USER MANUAL LD 72 Davita
Link: http://www.davita.de/download-center.html

Achtung Spannung
We are pleased to welcome you as a new customer to our product. You have made the right decision. You have purchased a product which will improve your quality of life for many years.
Medical explanation of the effect of light therapy
Today we know that sun light acts like a natural clock for many of our physiological processes. Bright light travels in the form of electric impulses via the eyes and the optical nerves to the nervous system's inner timer in our brain. This "time giver" processes the information about light and darkness and instructs other parts of the brain to rhythmically distribute chemical messengers. Bright light thus stimulates the production of chemical messengers which influences the mood and suppresses the production of the body's sleep inducing hormone.
How to use the DAVITlight therapy units
The light therapy boxes can be used for the following symptoms:
winter depression
non-seasonal affective disorder
premenstrual syndrome ("PMS", "days before the days")
sleep disorders
Some basic information before using the light therapy units
Before use, kindly check that the instrument is in functional order and that there is no sign of damage. Phototherapy instruments must only be operated in dry and closed rooms that are free of any explosion risks. The device is not suitable for use in the presence of flammable anesthetic mixtures with air or with oxygen or nitrous oxide. The instruments must be standing free and should not be exposed to sun.
How to carry out light therapy
Place the instrument on an even surface and connect the plug with a wall socket. Sit down in front of the instrument and keep a distance of approx. 55cm in case of the LD 72 / LD 72-2, a distance of approx. 45cm in case of the LD 110 and a distance of approx. 50cm in case of the PhysioLight LD 220. The treatment time with the LD 72 is at the above mentioned distance approx. 2 hours, approx. 1 hour in case of the LD 110 and approx. 30 minutes in case of LD 220. If you use the LD 72, LD 72-2 or LD 110 move the tilting switch to "On" and the device begins to glow. If you use the LD 220 you have to turn the control knob of the timer clockwise. Then the light therapy unit begins to glow. After the preset application time has expired, the LD 220 switches off automatically. The LD 72, LD 72-2 and LD 110 must be switched off manually.
Keep your eyes open during the treatment. You are in the position to read, watch TV or carry out any other activities.
After every 1 - 2 minutes you should look for a few seconds into the light source. A constant staring into the light source must be avoided. If you want to cover the phototherapy instrument after use allow the instrument to cool down at least 15 minutes.
Important: In order to be protected against UV-rays, the light box must only be operated with its original protective filter in place.
Fastening of light therapy units LD 72, LD 72-2 and LD 110 on the wall
The light therapy units LD 72, LD 72-2 and LD 110 can be mounted on the wall.
On the back side of the top of these light therapy units there is an opening in the middle below the air vents (see illustration).

At this opening the units can be fixed on the wall with a screw. Depending on the type of wall, an appropriate screw must be used, may be with pegs. E.g. a round head wood screw which is screwed into an expansion anchor. The screw and the anchor are not included in the scope of delivery.
The screw head must not exceed a max. height of 6mm and a max. diameter of 8mm . The distance from the wall to the screw head can be max. 8mm . The screw shaft may have a maximum diameter of 4mm .
The load on the screw and the condition of the wall, to which the unit has
to be mounted must have a capacity of at least 3kg . The base of the light therapy units LD 72, LD 72-2 and LD 110 must
be unscrewed before the fastening. Therefore the right and the left thumb screw must be completely removed from the foot. So the foot can be removed completely from the upper part of the unit. Afterwards the screws have to be screwed in for safekeeping.
Operation of the light therapy units with the DAVITONwith floor stand
The activated DAVITON (not included in the scope of delivery) reminds you with an acoustic signal every 90 seconds to look for 3 seconds direct into the light source. The light therapy unit PhysioLight LD 220 can be used together with a floor stand (not included in the scope of delivery).
Frequency and time of treatment
If the treatment takes place at your practitioner it should initially be carried out 5 times per week for a period of 2 - 3 weeks; thereafter, 3 times per week for a period of 2 - 3 weeks. After that, the treatment should take place as needed or when the symptoms occur again. At home, the treatment can take place daily, especially during autumn and winter time. The best treatment time for winter depression and the non seasonal depression is the early morning or the time of the lowest mood. The premenstrual syndrome ("PMS") is treated most effectively in the evening. As for abnormal shifts in a person's day-and-night rhythm (circadian rhythm), i.e. going to bed very early and very early awakening) there are two ways of treating them: if you go to bed very early and get up very early, treatment is most effective in the evening. If you go to bed very late and wake up very late, a treatment is best in the morning.
Side effects and contraindications
By using phototherapy the following side effects have been observed: Headaches, nausea, irritability and burning of the eyes can occur rarely for a short period. An absolute contraindication that means circumstances that do not allow the use of light therapy units is not known so far.
Please take care in case of all types of eye diseases and the eye specialist should be consulted before. In case of patients being under treatment with lithium or medicine for example Fluoxetine, Imipramine et al., which increase the sensibility of the eyes on light a supervision of the light therapy by an eye specialist could be considered.
Safety Check
Only skilled and qualified companies are entrusted to perform safety checks. Suitable test devices and facilities are mandatory. The medical device should only be used with accessories listed in the user manual. In accordance with MPBetreibV, the light therapy boxes for use in the commercial sector has to undergo mandatory safety checks every 2 years or in shorter intervals and after each repair or refurbishment. The operator is responsible to repair (commission repair) of any defects detected during the safety check.
Cleaning, maintenance and recycling
The instruments do not need any special maintenance and requires no calibration. The manufacturer does not require such preventive inspections by other persons. Qualified companies / individuals can make repairs to the light therapy devices. The necessary technical documents and other information can be requested by DAVIDAe mains have to be disconnected, before opening the devices. To clean the outer casing parts of the devices, we recommend a mild cleaning agent (as used for glass).

Packaging: DAVITA takes part in the system „Grüner Punkt“ (“Green Point”). All packaging parts are made out of recyclable materials and must be recycled in accordance of the guideless concerning each material (eco-friendly). In case of the light therapy boxes LD 72, LD 72-2 and LD 110 the casing and the front of the cover are made of plastic material. The PhysioLight LD 220 has a casing out of stainless steel.
Fluorescent lamps as well as instruments marked with the symbol of a crossed out dustbin may not be disposed via the regular garbage. The electrical and electronic components must be recycled separately. Please get in touch with your local authority to find the right way to of disposal. If electrical appliance is disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. For the return and disposal of batteries the battery law is valid. National wide there are re-sampling points. The batteries must be thrown into the green collection boxes.
Guarantee
DAVITA® guarantees for this device a period of 24 month after date of sale. The guarantee is valid for material defects and manufacturing faults and includes the provision of spare parts as well as labour. Guarantee expires if the instruments have been damaged or used improperly or unauthorized intervention was carried out. Please keep the purchase receipt as proof and submit it together with your claim for guarantee. DAVITA® will only fulfil the guarantee upon receipt of your purchase proof. Lamps are generally excluded from the guarantee.
Technical data
| Instrument Type: | Light therapy box LD 72, LD 72-2 | Light therapy box LD 110 | Light therapy box PhysioLight LD 220 |
| Article number: | 11072 11110 10220 | ||
| Medical product regarding 93/42/EWG: | Yes Yes Yes | ||
| Housing: | High quality plastic housing | High quality stainless steel | |
| Housing measures: | H: 52, W: 30, D: 7 cm H: 52, W: 30, D: 7 cm H: 60, W: 40, D: 8 cm | ||
| Weight: | 3,0 kg 3,0 kg 7,5 kg | ||
| Lamps: | 2 x 36 watt 3 x 36 watt 4 x 55 watt | ||
| Lighting power, distance and therapy length: | 10.000 Lux at 20 cm distance for 30 minutes | 10.000 Lux at 30 cm distance for 30 minutes | 10.000 Lux at 50 cm distance for 30 minutes |
| Important: Please notice that the light therapy can only successfully used in a distance of at least 45 - 55 cm! | 5.000 Lux at 35 cm distance for 60 minutes | 5.000 Lux at 45 cm distance for 60 minutes | 5.000 Lux at 75 cm distance for 60 minutes |
| 2.500 Lux at 55 cm distance for 2 hours | 2.500 Lux at 70 cm distance for 2 hours | 2.500 Lux at 110 cm distance for 2 hours | |
| Average lifetime of the lamps via the specification of the producer: | approx. 10.000 hours approx. 10.000 hours approx. | 10.000 hours | |
| Energy costs: (at an average price of 0,17 € / kWh): | < 0,02 € per hour < 0,02 € per hour < 0,04 € per hour | ||
| Fuse: | 1 Fuse, 250 V ~ 3A, Φ 5 x 20 You can finde the fuse behind the front housing. | 2 Fuses 250 V ~ 2A, Φ 5 x 20 | |
| Electric ballast units: | Instant starting, flickerfree light, no stroboscopic effects. Buzz free operation. Automatic switch off at the end of lamp live time. | ||
| Light emission: | The selection of lighting source and light filter reduces the energy of light emitted in the Infrared and UV range to a minimum level, so it is harmless to human skin and eyes. | ||
| Storage: | - 10 degrees C up to 50 degrees C and a relativ humidity of max. 90% | ||
| Operation in the altitude of max.: | 2.000 meter | ||
| Operation temperature and humidity:: | 10°C to 25°C; 10% to 95% relative humidity | ||
| Mains requirements: | 230 - 240 V~ , 50 - 60 Hz | ||
| Product Classification | 1. Class II equipment, Class I equipment for LD 220 2. No applied part 3. Protection against ingress of water: IP 20 4. Not category AP / APG equipment 5. Mode of operation: Continuous operation | ||
Signs and symbols
The following symbols appear in this manual, on the device or on its accessories:

C0482
Caution: Consult accompanying documents
CE Mark: conforms to essential requirements of the Medical Device Directive 93/42/EEC.

Class I equipment

Class II equipment

Manufacturer

Serial number

DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
EMC-Declaration
Link: http://www.davita.de/download-center.html

Warning: dangerous voltage
Technical changes can be applied at any time without prior notice.. Rev. No: 11071111