ET2105CP - Uncategorized INTERMATIC - Free user manual and instructions
Find the device manual for free ET2105CP INTERMATIC in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Electronic Timer |
| Brand | Intermatic |
| Model | ET2105CP |
| Input Voltage | 120 V AC, 60 Hz |
| Maximum Load | 15 A (general purpose) |
| Timer Type | 24-Hour mechanical timer |
| Number of Poles | 1 Pole |
| Number of ON/OFF Settings | 2 ON / 2 OFF per day |
| Minimum ON/OFF Time | 30 minutes |
| Indoor/Outdoor Use | Indoor only |
| Dimensions (Approximate) | 4.0 x 2.5 x 2.0 inches |
| Weight | 0.25 lbs |
| Operating Temperature Range | 0°C to 40°C (32°F to 104°F) |
| Housing Material | High-impact plastic |
| Mounting | Wall-mount with included screws |
| Certifications | UL Listed |
| Warranty | 1-Year Limited |
Frequently Asked Questions - ET2105CP INTERMATIC
How do I set the time on my Intermatic ET2105CP timer?
Turn the dial clockwise until the correct time lines up with the arrow. Use a small screwdriver to move the trippers for ON and OFF times.
What is the maximum load rating for the ET2105CP?
The ET2105CP is rated for 15 amps at 120 VAC for general purpose loads, or 10 amps for electric motor loads.
Can I use the ET2105CP outdoors?
No, this timer is designed for indoor use only. Install in a dry location away from moisture.
How do I set multiple ON/OFF times?
Each tripper controls one ON or OFF event. Use two trippers for one ON/OFF cycle, and four for two cycles per day.
What happens during a power outage?
The timer has a battery backup (not included) that maintains the timekeeping for up to 24 hours. Without it, the timer will need to be reset after power loss.
How do I replace the battery?
Open the timer case and locate the battery compartment. Replace with a 9V alkaline battery.
My timer is not keeping accurate time. What should I check?
Ensure the time is set correctly and the dial moves freely. If the battery is dead, replace it. The timekeeping motor may be faulty if the issue persists.
Is this timer compatible with LED bulbs?
Yes, but ensure the total LED load does not exceed the timer's rating. Some LEDs may cause a flicker due to low power draw; a minimum load may be required.
Can I wire the ET2105CP for 240V operation?
No, this model is designed for 120V AC only. For 240V applications, use an Intermatic model like the ET2800 series.
What do I do if the timer does not turn on/off at the set time?
Check the trippers are not loose and making contact. Ensure the timer is correctly wired and the manual override switch (if present) is in AUTO.
User questions about ET2105CP INTERMATIC
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.