Type de produitThermomètre digital
MarqueAlecto
ModèleBC07
Plage de mesure32,0°C à 42,9°C
Résolution de l'affichage0,1°C
Précision (35°C - 39°C)±0,1°C
Précision (hors plage)±0,2°C
Alarme de fièvre≥ 37,5°C (8 bips doubles)
Température normale< 37,5°C (4 bips)
Arrêt automatiqueEnviron 10 minutes
AlimentationPile 1,55 V LR41 ou SR41
Autonomie de la pileEnviron 2 ans
Dimensions (L × l × h)128 × 19 × 11 mm
Conditions d'utilisation10°C - 40°C, 30% - 85% HR
Conditions de stockage10°C - 60°C, 25% - 90% HR
Méthodes de mesureOrale, rectale, sous l'aisselle
Affichage de la dernière mesureOui (en maintenant la touche Marche/Arrêt)
Entretien et nettoyageNettoyer avec un chiffon doux et de l'alcool avant et après chaque usage
SécuritéGarder hors de portée des enfants, ne pas exposer à l'humidité ou à la poussière, ne pas démonter
Garantie24 mois

Frequently Asked Questions - BC07 ALECTO

How to use the Alecto BC07 thermometer?
Press the On/Off button to turn on. Wait until the display shows "Lo" and °C. Place the probe under the tongue, under the arm, or in the rectum depending on the method. Wait for the beeps: 4 beeps for normal temperature, 8 double beeps for fever (≥37.5°C). The measurement takes 6 to 20 seconds depending on the method.
What do the "Lo" and "Hi" displays on the screen mean?
"Lo" is displayed if the measured temperature is below 32.0°C. "Hi" is displayed if the temperature is ≥43.0°C. Check the thermometer placement and try again.
How to change the thermometer battery?
When the battery symbol appears, remove the battery compartment cover. Remove the protector. Use a non-metallic pointed object to remove the old battery. Insert a new LR41 or SR41 battery with the + side facing up. Replace the protector and cover.
What is the accuracy of the thermometer?
The accuracy is ±0.1°C between 35°C and 39°C, and ±0.2°C outside this range.
How to clean the thermometer?
Clean the probe with a soft cloth moistened with alcohol before and after each use. You can briefly hold the thermometer under water or in alcohol, but do not sterilize or immerse it.
What is the battery life?
The battery lasts approximately 2 years under normal use. The thermometer automatically turns off after about 10 minutes to save battery.
Is the thermometer waterproof?
The thermometer can be briefly held under water or in alcohol for cleaning, but it is not designed to be immersed. Avoid submerging it.
What is the difference between oral, rectal, and underarm measurements?
Rectal temperature is approximately 0.5°C higher than oral temperature. Underarm temperature is approximately 0.5°C lower than oral temperature. Normal oral temperature ranges from 36.1°C to 37.2°C.
How to view the last measured temperature?
Press and hold the On/Off button for 2 seconds. The last measured temperature is briefly displayed on the screen.
What to do if the thermometer does not turn on?
Check the battery. If the battery symbol is flashing, replace it. Make sure the battery is inserted correctly with the right side up. If the problem persists, contact your dealer.

User questions about BC07 ALECTO

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Thermometer in PDF format for free! Find your manual BC07 - ALECTO and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. BC07 by ALECTO.

USER MANUAL BC07 ALECTO

indication pile vide

INTRODUCTION

Pile: LR41, 192 ou SR41

1: temperature sensor
2: display
3: on/start/stop/memory/off button

37.8°

temperature display

37.8°F M

temperature display memory

ALECTO BC07 - INTRODUCTION - 1

lege batterij indicatie

INTRODUCTION

This Alecto thermometer is a digital thermometer developed to take your temperature as simply and accurately as possible. In order to get the most reliable results, these instructions must be followed accurately. For the most accurate temperature reading, we recommend using the thermometer rectally. Although the generally accepted 'normal' temperature is 37.0°C , body temperature can vary from 36.1°C to 37.2°C .

Fluctuations in temperature can be due to activities such as sports, smoking, eating and drinking, and also depend on the part of the body where the temperature is taken. When measured orally, the body temperature is generally 0.5°C lower than when measured rectally, while a temperature measured under the armpit is 1.0°C lower. Your temperature is lower in the morning than in the evening.

SPECIFICATIONS

Temperature range: 32.0°C - 42.9°C Low temperature display: temperature ≤ 32°C display: Lo°C
High temperature display: temperature ≥ 43.0°C , display: HI°C
Display resolution: 0.1°C Accuracy: 35°C - 39°C:± 0.1°C ≤ 35°C ≥ 39°C:± 0.2°C Fever alarm ≥ 37.5°C : 8 double beep tones
Normal temperature ≤ 37.5°C : 4 beep tones
Switches off automatically: 10 minutes ± 2 minutes
Battery: LR41, 192 or SR41
Battery life: 2 years
Dimensions: 128 × 19 × 11mm Conditions for use: Temperature: 10°C - 40°C Humidity: 30% -85% RH
Storage conditions: Temperature: 10°C - 60°C Humidity: 25% -90% RH

MEASURING YOUR TEMPERATURE

  1. Press the ON/OFF key once to activate the thermometer. You will hear a beep and the display will show 188.8° C for around 2 seconds. If you continue to press the ON/OFF switch for 2 seconds, the last temperature measured will be displayed.
  2. The thermometer will now display a temperature of 36.5°C .
  3. When you see 'Lo' and °C' in the display, the thermometer is ready for use. If the room temperature is higher than 32.0°C , the room temperature will be shown instead of 'Lo'.
  4. Place the thermometer in the chosen body part to measure your temperature.
  5. When you hear a beep, your temperature has been recorded.

  6. if your body temperature is normal, you will hear 4 beeps

  7. if your body temperature is above normal (≥ 37.5°C) , you will hear 8 double beeps.

  8. Press the ON/OFF key to switch off the thermometer. (The thermometer will switch off automatically after approx. 10 minutes).

Measurement under the tongue:

Place the thermometer under the tongue, as far back as possible to the left or right. Measurement takes approx. 10 to 15 seconds.

A temperature taken under the tongue is approx. 0.5° C lower than when taken rectally.

ALECTO BC07 - Measurement under the tongue: - 1

Measurement under the arm

Make sure the armpit is dry and place the thermometer under the arm. The sensor must touch the skin.

Keep your arm crossed in front of your chest. The measurement takes approx. 20 seconds.

A temperature taken under the tongue is approx. 1.0°C lower than when taken rectally.

Rectal measurement

Insert the thermometer sensor gently (maximum 1.25 cm). Measurement takes approx. 6 to 10 seconds.

REPLACING THE BATTERY

The battery must be changed when the symbol appears in the display. Battery type: 1.55V, LR41 alkaline or SR41 silver oxide type or similar.

  1. Carefully remove the battery cover from the thermometer.

ALECTO BC07 - REPLACING THE BATTERY - 1

  1. Remove the battery protector.
  2. Use a pointed (non-metal) object to remove the battery. Insert the new battery with the + side upward.
  3. Replace the battery protector.
  4. Slide the battery cover back in place.

Do not throw away empty or leftover batteries, but instead hand them in to your local depot for Household Chemical Waste.

ALECTO BC07 - REPLACING THE BATTERY - 2

ADVICE AND WARNINGS

  • Keep the thermometer and battery out of the reach of children.
  • Do not talk or walk around while taking your temperature.
  • Store the thermometer in the special case.
  • Do not expose the thermometer to direct sunlight, dust or moisture.
  • Do not dismantle the thermometer.

STORAGE AND CLEANING

Clean the thermometer before and after use, using a soft cloth and alcohol, or cold soapy water. The thermometer may be briefly immersed in water or alcohol (do not soak or sterilise). Store the thermometer in the special case.

CE

This device complies with the EC directive 93/42/EEC (Medical Devices). The declaration of conformity is available on the website WWW.ALECTO.NL

ALECTO BC07 - CE - 1

ALECTO BC07 - CE - 2

1: Temperatursensor
2:Display
3: On (Ein)-/Start-/Stop-/Speicher-/Off (Aus)-Taste

37.8°

Temperaturanzeige

37.8°