USER MANUAL TDS2000C TEKTRONIX
Digital Storage Oscilloscopes
TDS2000C Series Data Sheet

Features & Benefits
Key Performance Specifications
200 MHz, 100 MHz, 70 MHz, 50 MHz Bandwidth Models
2-and 4-channel Models
Up to 2 GS/s Sample Rate on All Channels
2.5k point Record Length on All Channels
Advanced Triggers including Pulse Width Trigger and Line-selectable Video Trigger
Ease-of-Use Features
16 Automated Measurements, and FFT Analysis for Simplified Waveform Analysis
Built-in Waveform Limit Testing
Automated, Extended Data Logging Feature
Autoset and Signal Auto-ranging
Built-in Context-sensitive Help
Probe Check Wizard
Multiple-language User Interface
5.7 in. (144 mm) Active TFT Color Display
- Small Footprint and Lightweight - Only 4.9 in. (124 mm) Deep and 4.4 lb. (2 kg)
Connectivity
USB 2.0 Host Port on the Front Panel for Quick and Easy Data Storage
USB 2.0 Device Port on Rear Panel for Easy Connection to a PC or Direct Printing to a PictBridge®-compatible Printer
- Includes National Instrument's LabVIEW SignalExpress™ TE Limited Edition and Tektronix OpenChoice® Software for Connecting Your Bench
Lifetime Warranty*1
*1 Limitations apply. For terms and conditions, visit wwwTektronix.com/lifetimewarranty.

Quickly and easily capture waveforms with advanced triggering.
Performance You Need at a Price You Can Afford
The TDS2000C Digital Storage Oscilloscope Series provides you with affordable performance in a compact design. Packed with standard features – including USB connectivity, 16 automated measurements, limit testing, data logging, and context-sensitive help – the TDS2000C Series oscillosopes help you get more done, in less time.
Digital Precision for Accurate Measurements
With up to 200 MHz bandwidth and 2 GS/s maximum sample rate, no other digital storage oscilloscope offers as much bandwidth and sample rate for the price. Tektronix proprietary sampling technology provides real-time sampling with a minimum of 10X oversampling on all channels, all the time to accurately capture your signals. Sampling performance is not reduced when using multiple channels.
Critical Tools for Troubleshooting Your Device
Advanced triggers – rising/falling edge, pulse width, and video – help you quickly isolate your signals of interest. Once you've captured a signal, advanced math capabilities and automated measurements can speed your analysis. Quickly perform an FFT or add, subtract, or multiply waveforms. Sixteen automated measurements quickly and reliably calculate important signal characteristics such as frequency or rise time, while the built-in Limit Test function enables you to easily identify problems in your signal.

See all the details other oscillosopes might miss with Tektronix proprietary digital real-time sampling.

Quickly perform an FFT with the advanced math functions.
Designed to Make Your Work Easy
The TDS2000C Series oscillosopes are designed with the ease of use and familiar operation you have come to expect from Tektronix.
Intuitive Operation
The intuitive user interface with dedicated per-channel vertical controls, auto-setup, and auto-ranging makes these instruments easy to use, reducing learning time and increasing efficiency.

The context-sensitive Help system provides important information specific to the task you are working on.

Limit Test provides a quick pass/fail comparison of any triggered input signal to a user-defined template.
Help When You Need It, Where You Need It
The built-in Help menu provides you with important information on your oscilloscope's features and functions. Help is provided in the same languages as the user interface.
Probe Check Wizard
Check out your probe compensation before making measurements with just one button that starts a fast, easy procedure.
Limit Test
The oscilloscope can automatically monitor source signals and output Pass or Fail results by judging whether the input waveform is within predefined

Data Logging enables automatic saving of triggered waveforms for up to 8 hours.

Conveniently use your USB flash drive to store screenshots and waveform data.
boundaries. Specific actions can be triggered on violation including stopping waveform acquisition, stopping Limit Test functions, saving the failed waveform data or screen image to a USB memory device, or any combination of the above. This is an ideal solution for manufacturing or service applications where you need to make decisions quickly.
Flexible Data Transfer
The USB host port on the front panel enables you to save your instrument settings, screenshots, and waveform data in a flash. The built-in data logging feature means you can set up your oscilloscope to save user-specified triggered waveforms to a USB memory device for up to 8 hours.

Easily capture, save, and analyze measurement results with included National Instrument's LabVIEW SignalExpress, Limited Tektronix Edition software.
Easy PC Connectivity
Easily capture, save, and analyze measurements results by connecting to your PC with the rear-panel USB device port and the included copy of OpenChoice PC Communications Software. Simply pull screen images
and waveform data into the stand-alone desktop application or directly into Microsoft Word and Excel. Alternatively, if you prefer not to use your PC, you can simply print your image directly to any PictBridge-compatible printer.
Connect Your Bench for Intelligent Debug
Every TDS2000C Series oscilloscope ships with an included copy of the Limited Tektronix Edition of National Instrument's LabVIEW SignalExpress for basic instrument control, data logging, and analysis.
SignalExpress supports the range of Tektronix bench instruments*2 enabling you to connect your entire test bench. You can then access the feature-rich tools packed into each instrument from one intuitive software interface. This allows you to automate complex measurements requiring multiple instruments, log data for an extended period of time, time correlate data from multiple instruments, and easily capture and analyze your results, all from your PC. Only Tektronix offers a connected test bench of intelligent instruments to simplify and speed debug of your complex design.
Performance You Can Count On
In addition to industry-leading service and support, every TDS2000C Series oscilloscope comes backed with a Lifetime Warranty*1 as standard.
1 Limitations apply. For terms and conditions, visit wwwTektronix.com/lifetimewarranty.
2 For a complete listing of Tektronix instruments supported by NI LabVIEW Signal Express, visit www.tektronix.com/signalexpress.
Characteristics
TDS2000C Series Digital Storage Oscilloscopes
| TDS2001C | TDS2002C | TDS2004C | TDS2012C | TDS2014C | TDS2022C | TDS2024C | |
| Display (QVGA LCD) | TFT | TFT | TFT | TFT | TFT | TFT | TFT |
| Bandwidth*3 | 50 MHz | 70 MHz | 70 MHz | 100 MHz | 100 MHz | 200 MHz | 200 MHz |
| Channels | 2 | 2 | 4 | 2 | 4 | 2 | 4 |
| External Trigger Input | |||||||
| Sample Rate on Each Channel | 500 MS/s | 1.0 GS/s | 1.0 GS/s | 2.0 GS/s | 2.0 GS/s | 2.0 GS/s | 2.0 GS/s |
| Record Length | |||||||
| Vertical Resolution | |||||||
| Vertical Sensitivity | |||||||
| DC Vertical Accuracy | |||||||
| Vertical Zoom | |||||||
| Maximum Input Voltage | |||||||
| Position Range | |||||||
| Bandwidth Limit | |||||||
| Input Coupling | |||||||
| Input Impedance | |||||||
| Time Base Range | 5 ns to 50 s/div | 5 ns to 50 s/div | 5 ns to 50 s/div | 2.5 ns to 50 s/div | 2.5 ns to 50 s/div | 2.5 ns to 50 s/div | 2.5 ns to 50 s/div |
| Time Base Accuracy | |||||||
| Horizontal Zoom | |||||||
| I/O Interfaces | |||||||
| USB Ports | |||||||
| GPIB | |||||||
| Nonvolatile Storage | |||||||
| Reference Waveform Display | |||||||
| Waveform Storage without USB Flash Drive | (2) 2.5k point | (2) 2.5k point | (4) 2.5k point | (2) 2.5k point | (4) 2.5k point | (2) 2.5k point | (4) 2.5k point |
| Maximum USB Flash Drive Size | |||||||
| Waveform Storage with USB Flash Drive | |||||||
| Setup with USB Flash Drive | |||||||
| Setup with USB Flash Drive | |||||||
| Screen Images with USB Flash Drive | |||||||
| Save All with USB Flash Drive | |||||||
*3 Bandwidth is 20 MHz at 2 mV/div, all models.
Acquisition Modes
| Mode | Description |
| Peak Detect | High-frequency and random glitch capture. Captures glitches as narrow as 12 ns (typical) at all time base settings from 5 μs/div to 50 s/div |
| Sample | Sample data only |
| Average | Waveform averaged, selectable: 4, 16, 64, 128 |
| Single Sequence | Use the Single Sequence button to capture a single triggered acquisition sequence |
| Roll | At acquisition time base settings of >100 ms/div |
Trigger System
| Characteristic | Description |
| Trigger Modes | Auto, Normal, Single Sequence |
Trigger Types
| Trigger | Description |
| Edge (Rising/Falling) | Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject |
| Video | Trigger on all lines or individual lines, odd/even or all fields from composite video, or broadcast standards (NTSC, PAL, SECAM) |
| Pulse Width (or glitch) | Trigger on a pulse width less than, greater than, equal to, or not equal to, a selectable time limit ranging from 33 ns to 10 s |
Trigger Source
| Characteristic | Description |
| 2-channel Models | CH1, CH2, Ext, Ext/5, AC Line |
| 4-channel Models | CH1, CH2, CH3, CH4, Ext, Ext/5, AC Line |
Trigger View
Displays trigger signal while Trigger View button is depressed.
Trigger Signal Frequency Readout
Provides a frequency readout of the trigger source.
Cursors
| Characteristic | Description |
| Types | Amplitude, Time |
| Measurements | ΔT, 1/ΔT, ΔV |
Automatic Waveform Measurements
Period, Frequency, +Width, -Width, Rise Time, Fall Time, Max, Min, Peak-to-Peak, Mean, RMS, Cycle RMS, Cursor RMS, Duty Cycle, Phase, Delay
Waveform Math
| Characteristic | Description |
| Operators | Add, Subtract, Multiply, FFT |
| FFT | Windows: Hanning, Flat Top, Rectangular 2048 sample points |
| Sources | |
| 2-channel models | CH1 – CH2, CH2 – CH1, CH1 + CH2, CH1 × CH2 |
| 4-channel models | CH1 – CH2, CH2 – CH1, CH3 – CH4, CH4 – CH3, CH1 + CH2, CH3 + CH4, CH1 × CH2, CH3 × CH4 |
Autoset Menu
Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems, with undo Autoset.
| Signal Type | Autoset Menu Choices |
| Square Wave | Single Cycle, Multicycle, Rising or Falling Edge |
| Sine Wave | Single Cycle, Multicycle, FFT Spectrum |
| Video (NTSC, PAL, SECAM) | Field: All, Odd, or Even Line: All or Selectable Line Number |
Autorange
Automatically adjust vertical and/or horizontal oscilloscope settings when probe is moved from point to point, or when the signal exhibits large changes.
Display Characteristics
| Characteristic | Description |
| Display | QVGA Active Color TFT |
| Interpolation | Sin(x)/x |
| Display Types | Dots, vectors |
| Persistence | Off, 1 s, 2 s, 5 s, infinite |
| Format | YT and XY |
Multiple-language User Interface and Context-sensitive Help
| Characteristic | Description |
| Languages Available | English, French, German, Italian, Japanese, Korean, Portuguese, Russian*4, Simplified Chinese, Spanish, Traditional Chinese |
*4 Requires Russian firmware, indicated by "RUS" suffix.
Environmental and Safety
| Characteristic | Description |
| Temperature | |
| Operating | 0 to +50 °C |
| Nonoperating | -40 to +71 °C |
| Humidity | |
| Operating and nonoperating | Up to 80% RH at or below +40 °C Up to 45% RH up to +50 °C |
| Altitude | |
| Operating and nonoperating | Up to 3,000 m |
| Electromagnetic Compatibility | Meets Directive 2004/108/EC, EN 61326-2-1 Class A; Australian EMC Framework |
| Safety | UL61010-1:2004, CSA22.2 No. 61010-1:2004, EN61010-1:2001, IEC61010-1:2001 |
Physical Characteristics
Instrument
| Dimensions | mm | in. |
| Width | 326.3 | 12.85 |
| Height | 158.0 | 6.22 |
| Depth | 124.2 | 4.89 |
| Weight | kg | lb. |
| Instrument Only | 2.0 | 4.4 |
| With accessories | 2.2 | 4.9 |
| Instrument Shipping | ||
| Package Dimensions | mm | in. |
| Width | 476.2 | 18.75 |
| Height | 266.7 | 10.5 |
| Depth | 228.6 | 9.0 |
| RM2000B Rackmount | mm | in. |
| Width | 482.6 | 19.0 |
| Height | 177.8 | 7.0 |
| Depth | 108.0 | 4.25 |
Ordering Information
Models
| Model | Description |
| TDS2001C | 50 MHz, 2 Ch, 500 MS/s, TFT DSO |
| TDS2002C | 70 MHz, 2 Ch, 1 GS/s, TFT DSO |
| TDS2004C | 70 MHz, 4 Ch, 1 GS/s, TFT DSO |
| TDS2012C | 100 MHz, 2 Ch, 2 GS/s, TFT DSO |
| TDS2014C | 100 MHz, 4 Ch, 2 GS/s, TFT DSO |
| TDS2022C | 200 MHz, 2 Ch, 2 GS/s, TFT DSO |
| TDS2024C | 200 MHz, 4 Ch, 2 GS/s, TFT DSO |
Standard Accessories
| Accessory | Description |
| Passive Probes | TPP0101: 100 MHz passive probe for TDS2001C/TDS2002C/TDS2004C |
| TPP0201: 200 MHz passive probe for TDS2012C/TDS2014C/TDS2022C/TDS2024C | |
| Power Cord | (Please specify plug option) |
| NIM/NIST | Traceable Certificate of Calibration |
| Documentation | User Manual (Please specify preferred language option) |
| OpenChoice PC Communications Software | Enables fast and easy communication between a Windows PC and the TDS2000C Series using USB. Transfer and save settings, waveforms, measurements, and screen images |
| National Instruments SignalExpress Tektronix Edition Interactive Measurement Software – Base Version | A fully interactive measurement software environment optimized for the TDS2000C Series. Enables you to instantly acquire, generate, analyze, compare, import, and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming. Standard TDS2000C Series support for acquiring controlling, viewing, and exporting your live signal. A 30-day trial period of the Professional Version provides additional signal processing, advance analysis, mixed signal, sweeping, limit testing, and user-defined step capabilities. Order SIGEXPTE for permanent Professional Version capability |
| Limited Lifetime Warranty*5 | Covers labor and parts for defects in materials and workmanship for a minimum of 10 years, excluding probes and accessories*6 |
5 Lifetime is defined as 5 years after Tektronix discontinues manufacturing the product, but the warranty length shall be at least ten years from date of original purchase. Lifetime warranty is nontransferable, proof of original purchase is required. Limitations apply. For terms and conditions visit www.tektronix.com/lifetimewarranty.
6 Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the data sheet of each probe and accessory model for its unique warranty and calibration terms.
Power Plug Options
| Option | Description |
| A0 | North America |
| A1 | Universal Euro |
| A2 | United Kingdom |
| A3 | Australia |
| A5 | Switzerland |
| A6 | Japan |
| A10 | China |
| A11 | India |
| A99 | No power cord or AC adapter |
Translated front-panel overlays included with their respective user manuals.
User Manual Options
| Option | Description |
| L0 | English manual |
| L1 | French manual |
| L2 | Italian manual |
| L3 | German manual |
| L4 | Spanish manual |
| L5 | Japanese manual |
| L6 | Portuguese manual |
| L7 | Simple Chinese manual |
| L8 | Standard Chinese manual |
| L9 | Korean manual |
| L10 | Russian manual |
Recommended Accessories
| Accessory | Description |
| TEK-USB-488 | GPIB-to-USB converter |
| SIGEXPTE | National Instruments SignalExpress Tektronix Edition Interactive Measurement Software – Professional Version |
| AC2100 | Soft Carrying Case for Instrument |
| HCTEK4321 | Hard Plastic Carrying Case for Instrument (requires AC2100) |
| RM2000B | Rackmount Kit |
| 071-1075-xx | Programmer Manual – English Only |
| 071-1828-xx | Service Manual – English Only |
| 174-4401-xx | USB host to device cable, 3 ft. long |
Recommended Probes
| Probe | Description |
| TPP0101 | 10X Passive Probe, 100 MHz bandwidth |
| TPP0201 | 10X Passive Probe, 200 MHz bandwidth |
| P2220 | 1X/10X Passive Probe, 200 MHz bandwidth |
| P6101B | 1X Passive Probe (15 MHz, 300 VRMS CAT II rating) |
| P6015A | 1000X High-voltage Passive Probe (75 MHz) |
| P5100 | 100X High-voltage Passive Probe (250 MHz) |
| P5200 | High-voltage Active Differential Probe (25 MHz) |
| P6021 | 15 A, 60 MHz AC-current Probe |
| P6022 | 6 A, 120 MHz AC-current Probe |
| A621 | 2000 A, 5 to 50 kHz AC-current Probe |
| A622 | 100 A, 100 kHz AC/DC Current Probe/BNC |
| TCP303/TCPA300 | 150 A, 15 MHz AC/DC Current Probe/Amplifier |
| TCP305/TCPA300 | 50 A, 50 MHz AC/DC Current Probe/Amplifier |
| TCP312/TCPA300 | 30 A, 100 MHz AC/DC Current Probe/Amplifier |
| TCP404XL/TCPA400 | 500 A, 2 MHz AC/DC Current Probe/Amplifier |
Service Options*6
| Option | Description |
| C3 | Calibration Service 3 Years |
| C5 | Calibration Service 5 Years |
| D1 | Calibration Data Report |
| D3 | Calibration Data Report 3 Years (with Opt. C3) |
| D5 | Calibration Data Report 5 Years (with Opt. C5) |
| CA1 | Provides a single calibration event or coverage for the designated calibration interval, whichever comes first |
*6 Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the data sheet of each probe and accessory model for its unique warranty and calibration terms.
Service Offerings (Available after purchase)
| Option | Description |
| TDSxxxxC-CA1 | Provides a single calibration event or coverage for the designated calibration interval, whichever comes first |



Product(s) are manufactured in ISO registered facilities.
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats.
For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com

Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies.
28 Oct 2010
3GW-25645-0
Tektronix