HWW 900 GC - Water pump Güde - Free user manual and instructions
Find the device manual for free HWW 900 GC Güde in PDF.
User questions about HWW 900 GC Güde
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Water pump in PDF format for free! Find your manual HWW 900 GC - Güde and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HWW 900 GC by Güde.
USER MANUAL HWW 900 GC Güde
GB Translation of the original instructions
natural_image
Blue industrial air compressor unit with visible internal components and mounting base (no text or symbols)HWW 900 GC
94686

LIEFERUMFANG | DELIVERED ITEMS | ARTICLES DÉLIVRÉS | VOLUME DELLA FORNITURA | LEVERINGSOMVANG | OBJEM DODÁVKY | ROZSAH DODÁVKY | SZÁLLÍTÁSI TERJEDELEM | OBSEG DOBAVE | OPSEG ISPORUKE | ОБЕМ НА ДОСТАВКАТА | VOLUMUL LIVRĂRII | OPSEG ISPORUKE


natural_image
Blue industrial air compressor unit with visible cooling fan and control panel (no text or symbols)HWW 900 GC

ENGLISH Please read the instructions carefully before starting the machine.
Service international
75

text_image
6 2 1 9 3 4 5 7 81 | Druckanschluss | Pressure connection | Raccord à pression | Raccordo a pressi one | Aansluiting drukleiding | Tlaková prípojka | Tlaková prípojka | Nyomás csatlakozó | Tlačni priključek | Tlačni priključak | Напорно присъединение | Cuplă de presiune | Tlačni priključak
2 | Entlüftungsschraubes | Bleeder screw | Vis de purge | Vite di deaerazione | Ontluchtingsschroef | Odvzdušnovaci šroub | Odvzdušnovacia skrutka | Légtelenító csavar | Vijak za odzračevanje | Vijak za odzračivanje | Obезвъздушаващ болт | Šurub de aerare | Vijak za ispuštanje zraka
3 | Saugleitungsanschluss | Suction pipe connection | Raccord de tuyau d'aspiration | Attacco dei tubi d'aspirazione | Aansluiting zuigleiding | Prípojka sacího potrubí | Prípojka nasávacieho potrubia | Szívó vezeték cxatlakozó | Priključek za sesalno cev | Priključak cjevovoda za usisivanje | Присъединение на всмукателния тръбопровод | Conectarea conductei de aspiratie | Priključak usisne cijevi
4 | Netzleitung | Feeder cable | Câble d'alimentation | Cavo d'alimentazione | Netsnoer | Napájecí kabel | Napájací kabel | Tápláló kabel | Električni kabel | Priključni kabel | Захранващ кабел | Cablu de alimentare | Električni kabel
5 | Motor | Engine | Moteur | Motore | Motor | Motor | Motor | Motor | Motor | Motor | Motor | Motor | Motor
6 | Anschlusskasten | Terminal box | Boîte de raccordement | Scatola di connessione | Aansluitkast | Připojova cí skřínka | Pripájacia skrinka | Csatlakozó szekrény | Priključna omarica | Priključni ormar | Присъединителна кутия | Tablou de conexiune | Priključni ormar
7 | Kessel | Air jet | Réservoir d'air | Polmone | Ketel | Vzdušnik | Vzdušnik | Légtartály | Tlačna posoda | Spremnik zraka | Отдушник | Jiclor de aer | Rezervoar za vazduh
8 | Druckschalter | Pressure switch | Interrupteur a pression | Contatore a pressione | Drukschakelaar | Tlakový spínač | Tlakový spínač | Nyomás kapcsoló | Tlačno stikalo | Tlačni prekidač | НАПОРЕН ВКЛЮЧВАТЕЛ | Presostat | Tlačni prekidač
9 | Manometer | Manometer | Manomètre | Manometro | Manometer | Manometr | Manometer | Manometer | Manométer | Manometer | Manometar | Manometér | Manometru | Manometar
DE INBETRIEBNAHME HU ÜZEMBE HELYEZÉS
GB STARTING-UP THE MACHINE SI UVEDBA V POGON
FR MISE EN SERVICE HR PUŠTANJE U RAD
natural_image
Blue industrial air compressor unit with control panel and side-mounted fan (no visible text or symbols)2
natural_image
Close-up of a blue industrial machine with attached metal connectors (no visible text or symbols)3
natural_image
Blue industrial air compressor with cooling fans and a thermometer showing temperature (no text or symbols on the device itself)4
DE BETRIEB HU ÜZEMELTETÉS
GB OPERATION SI DELOVANJE
FR FONCTIONNEMENT HR RAD
IT ESERCIZIO BG PABOTA
NL GEBRUIK RO FUNCTIONARE
CZ PROVOZ BA RAD
SK PREVÁDZKA

natural_image
Blue industrial air compressor unit with control panel and fan (no visible text or symbols)5
DE DRUCKSCHALTER HU NYOMÁS KAPCSOLÓ
GB PRESSURE SWITCH SI TLAČNO STIKALO
FR INTERRUPTEUR A PRESSION HR TLAČNI PREKIDAČ
IT CONTATORE A PRESSIONE BG НАПОРЕН ВКЛЮЧВАТЕЛ
NL DRUKSCHAKELAAR RO PRESOSTAT
CZ TLAKOVÝ SPÍNAČ BA TLAČNI PREKIDAČ
SK TLAKOVÝ SPÍNAČ

natural_image
Close-up of a black industrial engine component with a pair of wrenches above it (no text or symbols visible)7
DE TRANSPORT / AUFBEWAHRUNG HU SZÁLLÍTÁS / TÁROLÁS
GB TRANSPORT / STORAGE SI TRANSPORT / SHRANJEVANJE
FR TRANSPORT / STOCKAGE HR PRIJEVOZ / USKLADIŠTENJE
IT TRASPORTO / STOCCAGGIO BG TPAHСПОРТИРАНЕ / СЪХРАНЕНИЕ
NL TRANSPORT / BEWARING RO TRANSPORT / DEPOZITARE
CZ PŘEPRAVA / ULOŽENÍ BA PREVOZ / USKLADIŠTENJE
SK TRANSPORT / ULOŽENIE

natural_image
Blue industrial air compressor inside a transparent enclosure (no text or symbols visible)8
DE WARTUNG HU KARBANTARTÁS
GB MAINTENANCE SI VZDRŽEVANJE
FR ENTRETIEN HR ODRŽAVANJE
IT MANUTENZIONE BG ПОДДРЪЖКА
NL ONDERHOUD RO ÎNTRETINERE
CZ ÚDRŽBA BA ODRŽAVANJE
SK ÚDRZBA

natural_image
Blue industrial air compressor with a wrench above it, no visible text or symbols9
![]() | DE INBETRIEBNAHME HU ÜZEMBE HELYEZÉS | |
| GB STARTING-UP THE MACHINE SI UVEDBA V POGON | ||
| FR MISE EN SERVICE HR PUŠTANJE U RAD | ||
| IT MESSA IN FUNZIONE BG ПУСКАНЕ В ДЕЙСТВИЕ | ||
| NL INBEDRIJFSTELLING RO PUNEREA İN FUNCTIUNE | ||
| CZ UVEDENÍ DO PROVOZU BA PUŠTANJE U RAD | ||
| SK UVEDENIE DO PREVÁDZKY | ||

HWW 900 GC

text_image
> 0° | < 40°
text_image
√ min. 400 mm
text_image
Safety warning diagram showing a blue industrial pump with crossbar and warning symbols| DE | ANSCHLUSS | HU | FESZÜLTSÉG |
| GB | SERVICE CONNECTION | SI | PRIKLJUČEK |
| FR | ALIMENTATION | HR | PRIKLJUČAK |
| IT | ALLACCIAMENTO | BG | ПРИСЬЕДИНЕНИЕ |
| NL | AANSLUITING | RO | RACORD |
| CZ | PŘÍPOJKA | BA | PRIKLJUČAK |
| SK | PRÍPOJKA |


HWW 900 GC

text_image
A B
text_image
A TIP KA 4 P / 94440 KA 7 P / 94441
text_image
1 A + B TYPE THREAD SEAL PTFE
text_image
2 A
natural_image
Blue industrial air purifier with green pump and black hose, no visible text or symbols
natural_image
Blue industrial air compressor with hoses and valve, no visible text or symbols
natural_image
Blue industrial air compressor with heat exchanger and thermometer indicator (no text or symbols on device)natural_image
Blue industrial air compressor with attached fan and control unit (no visible text or symbols)
HWW 900 GC

text_image
Diagram illustrating a water treatment or filtration system with labeled components and directional arrows, including warning symbols and fluid flow paths.
natural_image
Blue industrial air compressor with control panel and fan (no visible text or symbols)DE BETRIEB HU ÜZEMELTETÉS
GB OPERATION SI DELOVANJE
FR FONCTIONNEMENT HR RAD
IT ESERCIZIO BG PABOTA
NL GEBRUIK RO FUNCTIONARE
CZ PROVOZ BA
RAD
SK PREVÁDZKA

HWW 900 GC

natural_image
Illustration of a blue pressure vessel connected to a water tank via tubing, with a water drop falling from the pipe (no text or symbols present)
text_image
1 I
natural_image
Illustration of a faucet with water droplets falling into the water, no text or symbols present
text_image
3 AUTO-START bar 1,5 bar
natural_image
Simple black-and-white diagram of a faucet with a circular arrow symbol above it, no text or labels present.
text_image
5 AUTO-STOP 3,0 bar
text_image
6 0
natural_image
Close-up of a black mechanical component with two black wrenches above it (no text or symbols visible)DE DRUCKSCHALTER
GB PRESSURE SWITCH
FR INTERRUPTEUR A PRESSION
IT CONTATORE A PRESSIONE
NL DRUKREGELAAR
CZ TLAKOVÝ SPÍNAČ
SK TLAKOVÝ SPÍNAČ
HU NYOMÁS KAPCSOLÓ
SI TLAČNO STIKALO
HR TLAČNI PREKIDAČ
BG НАЛЯГАНЕТО Е НАСТРОЕНО ДИТЕЛЯ
RO PRESOSTAT
BA TLAČNI PREKIDAČ


HWW 900 GC
1

natural_image
Close-up of a blue industrial machine with a screwdriver and rotating arm (no visible text or symbols)2

natural_image
Close-up of a blue industrial air vent with internal components and red directional arrows indicating flow or movement (no text or symbols visible)3

natural_image
Close-up of a blue industrial machine with a black tool and circular component, no visible text or symbolsGB Pressure is set properly by zhe manufacturer. If different pressure is expected, it needs to be adjusted as shown in pictures 1-3.
natural_image
Interior view of a blue industrial air conditioner unit inside a transparent enclosure (no text or symbols visible)| DE | TRANSPORT / AUFBEWAHRUNG | HU | SZÁLLÍTÁS / TÁROLÁS |
| GB | TRANSPORT / STORAGE | SI | TRANSPORT / SHRANJEVANJE |
| FR | TRANSPORT / STOCKAGE | HR | PRIJEVOZ / USKLADIŠTENJE |
| IT | TRASPORTO / STOCCAGGIO | BG | TPAHCПОРТИРАНЕ / СЪХРАНЕНИЕ |
| NL | TRANSPORT / BEWARING | RO | TRANSPORT / DEPOZITARE |
| CZ | PŘEPRAVA / ULOŽENÍ | BA | PREVOZ / USKLADIŠTENJE |
| SK | TRANSPORT / ULOŽENIE |


HWW 900 GC

natural_image
Industrial air conditioning unit with blue cylinder, pump, and water tap (no text or symbols)
text_image
2 STOP 0
text_image
3 0
text_image
4 No SnowDE WARTUNG HU KARBANTARTÁS
GB MAINTENANCE SI VZDRŽEVANJE
FR ENTRETIEN HR ODRŽAVANJE
IT MANUTENZIONE BG ПОДДРЪЖКА
NL ONDERHOUD RO ÎNTRETINERE
CZ ÚDRŽBA BA ODRŽAVANJE
SK ÚDRZBA

natural_image
Blue industrial air compressor with a wrench above it, no visible text or symbols
HWW 900 GC

natural_image
Blue industrial air compressor with labeled component 'O' and inset view showing a control panel (no text or symbols on the device itself)
natural_image
Illustration of a blue air compressor system with pipe connections and a water tank (no text or symbols)
natural_image
Blue industrial machine with mechanical components and a close-up inset showing a hand holding a circular component (no text or symbols visible)
natural_image
Blue industrial tank connected to a spring scale with a hanging weight (no text or symbols visible)
text_image
5 1,5 - 1,8 bar
natural_image
Blue industrial machine component with directional arrows indicating rotation or flow (no text or symbols)Technische Daten
HWW
IPX4 Schutzgrad IPX4
Gewicht 19,5
Max. delivered quantity....3600 l/h

Max. head of delivery 42 m

Max. suction head....8 m
35°C
Max. Water temperature....35°C

Hose connection....1" IG
IP X4
Degree of protection IPX4

Weight....19,5

Sound power level....86 dB

tank capacity....24 l


Read and understand the operating instructions before using the appliance. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties.
In case of any doubts about connection and operation refer please to our customer center
Specifi ed Conditions Of Use
The pump is designed for pumping clean water only to supply the home with water and to use it at home, in garden, courtyard and for fi elds. Respecting technical data and safety precautions.
Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.
The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is curtailed correspondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
⚠️ Do not use the pump for drinking water!
The pump must not be connected to the existing water-supply network as a pressure-boosting device.
⚠️ Never use the pump as a pool circulation pump.
Safety Instructions
WARNING!
Electric shock! There is a risk of an injury caused by electric shock!
This device is not intended for use by persons (including children) with limited physical, sensory or mental capabilities or without the necessary lack experience or knowledge unless they are supervised by a person who is responsible for their safety or were instructed by that person in how to use the device.
Children should be supervised to ensure that they do not play with the device. Always keep children and unauthorised persons out of reach of the appliance.
Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA).
Before putting into operation, a qualified electrician must check whether electric safety measures required are in place. Any national regulations in this regard must be complied with.
Electric connection to a socket.
Do not expose the appliance to rain and do not use it in wet or moisture conditions.
It is necessary to make sure the connecting socket was not near water and humidity and the plug was protected against humidity.
Avoid installing the appliance in wet shafts (risk of short circuit, corrosion effects)!
Check the voltage. Technical data given on the type label must correspond with electric network voltage.
Only use splash proof extension cables approved for outdoor purposes.
Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid!
Check the cable and/or socket for damages before the appliance putting into operation.
To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself.
Protect the feeder cable from excessive temperatures, oil and sharp edges.
⚠️ If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.).
⚠ The pump must not in any case run without fillings.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
The temperature of the drained liquid must not exceed +35 °C.
When using the pump for domestic water supply, always observe the local regulations of water management authorities and the waste water drainage.
If the pump is used in ponds, wells, etc. and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed.
Do not use pump at outside temperatures over 40 °C or under 0 °C
In cold weather, the pumping body motor should not bewrapped in a blanket or another piece of textile with intent to prevent the water freezing.
The user is responsible to third parties if pump (dumping stations, etc.) is used.
Requirements for operating staff
The operating staff must carefully read the Operating Instructions before using the appliance.
Qualifi cation: Apart from the detailed instructions by a professional, no special qualifi cation is necessary for appliance using.
Minimum age: Persons over 16 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education.
Training: Using the appliance only requires corresponding training by a professional or the Operating Instructions. No special training is necessary.
Emergency procedure
Conduct a fi rst-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. For the sake of eventual accident, in accordance with DIN 13164, a workplace has to be fitted with a fi rst-aid kit. It is essential to replace any used material in the fi rst-aid kit immediately after it has been used. If you seek help, state the following pieces of information:
- Accident site
- Accident type
- Number of injured persons
- Injury type(s)
Maintenance
⚠️ Before carrying out any work on the machine, disconnect the plug from the socket.
Prior to every use, visually check the machine to rule out any defects, in particular on the power cable and the plug.
The machine must not be used under any circumstances if the machine or the safety devices are damaged.
Refer all servicing to customer service. Use only original accessories and original spare parts.
Caution: Standing water may corrode (brownish colour) in the pump according to design.
At winter storing, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance. Prior to transportation, it is necessary to unplug the pump from the grid! The device has to be completely emptied and stored with frost-proof protection. Adhesion of mechanical seals can be prevented if you rinse the pump with appropriate oil (for example, with vegetable oil).
Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.
Guarantee
Guarantee claims as per guarantee card attached.
The guarantee solely covers inadequacies caused by material defect or manufacturing defect. Original payment voucher with the sales date needs to be submitted for any claim in the guarantee period.
The guarantee does not cover any unauthorised use such as appliance overloading, use of violence, damage as a result of any unauthorised interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee..
GÜDE cannot be held responsible for damages incurred in consequence of unqualified installation or unskilled handling of the pump.
The device has to be checked on a regular basis to ensure perfect functioning.
Let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the below-mentioned cases:
- Unprofessional repairs executed by unauthorised service centres;
- Use in conflict with the designed purpose, or failure to observe the use as designed;
- Pump overload with a continuous run;
- Damage as a result of icing or any other fault caused by climatic influences; Identical regulations apply for accessory parts.
To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).
Service
Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? We will quickly help you and without needles bureaucracy at our web pages at www.guede.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label. Please enter it here for future reference:
Serial No.:
Art. No:
Year of production:
Symbols

Read the Operating Instructions

Before carrying out any work on the machine, disconnect the plug from the socket.

Cable pulling / transport prohibited

Staying in the transportation medium prohibited

Warning against dangerous electric voltage

Warning against automatic starting

Accessory - Not included in standard equipment, available as an accessory.

Any damaged or disposed electric or electronic devices must be delivered to appropriate collection centres.

Protect against humidity

This side up
EC-Declaration of Conformity
GÜDE GmbH & Co. KG
We, hereby declare the conception and construction of the below mentioned appliances correspond - at the type of construction being launched - to appropriate basic safety and hygienic requirements of EC Directives. In case of any change to the appliance not discussed with us the Declaration expires.
Domestic water supply unit
HWW 900 GC
Appropriate EU Directives
2006/95 EG, 2004/108 EG
Harmonised standards used
EN 60335-1:2002+A1+A11+A12+A2+A13+A14
EN 60335-2-41:2003+A1+A2
EN 62233: 2008
EN 55014-1:2006+A1
EN 55014-2:1997+A1+A2
EN 61000-3-2: 2006+A1+A2
EN 61000-3-3:2008


Wolpertshausen, 2011-11-24 Helmut Arnold Managing
Technical documentation Joachim Bürkle
Inspection and maintenance plan
Time interval Description Any other details
As needed Clean the check valve and the prefliter. Check the check valve function.
Failures – causes - removal
| Failures Causes Removal | ||
| Engine does not start No power supply. Blocked pump wheel | Turn the engine shaft with screwdriver through the fan cover (to release friction circles sealing that may be stuck together). | |
| Pump does not suck Missing, loose or blocked check valve Check valve is not in water. Pump without water Too high suction head. Air bubbles in the suction pipeline. Connections not sealed, pump sucks air, pump is not deaerated. | Fix or clean the check valve. Immerse the check valve into water. Fill the pump shell with water. Check the suction head. Check the tighten of suction pipeline. Carefully repeat connection according to the chapter „Connection“! | |
| Insufficient amount of water pumped | Too high suction head. Water level quickly drops down | Check the suction head. Clean the strainer., Position the check valve lower. Clean the pump and replace worn parts. (qualifi ed workshop) |
| Reduced switching intervals | Air pressure in the receiver too low Control air pressure. →9 | |
Kolarov Technologic O.O.D.
Jordan Bogdar 4
BG-8800 Sliven
Tel: 00359/886568083
Fax: 00359 / 44680404
Austria
Güde GmbH & Co. KG
Albrechtsberg 12
SK-03301 Liptovsky Hr dok
Tel: 0042 / 1445225151
Fax: 0042 / 1445225151
Romania
SC COM LANKA SRL BAIA MARE
Alba Iuliastr. 52 Maramures
RO-430325 Baia Mare
Tel: 0040 / 362416055
Fax: 0040 / 744982645
GÜDE GmbH & Co. KG
Birkichstrasse 6
74549 Wolpertshausen
Deutschland