Type of Product Digital Multimeter
Brand RTS
Model 4030-M
Display 3.5-digit LCD, 20 mm digit height
DC Voltage Range 200 mV, 2 V, 20 V, 200 V, 600 V (±0.5%)
AC Voltage Range 200 V, 600 V (±1.2%)
DC Current Range 200 µA, 2 mA, 20 mA, 200 mA, 10 A (±1.0%)
Resistance Range 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ, 20 MΩ (±0.8%)
Diode Test Yes
Transistor Test Yes (hFE)
Continuity Test Audible if resistance < 100 Ω
Data Hold Yes
Power Supply 9 V battery (6F22)
Dimensions 138 × 69 × 31 mm
Weight 170 g (including battery)
Safety Rating CAT II 600 V
Included Accessories Test leads, battery, user manual
Operating Temperature 0 °C to 40 °C
Storage Temperature -10 °C to 50 °C
Warranty 1 year

Frequently Asked Questions - 4030-M RTS

How do I measure DC voltage with the RTS 4030-M?
Set the rotary switch to the DC voltage position (V⎓). Connect the black test lead to the COM terminal and the red lead to the VΩ terminal. Touch the probes to the circuit. Read the value on the LCD display. Start with the highest range to avoid overload.
How do I measure AC voltage?
Turn the dial to the AC voltage position (V~). Insert the black lead into COM and the red lead into VΩ. Apply the probes to the live and neutral wires. The multimeter displays the RMS voltage. For the 4030-M, AC voltage ranges are 200V and 600V.
How do I measure resistance?
Select the resistance mode (Ω). Connect the probes to the COM and VΩ ports. Ensure the circuit is de-energized before measuring. Touch the probes to the resistor. Wait for the reading to stabilize. The 4030-M has a resolution of 0.1Ω up to 20MΩ.
How do I perform a continuity test?
Turn the dial to the continuity setting ())). Insert the probes. If the resistance is below 100Ω, the built-in buzzer sounds. Disconnect power before testing.
How do I test a diode?
Use the diode test mode (). Connect the red probe to the anode and the black to the cathode. The forward voltage drop is displayed in millivolts. For silicon diodes, expect about 0.5-0.8V.
How do I measure DC current?
For currents up to 200mA, insert the red lead into the mA jack. For up to 10A, use the 10A jack. Select the appropriate current range. Connect the meter in series with the load. Ensure the current does not exceed the fuse rating.
How do I replace the battery?
Turn off the multimeter and disconnect the test leads. Remove the screw on the back cover. Open the case, slide out the old 9V battery, and replace it with a new 6F22 battery. Reattach the cover and screw.
What does 'OL' mean on the display?
OL indicates an overload or an open circuit. When measuring resistance, it means the resistance exceeds the selected range. When measuring voltage, it means the input is beyond the range.
Can the 4030-M measure temperature?
No, the RTS 4030-M does not have a temperature measurement function. Only voltage, current, resistance, diode, and continuity tests are supported.
What safety precautions should I follow?
Never measure voltages above 600V. Use appropriate terminals and ranges. Inspect the test leads for damage. Do not use the multimeter in humid environments. Always start with the highest range.

User questions about 4030-M RTS

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual 4030-M - RTS and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 4030-M by RTS.

USER MANUAL 4030-M RTS

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : RTS

Model : 4030-M

Category : Uncategorized