USER MANUAL DHT 120 TEKA

Congratulations on your choice. We are certain that this modern, functional and practical device made with first rate quality materials will fully satisfy your requirements. Please read all the sections in this INSTRUCTION MANUAL before using the hood for the first time in order to obtain maximum performance from the device and avoid faults which may arise from incorrect use as well as minor problem solving.

For optimal performance, the external duct should not exceed FOUR METRES, have more than two 90° angles and its diameter should be at least ∅120

Safety Instructions

  • Disconnect the device before performing any work on the interior, e.g. during cleaning or maintenance.
  • The excessive accumulation of grease in the hood and metal filters may cause dripping and fire risks, therefore it is necessary to wash the inside of the hood and the metal filters at least once a month.
  • This device can be used by children aged 8 and over and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or proper training in the safe use of the device and if they understand the dangers involved. Children should not play with the device. Cleaning and maintenance should be performed by the user and not by unsupervised children.
  • Check that the power voltage and frequency match those indicated on the label located on the inside of the hood. A suitable earth must be connected (except for Class II

devices, marked with □ on the technical data plate).

- For installation, a connection method isolated from the fixed installation should be incorporated, in accordance with installation regulations (adjusted to the strength to be endured and with a minimum opening between the contacts of 3mm) under overvoltage category III conditions, for the emergency shutdown, cleaning or light replacement. In no event should the earth pass through this switch. This switch can be replaced with a plug if it is accessible in normal use.

- If the power lead is damaged it must be replaced by the manufacturer, its after-sales service or by qualified personnel in order to avoid potential danger.

• Air should not be extracted by ducts used to expel fumes from equipment powered by gas or other fuels.

- The room must be adequately ventilated when the hood will be used simultaneously with equipment powered by energy other than electricity e.g. gas cookers.

- The excessive accumulation of grease in the hood and metal filters may cause dripping and fire risks, therefore it is necessary to wash the inside of the hood and the metal filters at least once a month.

- Do not produce flames under the hood.

- The bottom of the hood must be fitted at least 65cm above gas

or combination hobs. Observe the minimum limits set by WORKTOP MANUFACTURER'S MINIMUM LIMITS. This distance may be reduced if mentioned in the hood installation instructions.

  • Never leave gas burning without a pan above it. The grease accumulated in the filters may drip or catch fire when the temperature is increased.
  • Avoid cooking under the hood if the metal filters are not fitted e.g. while they are being cleaned in the dishwasher.
  • We recommend you wear gloves and use extra caution when cleaning the inside of the hood.
  • Your hood is designed for domestic use and only for the extraction and purification of gases from food preparation. Use for other purposes is at your own risk and may be dangerous. The manufacturer is not responsible for damage caused by improper use of the device.
  • For repairs please contact the manufacturer's nearest Technical Assistance Department which will always use genuine parts. Repairs or modifications by unauthorized personnel may result in damage to equipment or malfunction, endangering safety.
  • This device complies with the European Directive 2002/96/EC on electrical and electronic devices entitled “Electrical and Electronic Equipment Waste”. The directive provides the framework applicable throughout the European Union for the return and recycling of electrical and electronic equipment waste [symbol] responsible for his/her safety. Keep children away from the device and never let them play with it.

Instructions for use

You can activate or deactivate the cooker hood by operating the functions shown in the diagram.

Switch on the extractor fan a few minutes before you start to cook in order to ensure that a steady air flow has been established before fumes appear.

Allow the extractor fan to run for several minutes after you have finished cooking (between 3 to 5 minutes) in order to expel all the grease from the outlet duct. This prevents the return of grease, smoke and smells.

TEKA DHT 120 - Instructions for use - 1

text_image ON/OFF Receiver Emitter ON/OFF Light Decrease selected funtion - + Increase selected funtion Filter saturation indicator Timer LED

Program the working time

  • Turn the hood on and select the required extraction speed
  • Select the programming time by pressing Timer.
  • Each press of the button increases the programming time by 10 minutes, up to a maximum of 80 minutes.
  • To reset the programme, wait for over a second and press the Timer button again.
  • The speed and extraction time are displayed with the LED indicator.
  • The intensive speeds 6, 7 and 8 cannot be programmed. These must be selected manually and have a maximum duration of approximately 10 minutes.

Filter saturation indicator "F"

  • Clean the filters when all lights of the LED indicator begin to flash followed by an acoustic signal.
  • Press “Filter Saturation” to reset this feature

Cleaning and maintenance

During cleaning and maintenance work, make sure the safety instructions are complied with.

Cleaning the hood body

  • If your kitchen hood is made of stainless steel, use proprietary cleaners mentioned in the product instructions.
  • If your kitchen hood is painted, use lukewarm water and a neutral soap.
  • Never use metallic scourers, nor abrasive or corrosive products.
  • Dry the kitchen hood using a cloth that does not produce fibres.
  • Do not use vapour cleaners

Cleaning the metal filters

  • To remove the filters from their fittings, press lightly on the locks and then pull them off.
  • The metal filters can be cleaned by soaking them in hot water with neutral detergent until the fat dissolves and then rinsing them under the tap or using special anti-grease products. They can also be washed in a dishwasher. In this case, it is advisable to stack them vertically to avoid food residues to stick to them.
  • Cleaning in a dishwasher may damage the metallic surface (blackening it), although this will not affect its fat retention capacity.
  • Once clean, leave them to dry off and then fit them onto the kitchen hood.

Changing light bulbs

Proceed as follows:

  • Unscrew the lamp cover.
  • Change the broken / burnt out lamp.
  • Screw the lamp cover back in.

Problem solving

Proceed with the following checks before calling the Technical Service:

ProblemPossible causeSolution
The kitchen hood does not work.The mains cable is not connected to the network.There is no current in the network.Connect the mains cable to the network.Provide current to the network.
The kitchen hood does not extract sufficiently or vibrates.Filters are saturated with fat.Obstruction in the air outlet.Change or clean the active charcoal and/or metal filters.Remove the obstruction.
The lamps do not light up.The lamps are blownThe lamps are slack.Change the lamps.Tighten the lamps.

Active charcoal filters (Optional)

When exterior gas extraction is not possible, then the kitchen hood may be set to purify the air by recycling it through active charcoal filters.

The active charcoal filters have an active life of between three to six months, depending on the individual conditions of use. These filters cannot be washed nor regenerated. They must be replaced once their useful life comes to an end.

The manufacturer reserves the right to make changes and corrections to its products as it deems necessary, without altering their basic characteristics.

text_image 1 M4x12 A2 (8x) 2 1

TEKA DHT 120 - Active charcoal filters (Optional) - 1

text_image 1 M4x12 (8x) 2 1 M4x12 (2x)

1
TEKA DHT 120 - Active charcoal filters (Optional) - 2

text_image 1180 580 140

2

TEKA DHT 120 - Active charcoal filters (Optional) - 3

text_image 2.1 2.2

TEKA DHT 120 - Active charcoal filters (Optional) - 4

text_image 3 3.2 3.3 3.1 M4x12 A2 (3x) 3.1 M4x12 A2 (3x)

TEKA DHT 120 - Active charcoal filters (Optional) - 5

text_image 4 2° 1° 4.1 4.2 4.2 4.1 2° 1° M6x16 (6x) 4.1 10mm 4.1

TEKA DHT 120 - Active charcoal filters (Optional) - 6

text_image 5

TEKA DHT 120 - Active charcoal filters (Optional) - 7

text_image 6 2° ↑1° 6.2 6.1 6.1 6.2 2° ↑1° 6.1 M6x16 (6x) 10mm

TEKA DHT 120 - Active charcoal filters (Optional) - 8

text_image 7 Ø150 Ø120 Ø150 Ø120 B1x

8
TEKA DHT 120 - Active charcoal filters (Optional) - 9

text_image 8.2 8.1 M4x12 A2 (9x)

TEKA DHT 120 - Active charcoal filters (Optional) - 10

text_image 9 M4x12 A2 (3x) 9.1 9.2 9.4 9.3 M4x12 A2 (3x)

TEKA DHT 120 - Active charcoal filters (Optional) - 11

text_image 10 10.3 10.1 M4x12 A2 (9x) 10.2

11
TEKA DHT 120 - Active charcoal filters (Optional) - 12

natural_image Isometric line drawing of a rectangular frame mounted on a wall, with a small rectangular object placed below (no text or symbols)

Teka Subsidiaries

Country SubsidiaryAddressCityPhone
AustriaKüppersbusch AustriaEitnergasse, 131231 Wien+43 18 668 022
BelgiumKüppersbusch Belgium S.P.R.L.Doomveld Industrie, Asse 3, No. 11 - Boite 71731 Zellik+32 24 668 740
BulgariaTeka Bulgaria EOODBlvd. “Tsarigradsko Shosse” 1351784 Sofia+359 29 768 330
ChileTeka Chile S.A.Avd El Retiro Parque los Maitenes, 1237. Parque EneaPudahuel, Santiago de Chile+ 56 24 386 000
ChinaTeka International Trading (Shanghai) Co. Ltd.6/F. Datong Business Center, No. 369 Fuxing Middle Rd.200025 Shanghai+86 2 153 076 901
Czech RepublicTeka CZ S.R.O.V Holesovickách, 593182 00 Praha 8 - Liben+420 284 691 940
EcuadorTeka Ecuador S.A.Parque Ind. California 2, Via a Daule Km 12Guayaquil+593 42 100 311
Great BritainTeka Products Ltd.177 Milton ParkOX14 4SE Milton, Abingdon+44 1 235 861 916
GreeceTeka Hellas A.E.Thesi Roupaki - Aspropyrgos193 00 Athens+30 2 109 760 283
HungaryTeka Hungary Kft.Bajcsy Zsilinszky u, 531065 Budapest+36 13 542 110
IndonesiaPT Teka BuanaJalan Menteng Raya, Kantor Taman A9 Unit A312950 Jakarta+62 215 762 272
MalaysiaTeka Küchentechnik (Malaysia) Sdn Bhd10 Jalan Kartunis U1/47, Temasya Park, Off Glenmarie40150 Shah Alam, Selangor Darul Ehsan+60 376 201 600
MexicoTeka Mexicana S.A. de C.V.Ferrocarril 200, Esquina Norte 29, Col. Moctezuma15500 Mexico D.F.+52 5 551 330 493
MoroccoTeka Maroc S.A.73, Bd. Slimane, Depôt 33, Route de Ain SebaaCasablanca+212 22 674 462
PolandTeka Polska Sp. ZO.O.ul. 3-go Maja 8 / A205-800 Pruszków+48 227 383 270
PortugalTeka Portugal S.A.Estrada da Mota - Apdo 5333834-909 Ilhavo, Aveiro+35 1 234 329 500
RomaniaS.C. Teka Küchentechnik Romania S.R.L.Sevastopol str., no 24, 5th floor, of. 15010992 Bucharest Sector 1+40 212 334 450
Russia/PоссияTeka Rus LLC/OOO "Teka Pyc"ул.Барклая, д.6, стр.3, оф.402121087 Россия, Москва+7 4 956 450 064
SingaporeTeka Singapore PTE LtdClemenceau Avenue, 83, 01-33/34 UE Square239920 Singapore+65 67 342 415
SpainTeka Industrial, S.A.C/ Cajo,1739011 Santander+34 942 355 050
ThailandTeka (Thailand) Co. Ltd.364/8 Sri-Ayuttaya Road, Phayathai, Ratchatavee10400 Bangkok+66 -26 424 888
TurkeyTeka Teknik Mutfak Aletleri Sanayi VeBüyükdere Cad. 24/1380290 Mecidiyeköy, Istanbul+90 2 122 883 134
UkraineTeka Ukranie LLC86-e, Bozhenko Str .2nd floor,4th entrance03150 Kyiv+380 444 960 680
United Arab EmiratesTeka Middle East FzeBuilding LOB 16, Office 417P.O. Box 18251 Dubai+971 48 872 912
United Arab EmiratesTeka Küchentechnik U.A.E LLCBin Khedia CentreP.O. Box 35142 Dubai+971 42 833 047
VenezuelaTeka Andina S.A.Ctra. Petare-Santa Lucia, km 3 (El Limoncito)1070 Caracas+58 2 122 912 821
VietnamTEKA Vietnam Co., Ltd.803 Dai Minh Convention Tower, 8th Floor77 Hoang Van Thai, District 7, Ho Chi Minh+84 854 160 646
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : TEKA

Model : DHT 120

Category : Range hood