured weight will be displayed shortly thereafter.

A few seconds after you step off the weighing surface, the scale will switch off automatically.

ADE Suki BE 1909 - WARNING against injuries - 1

  • Weigh yourself with as little clothing on as possible.
  • Try to always weigh yourself at the same time and under consistent conditions in order to obtain comparable values.

Resetting the scale

Reset the scale to its default settings if unusual or obviously incorrect values are shown on the display.

  1. Remove the batteries from the battery compartment and wait a moment.
  2. Reinsert the batteries.

Pay attention to the correct polarity of the batteries (+ / - )

After switching the scale on, you can weigh yourself as usual.

Cleaning

ADE Suki BE 1909 - Cleaning - 1

NOTE on material damage

-Do not immerse the scale in water or other liquids.

  • Never use harsh, scouring or abrasive cleaning agents or the like to clean the scale. Otherwise, the surface could be scratched.

  • Wipe the scale as needed with a slightly damp soft cloth.

  • Disinfect the weighing surface from time to time using a suitable disinfecting agent (available at specialist retailers and pharmacies).

Fault/Remedy

Fault Possible cause
No function·Are the batteries empty or inserted the wrong way around?
The scale appears to be displaying wrong weighing results·Is the scale located on a firm, even surface? ·Is a device that can cause electromagnetic disturbances located in the vicinity of the scale? ·Remove the batteries from the scale and wait a moment. Reinsert the batteries.
"Err" is shown on the display·The maximum capacity of the scale (180 kg) has been exceeded.
"Lo" is shown on the display·The batteries are empty (see "Inserting/changing batteries").
"C" is shown on the display·The weighing/measurement process was faulty: The scale is not stable or you are not standing still on the weighing surface during weighing. Repeat the process.

Technical data

Model: Digital bathroom scale BE 1909 "Suki"

Battery: 3x LR03 (AAA)/1.5 V=

Rated current: ≤ 50mA

Measuring range: max. 180kg

Variance: 1% + / - 100g

Display scaling: < 100kg = 50g

>100kg = 100g

Scale dimensions: approx. 300 × 300 × 20.5 ~mm

Distributor (no service address): Waagen-Schmitt GmbH

Hammer Steindamm 27-29

22089 Hamburg, Germany

Our products are constantly being developed and improved.

For this reason, design and technical modifications are possible at any time.

Waagen-Schmitt GmbH hereby declares that the electronic bathroom scale BE 1909 complies with EU directives 2014/30/EU and 2011/65/EU. This declaration will lose its validity if any modification is made to the scale without our consent.

Hamburg, December 2019

Waagen-Schmitt GmbH

ADE Suki BE 1909 - Technical data - 1

Warranty

Waagen-Schmitt GmbH warrants for 2 years from the purchase date the cost-free rectification of defects in material and workmanship through repair or exchange.

In the event of a warranty claim, please return the product with the proof of purchase (specifying the reason for claim) to your dealer.

Disposal

Disposing of the packaging

ADE Suki BE 1909 - Disposing of the packaging - 1

Dispose of the packaging with similar materials. Dispose of cardboard and carton as waste paper and of films to the collection point.

Disposing of the product

Dispose of the product in accordance with the regulations that apply in your country.

ADE Suki BE 1909 - Disposing of the product - 1

Devices must not be disposed of in normal household waste.

At the end of its life, the product must be disposed of in an appropriate way. In this way, valuable materials contained in the device will be recycled and the burden on the environment avoided. Bring the old device to a collection point for electronic waste or to a recycling depot. For more information, contact your local waste disposal firm or your local administrative body.

ADE Suki BE 1909 - Devices must not be disposed of in normal household waste. - 1

Batteries and rechargeable batteries should not be disposed of in the household waste.

All batteries and rechargeable batteries must be brought to a local or district collection point or to the retailer. Such batteries and rechargeable batteries can thus be disposed of in an environmentally friendly way.

;Estimada/o cliente/e!

Chere cliente, cher client!

Pile: 3 × LR03 (AAA) / 1,5 V = -

Intensité nominale: ≤ 50 mA

Plage de mesure: Max. 180 kg

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : ADE

Model : Suki BE 1909

Category : Scale