| Product Type | UPS (Uninterruptible Power Supply) with line conditioner |
| Brand | Furman |
| Model | F1500-UPS E |
| Capacity | 1500 VA / 1200 W |
| Topology | Line-interactive with AVR (automatic voltage regulation) |
| Input Voltage | 120 VAC |
| Output Voltage | 120 VAC +/– 10 % |
| Frequency | 50/60 Hz (auto-detection) |
| Number of Output Outlets | 8 NEMA 5-15R outlets (4 with surge protection) |
| Battery Type | Sealed lead-acid, 12 V / 9 Ah (2 batteries in series) |
| Typical Runtime | Approximately 10 to 15 minutes at full load |
| Surge Protection | Yes, with varistor and EMI/RFI filter |
| Line Conditioning | Active filtering and voltage regulation (AVR) |
| Connectivity | USB and RS-232 ports for management and automatic shutdown |
| Display | Multifunction LCD (voltage, load, runtime, mode) |
| Form Factor | Rackmount 2U (installable in rack or tower) |
| Dimensions (W × D × H) | 430 × 380 × 89 mm |
| Weight | 12.7 kg (28 lbs) |
| Operating Temperature | 0°C to 40°C |
| Audible Noise | < 45 dB (variable speed fan) |
| Certification | UL, cUL, FCC Class B |
| Warranty | 3 years (batteries: 1 year) |
| Maintenance and Cleaning | Dust the air intake filter with a soft vacuum; avoid liquids |
| Spare Parts and Repairability | User-replaceable batteries; Furman technical support |
| General Information | Designed to protect sensitive audio, video, and computer equipment |
Frequently Asked Questions - F1500-UPS E Furman
How to replace the battery of the Furman F1500-UPS E?
Disconnect the unit from mains, remove the front panel, disconnect battery cables, replace with two identical 12V/9Ah batteries (CSB type or equivalent), then reconnect and close.
What is the typical runtime of the F1500-UPS E?
At full load (1200 W), runtime is approximately 10 to 15 minutes. At half load, it can reach 30 minutes.
Does the Furman F1500-UPS E protect against power surges?
Yes, it includes surge protection (varistor) and an EMI/RFI filter to reduce interference.
Can I use the F1500-UPS E with my professional audio equipment?
Yes, it is specially designed for sensitive audio, video, and computer equipment, thanks to its line conditioning and AVR regulation.
How to recharge the battery after a power outage?
Plug the UPS into a wall outlet; the battery recharges automatically in about 4 to 6 hours depending on discharge level.
Is the Furman F1500-UPS E compatible with management software?
Yes, it is compatible with UPS management software via USB and RS-232 ports (e.g., Furman Power Management or third-party software).
What to do if the UPS emits a continuous beep?
A continuous beep usually indicates a defective battery or overload. Check the total connected power and test the battery.
Can I install the F1500-UPS E in a vertical (tower) position?
Yes, the 2U chassis can be used in rack or tower with the provided feet. Ensure adequate ventilation.
What is the output voltage in battery mode?
In battery mode, the output voltage is a simulated (approximated) sine wave at 120V +/- 10%.
How to clean the UPS air intake filter?
Use a low-power vacuum cleaner or a soft brush to remove dust from the front filter. Avoid moisture and solvents.