KAZ HCM-350B-CST - Air Humidifier

HCM-350B-CST - Air Humidifier KAZ - Free user manual and instructions

Find the device manual for free HCM-350B-CST KAZ in PDF.

📄 28 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice KAZ HCM-350B-CST - page 1
View the manual : Français FR English EN Español ES
Pick your language and provide your email: we'll send you a specifically translated version.
Type Cool Mist Humidifier
Brand KAZ / Honeywell
Model HCM-350B-CST
Tank Capacity 7.6 liters (2 US gallons)
Daily Output 7.6 liters per day
Power Supply 120 V, 60 Hz
Filter Wick Filter, model HAC-504AW
Germicidal UV Lamp Part HCM-350-UV, lifespan 3000 h
Fan Speeds High (HIGH), Medium (MED), Low (LOW)
Features 99.9% germ elimination (bacteria, fungi, mold, viruses)
Power Indicator Light Green (normal operation) / Red (UV replacement needed)
Cleaning Descaling with vinegar, disinfection with bleach
Dishwasher Safe Tank (except cap)
Warranty 3-year limited
Replacement Parts Available Filter HAC-504AW, tank HCM-350-TANK/HCM-350B-TANK, UV bulb HCM-350-UV, cap HCM-350-CAP/HCM-350B-CAP

Frequently Asked Questions - HCM-350B-CST KAZ

Why do I see no mist coming out of my humidifier?
The unit produces invisible, balanced humidity air. You will only feel cool air. To check operation, monitor the water level drop in the tank over 24 hours. If the water level drops, the humidifier is working normally.
My fan is running but the water level is not dropping, what should I do?
First check that the filter is wet. If it is dry, remove it from the base and gently rinse it under cool water, then replace it while damp. If the ambient humidity exceeds 60%, the unit produces less moisture because the air is already saturated.
The filter has turned brown or rust-colored, should I replace it?
Probably not. The discoloration is due to mineral deposits. Soak the filter in cool water to break up these deposits. The color may persist without affecting performance. The filter has an antimicrobial treatment ProTecMC.
My humidifier emits an unpleasant odor, what should I do?
It is probably time to replace the ProTecMC antimicrobial cartridge. If you have been using the unit regularly for more than 30 days, replace the cartridge and follow the cleaning instructions (descaling with vinegar then disinfection with bleach).
How do I replace the UV bulb?
Unplug the unit, remove the tank and the top cover. Turn the cover upside down, remove the bulb cover by unscrewing 4 screws. Replace the bulb with a new one (HCM-350-UV) without touching it with bare hands to avoid reducing its lifespan. Replace the cover and screw it back on. The bulb lasts about 3000 hours.
How do I clean the humidifier?
Turn off and unplug. Remove the tank, cover, and filter. For descaling, wipe the tray and tank with a cloth soaked in undiluted vinegar, then rinse. For disinfection, pour 5 ml of bleach into 3.8 L of water in the tank, wipe the tray with this solution, then rinse thoroughly until no odor remains.
Which filter should I use and how to change it?
Use a replacement filter HAC-504AW. Unplug the unit, remove the tank and top cover. Remove the old filter, soak the new one in cool water without wringing it out, then place it damp in the unit. Reassemble everything.
What safety precautions should I observe?
Place the humidifier on a flat, level surface, out of reach of children. Do not place near heat sources. Use only on a polarized 120 V outlet. Do not pull the cord to unplug. Always unplug before moving or cleaning. Do not direct the airflow directly towards people or furniture.
My humidifier does not work on an uneven surface, why?
The humidifier requires a firm, level surface to operate correctly. If it is tilted, the level sensor may prevent startup. Always place it on a level floor.
How should I store the unit at the end of the season?
Completely descale and disinfect the unit. Discard the used filter. Ensure all parts are thoroughly dry. Put the unit back in its original packaging. Before next use, clean and install a new filter.

User questions about HCM-350B-CST KAZ

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air Humidifier in PDF format for free! Find your manual HCM-350B-CST - KAZ and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HCM-350B-CST by KAZ.

USER MANUAL HCM-350B-CST KAZ

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HUMIDIFIER

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following

  1. Always place this humidifier on a firm, flat and level surface. This humidifier may not work properly on an uneven surface.
  2. Place this humidifier in an area where it is not accessible to children.
  3. Do not place the humidifier near any heat sources such as stoves, radiators, and heaters.
  4. Do not use the humidifier outdoors.
  5. Before using the humidifier, check the power cord for any signs of damage. If the cord is found to be damaged, DO NOT USE and return the humidifier to the manufacturer under the warranty agreement for repair.
  6. This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit securely in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
  7. To disconnect the humidifier, first turn controls to the OFF position, then grip the plug and pull it from the wall outlet. Never pull by the cord.
  1. A loose fit between the AC outlet (receptacle) and plug may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn outlet.
  2. The humidifier should always be unplugged and emptied when not in operation or while being serviced or cleaned.
  3. Never tilt or attempt to move the humidifier while it is operating or filled with water. UNPLUG the humidifier before moving.
  4. This humidifier requires regular cleaning. Refer to the CLEANING instructions provided. Never clean the humidifier in any manner other than as instructed in this manual.
  5. Do not direct moisture flow directly at individuals, walls or furniture.
  6. When a humidifier is used in a closed room or small rooms, check periodically for proper ventilation, as excessive humidity can cause condensation stains on walls.
  7. Turn the humidifier OFF if you notice moisture on the inside of your windows. For proper humidity reading use a hygrometer, which is available in many hardware and department stores, or by ordering one from the manufacturer.

The sealed UV bulbs contain a small amount of mercury. Dispose of these items at household hazardous waste collection sites only. If the UV bulb breaks, do not vacuum or handle with your bare hands.

HOW DOES IT WORK? GERM FREE COOL MIST SYSTEM

Once the filled water tank is in place, water is delivered to the UV and wicking systems. When the unit is on, the water moves very slowly past the UV system. This is ample time to destroy germs, fungus and mold that may be present in the water. The water is then delivered to the filter/wick. This saturated wick not only filters the air, but also provides moisture to the humidifier fan, which in turn, delivers germ free* moisture to the room.

Your humidifier is made up of these parts:

KAZ HCM-350B-CST - Your humidifier is made up of these parts: - 1
* Based on independent testing, report 3175067COL-001. Results are based on microbial reduction rate testing performed using tap water in the water tray. The following listed microorganism growth reduction was maintained after 2 hours of continuous exposure to the ultraviolet light in the humidifier.

Bacteria: Escherichia Coli 99.9% Fungus: Penicillium Citrinum 99.9%

Mold: Aspergillus niger 99.9% Virus: MS2 99.9%

SETTING UP YOUR HUMIDIFIER AND PLACEMENT

Remove from box. Remove packaging material. Remove and set aside OM instructions. Recycle box and packaging materials or save box for end of season storage

Select a firm, level location at least 6" (15cm) from any walls and furniture for proper airflow. Place the humidifier on a water resistant surface, as water can damage furniture and some flooring.

Kaz will not accept responsibility for property damage caused by water spillage.

KAZ HCM-350B-CST - SETTING UP YOUR HUMIDIFIER AND PLACEMENT - 1

OPERATION

KAZ HCM-350B-CST - OPERATION - 1
Remove tank and fill.

KAZ HCM-350B-CST - OPERATION - 2
Lift off upper enclosure.

KAZ HCM-350B-CST - OPERATION - 3
Remove filter and soak in cool water.

KAZ HCM-350B-CST - OPERATION - 4
Replace wet filter into unit and reassemble.

KAZ HCM-350B-CST - OPERATION - 5
Fill tank with water and replace filled tank.

KAZ HCM-350B-CST - OPERATION - 6
Make sure unit is off.

KAZ HCM-350B-CST - OPERATION - 7
Plug into polarized 120V outlet.

KAZ HCM-350B-CST - OPERATION - 8
Set fan speed.

FAN SPEEDS

KAZ HCM-350B-CST - FAN SPEEDS - 1

HIGH: For fast humidifying

KAZ HCM-350B-CST - FAN SPEEDS - 2

MED: For everyday moisture control

KAZ HCM-350B-CST - FAN SPEEDS - 3

LOW: For quiet operation (ideal for nighttime use)

CHANGING FILTER

KAZ HCM-350B-CST - CHANGING FILTER - 1
Filter HAC-504AW.

KAZ HCM-350B-CST - CHANGING FILTER - 2
Turn off and unplug unit.

KAZ HCM-350B-CST - CHANGING FILTER - 3
Remove water tank.

KAZ HCM-350B-CST - CHANGING FILTER - 4
Lift off upper enclosure.

KAZ HCM-350B-CST - CHANGING FILTER - 5
Remove and discard used filter.

KAZ HCM-350B-CST - CHANGING FILTER - 6
Soak new filter in cool water.

KAZ HCM-350B-CST - CHANGING FILTER - 7
Do not wring or squeeze.

KAZ HCM-350B-CST - CHANGING FILTER - 8
Place wet filter into unit.

KAZ HCM-350B-CST - CHANGING FILTER - 9
Replace upper enclosure.

KAZ HCM-350B-CST - CHANGING FILTER - 10
Replace water tank.

CHANGING UV BULB

The UV bulb will operate for an average output of 3,000 hours. To replace UV bulb contact 1-800-477-0457 or consumerrelations@kaz.com.

Note: Power light will turn from Green to Red when UV light needs to be replaced.

KAZ HCM-350B-CST - CHANGING UV BULB - 1
Turn off and unplug unit.

KAZ HCM-350B-CST - CHANGING UV BULB - 2
Remove and empty water tank.

KAZ HCM-350B-CST - CHANGING UV BULB - 3
Lift off upper enclosure.

KAZ HCM-350B-CST - CHANGING UV BULB - 4
Turn enclosure over.

KAZ HCM-350B-CST - CHANGING UV BULB - 5
Locate UV Bulb cover.

KAZ HCM-350B-CST - CHANGING UV BULB - 6
Remove 4 screws with Phillips screw driver.

KAZ HCM-350B-CST - CHANGING UV BULB - 7
Remove bulb and bulb socket from holder.

KAZ HCM-350B-CST - CHANGING UV BULB - 8
Unscrew and discard old bulb.

KAZ HCM-350B-CST - CHANGING UV BULB - 9
Insert new bulb and bulb socket firmly into holder. Do not handle new bulb with bare hands as oils can reduce bulb life.

KAZ HCM-350B-CST - CHANGING UV BULB - 10
Replace cover and tighten 4 screws firmly. Re-assemble unit.

WARNING:

REPLACE UV GERMICIDAL BULB WITH ONE OF THE SAME TYPE (HCM-350-UV). BULB AVAILABLE FROM KAZ INC. SEE INSTRUCTIONS OR CONTACT KAZ CUSTOMER SERVICE.

KAZ HCM-350B-CST - WARNING: - 1

NOTE: Discard the old UV bulb cartridge at a household hazardous waste collection site. Bulb and bulb housing are not intended for use with any other product or purpose. Lamp contains mercury. Manage in accordance with disposal laws.

See www.lamprecycle.org or call 1-800-895-8842.

CLEANING

Water tank is dishwasher safe and can be used for disinfecting. DO NOT PUT TANK CAP IN DISHWASHER.

Cleaning base and tank cap involves two steps, SCALE REMOVAL and DISINFECTING. Be sure to perform these in the proper order to avoid harmful chemical interactions.

NOTE: REMOVE FILTER BEFORE SCALE REMOVAL OR DISINFECTING.

Failure to remove filter during cleaning will destroy the filter.

SCALE REMOVAL

KAZ HCM-350B-CST - SCALE REMOVAL - 1
Turn off and unplug unit.

KAZ HCM-350B-CST - SCALE REMOVAL - 2
Remove and empty water tank.

KAZ HCM-350B-CST - SCALE REMOVAL - 3
Lift off upper enclosure.

KAZ HCM-350B-CST - SCALE REMOVAL - 4
Remove Filter.

KAZ HCM-350B-CST - SCALE REMOVAL - 5
Wipe base, tank cap and tank with undiluted vinegar.

KAZ HCM-350B-CST - SCALE REMOVAL - 6
Rinse thoroughly.

DISINFECTING if dishwasher is not available

KAZ HCM-350B-CST - DISINFECTING if dishwasher is not available - 1
Turn off and unplug unit.

KAZ HCM-350B-CST - DISINFECTING if dishwasher is not available - 2
Remove and empty water tank.

KAZ HCM-350B-CST - DISINFECTING if dishwasher is not available - 3
Lift off upper enclosure.

KAZ HCM-350B-CST - DISINFECTING if dishwasher is not available - 4
Remove filter.

CLEANING continued

KAZ HCM-350B-CST - CLEANING continued - 1

Fill water tank with 1 tsp bleach and 1 gallon cool water.

KAZ HCM-350B-CST - CLEANING continued - 2

Wipe base with same solution.

KAZ HCM-350B-CST - CLEANING continued - 3

Rinse until smell of bleach is gone.

END-OF-SEASON CARE AND STORAGE

Clean and disinfect unit.

Do not store with used filter.

Make sure unit is dry.

Pack unit in original carton.

Clean and install new filter before next use.

CONSUMER RELATIONS

Mail questions or comments to:

Kaz, Incorporated

Consumer Relations Dept.

250 Turnpike Road

Southborough, MA 01772

Please be sure to specify model number.

Call us toll-free at: 1-800-477-0457

E-mail: consumerrelations@kaz.com

Or visit our website at: www.kaz.com

TO ORDER REPLACEMENT PARTS

Replacement Filter Part # HAC-504AW

HCM-350:

Replacement part # HCM-350-TANK

Replacement part # HCM-350-UV

Replacement part # HCM-350-CAP

HCM-350B/HCM-350B-CST:

Replacement part # HCM-350B-TANK

Replacement part # HCM-350-UV

Replacement part # HCM-350B-CAP

ELECTRICAL RATINGS

The Honeywell HCM-350 Series models are rated at 120V, 60 Hz.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE HUMIDIFIER TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING OR TAMPER WITH INTERLOCK SWITCH YOURSELF, DOING SO MAY Void YOUR WARRANTY AND CAUSE DAMAGE TO THE PRODUCT OR PERSONAL INJURY.

TROUBLESHOOTING

Q: I hear the fan turning, but I don't see any mist. Is my humidifier operating properly?

A: Dry air is pulled through the system and a fan disperses invisible, moisture balanced air. There is no "mist" emitted. When operating normally you will feel only cool air coming from the unit. Monitor the water level in your Tank/ Base. If you notice a decrease in the Water Tank over 24 hours then the unit is operating normally.
Q: My unit has been running for several hours. I hear the fan spinning, but I do not notice the water level in the tank decreasing.
A: First, check the filter to ensure it is wet. If the pad appears dry, remove it from the Base and gently rinse under cool water. Reposition wet filter in the Base. You may also want to note the current moisture level in your home. If the humidity level is over 60% the unit will not put out much moisture as your air is already saturated. Also verify the upper enclosure and water tank are properly seated.
Q: My filter has turned light brown and rust colored. Do I need a new filter?
A: Probably not. Since your filter has been made with Protec™ antimicrobial the change in color indicates only a mineral deposit. Soak filter in a sink full of cool water to help break up deposits. The discoloration may remain but will not affect the humidifier's performance.
Q: My humidifier doesn't appear to be as clean as when I first purchased and/or I'm smelling an unpleasant odor. What should I do?
A: You probably need to replace your Protec™ Antimicrobial Cartridge. This cartridge helps your humidifier stay cleaner, longer and helps freshen the mist. If you have been using your humidifier regularly for over 30 days replace the Protec™ cartridge and follow the cleaning instructions.

3 YEAR LIMITED WARRANTY

You should first read all instructions before attempting to use this product.

A. This 3 year limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. It also does not apply to the filter or Protec™ Antimicrobial Cartridge. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty.

KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.

Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.

B. At its option, Kaz will repair or replace this product if it is found to be defective in material or workmanship.

C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.
D. Return defective product to Kaz, Incorporated with a brief description of the problem. Include proof of purchase and a 10 US/ 15.50 CAN check or money order for handling, return packing and shipping charges. Please include your name, address and a daytime phone number.

You must prepay shipping charges. We suggest having tracking or delivery confirmation. Send to:

In U.S.A.:

Kaz, Incorporated

Attn: Returns Department

4755 Southpoint Drive

Memphis, TN 38118

USA

In Canada:

Kaz Canada, Inc.

Attn: Returns Department

510 Bronte Street South

Milton, ON L9T 2X6

Canada

Please go to www.kaz.com and register your product under the Customer Care Center and receive product information updates and new promotional offers.

KAZ HCM-350B-CST - In Canada: - 1

IMPORTANT INSTRUCTIONS DE SECURITÉ

LIRE CES INSTRUCTIONS DE SÉCURITE AVANT D'UTILISER L'HUMIDIFICATEUR

REEMPLACEMENT DE L'AMPOULE UV

Consumer Relations Dept.

250 Turnpike Road

Southborough, MA 01772

USA

Kaz, Incorporated
Attn: Returns Department
4755 Southpoint Drive
Memphis, TN 38118
USA

Au Canada:

Kaz Canada, Inc.
Attn: Returns Department
510 Bronte Street South
Milton, ON L9T 2X6
Canada

Moho: Aspergillus niger 99.9% Virus: MS2 99.9%

Failure to remove filter during cleaning will destroy the filter.

Consumer Relations Dept.

250 Turnpike Road

Southborough, MA 01772

USA

Attn: Returns Department

4755 Southpoint Drive

Memphis, TN 38118

USA

En Canada:

Kaz Canada, Inc.

Attn: Returns Department

510 Bronte Street South

Milton, ON L9T 2X6

Canada

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : KAZ

Model : HCM-350B-CST

Category : Air Humidifier