TEPC 125 - Water heater Rheem - Free user manual and instructions
Find the device manual for free TEPC 125 Rheem in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Electric Water Heater |
| Model | TEPC 125 |
| Brand | Rheem |
| Capacity | 125 L (33 gal) |
| Dimensions (H x W x D) | 1200 x 500 x 500 mm |
| Weight (empty) | 40 kg |
| Power Supply | 240 V / 60 Hz |
| Heating Power | 2400 W |
| Temperature Range | 10 °C – 60 °C |
| Safety Devices | TPR valve, thermostat with ECO |
| Material | Steel tank with vitreous enamel |
| Anode Rod | Magnesium (replaceable) |
| Installation | Wall-mounted or vertical floor |
| Energy Efficiency Class | B (EU) |
| Recovery Rate | ~90 L/h at 45 °C rise |
| First Hour Rating | ~150 L |
| Control | Thermostatic dial |
| Suitable for | Residential hot water supply |
| Included Accessories | Safety valve, user manual |
Frequently Asked Questions - TEPC 125 Rheem
How do I reset the Rheem TEPC 125 water heater after a power outage?
Locate the reset button on the upper thermostat (under the access panel). Press firmly until it clicks. Wait for the tank to heat up.
Why is there no hot water coming from my Rheem TEPC 125?
Check if the circuit breaker is tripped or the reset button needs pressing. Also ensure the thermostat is set above 40 °C. If still no hot water, the heating element may need replacement.
How to adjust the temperature on the Rheem TEPC 125?
Open the upper access panel and adjust the thermostat dial using a flat screwdriver. Recommended setting is 55-60 °C to prevent Legionella growth.
How often should I replace the anode rod?
Inspect the magnesium anode rod annually. Replace it when it is less than 10 mm thick or if it is coated with calcium. Typically every 3-5 years.
Why is the water heater leaking?
Check the TPR valve (temperature/pressure relief) – it may be releasing due to high pressure. Also inspect tank for corrosion around the anode rod or water connections.
How do I drain the Rheem TEPC 125 for winterizing?
Turn off power and cold water supply. Attach a hose to the drain valve at the bottom. Open a hot tap for venting, then open the drain valve. Let water flow until empty.
What is the warranty period for the TEPC 125?
Rheem typically offers a 6-year warranty on the tank and 2 years on parts for residential use. Check your specific purchase documentation.
Can I use the water heater without a TPR valve?
No. The TPR valve is a critical safety device. Operating without it can cause excessive pressure buildup, leading to explosion risk. Always keep it installed.
How to clean sediment from the bottom of the tank?
Perform a partial flush by draining a few litres via the drain valve every 6 months. For heavy sediment, drain completely and refill.
What should I do if the water is too hot?
Lower the thermostat setting to a safer temperature (e.g., 50 °C). If the water remains too hot, the thermostat might be faulty; replace it.