Phoenix Contact

PSR-SCP-24DC/TS/S - Uncategorized Phoenix Contact - Free user manual and instructions

Find the device manual for free PSR-SCP-24DC/TS/S Phoenix Contact in PDF.

📄 27 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Phoenix Contact PSR-SCP-24DC/TS/S - page 8
View the manual : Français FR Deutsch DE English EN Español ES Italiano IT
Pick your language and provide your email: we'll send you a specifically translated version.
Product type Monostable safety relay
Brand Phoenix Contact
Model PSR-SCP-24DC/TS/S
Rated supply voltage 24 V DC
Supply voltage range 19.2 V DC to 30 V DC
Typical supply current 50 mA
Number of contacts 2 safety contacts (N.O.), 1 auxiliary contact (N.C.)
Maximum contact current 6 A
Maximum contact voltage 250 V AC / 24 V DC
Dimensions (W x H x D) 12.5 mm x 114.5 mm x 106 mm
Weight Approx. 120 g
Connection type Screw terminals
Connectable conductor cross-section 0.2 mm² to 2.5 mm²
Operating temperature -25 °C to +55 °C
Main functions Emergency stop monitoring, light curtain protection, safety contactor control
Maintenance and cleaning Clean with a dry cloth; periodically check connections
Protection rating IP20
Certifications CE, UL, SIL 3 according to IEC 62061

Frequently Asked Questions - PSR-SCP-24DC/TS/S Phoenix Contact

What is the supply voltage of the PSR-SCP-24DC/TS/S ?
The rated supply voltage is 24 V DC, with a range of 19.2 V DC to 30 V DC.
How to wire the safety relay?
Use screw terminals. Connect the power supply (A1/A2), safety contacts (13/14, 23/24) and auxiliary contact (31/32). Follow the diagram in the manual.
What is the function of the auxiliary contact?
The auxiliary contact (NC) indicates the relay status: it is closed when the relay is active and open in case of fault.
Can this relay be used with light curtains?
Yes, it is designed for monitoring light curtains and emergency stops, with redundancy and dynamic testing.
What is the maximum conductor cross-section?
The connectable cross-section is 0.2 mm² to 2.5 mm² with or without ferrules.
How to reset the relay after a fault?
Turn off and then restore the power supply. If the fault persists, check the wiring and the safety inputs.
Does the relay support an inductive load?
Yes, for inductive loads such as contactors, provide a freewheeling diode across the coil.
What safety level is achieved?
This relay is certified SIL 3 according to IEC 62061 and category 4 according to EN 954-1.
Where can I find the detailed wiring diagram?
The diagram is provided in the user manual downloadable on the product page.
How to test the relay without equipment?
Simulate a fault by opening the safety input: the relay should deactivate and the auxiliary contact open. Return the input to the safe state to reactivate.

User questions about PSR-SCP-24DC/TS/S Phoenix Contact

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual PSR-SCP-24DC/TS/S - Phoenix Contact and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PSR-SCP-24DC/TS/S by Phoenix Contact.

USER MANUAL PSR-SCP-24DC/TS/S Phoenix Contact

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Phoenix Contact

Model : PSR-SCP-24DC/TS/S

Category : Uncategorized