PX9110 - Sensor IFM - Free user manual and instructions
Find the device manual for free PX9110 IFM in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Pressure Sensor |
| Model | PX9110 |
| Brand | IFM |
| Measuring Range | 0 to 100 bar |
| Output Signal | 4 to 20 mA analog |
| Supply Voltage | 18 to 30 V DC |
| Process Connection | G1/4 male thread |
| Housing Material | Stainless steel 316L |
| Dimensions (L x Ø) | 70 mm x 27 mm |
| Weight | 120 g |
| Protection Class | IP67 |
| Operating Temperature | -25°C to +85°C |
| Medium Temperature | -25°C to +125°C |
| Accuracy | ±0.5% FS |
| Response Time | < 1 ms |
| Current Consumption | < 20 mA |
| Electrical Connection | M12 connector, 4-pin |
| Maintenance | No regular maintenance required; keep dry and clean |
| Safety | Complies with EN 61010; overvoltage protection |
| Spare Parts | Available: O-rings, connectors |
Frequently Asked Questions - PX9110 IFM
What is the output signal of the IFM PX9110?
The output signal is a standard 4 to 20 mA analog current loop.
What is the maximum pressure for the PX9110?
The maximum operating pressure is 100 bar. Overpressure up to 150 bar is tolerated.
Can the PX9110 be used with corrosive media?
Yes, the stainless steel housing and ceramic measuring cell resist many corrosive media. Check compatibility with IFM.
How do I connect the PX9110 to a PLC?
Use an M12 cable with 4 pins: pin 1 = V+, pin 2 = out, pin 3 = GND, pin 4 = not used. Connect to analog input.
What is the accuracy of the PX9110?
Accuracy is ±0.5% of full scale, including non-linearity, hysteresis, and repeatability.
Can the PX9110 be used in outdoor environments?
Yes, the sensor has IP67 protection and operates from -25°C to +85°C.
What maintenance does the PX9110 require?
Minimal maintenance: keep the pressure port clean and check O-rings periodically. No internal calibration needed.
Is the PX9110 compatible with water?
Yes, it is suitable for water and non-aggressive liquids. For aggressive media, verify material compatibility.
How do I zero adjust the PX9110?
The sensor is factory calibrated and typically does not require zero adjustment. If needed, use a trimming potentiometer under the label.
What is the response time of the PX9110?
Response time is less than 1 ms, suitable for dynamic pressure monitoring.
User questions about PX9110 IFM
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Sensor in PDF format for free! Find your manual PX9110 - IFM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PX9110 by IFM.