LifeAir IonFlow Solution - Air purifier

IonFlow Solution - Air purifier LifeAir - Free user manual and instructions

Find the device manual for free IonFlow Solution LifeAir in PDF.

📄 76 pages English EN Download 💬 AI Question 8 questions ⚙️ Specs
Notice LifeAir IonFlow Solution - page 2
Pick your language and provide your email: we'll send you a specifically translated version.
Feature Details
Product type Air purifier
Purification technology Negative ions to remove pollutant particles
Coverage area Up to 50 m²
Noise level Quiet, suitable for nighttime use
Energy consumption Low consumption, energy efficient
Filtration No filters to replace, minimal maintenance
Usage Easy to use with a single power button
Maintenance Regular cleaning of the outer grille recommended
Safety Certified compliant with electrical safety standards
Dimensions Compact, easy to move
Weight Lightweight, easy to carry
Warranty 2-year warranty
Additional information Ideal for allergy sufferers and families with children

Frequently Asked Questions - IonFlow Solution LifeAir

How does the LifeAir IonFlow air purifier work?
The LifeAir IonFlow air purifier works by emitting negative ions that attract and neutralize pollution particles, allergens, and pathogens present in the air.
What is the coverage area of the LifeAir IonFlow purifier?
The LifeAir IonFlow purifier is designed to cover an area of up to 50 m², making it ideal for living rooms, bedrooms, and offices.
Does the LifeAir IonFlow purifier produce noise?
The LifeAir IonFlow purifier operates quietly, making it suitable for use in quiet environments such as bedrooms.
How do I clean the LifeAir IonFlow air purifier?
To clean the purifier, turn it off and unplug it. Use a soft, damp cloth to wipe the exterior of the device. Do not immerse the purifier in water.
Does the LifeAir IonFlow purifier require replacement filters?
No, the LifeAir IonFlow purifier uses ionic technology that does not require replacement filters, reducing maintenance costs.
Is it safe to use the LifeAir IonFlow purifier around children and pets?
Yes, the LifeAir IonFlow purifier is safe to use around children and pets as it does not emit harmful chemicals and does not produce ozone.
How can I tell if my air purifier is working properly?
You can check if your LifeAir IonFlow purifier is working properly by observing the air quality in the room, which should improve over time. Additionally, a LED indicator light may signal its operating status.
Are there any precautions to take when using the LifeAir IonFlow purifier?
It is recommended to place the purifier in a well-ventilated area and avoid covering it with objects to ensure optimal air circulation.

User questions about IonFlow Solution LifeAir

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air purifier in PDF format for free! Find your manual IonFlow Solution - LifeAir and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. IonFlow Solution by LifeAir.

USER MANUAL IonFlow Solution LifeAir

IonFlow Signature IonFlow Evolution IonFlow Evolution Gold IonFlow 500

ENGLISH

NEDERLANDS

POLSKI

中文(繁體)

DEUTSCH

SVENSKA

TÜRKÖE

中文(简体)

FRANÇAIS

DANSK

LifeAir IonFlow Solution - IonFlow Signature   IonFlow Evolution   IonFlow Evolution Gold   IonFlow 500 - 1

中国

ESPANOL

NORSK

PYCCKN

ITALIANO

SUOMI

日本語

LAIFST

LAIFST-001

LAIFEV

LAIFEV-050502

LAIFSU2

SAFETY INSTRUCTIONS

Please read through the instructions before using this air purifier and keep this instruction manual in a safe place.

Guide for installation is found on page 74 (sketches).

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.

Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Ensure that the connected voltage supply is the same as marked on the rating label.

The appliance is only to be used with power supply unit provided with appliance.

The air purifier is an electrical appliance and should be treated as such. Be particularly careful to avoid accidents during installation, use, and maintenance.

The air purifier should be installed and cleaned by adults.

The air purifier should be installed according to the instructions, at the correct distance from a wall and placed on a secured and stable surface. If incorrectly placed, the air purifier may fall and cause injury to people or damage to its surroundings.

We recommend that you place the 500/Signature/Evolution models at least 3 feet (1 meter) away from all walls and furniture. If these recommendations are not followed, nearby walls and/or furniture may become somewhat dirty.

LifeAir IonFlow Solution - SAFETY INSTRUCTIONS - 1

Never use the air purifier with a damaged power cable, damaged transformer or damaged electronics.

If the main lead is damaged it must be replaced by a qualified person.

To prevent from electric shock, fire, personal injury and any other hazard

do not immerse the air purifier including the transformer into water or any other liquid.

Do not place the air purifier or cable near a heat source.

Do not use the air purifier outdoors.

Do not use the air purifier in damp rooms.

Do not use the air purifier in conjunction with coloured or oil-based candles, as they emit soot which can become attached to walls and furniture.

You may experience a small electric discharge when touching the collector. This is harmless! If you find this discharge unpleasant, unplug the appliance before handling it and use the protective guard when the air purifier is on. Note that the protective guard is optional and not necessary from a safety perspective.

Note: LifeAir cannot be held responsible for any damage caused as a result of failure to follow the recommendations.

PRODUCT DESCRIPTION

IonFlow 500, Signature & Evolution:

1 ion generator (above= 3 corona needles, below=outlet and metal hook)
1 particle collector
1 acrylic stand
1 switch
1 transformer
4 decorative lights
1 protective guard (32 slats and 2 assembly rings)
1 corona needle brush

CLEANING AND MAINTENANCE

You MUST disconnect the power supply and turn off the air purifier before cleaning.

Do NOT wash the collector in the dishwasher.

Do NOT use cleaning products that contain alcohol solutions, ammonia, or alkaline substances, as these products may damage the air purifier.

The collector should be cleaned approx. once every two weeks or when needed. The collector may require more frequent cleaning if used in highly contaminated environments.

LifeAir IonFlow Solution - CLEANING AND MAINTENANCE - 1

Cleaning the collector:

  1. Clean the collector with washing-up liquid, water, and a soft sponge.

  2. Dry the collector with a dish towel.

  3. Put the collector back on the ion generator according to the above instructions.

If you have followed the above instructions but the collector is still not clean, try the following:

  1. Spray detergent onto the collector and let it work for 5 minutes.
  2. Use a damp sponge and rub any remaining spots until they disappear.
  3. Dry the collector with a dish towel and place it back on the ion generator according to the above instructions.
  4. Repeat the above procedure if necessary.

LifeAir IonFlow Solution - If you have followed the above instructions but the collector is still not clean, try the following: - 1

Cleaning the ion generator, corona needles and acrylic stand:

Once every two months you should carefully clean the fragile corona needles. Use the small brush that is included in the package and carefully brush away the thin layer of white lime scale and dirt, which may have become attached to the needles. Do not use pressure or water when you clean the needles.

Clean the ion generator and the acrylic stand

with a damp cloth or sponge. Wipe clean and rub away any remaining dirt and dry with a towel. Do not allow the top and bottom of the ion generator to come into contact with water and be careful with the corona needles.

ACCESSORIES IONFLOW 500, SIGNATURE, & EVOLUTION:

4 Decorative lights Protective guard

LifeAir IonFlow Solution - Decorative lights Protective guard - 1

LifeAir IonFlow Solution - Decorative lights Protective guard - 2

LifeAir IonFlow Solution - Decorative lights Protective guard - 3

LifeAir IonFlow Solution - Decorative lights Protective guard - 4

LifeAir IonFlow Solution - Decorative lights Protective guard - 5

LifeAir IonFlow Solution - Decorative lights Protective guard - 6

For warranty see www.lifeair.com

Correct disposal of this product: This marking indicates that this product should

not be disposed with other household wastes throughout the EU. To prevent

possible harm to the environment or human health from uncontrolled waste

disposal, recycle it responsibly to promote the sustainable reuse of material

resources. To return your used device, please use the return and collection

systems or contact the retailer where the product was purchased . They can take

this product for environmental safe recycling.

LifeAir IonFlow Solution - For warranty see www.lifeair.com - 1

LifeAir IonFlow Solution - For warranty see www.lifeair.com - 2

SICHERHEITSHINWEISE

IonFlow 500, Signature, Evolution:

IonFlow 500, Signature & Evolution:

ACCESSORI ONFLOW 500, SIGNATURE, & EVOLUTION:

BESCHRIJVING VAN HET PRODUCT

IonFlow 500, Signature & Evolution:

TILBEHØR IONFLOW 500, SIGNATURE, & EVOLUTION:

4 dekorative lys Sikkerhedsskaerm

LifeAir IonFlow Solution - TILBEHØR IONFLOW 500, SIGNATURE, & EVOLUTION: - 1

LifeAir IonFlow Solution - TILBEHØR IONFLOW 500, SIGNATURE, & EVOLUTION: - 2

LifeAir IonFlow Solution - TILBEHØR IONFLOW 500, SIGNATURE, & EVOLUTION: - 3

LifeAir IonFlow Solution - TILBEHØR IONFLOW 500, SIGNATURE, & EVOLUTION: - 4

For garanti se www.lifecair.com

RENGJØRING OG VEDLIKEHOLD

Strømforsyningen Må vare frakoblet og luftrenseren Må vare avslätt før rengjöring.

IKKE vask beholderen i oppvaskmaskin.

IonFlow 500, Signature i Evolution:

IonFlow 500, Signature & Evolution:

1 iyon uretici (ust= 3 korona igneler, alt= menfez ve metal kanca)
1 toplayici
1 akrilik stand
1 anahtar
1 transformation
4 dekoratif 1sik
1 koruma muhafazasi (32 cita ve 2 baglanti cemberi)
1 korona igne fircasi

TEMIZLEME VE BAKIM

J 1234567890
8890
8890
8890
8890
8890
8890
8890
8890
8890
8890
8890

21

1

Signature, Evolution, 500 IonFlow

LifeAir IonFlow Solution - TEMIZLEME VE BAKIM - 1
ylaolcbc

LifeAir IonFlow Solution - TEMIZLEME VE BAKIM - 2
4

LifeAir IonFlow Solution - TEMIZLEME VE BAKIM - 3

LifeAir IonFlow Solution - TEMIZLEME VE BAKIM - 4

LifeAir IonFlow Solution - TEMIZLEME VE BAKIM - 5

www.lifeair.com

LifeAir IonFlow Solution - TEMIZLEME VE BAKIM - 6

aal l aall pae yll alal l 1s y: tll l n no aall qall

ciiil ciaolgo

Signature & Evolution, 500 IonFlow

():13c:g)

(j)

odell Jolz 1

a11

1

4

1

()32)

aillg a

iill jie jy 111 111 111 111 111

Jusall Jue (julll) jaiy

y

a

()

i 1 (j) a

LifeAir IonFlow Solution - aillg a - 1

()

Jie (jil) 1

aclla aiaolgolall gil

2

3

0x18gssll lallaill g g 1g

0x18siall lalil iis 1

5 1g 50

2

3

.0x1 2

4

INHCTPYKUNI NO TEXHNIKE B3OJACHOCTN.

IoxaJyncTa, npeed hauanom nCNoJIb3OBaHnry OUNCHTeJIYBO3dYxa, npouHTaIte 3Ty INHCTpyKcIIO n COxpaHNTe eB HaNEDJXHom MeCTe.

PykoBoDCTBO NO MOHTaJy MoJHo HaIaTn Ha cTpaHnCe 74 (Yeptexn).

3TO yCTPOICTBO MOrT hONb3OBaTb DeTn BO3pactOM OT 8 let n IIOIN C ORpaHnueHHbIMN cH3nueCKIMN, CEHCOPHBIMN nII IN YMCTBeHHbIMN CNOCO6HOCTaMn, IINoC HEDOCTaTOUHbIM ONbITOM nII 3HaHnAIMN, TOJIbKO IOI npNCMOTpOM nIIN PocNe pOnyehnY kA3aHnN NO 6e30NaChOMy NCNOJb3OBaHnIO yCTPOIcTBa N C NOHmAHnE M PNCKOB, C KOTOpBIMN CBra3aHO NCNOJb3OBaHne yCTPOIcTBa.

IeTN He DoJXHbI nrgaTb C yCTpoiCTBOM. DeTN He DoJXHbI OUnuTaB IIN o6cIyKnBaTb yCTpoiCTBO 6e3 npncmOTpa.

IpoBepbTe npaBnIbHocTb IOnaBaEMoHaInpJxHEny, CBepNB erO C MapKnipOBKoH a 3TuKeTke N3DeJIIny.

3TO yCTpOiCTBO DOJXHO IcNoJIb3OBaTbcra TOnIbKO C 6JOKOM 3JIeKTPoPiTaHnI, PpeIOCTaBJIeHHbIM BMeCTe C HnM.

OuHCTnTeIb BO3dUxA YBJIaETcA 3JIeKTpUYeCKM yCTpOiCTBOM I C HIM DOJXHO 6bITb COOTBeTCTByIOUeE o6paUeHne.ДЯ npEduPexJdeHna HeCuaCThblx cIyuaEB, 6yIbTe Oco6eHNO OCTOpOXHbI BO BpeMa yCTaHOBKn, 3KcIIpyaTaunN IO6cIyXuBaHnN n3DeHnra.

OuHCTIeJIb BO3dUxa DOJxEh 6bITb yCTaHOBJIeH IOuNtA TbCBaB3pOcJIbIMN JIODbMI.

OuHCTnTeJIb BO3dUxA DOJKeH 6bITb yCTaHOBJIeH B COOTBeTCTBnC INHCTpyKzIyMn, Ha Tpe6byemOM pacCToAHN OT CTeHbI n pacNoJaTaBcR HA yCToINBOi, HADEXKHOI NOBepXHOCTN. B Cnyuae HENpaBnJIbHOJ YCTaHOBKn, OuHCTnTeJIb BO3dUxA MOKeT yNaCTb N HaHeCTN TpaBMbl NepcoHaJy I NOBPeIDHTb INHTepbpE NOMeIeHna.

Mbl pekomehnyem pacnojaraTb
moden 500/Signature/Evolu tion ha paccToHn MNHmym 1
MeTpa OT cTeH n Me6eH. EcIn 3TN
pekomeHaaun He co6JIoDaIOTcra,
TO NOBepxHOCTn CTen/Me6eHn
OKOIO OUnCTHTeJr MOryT 6bITb
3aqr3HHeHHbIMn Upe3 HeKOTOpbI
NepnoD erO 3KcPnyataun.

LifeAir IonFlow Solution - INHCTPYKUNI NO TEXHNIKE B3OJACHOCTN. - 1

HnkOrda He nCNoJb3yIte OunchTeJIb BO3dUxa C NOBpeKdEHHbIM Ka6eJem, TpaHcΦopMaTopOM IJIH HeNCnPabHBbIMn DeTaJIaMn

3JIeKTPoHnHO ynpaBneHnA.

B clyuae noBpeKdEHHraBnHO Ka6eJ, OH doJxH 6bItb 3aMeHcneuaJIncTOM, IMeUoIIM IuCeH3NIO Ha npOBeHeHne TaKnx pa60T.

Дпя пеiodOTВрашени OT удара злелКтчecKM TOKOM, пожара, ФизчecкIX TpaBM ИИN Дугнх HechacTHbIX CnyuaeB, He nOrgykaIte OuchTeJIb BO3dUxa I TpaHcФopMaTOP B BODY ИИN KaKyHO-Jn6O dpyrHyO XnIDKOCTb.

He pacnonarai Te ouinTeB Bo3dyxa nn Ka6eB OKOLO nCTouHnKa Tenna.

He nCnoIb3yIe OunCTnTeIb BO3dyXa BHe NOMEuEHHa.

He nCnoIb3yIe OunCTnTeIb BO3dyXa B nbIbHOM NOMEueHIn.

He nCnoJIb3yIe OunCTnTeJIb BO3dUxa B NOMEuEHN BMeCTe C CBETbIMN IJI N3rOToBJIeHHbIMN C pPImecaMn Macna CBeaAMn, TaK KaK OHI BblJeJIaIOT CaJy, OKpaUNBaIOUyHO CTeHbI N Me6eJIb.

При прикасани К коллектopy, Вbl може Te NOJyHTb He6OJIbшо J3JIeKTPnueckn pa3pI. 3TO He npedCTaBJIeT HnKaKOJ onaChocTn! EcII n3ToT pa3pI NOKaKeTcB Bam HeNPraTHbIM, TO BbIHbTe IITeNcJIb I3 PO3ETKn pepeI pRikacAHem K OUHCTInTeJIIO IN NCNoJIb3yIte 3aUHTbI KOKyx, ecII OUnCTInTeJIb BO3dYxa BKJIouYeH. 3aMeTbTe, YTO 3aUHTbI KOKyxЯВЯETcR OUNHOHaJIbHbIM O6OpyIDOBaHNeM I He O6aTeJIeH C ToUKN 3peHnRA 6e3ONaCHOCtN.

Пп汞анue: LifeAir He Hecem omeemcmeHHocmu 3a Лобье hapyuelsen u mpaMbl, 603Hukwue ecneodcmeue He npabuIbHo2o cneodobahru pekomehdaucma.

Описане Издения

IonFlow 500, Signature & Evolution:

1 noHHbI reHepaTop (BBepyx = 3 nJIbIKopoHbI, BHN3y=BbIXOД mMeTaIIHuecko KpIOK)
1 KollnEeTOp
1akpniloBaIpoCTaBka
1 BbIKIIOuAteNb
1 TpaHcΦopMaTop
4ДeKopaTnBbIXЯmN
1 ceHcOpHbI KOKxy (32 nlaHKn u 2 c6OpHbIX KOJIbua)
1 ueTka dIra OCHCTKIN IROJIOK KOPOHbI

OuNTKA N OBCJIyXINBAHNE

Ipeed OocntKoOocntTeJb BO3dyxa, Bbl OJXHbI OTcoeDnHTb Noady NtTaHna Ha OocntTeB Bo3dyxa.

HE MoTe KOJIneKTop B IocyIDOMOeHNo MauINHe.

He nCnoJb3yIte OunchTeJIbHbIe cpeICTBa, coJePkaUne pactBop aIKKOrONa, HauTaTbIPHbI CNInPT INN anKaIOniNDhIbe cy6CTAHuN, TAK KAk 3TN cpeCTBa MOrY TIOBpeNTb OunchTeJIb BO3dyXa.

KoJIeKTOp DOnJKeH OChIaTbCp npIMepHo OOnH pa3 B DBe HeJeIIN IIN Prn HeO6XoDImocTn. B Cnyae INcIOJIb3OBaHnI N3DeJIINB NOMEUeHNi C NOBblJEHHbIM 3aRpy3HeHnEM BO3dYxa, MoKet Tpe6oBaTbCg BoJee YacTaI OUnCTka.

OuncTkKa KonneKTopa:

  1. Ouchntte KollnEeTOp MOUeien KNDKoCTbH, BODoI, NcNoJIb3yra ry6ky.
  2. IpoTpnte KOJIneKTop KxOHhbIM NOIToHEIeM.
  3. YctaHOBNTe KOJIIEKTO Ha MeCTO Ha NOHHbI reHepaTOp, KAK yKa3aHO B INHCTpyKUNBblJE.

Ecnu 6bl npoeenu paobmbl coombemcmbuu c bIweepueedHbIMU uHcmpykuaymu, Ho KJInekmop 6e Je HeodomamooHo yucmbu, nonpobyume cdenamb cneyuouee:

LifeAir IonFlow Solution - OuncTkKa KonneKTopa: - 1

  1. PacnbIInTe MOUeB BeueCTBO Ha KOJIneKTop n octaBBte ero Ha 5 MNHT.
  2. NcnoIb3yra 6ky, npotnpaTe octabuinec3aIrp3HHeHHbIe MeCTa Do Tex nop, noka rpa3b HeNCue3HeT.
  3. IpoTpnte KOnIeKToP HAcyxo KyxOHhbIM NOJIoTeHcEm n pacNoJIoxKIne erO Ha NOnHbI INreHepaTop B COOTBeTCTBn C BblWeIpNBeDeHHbIMN INHCtpyKUmaMn.
  4. Пи Heo6xOДIMOCTN, NOBTOPe BbIeYka3aHHyIO npoceDpy.

OuHCTKa HONHOro reHepaTopa, HROJOK KOpOHbI N akpHIOBOI NOCDtABKn:

Odn pa3 B DbA MecraHa Heo6xOIMTOaTeNbHO OunuTb XpyKHe HroJKN KopoHbI. NcNoB3yA He6oNbUO uETKy, npnlaRaemyo K ynaKOBKe, OCTopoxHo ydaJIte rpa3b N TOHKn CNOI bEnoJ KupHOu 3BecTu, KOtOpaR, BO3MOXHO, OCTaNaCb Ha IROJkax. Jnry ONUCTKn IROJOK He pa3peWaeTcR npmehrTa CKaTbI BO3dyX INI BODY

OuHuaTe MoHHbI rHepaTOp n akpUIOBByIO NOCTaBky KcKOM MraKoT KAHn Hnn r6ko. IpotPte HaNCTo, YdaJIbO OCTaTK 3aqrA3HeHn cyXm mNoJOTeHcEm. BybTe OCTopoxhbl B o6paueHn C nroIkaMn KOPOhbl N He dOnyckaTe IonoadaHn BObl Ha BepxHOIO N HxNHOIO NOBepxHOCTn rHepaTopa.

LifeAir IonFlow Solution - OuHCTKa HONHOro reHepaTopa, HROJOK KOpOHbI N akpHIOBOI NOCDtABKn: - 1

AKCECCYAPbI IONFLOW MOdEJIb I IOBEPXHOCTb

4 DEKOPATNBbIX JAMN 3AUHTBbIK KOKyX

LifeAir IonFlow Solution - DEKOPATNBbIX JAMN 3AUHTBbIK KOKyX - 1

LifeAir IonFlow Solution - DEKOPATNBbIX JAMN 3AUHTBbIK KOKyX - 2

LifeAir IonFlow Solution - DEKOPATNBbIX JAMN 3AUHTBbIK KOKyX - 3

YcnoBna rapaHTn m. Ha Be6-caTe www.lifear.com

LifeAir IonFlow Solution - YcnoBna rapaHTn m. Ha Be6-caTe www.lifear.com - 1

LifeAir IonFlow Solution - YcnoBna rapaHTn m. Ha Be6-caTe www.lifear.com - 2

IpaBnBnaYtINH3aunr 3TOro npOdykTa: 3Ta MapKnpoBka yKa3bIbaeT, YTO daHHbI INpOdyKT HeNb3y YNHHToxaTb BMeCTe C DpyIM X03RJCTBeHHbIM MyCOPOM Ha TeppNTOpN EC. YTo6bl IpeDIOBbATnB BO3MOXHOe PnUHNHeHne BpeDa OKpykaIOSe CpeDe Nn 3dOpOBbIO IIODe BCNEcTBVe HEKOHTPONIPyEMoro YNHHTOXeHnMyMCopa, YNHHTOXaTe OTxOdbI OTBeTCTBEHHO, CNOCOBCTByra PaUNHObHOYTNIN3aUnM MaTePnAIBhIX pecypcoB. YTo6bl CdaTb BaWe NCNOJB3OBAHHOe yCTPOINCTBO, NCNOJB3yInTe CNCTEmbl CdAnu nCbopA NN CBJXNTecb C IpoDAuCaAMN 3TOrO yCTPOINCTBa B TOM MeCTe, IDe npOdyKT 6bl npNo6peTeH. OHI CMOnyT pInHrTb 3TOT npOdyKT dJa 3KOJONHueCKN 6e3Onachoro YNHHTOXeHn.

LifeAir IonFlow Solution - YcnoBna rapaHTn m. Ha Be6-caTe www.lifear.com - 3

注意事項にて

IonFlow 500, Signature & Evolution:

才元生成器x1(上記=口一、下記=二、

=1

akulstndx1

sX1

变换器x1

装飾ライ卜x4

夕扣卡力一卜x1(斯拉卜X32 0上伊安森PRIINg x2)

口口卡二一卜用产x1

クリ一=トと×ntanns

IonFlow 500, Signature & Evolution:

iOnabnngtJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJiJi

克羅拉卡諾伊森達貝阿多隆韋的

[목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :]

4개상식조명선구 彼오명-가드

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 1

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 2

Correct disposal of this product: This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 3

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 4

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 5
4.

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 6
5.

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 7
6.

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 8
7.

This air cleaner complies with the federal ozone emissions limit. ARB CERTIFIED

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 9

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 10

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 11

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 12

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 13

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 14

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 15

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 16

LifeAir IonFlow Solution - [목재서리- IONFLOW 500, SIGNATURE, & EVOLUTION모름 :] - 17

This appliance complies with the European Directives for electromagnetic compatibility (EMC) 2014/30/EU and its revisions, as well as Low Voltage Directive (LVD) 2014/35/EU and its revisions.

This appliance complies with the WEEE-Directive 2012/19/EU on the disposal of electrical and electronic equipment (WEEE).

This product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibility to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retainer where the product was purchased. They can take this product for environmental safe recycling.

WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B ISM equipment, pursuant to Part 18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

REORIENT OR RELOCATE THE RECEIVING ANTENNA.
- INCREASE THE SEPARATION BETWEEN THE EQUIPMENT AND RECEIVER.
- CONNECT THE EQUIPMENT INTO AN OUTLET ON A CIRCUIT DIFFERENT FROM THAT TO WHICH THE RECEIVER IS CONNECTED.
- CONSULT THE DEALER OR AN EXPERIENCED RADIO TV TECHNICIAN FOR HELP.

Electrical rating: 12VDC (with class II AC/DC adaptor, input: 100 - 240VAC 50/60Hz 0.4A max., output: 12VDC 600 - 1000mA)

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : LifeAir

Model : IonFlow Solution

Category : Air purifier