CECOTEC

Surface Precision Ecopower 10000 Healthy - Scale CECOTEC - Free user manual and instructions

Find the device manual for free Surface Precision Ecopower 10000 Healthy CECOTEC in PDF.

📄 42 pages English EN Download 💬 AI Question
Notice CECOTEC Surface Precision Ecopower 10000 Healthy - page 1
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about Surface Precision Ecopower 10000 Healthy CECOTEC

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Scale in PDF format for free! Find your manual Surface Precision Ecopower 10000 Healthy - CECOTEC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Surface Precision Ecopower 10000 Healthy by CECOTEC.

USER MANUAL Surface Precision Ecopower 10000 Healthy CECOTEC

  1. Safety instructions 9
  2. Parts and components 10
  3. Before use 10
  4. Operation 10
  5. Technical specifications 11
  6. Disposal of old electrical appliances 11
  7. Technical support and warranty 11

SOMMAIRE

Fig./Img./Abb./Afb./Rys./Obr. 2

CECOTEC Surface Precision Ecopower 10000 Healthy - SOMMAIRE - 1

Fig./Img./Abb./Afb./Rys./Obr. 3

CECOTEC Surface Precision Ecopower 10000 Healthy - SOMMAIRE - 2

Fig./Img./Abb./Afb./Rys./Obr. 4

CECOTEC Surface Precision Ecopower 10000 Healthy - SOMMAIRE - 3

Fig./Img./Abb./Afb./Rys./Obr. 5

1. SAFETY INSTRUCTIONS

Read these instructions thoroughly before using the appliance. Keep this instruction manual for future reference or new users. This device is designed for personal use only and is not suitable for commercial or industrial use.

Do not leave children and animals unsupervised with the device and keep the packaging material away from them in order to prevent suffocation.

Do not operate this appliance if there are any visible signs of damage. Always check for damage before each use and in case of malfunction, contact the Technical Support Service of Cecotec.

Keep the device away from electromagnetic fields (mobile telephones, remote controls, etc.). Measurement accuracy could be affected.

Keep the device away from heat sources.

Do not use the device outdoors.

  1. Do not expose the device to extreme temperatures, moisture, wet conditions or direct sunlight.

Keep water and other liquids away from the device.

Wide temperature variations could cause condensation. In this case, allow the device to go back to room temperature before use.

Do not drop the device or jump on its measuring surface.

Do not stand on the scale with wet feet and make sure the measuring surface and the surface underneath is dry.

Do not stand on the edge of the scale.

Do not use caustic or abrasive cleaning materials to clean the device, this could damage the surface.

ENGLISH

2. PARTS AND COMPONENTS

Fig. 1

  1. LCD display
  2. EcoPower push button
  3. High-security tempered glass platform
  4. Measuring unit push button
  5. High-precision sensor

3. BEFORE USE

Take the device out of its package and remove all packaging material.

Check carefully if there is any damage. If there is, immediately notify the Technical Support Service of Cecotec.

4. OPERATION

Fig. 2

Place the device on a solid, dry and flat surface (avoid carpets). Uneven floors will result in inaccurate measurement results.

Gently stamp on the push button, this will automatically generate battery. Wait until "0.0" is displayed.

The scale will automatically turn off after 1 minute.

Note: Do not step on the scale until "0.0" is displayed.

Fig. 3

Error indication:

"Err" will indicate overload, when more than 180 kg are places on the scale.

Fig. 4

When a battery icon appears next to the digits in the display, the scale will turn automatically off after a few seconds due to low battery. Simply stamp on the push button again to generate more power.

Fig. 5

Unit switch:

The display will show "Kg" or "Ib" below the battery icon, indicating which measuring unit is being used at that moment. Press the unit button to switch from one unit to another.

Note: The unit must be changed before stepping on the scale, not during weighing.

5. TECHNICAL SPECIFICATIONS

04250 Surface Precision EcoPower 10000 Healthy White

04251 Surface Precision EcoPower 10000 Healthy Black

Equipped with high-precision strain gauge sensor system.

Capacity: 180 kg/396 lb

No. of units: Kg-lb

Mini effective weight: 8 kg

5-mm tempered safety glass platform

Automatic power generation control

Battery-free technology

Auto zero resetting/auto power off

Low battery/overload indicator

6. DISPOSAL OF OLD ELECTRICAL APPLIANCES

CECOTEC Surface Precision Ecopower 10000 Healthy - DISPOSAL OF OLD ELECTRICAL APPLIANCES - 1

The European directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE), specifies that old household electrical appliances must not be disposed of with the normal unsorted municipal waste. Old appliances must be collected separately, in order to optimize the recovery and recycling of the materials they contain, and reduce the impact on human health and the environment.

The crossed out “wheeled bin” symbol on the product reminds you of your obligation to dispose of the appliance correctly. Consumers must contact their local authorities or retailer for information concerning the correct disposal of old appliances and/or their batteries.

7. TECHNICAL SUPPORT AND WARRANTY

This product is under warranty for 2 years from the date of purchase, as long as the proof of purchase is submitted, the product is in perfect physical condition, and it has been given proper use, as explained in this instruction manual.

The warranty will not cover the following situations:

The product has been used for purposes other than those intended for it, misused, beaten,

ENGLISH

exposed to moisture, immersed in liquid or corrosive substances, as well as any other fault attributable to the customer.

The product has been disassembled, modified, or repaired by persons, not authorised by the official Technical Support Service of Cecotec.

Faults deriving from the normal wear and tear of its parts, due to use.

The warranty service covers every manufacturing defects of your appliance for 2 years, based on current legislation, except consumable parts. In the event of misuse, the warranty will not apply.

If at any moment you detect any problem with your product or have any doubt, do not hesitate to contact Cecotec Technical Support Service at +34 963 210 728.

1. INSTRUCTIONS DE SÉCURITÉ

Surface Precision EcoPower 10000 Healthy White

Surface Precision EcoPower 10000 Healthy White

Quart de Poblet, Valencia (Spain)

YV01191231

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : CECOTEC

Model : Surface Precision Ecopower 10000 Healthy

Category : Scale