JG 1000 E - Water pump Güde - Free user manual and instructions
Find the device manual for free JG 1000 E Güde in PDF.
User questions about JG 1000 E Güde
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Water pump in PDF format for free! Find your manual JG 1000 E - Güde and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. JG 1000 E by Güde.
USER MANUAL JG 1000 E Güde
----EN Translation of the original instructions
natural_image
Blue and metallic industrial pump device with control panel and warning labels (no readable text in image)JG 1000 E
94657

ENGLISH Please read the instructions carefully before starting the machine.
natural_image
Blue and metallic industrial pump labeled 'JG 1000 E' with control panel and warning labels (no readable text beyond label)DE INBETRIEBNAHME HU ÜZEMBE HELYEZÉS
GB STARTING-UP THE MACHINE PL URUCHOMIENIE
FR MISE EN SERVICE
natural_image
Mechanical component with blue cap and black base, no visible text or symbols2
natural_image
Close-up of a mechanical component with green connectors and arrows indicating assembly (no visible text or symbols)3
natural_image
Illustration of a blue gas condenser with a thermometer and red temperature scale indicator (no text or symbols on the device itself)4
DE BETRIEB HU ÜZEMELTETÉS
GB OPERATION PL EKSPLOATACJA
FR FONCTIONNEMENT
IT ESERCIZIO
NL GEBRUIK
CZ PROVOZ
SK PREVÁDZKA

text_image
START STOP5
DE TRANSPORT / AUFBEWAHRUNG HU SZÁLLÍTÁS / TÁROLÁS
GB TRANSPORT / STORAGE PL PRZEWÓZ / PRZECHOWANIE
FR TRANSPORT/STOCKAGE
IT TRASPORTO / STOCCAGGIO
NL TRANSPORT / BEWARING
natural_image
Silhouette of a person running away from a window with two blue objects, no text or symbols present10
DE INBETRIEBNAHME HU ÜZEMBE HELYEZÉS
GB STARTING-UP THE MACHINE PL ÜZEMBE HELYEZÉS
FR MISE EN SERVICE
natural_image
Close-up of a blue cylindrical mechanical component with a downward arrow indicating motion (no text or symbols visible)
JG 1000 E

text_image
> 0° | < 40°
text_image
V min. 400 mm
text_image
Diagram illustrating a mechanical or fluid system with warning symbols and directional arrows, including a warning symbol with an exclamation mark.| DE | ANSCHLUSS | HU | FESZÜLTSÉG | ![]() |
| GB | SERVICE CONNECTION | PL | POŁĄCZENIE | |
| FR | ALIMENTATION | |||
| IT | ALLACCIAMENTO | |||
| NL | AANSLUITING | |||
| CZ | PRÍPOJKA | |||
| SK | PRÍPOJKA |


JG 1000 E

text_image
A B
text_image
TIP KA 4 P / 94440 KA 7 P / 94441 A
text_image
1 A + B
text_image
2 A
text_image
3 A B
natural_image
Mechanical device with blue housing and black tubing, showing fluid flow direction (no text or symbols)| DE | ÜBERLASTUNGSSCHUTZ | HU | TÜLTERHELÉS ELLENI VÉDELEM | |
| GB | ENGINE PROTECTION | PL | ZABEZPIECZENIE PRZED PRZECIĄŻENIEM | ![]() |
| FR | PROTECTION CONTRE LA SURCHARGE | |||
| IT | PROTEZIONE CONTRO I SOVRACCARICHI | |||
| NL | OVERBELASTINGSBEVEILIGING | |||
| CZ | OCHRANA PROTI PŘETÍŽENÍ | |||
| SK | OCHRANA PROTI PREŤAŽENIU |

JG 1000 E

text_image
1 | START ON
text_image
Diagram illustrating a water pump system with warning symbols and a magnified inset showing depth measurement of 10 cm.| DE BETRIEB HU ÜZEMELTETÉS |
| GB OPERATION PL EKSPLOATACJA |
| FR FONCTIONNEMENT |
| IT ESERCIZIO |
| NL GEBRUIK |
| CZ PROVOZ |
| SK PREVÁDZKA |

JG 1000 E

text_image
Diagram illustrating a scientific apparatus setup with labeled components and a 10 cm minimum clearance indicator.
text_image
2 STOP OFF bude| DE | TRANSPORT / AUFBEWAHRUNG | HU | SZÁLLÍTÁS / TÁROLÁS |
| GB | TRANSPORT / STORAGE | PL | PRZEWÓZ / PRZECHOWANIE |
| FR | TRANSPORT / STOCKAGE | ||
| IT | TRASPORTO / STOCCAGGIO | ||
| NL | TRANSPORT / BEWARING | ||
| CZ | PŘEPRAVA / ULOŽENÍ | ||
| SK | TRANSPORT / ULOŽENIE |


JG 1000 E

text_image
1 ONOFF
text_image
2 STOP
text_image
3
natural_image
Close-up of a blue industrial machine with a hand holding it, showing a blade and triangular blades (no text or symbols visible)
text_image
5 No Snow No NoTechnische Daten
Garden pump JG 1000 E
Art. No....94657
Supplz Voltage 230V / 50Hz
Motor capacity P1 1000 W
Max. delivered quantity....3600 l/h
Max. head of delivery 42 m
Max. suction height....8 m
Max. Water temperature....35°C
Thread hose connection....1" IG
IPX4 Protection class....IPX4
Weight....8,82 kg
Sound power level....83dB


Read and understand the operating instructions before using the appliance. Familiarise with the
control elements and how to use the appliance properly. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties.
The operator is responsible for accidents or risks to third parties.
In case of any doubts about connection and operation refer please to our customer center
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
Specified Conditions Of Use
The pump is designed for pumping clean water only to supply the home with water and to use it at home, in garden, courtyard and for fields. Respecting technical data and safety precautions.
Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.
The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is curtailed correspondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
⚠ Do not use the pump for drinking water!
The pump must not be connected to the existing water-supply network as a pressure-boosting device.
⚠️ Never use the pump as a pool circulation pump.
Safety Instructions
WARNING!
Electric shock! There is a risk of an injury caused by electric shock!
This device is not intended for use by persons (including children) with limited physical, sensory or mental capabilities or without the necessary lack experience or knowledge unless they are supervised by a person who is responsible for their safety or were instructed by that person in how to use the device.
Children should be supervised to ensure that they do not play with the device. Always keep children and unauthorised persons out of reach of the appliance.
Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA).
Before putting into operation, a qualified electrician must check whether electric safety measures required are in place. Any national regulations in this regard must be complied with.
Electric connection to a socket.
Do not expose the appliance to rain and do not use it in wet or moisture conditions.
It is necessary to make sure the connecting socket was not near water and humidity and the plug was protected against humidity.
Avoid installing the appliance in wet shafts (risk of short circuit, corrosion effects)!
Check the voltage. Technical data given on the type label must correspond with electric network voltage.
Only use splash proof extension cables approved for outdoor purposes.
Do not grab the feeder cable, plunge the pump, lift or
carry it while it is connected to the grid!
Check the cable and/or socket for damages before the appliance putting into operation.
To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself.
Protect the feeder cable from excessive temperatures, oil and sharp edges.
⚠️ If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.).
The pump must not in any case run without fillings.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
The temperature of the drained liquid must not exceed +35 °C.
When using the pump for domestic water supply, always observe the local regulations of water management authorities and the waste water drainage.
If the pump is used in ponds, wells, etc. and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed.
Do not use pump at outside temperatures over 40 °C or under 0 °C
In cold weather, the pumping body motor should not bewrapped in a blanket or another piece of textile with intent to prevent the water freezing.
The user is responsible to third parties if pump (dumping stations, etc.) is used.
Requirements for operating staff
The operating staff must carefully read the Operating Instructions before using the appliance.
Qualification: Apart from the detailed instructions by a professional, no special qualification is necessary for appliance using.
Minimum age: Persons over 16 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education.
Training: Using the appliance only requires corre-
sponding training by a professional or the Operating Instructions. No special training is necessary.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. For the sake of eventual accident, in accordance with DIN 13164, a workplace has to be fitted with a first-aid kit. It is essential to replace any used material in the first-aid kit immediately after it has been used. If you seek help, state the following pieces of information:
- Accident site
- Accident type
- Number of injured persons
- Injury type(s)
Maintenance
⚠️ Before carrying out any work on the machine, disconnect the plug from the socket.
Prior to every use, visually check the machine to rule out any defects, in particular on the power cable and the plug.
The machine must not be used under any circumstances if the machine or the safety devices are damaged.
Refer all servicing to customer service. Use only original accessories and original spare parts.
Caution: Standing water may corrode (brownish colour) in the pump according to design.
At winter storing, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance. Prior to transportation, it is necessary to unplug the pump from the grid! The device has to be completely emptied and stored with frost-proof protection. Adhesion of mechanical seals can be prevented if you rinse the pump with appropriate oil (for example, with vegetable oil).
Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.
Guarantee
Guarantee claims as per guarantee card attached. The guarantee solely covers inadequacies caused by material defect or manufacturing defect. Original payment voucher with the sales date needs to be submitted for any claim in the guarantee period.
The guarantee does not cover any unauthorised use such as appliance overloading, use of violence, damage as a result of any unauthorised interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee..
GÜDE cannot be held responsible for damages incurred in consequence of unqualified installation or unskilled handling of the pump.
The device has to be checked on a regular basis to ensure perfect functioning.
Let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the below-mentioned cases:
- Unprofessional repairs executed by unauthorised service centres;
- Use in conflict with the designed purpose, or failure to observe the use as designed;
- Pump overload with a continuous run;
- Damage as a result of icing or any other fault caused by climatic influences;
Identical regulations apply for accessory parts.
To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).
Service
Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? We will quickly help you and without needles bureaucracy at our web pages at www.guede.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label. Please enter it here for future reference:
Serial No.:
Art. No:
Year of production:
Symbols

Read the Operating Instructions

Before carrying out any work on the machine, disconnect the plug from the socket.

Cable pulling / transport prohibited

Staying in the transportation medium prohibited

Warning against dangerous electric voltage

Warning against automatic starting

Accessory - Not included in standard equipment, available as an accessory.

Any damaged or disposed electric or electronic devices must be delivered to appropriate collection centres.

Protect against humidity

This side up
Inspection and maintenance plan
Time interval Description Any other details
As needed Clean the check valve. Check the check valve function.
Failures – causes - removal
Failures Causes Removal
| Engine does not start No power supply. Blocked pump wheel | Turn the engine shaft with screwdriver through the fan cover (to release friction circles sealing that may be stuck together). | |
| Pump does not suck Missing, loose or blocked check valve Check valve is not in water. Pump without water Too high suction head. Air bubbles in the suction pipeline. Connections not sealed, pump sucks air, pump is not deaerated. | Fix or clean the check valve. Immerse the check valve into water. Fill the pump shell with water. Check the suction head. Check the tighten of suction pipeline. Carefully repeat connection according to the chapter „Connection“! | |
| Thermal detector switching the pump off → “4 | Pump is overheated and switched off by the thermal overloading protection. No electric power supply. Impurity particles (e.g. pebbles) have settled down in the suction hole. | Let the device getting cool! Check power supply. Disassemble and clean the suction hose, prevent from suction of foreign substances. |
| Insufficient amount of water pumped | Too high suction head. Strainer of the check valve dirty Water level quickly drops down | Check the suction head. Clean the strainer., Position the check valve lower. Clean the pump and replace worn parts. (qualified workshop) |
Translation of the EC-Declaration of Conformity
We, hereby declare the conception and construction of the below mentioned appliances correspond - at the type of construction being launched - to appropriate basic safety and hygienic requirements of EC Directives.