| Product Type | Electronic time switch |
| Brand | Hager |
| Model | ACC906T |
| Category | Switches |
| Rated Voltage | 230 V AC |
| Frequency | 50/60 Hz |
| Number of Channels | 1 |
| Switching Capacity | 16 A (resistive) |
| Mounting Type | DIN rail 35 mm |
| Program Duration | 24-hour daily cycle |
| Shortest Switching Interval | 15 minutes |
| Manual Override | Yes |
| Status Indication | LED indicator |
| Terminal Wire Size | 0.5 to 2.5 mm² |
| Protection Rating | IP20 |
| Operating Temperature | -5°C to +45°C |
| Storage Temperature | -20°C to +60°C |
| Dimensions (W x H x D) | 35.6 x 60.6 x 66.2 mm |
| Weight | 150 g |
| Housing Material | Self-extinguishing plastic |
| Standards | EN 60730-1, EN 60730-2-7 |
| Maintenance | Clean with a dry cloth only |
| Spare Parts | No user-serviceable parts |
| Repairability | Unit must be replaced on failure |
Frequently Asked Questions - ACC906T HAGER
What is the Hager ACC906T used for?
The Hager ACC906T is a time switch designed to automatically turn electrical circuits on and off according to a daily program. It is commonly used for lighting, heating, and ventilation control.
How do I set the current time on the ACC906T?
Turn the dial in the direction indicated to align the marking with the current time. For precise setting, use the manual knob and check against a reliable clock.
How do I program the switching times?
The ACC906T has programming tabs around the dial. Push the tabs outward for the intervals where the output should be ON and leave them pressed in for OFF. Each tab represents 15 minutes.
What is the maximum electrical load it can switch?
The device can switch resistive loads up to 16 A at 230 V AC, which is equivalent to approximately 3680 W. For inductive or capacitive loads, always check derating.
Can I use this time switch with LED lighting?
Yes, the ACC906T can control LED lighting as long as the total load does not exceed the rated switching capacity and inrush current limits. Use a contactor for LED banks with high inrush.
How do I perform a manual override?
A manual override switch is located on the front. Move it to the ON or OFF position to temporarily override the program. Return it to AUTO to resume normal cycle.
What does the LED indicator mean?
The LED indicator shows the current switching state. When lit, the output is energized. When off, the output is de-energized.
Is the ACC906T suitable for outdoor installation?
No, the protection rating is IP20, meaning it is protected against solid objects over 12 mm but not against water. Install it inside an IP65 rated enclosure if used outdoors.
What should I do if the device does not keep time?
If the clock stops or loses time, there may be a power failure or the mechanical movement is damaged. The device is not field repairable; replace the time switch with a new unit.
What tools are needed for installation?
You need a flathead screwdriver for terminal screws and a slotted screwdriver for DIN rail mounting. Ensure power is disconnected before installation.
User questions about ACC906T HAGER
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Switches in PDF format for free! Find your manual ACC906T - HAGER and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ACC906T by HAGER.