Product Type Portable Air Conditioner
Cooling Capacity 7000 BTU/h
Dimensions (W x D x H) 350 x 450 x 700 mm
Weight 25 kg
Power Supply 220-240 V / 50 Hz
Power Consumption (Cooling) 800 W
Refrigerant R290
Noise Level 55 dB(A)
Airflow Rate 300 m³/h
Dehumidification Capacity 1.5 L/h
Fan Speeds 3 (Low, Medium, High)
Timer 24-hour programmable
Remote Control Included
Filter Type Washable mesh filter
Condensate Drainage Continuous drain option
Window Kit Included Yes
Energy Efficiency Ratio (EER) 2.75
Safety Features Overheat protection, auto restart
Maintenance Clean filter every 2 weeks; check drain

Frequently Asked Questions - AC 7000 Dantherm

How do I install the exhaust hose?
Connect the exhaust hose to the back of the unit and route it out through an open window using the included window kit. Ensure the hose is as short as possible for maximum efficiency.
Can I use the AC 7000 in a room without a window?
No, the unit must vent warm air outside. A window, sliding door, or a hole in the wall is required for the exhaust hose.
How often should I clean the air filter?
Clean the washable filter every two weeks under normal use. More frequently in dusty environments. Slide out the filter and rinse with warm water.
Does the AC 7000 have a dehumidifier mode?
Yes, it has a dehumidification function. In this mode, the fan runs continuously while the compressor cycles to remove moisture.
How do I drain the water tank?
The unit self-evaporates most water, but in high humidity you may need to attach a drain hose to the continuous drain outlet. Alternatively, empty the internal tank when full.
What is the energy efficiency rating?
The Energy Efficiency Ratio (EER) is 2.75, which is standard for a portable unit. For optimal efficiency, ensure the exhaust hose is properly sealed.
Can I use an extension cord?
It is not recommended. Plug the unit directly into a grounded wall outlet. If necessary, use a heavy-duty extension cord rated for 15A with a minimal length.
The unit is blowing but not cooling. What should I check?
First, check that the filter is clean and the exhaust hose is not blocked. Ensure the set temperature is below room temperature. If still not cooling, the refrigerant may be low.
How do I set the timer?
Press the Timer button on the remote or control panel. Use the +/- buttons to set the desired off time. The unit will turn off automatically after that period.
Is the AC 7000 safe to leave unattended?
Yes, it has overheat protection and auto restart after a power outage. However, always follow basic safety: keep away from water, and do not cover the unit.

User questions about AC 7000 Dantherm

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air Conditioning in PDF format for free! Find your manual AC 7000 - Dantherm and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AC 7000 by Dantherm.

USER MANUAL AC 7000 Dantherm

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Dantherm

Model : AC 7000

Category : Air Conditioning