TEPC 85 - Water heater Rheem - Free user manual and instructions
Find the device manual for free TEPC 85 Rheem in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Electric Water Heater |
| Model | TEPC 85 |
| Brand | Rheem |
| Capacity | 85 Gallons |
| Dimensions (H x D) | 62.25 x 28.5 inches |
| Weight | 220 lbs |
| Power Supply | 240V / 30A |
| Heating Elements | Two 5500W elements |
| Energy Factor | 0.92 |
| First Hour Rating | 82 Gallons |
| Maximum Temperature | 150°F (adjustable) |
| Thermostat Type | Dual upper/lower thermostats |
| Safety Features | T&P relief valve, auto shut-off |
| Anode | Sacrificial anode (replaceable) |
| Installation | Indoor/outdoor, electric only |
| Maintenance | Drain tank yearly, replace anode every 3-5 years |
| Parts | Heating elements, thermostats, anode, T&P valve |
| Repairability | DIY-friendly; spare parts available |
Frequently Asked Questions - TEPC 85 Rheem
How do I drain my Rheem TEPC 85 water heater?
Turn off power or gas. Attach a garden hose to the drain valve at the bottom. Open the valve and let water flow. Open a hot water faucet inside your home to allow air in. Drain completely. Close the valve and remove hose.
What is the recommended temperature setting?
The recommended setting is 120°F (49°C) to prevent scalding and save energy. You can adjust via the thermostats behind the access panels.
How often should I replace the anode rod?
Inspect the sacrificial anode rod every 2-3 years. Replace it if more than 6 inches of core wire is exposed or if it's heavily corroded. Typical replacement is every 3-5 years.
Why is my water heater making a popping noise?
Popping noises are usually due to sediment buildup on the bottom heating element. Drain and flush the tank to remove sediment. Use a commercial sediment reducer if needed.
How do I reset the high-limit switch?
Locate the red reset button on the upper thermostat (behind the upper access panel). Press it firmly. If it trips again, there may be a thermostat issue or overheating.
What size breaker do I need for the TEPC 85?
The TEPC 85 typically requires a 30-amp double-pole breaker with 10 AWG copper wire. Always consult a licensed electrician.
How do I test the temperature and pressure relief valve?
Lift the lever on the T&P valve for a few seconds. Hot water should discharge. Release the lever; it should snap closed tightly. If it leaks or fails, replace it immediately.
Can the TEPC 85 be used in an outdoor installation?
Yes, it is rated for outdoor installation as long as it is protected from direct rain and weather. Use a weatherproof cover if needed.
What is the warranty coverage?
Typically 6 years on the tank and 1 year on parts. Check your specific manual for details. Extended warranties may be available.
How do I replace a heating element?
Turn off power, drain water, remove access panel, disconnect wires, unscrew the element with a socket wrench. Install new element, reattach wires, fill tank, check for leaks, restore power.