| Product Type | Heavy-Duty Electronic Timer |
| Model | P40000RT1 |
| Brand | Intermatic |
| Voltage Rating | 240 VAC, 60 Hz |
| Current Rating | 40 A resistive, 40 A inductive |
| Horsepower Rating | 1 HP (120 V), 2 HP (240 V) |
| Number of Outlets | 1 |
| Timer Mechanism | Electronic, 24-hour or 7-day programming |
| Minimum On/Off Time | 1 minute |
| Enclosure Material | Metal, weather-resistant |
| Dimensions (W x H x D) | 8 x 6 x 4 inches |
| Weight | 2.5 lbs |
| Wiring Connection | Screw terminals |
| Power Supply | 240 VAC, 60 Hz |
| Primary Functions | Automatic on/off scheduling for pool pumps, lighting, and other equipment |
| Programmability | Up to 4 on/off events per day |
| Manual Override | Yes, toggle switch |
| Safety Certifications | UL Listed, CSA Certified |
| Maintenance | Wipe with a dry cloth; keep vents clean |
| Spare Parts Availability | Replacement mechanisms and enclosures available |
| Repairability | Customer replaceable timer module; professional installation recommended |
| Warranty | 1 year limited |
Frequently Asked Questions - P40000RT1 INTERMATIC
How do I set the current time on the P40000RT1?
To set the current time, press and hold the CLOCK button until the display blinks. Use the + and - buttons to adjust the hour and minute. Press CLOCK again to confirm.
Can I use the P40000RT1 for a 120V pool pump?
Yes, but the timer is rated for 240V. For 120V operation, the relay can handle up to 40A. However, wiring must be configured for 120V, and the pump should be within the rated horsepower.
What is the maximum number of on/off events per day?
The timer supports up to four on/off events per day, allowing flexible scheduling for filtration or lighting cycles.
How do I manually override the timer?
Use the MANUAL toggle switch on the front panel to turn the load on or off at any time. The programmed schedule resumes at the next event.
Is the P40000RT1 weatherproof?
The enclosure is weather-resistant but not fully submersible. It should be installed in a sheltered location or under a cover when exposed to rain.
What tools are needed for installation?
Installation requires a flathead screwdriver for wiring terminals and a Phillips screwdriver for mounting screws. Electrical knowledge is strongly advised.
Why is my timer not switching on despite being programmed?
Check that the circuit breaker is on and the MANUAL switch is in AUTO position. Also verify that the current time is correct and the event times are set properly.
Can I replace the timer mechanism myself?
Yes, the internal timer module is customer-replaceable. Disconnect power, remove the old module, and insert a new one. Ensure compatibility with the P40000RT1.
What does the red light on the timer indicate?
A solid red light (LED) usually indicates that power is applied to the timer. A blinking light may signal a programming error or low backup battery.
How do I reset the timer to factory defaults?
Press and hold both + and - buttons simultaneously for 10 seconds until the display resets. This clears all programmed events and time settings.
User questions about P40000RT1 INTERMATIC
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Uncategorized in PDF format for free! Find your manual P40000RT1 - INTERMATIC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. P40000RT1 by INTERMATIC.