TEKTRONIX DPO4054B - Oscilloscope

DPO4054B - Oscilloscope TEKTRONIX - Free user manual and instructions

Find the device manual for free DPO4054B TEKTRONIX in PDF.

📄 20 pages English EN Download 💬 AI Question
Notice TEKTRONIX DPO4054B - page 11
View the manual : Français FR English EN
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about DPO4054B TEKTRONIX

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Oscilloscope in PDF format for free! Find your manual DPO4054B - TEKTRONIX and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DPO4054B by TEKTRONIX.

USER MANUAL DPO4054B TEKTRONIX

Vertical System Analog Channels

CharacteristicDPO4034B MSO4034BDPO4054B MSO4054BDPO4104B MSO4104B
Input Channels4
Analog Bandwidth (-3 dB) 5 mV/div - 1 V/div350 MHz500 MHz1 GHz
Calculated Rise Time 5 mV/div (typical)1 ns700 ps350 ps
Hardware Bandwidth Limits20 MHz or 250 MHz
Input CouplingAC, DC
Input Impedance1 MΩ ±1%, 50 Ω ±1%
Input Sensitivity, 1 MΩ1 mV/div to 10 V/div
Input Sensitivity, 50 Ω1 mV/div to 1 V/div
Vertical Resolution8 bits (11 bits with Hi Res)
Max Input Voltage, 1 MΩ300 VRMS CAT II with peaks ≤ ±425 V
Max Input Voltage, 50 Ω5 VRMS with peaks < ±20 V
DC Gain Accuracy±1.5%, derated at 0.10%/°C above 30 °C
Channel-to-Channel Isolation≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated bandwidth for any two channels having equal volts/div settings

Offset Range

Range1 MΩ50 Ω
1 mV/div to 50 mV/div±1 V±1 V
50.5 mV/div to 99.5 mV/div±0.5 V±0.5 V
100 mV/div to 500 mV/div±10 V±10 V
505 mV/div to 995 mV/div±5 V±5 V
1 V/div to 5 V/div±100 V±5 V
5.05 V/div to 10 V/div±50 VNA

Vertical System Digital Channels

CharacteristicAll MSO4000B Models
Input Channels16 Digital (D15 - D0)
ThresholdsPer-channel Thresholds
Threshold SelectionsTTL, CMOS, ECL, PECL, User Defined
User-defined Threshold Range±40 V
Maximum Input Voltage±42 Vpeak
Threshold Accuracy±(100 mV + 3% of threshold setting)
Input Dynamic Range30 Vp-p≤200 MHz 10 Vp-p>200 MHz
Minimum Voltage Swing400 mV
Input Impedance100 kΩ
Probe Loading3 pF
Vertical Resolution1 bit

Horizontal System Analog Channels

CharacteristicDPO4034B MSO4034BDPO4054B MSO4054BDPO4104B MSO4104B
Maximum Sample Rate (All channels)2.5 GS/s2.5 GS/s5 GS/s
Maximum Record Length (All channels)20M points
Maximum Duration at Highest Sample Rate (All channels)8 ms8 ms4 ms
Time Base Range1 ns to 1,000 s400 ps to 1,000 s
Time Base Delay Time Range-10 divisions to 5000 s
Channel-to-Channel Deskew Range±125 ns
Time Base Accuracy±5 ppm over any ≥1 ms interval

Horizontal System Digital Channels

CharacteristicAll MSO4000B Models
Maximum Sample Rate (Main)500 MS/s (2 ns resolution)
Maximum Record Length (Main)20M points
Maximum Sample Rate (MagniVu)16.5 GS/s (60.6 ps resolution)
Maximum Record Length (MagniVu)10k points centered around the trigger
Minimum Detectable Pulse Width (Typical)1 ns
Channel-to-Channel Skew (Typical)200 ps
Maximum Input Toggle Rate500 MHz
Maximum frequency sine wave that can accurately be reproduced as a logic square wave. Requires the use of a short ground extender on each channel.
This is the maximum frequency at the minimum swing amplitude. Higher toggle rates can be achieved with higher amplitudes.

Trigger System

CharacteristicDescription
Main Trigger ModesAuto, Normal, and Single
Trigger CouplingDC, AC, HF reject (attenuates >50 kHz), LF reject (attenuates <50 kHz), noise reject (reduces sensitivity)
Trigger Holdoff Range20 ns to 8 s

Trigger Sensitivity

CharacteristicDescription
Internal DC Coupled
1 MΩ Path (All models)For 1 mV/div to 4.98 mV/div; 0.75 div from DC to 50 MHz, increasing to 1.3 div at rated bandwidth
50 Ω Path (MSO/DPO4054B, MSO/DPO4034B)For ≥5 mV/div; 0.4 div from DC to 50 MHz, increasing to 1 div at rated bandwidth
50 Ω Path (MSO/DPO4104B)0.4 div from DC to 50 MHz, increasing to 1 div at rated bandwidth
External
Auxiliary Input200 mV from DC to 50 MHz, increasing to 500 mV at rated bandwidth

Trigger Level Range

CharacteristicDescription
Any Channel±8 divisions from center of screen
External (Auxiliary Input)±8 V

Trigger Modes

ModeDescription
EdgePositive or negative slope on any channel or front-panel auxiliary input. Coupling includes DC, AC, HF reject, LF reject, and noise reject
Sequence (B-trigger)Trigger Delay by Time - 4 ns to 8 s. Or Trigger Delay by Events - 1 to 4,000,000 events
Pulse WidthTrigger on width of positive or negative pulses that are >, <, =, or ≠ a specified period of time (4 ns to 8 s)
TimeoutTrigger when no pulse is detected within a specified time (4 ns to 8 s)
RuntTrigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again
LogicTrigger when any logical pattern of channels goes false or stays true for specified period of time (4 ns to 8 s). Any input can be used as a clock to look for the pattern on a clock edge. Pattern (AND, OR, NAND, NOR) specified for all analog and digital input channels defined as High, Low, or Don't Care
Setup and HoldTrigger on violations of both setup time and hold time between clock and data present on any of the input channels
Rise/Fall TimeTrigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative, or either
VideoTrigger on all lines, odd, even, or all fields on NTSC, PAL, and SECAM video signals
Extended Video (Optional)Trigger on 480p/60, 576p/50, 720p/30, 720p/50, 720p/60, 875i/60, 1080i/50, 1080i/60, 1080p/24, 1080p/24sF, 1080p/25, 1080p/30, 1080p/50, 1080p/60, and custom bi-level and tri-level sync video standards
I²C (Optional)Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data, or Address and Data on I²C buses up to 10 Mb/s
SPI (Optional)Trigger on SS active, MOSI, MISO, or MOSI and MISO on SPI buses up to 50 Mb/s
USB (Optional)Low-speed: Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special Packet, Error.Token packet trigger – Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any Token, OUT, IN, and SETUP token types. Address can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular value, or inside or outside of a range. Frame number can be specified for SOFToken using binary, hex, unsigned decimal and don't care digits.Data packet trigger – Any data type, DATA0, DATA1; Data can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular data value, or inside or outside of a range.Handshake packet trigger – Any handshake type, ACK, NAK, STALL.Special packet trigger – Any special type, Reserved.Error trigger – PID Check, CRC5 or CRC16, Bit Stuffing.
Full-speed: Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special Packet, Error.Token packet trigger – Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any Token, OUT, IN, and SETUP token types. Address can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular value, or inside or outside of a range.Framme number can be specified for SOFToken using binary, hex, unsigned decimal and don't care digits.Data packet trigger – Any data type, DATA0, DATA1; Data can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular data value, or inside or outside of a range.Handshake packet trigger – Any handshake type, ACK, NAK, STALL.Special packet trigger – Any special type, PRE, Reserved.Error trigger – PID Check, CRC5 or CRC16, Bit Stuffing.
High-speed: Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special Packet, Error.Token packet trigger – Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any Token, OUT, IN, and SETUP token types. Address can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular value, or inside or outside of a range.SOF token using binary, hex, unsigned decimal and don't care digits.Data packet trigger – Any data type, DATA0, DATA1, DATA2, DATAM; Data can be further specified to trigger on ≤, <, =, >, ≥, ≠ a particular data value, or inside or outside of a range.Handshake packet trigger – Any handshake type, ACK, NAK, STALL, NYET.Special packet trigger – Any special type, ERR, SPLIT, PING; Reserved. SPLIT packet components that can be specified include:Hub AddressStart/Complete – Don't Care, Start (SSPLIT), Complete (CSPLIT)Port AddressStart and End bits – Don't Care, Control/Bulk/Interrupt (Full-speed Device, Low-speed Device), Isochronous (Data is Middle, Data is End, Data is Start, Data is All)Endpoint Type – Don't Care, Control, Isochronous, Bulk, InterruptError trigger – PID Check, CRC5 or CRC16, Any.
High-speed support only available on MSO4104B and DPO4104B models.
Ethernet (Optional)10BASE-T: Trigger on Start Frame Delimiter, MAC Addresses, MAC Q-Tag Control Information, MAC Length/Type, IP Header, TCP Header,TCP/IPv4/MAC Client Data, End of Packet, FCS (CRC) Error.MAC Addresses – Trigger on Source and Destination 48-bit address values.MAC Q-Tag Control Information – Trigger on Q-Tag 32-bit value.MAC Length/Type – Trigger on ≤, <, =, >, ≥, ≠ a particular 16-bit value, or inside or outside of a range.IP Header – Trigger on IP Protocol 8-bit value, Source Address, Destination Address.TCP Header – Trigger on Source Port, Destination Port, Sequence Number, and Ack Number.TCP/IPv4/MAC Client Data – Trigger on ≤, <, =, >, ≥, ≠ a particular data value, or inside or outside of a range. Selectable number of bytes to trigger on from 1-16. Byte offset options of Don't Care, 0-1499.
100BASE-TX: Trigger on Start Frame Delimiter, MAC Addresses, MAC Q-Tag Control Information, MAC Length/Type, IP Header, TCP Header,TCP/IPv4/MAC Client Data, End of Packet, Idle, FCS (CRC) Error.MAC Addresses – Trigger on Source and Destination 48-bit address values.MAC Q-Tag Control Information – Trigger on Q-Tag 32-bit value.MAC Length/Type – Trigger on ≤, <, =, >, ≥, ≠ a particular 16-bit value, or inside or outside of a range.IP Header – Trigger on IP Protocol 8-bit value, Source Address, Destination Address.TCP Header – Trigger on Source Port. Destination Port, Sequence Number, and Ack Number.TCP/IPv4/MAC Client Data – Trigger on ≤, <, =, >, ≥, ≠ a particular data value, or inside or outside of a range. Selectable number of bytes to trigger on from 1-16. Byte offset options of Don't Care, 0-1499.
CAN (Optional)Trigger on Start of Frame, Frame Type (data, remote, error, overload), Identifier (standard or extended), Data, Identifier and Data, End of Frame, Missing ACK, or Bit Stuffing Error on CAN signals up to 1 Mb/s. Data can be further specified to trigger on ≤, <, =, >, ≥, or ≠ a specific data value.User-adjustable sample point is set to 50% by default
LIN (Optional)Trigger on Sync, Identifier, Data, Identifier and Data, Wakeup Frame, Sleep Frame, Errors such as Sync, Parity, or Checksum Errors up to 100 Kb/s (by LIN definition, 20 Kb/s)
FlexRay (Optional)Trigger on Start of Frame, Type of Frame (Normal, Payload, Null, Sync, Startup), Identifier, Cycle Count, Complete Header Field, Data, Identifier and Data, End of Frame or Errors such as Header CRC, Trailer CRC, Null Frame, Sync Frame, or Startup Frame Errors up to 100 Mb/s
RS-232/422/485/UART (Optional)Trigger on Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx End of Packet, Tx Data, Rx Data, Tx Parity Error, and Rx Parity Error up to 10 Mb/s
MIL-STD-1553 (Optional)Trigger on Sync, Word Type, Parity Error. Data can be further specified to trigger on ≤, <, =, >, ≥, ≠ a specific data value, or inside or outside of a range.
I2S/LJ/RJ/TDM (Optional)Trigger on Word Select, Frame Sync, or Data. Data can be further specified to trigger on ≤, <, =, >, ≥, ≠ a specific data value, or inside or outside of a rangeMaximum data rate for I2S/LJ/RJ is 12.5 Mb/sMaximum data rate for TDM is 25 Mb/s
Parallel (Available on MSO models only)Trigger on a parallel bus data value. Parallel bus can be from 1 to 20 bits in size. Binary and Hex radices are supported

Acquisition Modes

ModeDescription
SampleAcquire sampled values
Peak DetectCaptures glitches as narrow as 800 ps (1 GHz models) or 1.6 ns (500 MHz and 350 MHz models) at all sweep speeds
AveragingFrom 2 to 512 waveforms included in average
EnvelopeMin-Max envelope reflecting Peak Detect data over multiple acquisitions
Hi ResReal-time boxcar averaging reduces random noise and increases vertical resolution
RollScrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms/div

Waveform Measurements

MeasurementDescription
CursorsWaveform and Screen
Automatic Measurements29, of which up to four can be displayed on-screen at any one time. Measurements include: Period, Frequency, Delay, Rise Time, Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive Overshoot, Negative Overshoot, Peak-to-Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle RMS, Positive Pulse Count, Negative Pulse Count, Rising Edge Count, Falling Edge Count, Area and Cycle Area
Measurement StatisticsMean, Min, Max, Standard Deviation
Reference LevelsUser-definable reference levels for automatic measurements can be specified in either percent or units
GatingIsolate the specific occurrence within an acquisition to take measurements on, using either the screen or waveform cursors
Waveform HistogramA waveform histogram provides an array of data values representing the total number of hits inside of a user-defined region of the display. A waveform histogram is both a visual graph of the hit distribution as well as a numeric array of values that can be measured. Sources – Channel 1, Channel 2, Channel 3, Channel 4, Ref 1, Ref 2, Ref 3, Ref 4, Math Types – Vertical, Horizontal
Waveform Histogram MeasurementsWaveform Count, Hits in Box, Peak Hits, Median, Max, Min, Peak-to-Peak, Mean, Standard Deviation, Sigma 1, Sigma 2, Sigma 3

Waveform Math

CharacteristicDescription
ArithmeticAdd, subtract, multiply, and divide waveforms
Math FunctionsIntegrate, Differentiate, FFT
FFTSpectral magnitude
FFT Vertical Scale: Linear RMS or dBV RMS
FFT Window Settings: Rectangular, Hamming, Hanning, Blackman Harris
Advanced MathDefine extensive algebraic expressions including waveforms, reference waveforms, math functions. Perform math on math using complex equations (FFT, Intg, Diff, Log, Exp, Squ, Abs, Sine, Cosine, Tangent, Rad, Deg), scalars, up to two user-adjustable variables and results of parametric measurements (Period, Freq, Delay, Rise, Fall, PosWidth, NegWidth, BurstWidth, Phase, PosDutyCycle, NegDutyCycle, PosOverShoot, NegOverShoot, PeakPeak, Amplitude, RMS, CycleRMS, High, Low, Max, Min, Mean, CycleMean, Area, CycleArea, and trend plots) e.g. (Intg(Ch1-Mean(Ch1))×1.414×VAR1)

Power Measurements (Optional)

MeasurementDescription
Power Quality MeasurementsVRMS, VCrest Factor, Frequency, IRMS, Icrest Factor, True Power, Apparent Power, Reactive Power, Power Factor, Phase Angle
Switching Loss MeasurementsPower Loss: Ton, Toff, Conduction, Total
Energy Loss: Ton, Toff, Conduction, Total
HarmonicsTHD-F, THD-R, RMS measurements
Graphical and table displays of harmonics
Test to IEC61000-3-2 Class A and MIL-STD-1399
Ripple MeasurementsVripple and Iripple
Modulation AnalysisGraphical display of +Pulse Width, -Pulse Width, Period, Frequency, +Duty Cycle, and -Duty Cycle modulation types
Safe Operating AreaGraphical display and mask testing of switching device safe operating area measurements
dV/dt and dl/dt MeasurementsCursor measurements of slew rate

Limit/Mask Testing (Optional)

CharacteristicDescription
Included Standard MasksITU-T, ANSI T1.102, USB
Test SourceLimit Test: Any Ch1 - Ch4 or any R1 - R4 Mask Test: Any Ch1 - Ch4
Mask CreationLimit test vertical tolerance from 0 to 1 division in 1 m division increments; Limit test horizontal tolerance from 0 to 500 m division in 1 m division increments
Load standard mask from internal memory
Load custom mask from text file with up to 8 segments
Mask ScalingLock to Source ON (mask automatically re-scales with source-channel settings changes) Lock to Source OFF (mask does not re-scale with source-channel settings changes)
Test Criteria Run UntilMinimum number of waveforms (from 1 to 1,000,000; Infinity) Minimum elapsed time (from 1 second to 48 hours; Infinity)
Violation ThresholdFrom 1 to 1,000,000
Actions on Test FailureStop acquisition, save screen image to file, save waveform to file, print screen image, trigger out pulse, set remote interface SRQ
Actions on Test CompleteTrigger out pulse, set remote interface SRQ
Results DisplayTest status, total waveforms, number of violations, violation rate, total tests, failed tests, test failure rate, elapsed time, total hits for each mask segment

Software

SoftwareDescription
NI LabVIEWA fully interactive measurement software environment optimized for the MSO/DPO4000B Series, enables you to instantly acquire, generate, analyze, compare, import, and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming.
SignalExpress Tektronix EditionStandard MSO/DPO4000B Series support for acquiring, controlling, viewing, and exporting your live signal data is permanently available through the software. The full version (SIGEXPTE) adds additional signal processing, advanced analysis, mixed signal, sweeping, limit testing, and user-defined step capabilities and is available for a 30-day trial period standard with each instrument.
OpenChoice® DesktopEnables fast and easy communication between a Windows PC and the MSO/DPO4000B Series, using USB or LAN. Transfer and save settings, waveforms, measurements, and screen images. Included Word and Excel toolbars automate the transfer of acquisition data and screen images from the oscilloscope into Word and Excel for quick reporting or further analysis.
IVI DriverProvides a standard instrument programming interface for common applications such as LabVIEW, LabWindows/CVI, Microsoft .NET and MATLAB.
e*Scope®Enables control of the MSO/DPO4000B Series over a network connection through a standard web browser. Simply enter the IP address or network name of the oscilloscope followed by :81 (to represent connecting through Port 81) and a web page will be served to the browser
LXI Class C Web InterfaceConnect to the MSO/DPO4000B Series through a standard web browser by simply entering the oscilloscope's IP address or network name in the address bar of the browser. The web interface enables viewing of instrument status and configuration, and status and modification of network settings. All web interaction conforms to LXI Class C specification.

Display Characteristics

CharacteristicDescription
Display Type10.4 in. (264 mm) liquid-crystal TFT color display
Display Resolution1,024 horizontal × 768 vertical pixels (XGA)
Waveform StylesVectors, Dots, Variable Persistence, Infinite Persistence
GraticulesFull, Grid, Solid, Cross Hair, Frame, IRE, and mV
FormatYT and simultaneous XY/YT
Waveform Capture Rate>50,000 wfm/s maximum

Input/Output Ports

PortDescription
USB 2.0 High-speed Host PortSupports USB mass storage devices, printers and keyboard. Two ports on front and two ports on rear of instrument
USB 2.0 Device PortRear-panel connector allows for communication/control of oscilloscope through USBTMC or GPIB (with a TEK-USB-488), and direct printing to all PictBridge-compatible printers
LAN PortRJ-45 connector, supports 10/100/1000 Mb/s
XGA Video PortDB-15 female connector, connect to show the oscilloscope display on an external monitor or projector
Auxiliary InputFront-panel BNC connector. Input Impedance 1 MΩ. Max input 300 VRMS CAT II with peaks ≤ ±425 V
Probe Compensator OutputFront-panel pins Amplitude: 2.5 V Frequency: 1 kHz
Auxiliary OutRear-panel BNC connector VOUT(Hi): ≥2.5 V open circuit, ≥1.0 V 50 Ω to ground VOUT(Lo): ≤0.7 V into a load of ≤4 mA; ≤0.25 V 50 Ω to ground Output can be configured to provide a pulse out signal when the oscilloscope triggers, the internal oscilloscope reference clock out, or an event out for limit/mask testing
External Reference InTime-base system can phase lock to an external 10 MHz reference (10 MHz ±1%)
Kensington LockRear-panel security slot connects to standard Kensington lock

LAN eXtensions for Instrumentation (LXI)

CharacteristicDescription
ClassLXI Class C
VersionV1.3

Power Source

CharacteristicDescription
Power Source Voltage100 to 240 V ±10%
Power Source Frequency45 to 66 Hz (85 to 264 V) 360 to 440 Hz (100 to 132 V)
Power Consumption225 W maximum

Physical Characteristics

Dimensionsmmin.
Height2299.0
Width43917.3
Depth1475.8
Weightkglb.
Net511
Shipping10.723.6
Rackmount Configuration5U
Cooling Clearance2 in. (51 mm) required on left side and rear of instrument
VESA MountStandard (MIS-D 100) 100 mm VESA mounting points on rear of instrument

Environmental

CharacteristicDescription
Temperature
Operating0 °C to +50 °C
Nonoperating-20 °C to +60 °C
Humidity
OperatingHigh: 40 °C to 50 °C, 10% to 60% Relative Humidity Low: 0 °C to 40 °C, 10% to 90% Relative Humidity
NonoperatingHigh: 40 °C to 60 °C, 5% to 60% Relative Humidity Low: 0 °C to 40 °C, 5% to 90% Relative Humidity
Altitude
Operating9,843 ft. (3,000 m)
Nonoperating30,000 ft. (9,144 m)
Regulatory
Electromagnetic CompatibilityEC Council Directive 2004/108/EC
SafetyUL61010-1, Second Edition; CSA61010-1 Second Edition, EN61010-1:2001; IEC 61010-1:2001

Ordering Information

MSO/DPO4000B Family

ModelDescription
DPO4000B Models
DPO4034B350 MHz, 2.5 GS/s, 20M record length, 4-channel digital phosphor oscilloscope
DPO4054B500 MHz, 2.5 GS/s, 20M record length, 4-channel digital phosphor oscilloscope
DPO4104B1 GHz, 5 GS/s, 20M record length, 4-channel digital phosphor oscilloscope
MSO4000B Models
MSO4034B350 MHz, 2.5 GS/s, 20M record length, 4+16 channel mixed signal oscilloscope
MSO4054B500 MHz, 2.5 GS/s, 20M record length, 4+16 channel mixed signal oscilloscope
MSO4104B1 GHz, 5 GS/s, 20M record length, 4+16 channel mixed signal oscilloscope

All Models Include: One passive voltage probe per analog channel (TPP0500 500 MHz, 10X, 3.9 pF for 500 MHz and 350 MHz models; TPP1000 1 GHz, 10X, 3.9 pF for 1 GHz models), Front Cover (200-5130-xx), User Manual (071-2810-xx), Documentation CD (063-4300-xx), OpenChoice® Desktop Software, NI LabVIEW SignalExpress™ Tektronix Edition Software, Calibration Certificates document measurement traceability to National Metrology Institute(s) – the Quality System this product is manufactured in is ISO9001 registered, power cord, accessory bag (016-2029-xx) and a three-year warranty. Please specify power plug and manual language version when ordering.

MSO Models also Include: One P6616 16-channel logic probe and a logic probe accessory kit (020-2662-xx).

Application Modules

ModuleDescription
DPO4AEROAerospace Serial Triggering and Analysis Module. Enables triggering on packet-level information on MIL-STD-1553 buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information. Signal Inputs – Any Ch1 - Ch4 (and any D0 - D15 on MSO models) Recommended Probing – Single ended
DPO4AUDIOAudio Serial Triggering and Analysis Module. Enables triggering on packet-level information on I2S, LJ, RJ, and TDM audio buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information. Signal Inputs – Any Ch1 - Ch4 (and any D0 - D15 on MSO models) Recommended Probing – I2S, LJ, RJ, TDM: Single ended
DPO4AUTOAutomotive Serial Triggering and Analysis Module. Enables triggering on packet-level information on CAN and LIN buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information. Signal Inputs – LIN: Any Ch1 - Ch4 (and any D0 - D15 on MSO models); CAN: Any Ch1 - Ch4 (and any D0 - D15 on MSO models), single-ended probing only Recommended Probing – LIN: Single ended; CAN: Single ended or differential
DPO4AUTOMAXExtended Automotive Serial Triggering and Analysis Module. Enables triggering on packet-level information on CAN, LIN, and FlexRay buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, packet decode tables with time-stamp information, and eye diagram analysis software. Signal Inputs – LIN: Any Ch1 - Ch4 (and any D0 - D15 on MSO models); CAN: Any Ch1 - Ch4 (and any D0 - D15 on MSO models), single-ended probing only; FlexRay: Any Ch1 - Ch4 (and any D0 - D15 on MSO models), single-ended probing only Recommended Probing – LIN: Single ended; CAN, FlexRay: Single ended or differential
DPO4COMPComputer Serial Triggering and Analysis Module. Enables triggering on packet-level information on RS-232/422/485/JUART buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information. Signal Inputs – Any Ch1 - Ch4 (and any D0 - D15 on MSO models), single-ended probing only Recommended Probing – RS-232/JUART: Single ended; RS-422/485: Differential

Module Description

DPO4EMBDEmbedded Serial Triggering and Analysis Module. Enables triggering on packet-level information on I2C and SPI buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information. Signal Inputs - I2C: Any Ch1 - Ch4 (and any D0 - D15 on MSO models); SPI: Any Ch1 - Ch4 (and any D0 - D15 on MSO models) Recommended Probing - I2C, SPI: Single ended
DPO4ENETEthernet Serial Triggering and Analysis Module. Enables triggering on packet-level information on 10BASE-T and 100BASE-TX buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information. Signal Inputs - Any Ch1 - Ch4 Recommended Probing - 10BASE-T: Single ended or differential; 100BASE-TX: Differential
DPO4USBUSB Serial Triggering and Analysis Module. Enables triggering on packet-level content for low-speed, full-speed, and high-speed USB serial buses. Also enables analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information for low-speed, full-speed, and high-speed USB serial buses. Signal Inputs - Low-speed and Full-speed: Any Ch1 - Ch4 (and any D0 - D15 on MSO models) for single ended, Any Ch1 - Ch4 for differential; High-speed: Any Ch1 - Ch4 Recommended Probing - Low-speed and Full-speed: Single ended or differential; High-speed: Differential USB high-speed supported only on MSO4104B and DPO4104B models
DPO4PWRPower Analysis Application Module. Enables quick and accurate analysis of power quality, switching loss, harmonics, safe operating area (SOA), modulation, ripple, and slew rate (dI/dt, dV/dt)
DPO4LMTLimit and Mask Testing Application Module. Enables testing against limit templates generated from "golden" waveforms and mask testing using custom or standard telecommunications or computer masks
DPO4VIDHDTV and Custom (nonstandard) Video Triggering Module

Instrument Options

Power Plug Options

OptionDescription
Opt. A0North America
Opt. A1Universal Euro
Opt. A2United Kingdom
Opt. A3Australia
Opt. A5Switzerland
Opt. A6Japan
Opt. A10China
Opt. A11India
Opt. A99No power cord or AC adapter

Language Options*1

OptionDescription
Opt. L0English manual
Opt. L1French manual
Opt. L2Italian manual
Opt. L3German manual
Opt. L4Spanish manual
Opt. L5Japanese manual
Opt. L6Portuguese manual
Opt. L7Simplified Chinese manual
Opt. L8Traditional Chinese manual
Opt. L9Korean manual
Opt. L10Russian manual
Opt. L99No manual

*1 Language options include a translated front-panel overlay for the selected language(s).

Service Options*2

OptionDescription
Opt. CA1Provides a single calibration event, or coverage for the designated calibration interval, whichever comes first.
Opt. C3Calibration Service 3 years
Opt. C5Calibration Service 5 years
Opt. D1Calibration Data Report
Opt. D3Calibration Data Report 3 years (with Opt. C3)
Opt. D5Calibration Data Report 5 Years (with Opt. C5)
Opt. R5Repair Service 5 years (including warranty)

*2 Probes and accessories are not covered by the oscilloscope warranty and service offerings. Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms.

Tektronix offers over 100 different probes to meet your application needs. For a comprehensive listing of available probes, please visit wwwTektronix.com/probes.

ProbeDescription
TPP0500500 MHz, 10X TekVPI® passive voltage probe with 3.9 pF input capacitance
TPP10001 GHz, 10X TekVPI passive voltage probe with 3.9 pF input capacitance
TAP15001.5 GHz TekVPI active single-ended voltage probe
TDP15001.5 GHz TekVPI differential voltage probe with ±25 V differential input voltage
TDP10001 GHz TekVPI differential voltage probe with ±42 V differential input voltage
TDP0500500 MHz TekVPI differential voltage probe with ±42 V differential input voltage
TCP015020 MHz TekVPI 150 Ampere AC/DC current probe
TCP0030120 MHz TekVPI 30 Ampere AC/DC current probe
P52001.3 kV, 25 MHz high-voltage differential probe
P5205*31.3 kV, 100 MHz high-voltage differential probe
P5210*35.6 kV, 50 MHz high-voltage differential probe
P51002.5 kV, 100X high-voltage passive probe

*3 Requires TekVPI® to TekProbe BNC adapter (TPA-BNC).

Recommended Accessories

AccessoryDescription
077-0512-xxService Manual (English only)
SIGEXPTENI LabVIEW SignalExpress™ Tektronix Edition Software (Full Version)
FPGAView-xxMSO Support for Altera and Xilinx FPGAs
TPA-BNCTekVPI-to-TekProbe BNC Adapter
TEK-USB-488GPIB-to-USB Adapter
ACD4000BSoft Transit Case
HCTEK54Hard Transit Case (Requires ACD4000B)
RMD5000Rackmount Kit
TEK-DPGDeskew Pulse Generator
067-1686-xxDeskew Fixture

Warranty

Three-year warranty covering all parts and labor, excluding probes.

C

TEKTRONIX DPO4054B - C - 1

Product(s) are manufactured in ISO registered facilities.

TEKTRONIX DPO4054B - C - 2

Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats.

For Further Information

Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com

TEKTRONIX DPO4054B - For Further Information - 1

Copyright © 2010, Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies.

20 Oct 2010

3GF-20156-9

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : TEKTRONIX

Model : DPO4054B

Category : Oscilloscope